郸城县人民医院西南院区新建项目环评报告书.pdf
目录 第一章概述 ......................................................................................................................................................................................1 1.1 项目由来 ......................................................................................................................................................................... 1 1.2 项目特点 ......................................................................................................................................................................... 5 1.3 工作过程 ......................................................................................................................................................................... 6 1.4 分析判定相关情况 ......................................................................................................................................................8 1.5 关注的主要环境问题及环境影响 ......................................................................................................................10 1.6 结论 ................................................................................................................................................................................ 12 第二章总则 ................................................................................................................................................................................... 13 2.1 编制依据 .......................................................................................................................................................................13 2.1.1 法律法规 .........................................................................................................................................................13 2.1.2 技术规范及方法 .......................................................................................................................................... 14 2.1.3 项目文件依据 ............................................................................................................................................... 15 2.2 评价对象 .......................................................................................................................................................................15 2.3 环境影响识别及评价因子筛选 ...........................................................................................................................15 2.3.1 环境影响识别 ............................................................................................................................................... 15 2.3.2 评价因子筛选 ............................................................................................................................................... 16 2.4 评价工作等级 .............................................................................................................................................................17 2.4.1 大气环境评价工作等级及范围 .............................................................................................................17 2.4.2 水环境评价工作等级及范围 ..................................................................................................................18 2.4.3 声环境评价工作等级及范围 ..................................................................................................................19 2.4.4 土壤环境评价工作等级及范围 .............................................................................................................19 2.4.5 生态环境评价等级 ..................................................................................................................................... 19 2.4.6 环境风险评价等级 ..................................................................................................................................... 20 2.5 污染控制与环境保护目标 .................................................................................................................................... 21 2.6 评价标准 .......................................................................................................................................................................23 2.6.1 环境质量标准 ............................................................................................................................................... 23 2.6.2 污染物排放标准 .......................................................................................................................................... 24 2.7 工程和环境特点 ........................................................................................................................................................ 25 2.7.1 工程特点 .........................................................................................................................................................25 2.7.2 环境特点 .........................................................................................................................................................26 2.8 评价总体思路及评价重点 .................................................................................................................................... 26 2.9 专题设置 .......................................................................................................................................................................27 第三章工程分析 ......................................................................................................................................................................... 28 3.1 建设项目概况 .............................................................................................................................................................28 3.1.1 本项目基本情况 .......................................................................................................................................... 28 3.1.2 本项目组成及建设规模 ........................................................................................................................... 28 3.1.3 科室设置 .........................................................................................................................................................32 3.1.4 主要设备及原辅料 ..................................................................................................................................... 32 I 3.1.5 公用项目及能源消耗 ................................................................................................................................ 43 3.2 工艺流程及主要产污环节 .................................................................................................................................... 53 3.2.1 施工期工艺流程及产污分析 ..................................................................................................................53 3.2.2 运营期工艺流程及产污分析 ..................................................................................................................56 3.3 污染物产生及排放情况分析 ................................................................................................................................60 3.3.1 施工期污染源及其防治措施 ..................................................................................................................60 3.3.2 运营期污染源及其防治措施 ..................................................................................................................69 3.4 非正常工况 ..................................................................................................................................................................89 第四章环境现状调查与评价 .................................................................................................................................................91 4.1 自然环境概况 .............................................................................................................................................................91 4.1.1 地理位置 .........................................................................................................................................................91 4.1.2 地形地貌 .........................................................................................................................................................91 4.1.3 水文 ...................................................................................................................................................................91 4.1.4 气象特征 .........................................................................................................................................................94 4.1.5 土壤、动植物 ............................................................................................................................................... 95 4.1.6 生态环境 .........................................................................................................................................................96 4.2 环境质量现状监测与评价 .................................................................................................................................... 96 4.2.1 环境空气质量现状监测与评价 .............................................................................................................96 4.2.2 水环境质量现状调查与评价 ..................................................................................................................98 4.2.3 声环境现状评价 ....................................................................................................................................... 105 4.2.4 小结 ................................................................................................................................................................106 第五章环境影响预测与评价 .............................................................................................................................................. 108 5.1 施工期环境影响分析 ............................................................................................................................................108 5.1.1 废气 ................................................................................................................................................................108 5.1.2 施工废水 ...................................................................................................................................................... 110 5.1.3 噪声 ................................................................................................................................................................111 5.1.4 固体废物 ...................................................................................................................................................... 112 5.1.5 生态环境影响分析 ...................................................................................................................................112 5.1.6 施工期环境管理 ....................................................................................................................................... 112 5.2 营运期环境影响分析 ............................................................................................................................................112 5.2.1 地表水环境影响分析 ..............................................................................................................................112 5.2.2 地下水环境影响分析 ..............................................................................................................................117 5.2.3 环境空气影响分析 ...................................................................................................................................118 5.2.4 声环境影响分析 ....................................................................................................................................... 126 5.2.5 固体废物环境影响分析 .........................................................................................................................133 5.2.6 土壤环境影响分析 ...................................................................................................................................137 5.3 生态环境影响评价 ................................................................................................................................................ 138 5.3.1 概述 ................................................................................................................................................................138 5.3.2 生态环境现状调查与评价 ....................................................................................................................139 5.3.3 生态环境影响分析 ...................................................................................................................................140 5.3.4 景观影响 ...................................................................................................................................................... 148 II 5.4 环境风险分析与评价 ............................................................................................................................................148 5.4.1 评价依据 ...................................................................................................................................................... 149 5.4.2 环境风险识别及分析 ..............................................................................................................................161 5.4.3 环境风险分析及防范措施 ....................................................................................................................162 5.4.4 风险事故应急预案 ...................................................................................................................................169 5.4.5 风险评价结论 ............................................................................................................................................ 170 第六章环境保护措施及其可行性论证 ...........................................................................................................................172 6.1.施工期污染防治措施 ........................................................................................................................................... 172 6.1.1.废气污染防治措施 .................................................................................................................................. 172 6.1.2.废水防治措施 ............................................................................................................................................ 174 6.1.3.噪声污染防治措施 .................................................................................................................................. 174 6.1.4.固体废物污染防治措施 .........................................................................................................................176 6.1.5.文明施工 ......................................................................................................................................................177 6.2.运营期污染防治措施 ........................................................................................................................................... 179 6.2.1 废水治理措施评价 ...................................................................................................................................179 6.2.2 废气治理措施评价 ...................................................................................................................................190 6.2.3 固体废物处理措施评价 .........................................................................................................................195 6.2.4 环境噪声污染防治措施分析 ............................................................................................................... 205 6.2.5 地下水、土壤污染防范措施 ............................................................................................................... 206 6.3 环保措施汇总 .......................................................................................................................................................... 210 6.4 环保设施验收清单 ................................................................................................................................................ 213 第七章环境经济损益分析 ................................................................................................................................................... 217 7.1 环境经济损益的目的 ........................................................................................................................................217 7.2 经济效益分析 .......................................................................................................................................................... 217 7.3 社会效益分析 .......................................................................................................................................................... 217 7.4 环境效益分析 .......................................................................................................................................................... 218 7.5 环境经济损益分析 ................................................................................................................................................ 220 7.5.1 环保工程投资概算 ...................................................................................................................................220 7.5.2 运营期环保支出 ....................................................................................................................................... 221 7.6 结论 ..............................................................................................................................................................................222 第八章产业政策相符性及厂址可行性分析 .................................................................................................................223 8.1 与产业政策和相关规划符性分析 ................................................................................................................... 223 8.1.1 与产业政策相符性分析 .........................................................................................................................223 8.1.2 与行业政策符合性分析 .........................................................................................................................223 8.1.3 与相关规划符合性分析 .........................................................................................................................229 8.2 厂址可行性分析 ..................................................................................................................................................... 242 8.2.1 用地规划符合性分析 ..............................................................................................................................242 8.2.3 满足传染病医院设计规范要求 .......................................................................................................... 242 8.2.2 外环境对本项目的影响 .........................................................................................................................243 8.2.3 环境功能区符合性分析 .........................................................................................................................243 8.2.4 选址可行性分析结论 ..............................................................................................................................244 III 8.3 医院平面布置合理性分析 ..................................................................................................................................244 8.3.1 平面布置原则 ............................................................................................................................................ 244 8.3.2 项目平面布置方案 ...................................................................................................................................244 8.3.3 项目公用工程布置合理性分析 .......................................................................................................... 245 8.4 总量控制分析 .......................................................................................................................................................... 246 8.4.1 总量控制目的 ............................................................................................................................................ 246 8.4.2 总量控制因子 ............................................................................................................................................ 246 8.4.3 本项目总量控制指标 ..............................................................................................................................246 第九章环境管理与监测计划 .............................................................................................................................................. 248 9.1 环境管理 ....................................................................................................................................................................248 9.1.1 环境管理的必要性 ...................................................................................................................................248 9.1.2 环境管理机构的设置 ..............................................................................................................................248 9.1.3 环境管理机构的职责 ..............................................................................................................................248 9.1.4 环境管理建议 ............................................................................................................................................ 249 9.2 环境监测 ....................................................................................................................................................................251 9.2.1 环境监测的目的 ....................................................................................................................................... 251 9.2.2 环境监测机构的设置 ..............................................................................................................................252 9.2.3 环境监测机构的职责 ..............................................................................................................................252 9.2.4 环境监测计划 ............................................................................................................................................ 252 9.3 排污口标志和管理 ................................................................................................................................................ 253 9.3.1 排污口标志 ................................................................................................................................................. 253 9.3.2 排污管理 ...................................................................................................................................................... 254 9.4 污染物排放清单 ..................................................................................................................................................... 255 9.5 “三同时”竣工验收内容 ........................................................................................................................................258 第十章 环境影响评价结论 ........................................................................................................................................261 10.1 评价结论 ..................................................................................................................................................................261 10.1.1 项目建设符合国家相关产业政策的要求 .................................................................................... 261 10.1.2 区域环境质量 ..........................................................................................................................................261 10.1.3污染物达标排放及环保措施可行 ....................................................................................................262 10.1.4 环境风险分析 ..........................................................................................................................................265 10.1.5项目建设厂址从环保角度来讲是可行的 ..................................................................................... 265 10.1.6 公众参与 ....................................................................................................................................................265 10.1.7 总量控制 ....................................................................................................................................................265 10.2 对策和建议 .............................................................................................................................................................266 IV 附图 附图 1 项目地理位置图 附图 2 医院周边环境示意图 附图 3 医院平面布置图 附图 4 门诊医技综合楼 1 层平面图 附图 5-1 门诊医技综合楼 2 层平面图 附图 5-2 门诊医技综合楼 3 层平面图 附图 5-3 门诊医技综合楼 4 层平面图 附图 5-4 门诊医技综合楼 5-10 层平面图 附图 6-1 呼吸道病房楼 1 层 附图 6-2 呼吸道病房楼 2 层 附图 6-3 呼吸道病房楼 3-5 层 附图 7-1 发热门诊楼一层布置图 附图 7-2 发热门诊楼二层布置图 附图 8 病房宿舍连体楼平面布置图 附图 9 大气、声环境质量监测点位分布图 附图 10 地下水环境质量监测点位分布图 附图 11 郸城县城区声环境功能区划图 附图 12 郸城县城市总体规划(2017-2030)土地使用规划图 附图 13 项目地块控制性详细规划 附图 14 项目在河南省三线一单成果查询系统中的位置 附图 15 本项目与郸城县城集中式饮用水源位置关系图 附图 16 本项目与周边乡镇集中式饮用水源位置关系图 附图 17 项目医院与郸城县第三污水处理厂的位置关系及排水路径 V 附图 18 项目区域土地利用现状图 附图 19 项目区域植被类型图 附图 20 项目现状及周边环境照片 附件 附件 1 委托书 附件 2 可研批复 附件 3 项目用地地的会议纪要 附件 4 项目选址意见书 附件 5 环评执行标准函 附件 6 事业单位法人证书 附件 7 医疗机构执行许可证 附件 8 法人代表身份证复印件 附件 9 检测报告 附件 10 建设单位环保承诺书 附表 附表 1 建设项目大气环境影响评价自查表 附表 2 地表水环境影响评价自查表 附表 3 风险环境影响评价自查表 附表 4 声环境影响评价自查表 附表 5 生态环境影响评价自查表 附录 建设项目环境影响报告书审批基础信息表 VI 郸城县人民医院西南院区新建项目环境影响报告书 第一章概述 第一章概述 1.1项目由来 郸城县人民医院始建于 1952 年,位于郸城县人民路北段 42 号,老院区占 地面积 41186 平方米,总建筑面积 57406 平方米,编制床位数 1100 张,床位使 用率 95.68%。现有职工人数 2045 人,其中:中级职称人数 440 人、副高级及 以上人数 100 人、其他医疗技术人员 1505 人。郸城县人民医院是郸城县域内规 模最大的集医疗、教学、科研、保健为一体的公益性综合医院。2020 年 10 月, 被表彰为河南省抗击新冠肺炎疫情先进集体。 近些年来,全球变暖、环境污染、欠发达国家公共卫生服务能力薄弱、原 生物病耐药性变异等情况,催生埃博拉、疯牛病、禽流感、炭疽热、SARS、脊 髓灰质炎、“寨卡”、H1N1、新冠病毒肺炎等疫情蔓延。频发的重大突发公共事 件警醒国家必须补齐重大突发公共卫生事件应急救援的短板。 面对此类重大突发公共灾难,我国充分展现了中国力量、中国速度,更体 现了中国特色社会主义制度的优越性。但是,我们也深刻认识到,我国在重大 突发公共事件医疗救治方面仍面临较大短板。在统筹推进新冠肺炎疫情防控和 经济社会发展工作部署会议上,总书记强调,要总结经验、吸取教训,深入研 究如何强化公共卫生法治保障、改革完善疾病预防控制体系、改革完善重大疫 情防控救治体系、健全重大疾病医疗保险和救助制度、健全统一的应急物资保 障体系等重大问题,抓紧补短板、堵漏洞、强弱项,提高应对突发重大公共卫 生事件的能力和水平。 在新冠肺炎疫情初期,随着新冠肺炎患者确诊数量的增加,郸城县人民医 院的床位数远不够用,出现“人等床”的情况,且无专业的传染病区业务用房, 极大削弱了郸城县应对重大突发公共卫生事件的医疗救治能力的需求。 根据《周口市人民政府关于印发<周口市“十四五”公共卫生体系和全民健康 规划的通知>》周政〔2022〕24 号,坚持底线思维、平战结合、防治协同和关 口前移、抓早抓小、防微杜渐的原则,建立健全职能明确、分工合作、运转顺 1 郸城县人民医院西南院区新建项目环境影响报告书 第一章概述 畅、衔接有序的公共卫生应急管理体系,全面提升重大疫情和突发公共卫生事 件的应对能力。完善市、县两级传染病救治网络,建立健全分级、分层、分流 的传染病等重大疫情救治机制。全面加强二级以上综合医院、中医院和所有儿 童专科医院感染性疾病科和发热门诊建设,持续改善县级医院传染病区、重症 医学科等基础设施条件,提高传染病快速检测和诊治水平。重复利用传染病医 院或相对独立的综合性医院传染病区,扩大传染病集中收治容量。 因此郸城县针对这次防控疫情暴露的短板及周政〔2022〕24 号文件精神, 拟在郸城县科技大道北、公园西路西侧地块实施“郸城县人民医院西南院区新 建项目”。西南院区设立感染性疾病科和发热门诊,同时采用平时和战时结合 方式及时建立健全突发公共卫生事件医疗救治体系,前瞻而系统地解决战“疫” 的“后勤补给”问题,提高郸城县在应对突发公共卫生事件上的应急救治能力, 为保护广大人民群众生命财产安全提供有力保障。结合郸城县人民医院的现状 和新冠肺炎防控的方式,能够为疫情防控提供有效的后勤保障,项目的建设是 亟需且必须的。 西南院区的设施均不依托老院区,西南院区建成后两个院区分别独立运行。 西南院区建成后作为传染病医院运行。项目地块南部病房楼、宿舍楼平时作为 传染病房,疫情时作为隔离病房使用。 项目名称为郸城县人民医院西南院区新建项目,项目代码为 2205-41162504-01-725318。2022 年 9 月 15 日郸城县发展和改革委员会对项目可研进行批复, 批复名称《郸城县发展和改革委员会关于郸城县人民医院西南院区新建项目可 行性研究报告的批复》,批复文号:郸发改社会[2022]202 号(附件 2)。根 据 2022 年 6 月 5 日郸城县县政府常务会议纪要[2022]40 号(附件 3),会议 同意划拨郸城县科技大道北、公园西路西侧地块用于实施郸城县人民医院西南 院区新建项目。郸城县自然资源局已出具本项目的选址意见书,见附件 4。 咨询当地卫生部门管理政策,卫生部门不出具项目床位的批复,以发改委 批复床位为准。根据项目可研及批复,本项目总投资 63480 万元,项目共设置 2 郸城县人民医院西南院区新建项目环境影响报告书 第一章概述 床位 800 张, 总 占地 65550m2 , 总 建筑 面积 107656m2 , 其 中 地上 建筑 面积 75501m2 ,地下建筑面积 32155m2 ,其中建筑物包括:4 栋 4F 病房楼(建筑面 积 26107m2,疫情时作为隔离病房使用)、1 栋 5F 宿舍楼(建筑面积 4811m2, 疫情时作为医护人员宿舍)、1 栋 4-10F 门诊医技传染病综合楼(建筑面积 24810m2),1 栋 5F 呼吸道病房楼(建筑面积 7447m2),1 栋 4F 后勤办公综合 楼(建筑面积 8840m2)、1 栋 2F 发热门诊(建筑面积 2178m2)。设置机动车车 位 1140 个。同时配套道路、绿化、变配电、给排水、污水处理系统等附属设施。 本项目主要经济技术指标见表 1-1。 表 1-1 本项目主要经济技术指标表 序号 项目名称 数量 1 建设用地面积(m2) 65550 2 总建筑面积(m2) 107656 地上总建筑面积(m2) 75501 4栋4F病房楼 26107 5F宿舍楼 4811 4-10F门诊医技传染病综合楼 24810 5F呼吸道病房楼 7447 4F后勤办公综合楼 8840 2F发热门诊 2178 变配电所 710 氧气站 78 配套用房 520 2.2 地下总建筑面积(m2) 32155 3 建筑密度(%) 15.98 4 绿地率(%) 35 5 容积率 1.152 6 机动车位(辆) 1140 7 总投资(万元) 63480 8 床位规模(张) 800 2.1 其中 项目计划建设内容与发改委批复基本一致,具体分析如下表。 3 郸城县人民医院西南院区新建项目环境影响报告书 第一章概述 表 1-2 发改委批复相符性分析一览表 项目 发改委批复内容 实际建设内容 郸城县人民医院西南院 郸城县人民医院西南院区新 区新建项目 建项目 郸城县人民医院 郸城县人民医院 郸城县科技大道北、公 郸城县科技大道北、公园西 园西路西侧地块 路西侧地块 设置床位 800张 800张 相符 投资 63480万元 63480万元 相符 总用地 项目总用地面积65550m 总占地65550m2 相符 项目名称 建设单位 建设地点 相符性 相符 相符 相符 项目规划床位800张,拟 使用土地面积65550m2, 项目规划床位800张,拟使用 总建筑面积107757m2, 土地面积65550m2,总建筑面 其中:地上建筑面积 积107656m2,其中:地上建 75902m2,主要建设内容 筑面积75501m2,主要建设内 包括门诊医技综合楼建 容包括门诊医技综合楼建筑 筑面积27662m2、病房楼 面积24810m2、病房楼建筑面 建筑面积34020m2、生活 积33554m2、生活管理用房 2 主要建设 管理用房建筑面积 建筑面积8840m 、附属用房 内容 13390m2、附属用房建筑 建筑面积1308m2;地下建筑 面积830m2;地下建筑面 面积32155m2,主要建设内容 积31855m2,主要建设内 包括地下车库建筑面积 容包括地下车库建筑面 27300m2、地下人防建筑面积 积27300m2、地下人防建 4555m2。配套建设污水处理 筑面积4555m2。配套建 设施、道路、绿化、给排 设污水处理设施、道 水、电力及消防等附属设 路、绿化、给排水、电 施。 床位及总占地均不 变,总建筑面积减 少 101m2 , 各 个 构 筑物建筑物建筑面 积有局部调整,基 本相符 力及消防等附属设施。 项目医院按传染病医院进行建设运营。本项目属于《国民经济行业分类》 (2019 年修订版)中“Q8415 专科医院”。经查阅产业政策,本项目属于《产业 结构调整指导目录(2019 年本)》鼓励类中第三十七条“卫生、健康”中第 6 条“传染病、儿童、精神卫生专科医院和康复,因此,本项目建设符合国家产 业政策。 4 郸城县人民医院西南院区新建项目环境影响报告书 第一章概述 根据《中华人民共和国环境影响评价法》和《建设项目环境保护管理条例》 的有关规定,本项目应进行环境影响评价。依据《建设项目环境影响评价分类 管理名录》(2021 年版)规定:“四十九、卫生 84”中的“108 医院 841”,新建、 扩建住院床位 500 张及以上的”需编制报告书,本项目设置床位 800 张,属新建 项目,应当编制环境影响报告书。 受建设单位委托(见附件 1),我公司承担了本项目的环境影响评价工作。 接受委托后,我公司组织有关技术人员,在现场踏勘、收集资料、走访调查的 基础上,本着“科学、公正、客观、规范”的态度,编制完成了本项目的环境影 响报告书。 本次评价内容为郸城县人民医院西南院区新建项目污染物产生排放情况及 对周围环境的影响,不包括辐射有关内容,辐射内容需另行评价。 1.2项目特点 1、本次工程建设性质属于新建性质。项目占地不涉及拆迁,现状未开工 建设。 2、项目地块位于郸城县科技大道北、公园西路西侧地块。根据 2022 年 6 月 5 日郸城县县政府常务会议纪要[2022]40 号,会议同意划拨郸城县科技大 道北、公园西路西侧地块用于实施郸城县人民医院西南院区新建项目。郸城县 自然资源局已于 2022 年 6 月 16 日核发本项目的建设项目用地预审与选址意见 书,编号为用字第 411625202200024。根据附图 13 项目地块控制性详细规划, 项目用地已调整为医疗卫生用地。项目建设符合郸城县用地规划和城市总体规 划。 3、本项目医院按照传染病医院的要求进行建设。项目设有 1 栋发热门诊、 1 栋呼吸道病房楼,发热门诊楼和呼吸道病房楼内设置空气传播传染病房,其 他病床设为非空气传播传染病房。医院南部病房楼平时作为非空气传播传染病 房使用,疫情时作为隔离病房使用。 5 郸城县人民医院西南院区新建项目环境影响报告书 第一章概述 4、项目全院设置一个污水处理站位于地块西南角,主导风向的下风向主要 为配套用房、氧气站和变配电所等,下风向未设置门诊楼和病房楼,影响不大。 5、项目病房楼制冷供暖采用分体空调;宿舍楼采用一拖多多联机,室外采 用风冷换热形式;门诊楼、呼吸道楼、发热门诊、后勤办公综合楼各设 1 套中 央空调风冷热泵机组设于楼顶,采用风冷省去了水冷冷水机组的冷却水系统。 热水采用电热水器,消毒蒸汽采用电蒸汽发生器制备。项目不设置锅炉。 6、本项目排水实行雨污分流、污污分流。雨水直接排入市政雨水管网,病 区食堂废水经油水分离器处理、病区化验室废水经酸碱中和处理后经过臭氧预 消毒,然后与化粪池+臭氧预消毒处理过的病区其他医疗废水(门诊废水、 住 院病房废水、 医务人员废水、空调冷凝水、蒸汽消毒废水)、隔油预处理过的 非病区普通食堂废水、普通化粪池处理过的非病区其他生活污水(后勤办公人 员废水、宿舍楼、空调冷凝水)一起排入医院综合污水处理站进一步处理达标 后,汇入郸城县第三污水处理厂,尾水排入洺河。消毒蒸汽纯水制备浓水和非 病区空调冷凝水作为清排水直接排入医院总排口。 7、本次评价不包含辐射、放射性相关内容的评价,后期单独履行环评手续。 1.3工作过程 评价程序主要分为三部分: (1)前期准备工作,现场工作; 根据《中华人民共和国环境影响评价法》、国务院第 682 号令《建设项目 环境保护管理条例》以及中华人民共和国生态环境部制定的《建设项目环境影 响评价分类管理名录(2021 年版)》的有关规定,本建设项目应编制环境影响 报告书。 郸城县人民医院委托我公司承担该项目环境影响报告书编制工作。我方接 受委托后,我公司组织专业技术人员到现场针对项目特点、性质、规模、所在 地环境现状和区域发展规划进行调查、踏勘和资料收集。 (2)现场监测与资料收集、资料分析 6 郸城县人民医院西南院区新建项目环境影响报告书 第一章概述 我公司委托河南申越检测技术有限公司对项目所在地的环境质量现状进行 监测。 (3)环评报告书编制与审批。 我公司通过项目特征及其排污分析,结合环境影响识别,严格按照《环境 影响评价技术导则》以及相关法律法规要求,编制完成了《郸城县人民医院西 南院区新建项目环境影响报告书》。通过环境影响评价,对项目建设可能产生 的环境影响范围及影响程度进行全面分析、预测和评价,分析项目采取环保措 施的可行性、可靠性并提出进一步环保措施,为建设项目环境管理提供科学依 据。 本次环境影响评价的工作程序详见图 1-1。 7 郸城县人民医院西南院区新建项目环境影响报告书 图 1-1 第一章概述 建设项目环境影响评价工作程序图 1.4分析判定相关情况 1、产业政策判定 根据国家发改委《产业结构调整指导目录(2019 年本)》,本项目属于鼓 励类中第三十七条“卫生、健康”中第 6 条“传染病、儿童、精神卫生专科医 院和康复,因此,本项目建设符合国家产业政策。 2、土地规划及郸城县总体规划相符性 项目地块位于郸城县科技大道北、公园西路西侧地块。根据 2022 年 6 月 5 日郸城县县政府常务会议纪要[2022]40 号,会议同意划拨郸城县科技大道北、 8 郸城县人民医院西南院区新建项目环境影响报告书 第一章概述 公园西路西侧地块用于实施郸城县人民医院西南院区新建项目。郸城县自然资 源局已于 2022 年 6 月 16 日核发本项目的建设项目用地预审与选址意见书,编 号为用字第 411625202200024。根据附图 13 项目地块控制性详细规划,项目用 地已调整为医疗卫生用地。项目建设符合郸城县用地规划和城市总体规划。 3、三线一单符合性分析 根据《河南省人民政府关于实施“三线一单”生态环境分区管控的意见》 (豫政[2020]37 号)、《河南省生态环境厅关于发布河南省生态环境分区管控 总体要求(试行)的函》(豫环函[2021]171 号)和《关于发布<周口市“三线一 单”生态环境准入清单(试行)>的函》(周环函【2022】03 号),项目所在地环 境管控单元编号为 ZH41162530001,为郸城县一般管控单元。 经分析,本次工程与“三线一单”的相关控制要求相符 4、评价等级分析判定 (1)环境空气环境影响评价等级 依据《环境影响评价技术导则─大气环境》(HJ2.2-2018),按照估算模式 计算,确定本次工程环境空气影响评价工作等级为三级。 (2)地表水环境影响评价等级 本项目废水包括食堂废水、病区化验废水,门诊楼及病房楼产生的医疗废 水及空调冷凝水,后勤办公综合楼、宿舍产生的普通生活污水。全院设置 1 个 污水处理站处理后排入公园西路市政污水管网汇入郸城县第三污水处理厂进行 处理。根据 HJ2.3-2018《环境影响评价技术导则—地表水环境》,本次工程地 表水评价等级为三级 B。 (3)地下水环境影响评价等级 本次工程为郸城县人民医院西南院区新建项目,根据项目可研项目为三级 医院。根据《环境影响评价技术导则地下水环境》(HJ610-2016),本次工程 地下水环境影响评价项目类别为Ⅳ类,Ⅳ类项目不开展地下水环境影响评价。 (4)声环境影响评价等级 9 郸城县人民医院西南院区新建项目环境影响报告书 第一章概述 根据《环境影响评价技术导则(声环境)》(HJ2.4-2021)中有关声环境 影响评价工作等级划分原则,确定本次工程声环境影响评价为二级评价。 (5)土壤环境影响评价等级 本次工程属于医院类建设项目,根据《环境影响评价技术导则土壤环境 (试行)》(HJ964-2018)表 A.1 土壤环境影响评价项目类别,本次工程属于 “社会事业与服务业”中“其他”的Ⅳ类项目,Ⅳ类项目不开展土壤环境影响评价 工作。 (6)环境风险评价等级 根据项目情况,本次工程环境风险评价为简单分析。 1.5关注的主要环境问题及环境影响 本项目位于郸城县科技大道北、公园西路西侧地块,根据项目的建设内容, 通过分析,项目投入使用后对周围环境可能产生的影响主要有: (1)废水:运营期废水包括病区医疗废水(化验室废水、门诊废水、 住 院病房废水、 医务人员废水、空调冷凝水、蒸汽消毒废水、病区食堂废水)、 非病区废水(后勤办公人员废水、宿舍楼、普通食堂、空调冷凝水)。医院不 使用氰化物、 含铬等试剂, 不产生含氰、 含铬废水, 且影像科采用数码打印 不产生洗印废水,口腔科采用环氧树脂代替汞合金,不使用银汞合金,不产生 无汞废水。院区洗衣外协不设洗衣房,不产生洗衣废水。项目建成后总排水量 为 609.24m3/d,病区食堂废水经油水分离器处理、病区化验室废水经酸碱中和 处理后经过臭氧预消毒,然后与化粪池+臭氧预消毒处理过的病区其他医疗废水 (门诊废水、 住院病房废水、 医务人员废水、空调冷凝水、蒸汽消毒废水)、 隔油预处理过的非病区普通食堂废水、普通化粪池处理过的非病区其他生活污 水(后勤办公人员废水、宿舍楼、空调冷凝水)一起排入医院综合污水处理站 进一步处理达标后,汇入郸城县第三污水处理厂,尾水排入洺河。消毒蒸汽纯 水制备浓水和非病区空调冷凝水作为清排水直接排入医院总排口。 10 郸城县人民医院西南院区新建项目环境影响报告书 第一章概述 (2)废气:本项目运营期产生的废气主要为含菌废气、检验废气、泊车位 汽车废气、食堂油烟、污水处理站产生的恶臭、垃圾收集站恶臭、备用柴油发 电机燃烧废气。病区含菌废气采用紫外线杀菌后经专用烟道排放,手术室、负 压病房采用全新风直流式空调系统,送风应经过初效、中效、高效过滤器三级 处理,排风经过高效过滤器过滤处理后经过专用排风烟道引至楼顶排放;检验 废气经安全柜自带的高效空气过滤器处理后去除致病细菌、生物气溶胶及其他 污染物有害气体后,再引至楼顶排放,排气中的致病细菌及生物气溶胶可被除 去,减轻对环境和周围环境的影响,同时医院做好检验室内的消毒卫生工作, 确保检验废气处理后不会对周围环境造成明显影响;地下车位周围空旷,汽车 尾气易于扩散。地下车库安装抽排风系统,加强地下车库空气流通;地下污水 处理站恶臭经负压收集+生物除臭+紫外线消毒装置处理后经管道引至附近病房 楼楼顶排放(20m 高,周边最近病房楼设计高度 18.65m);垃圾收集站恶臭采 用垃圾袋装化、及时清运,日产日清,投加除臭剂等措施;柴油发电机燃烧废 气经自带净化装置处理后引至楼顶排放。 (3)固废:医务后勤人员办公及宿舍产生的普通生活垃圾分类收集后,日 产日清,每天由环卫部门负责清运至市政垃圾中转站,最终运至郸城县生活垃 圾焚烧厂发电厂焚烧。废反渗透膜(纯水制备)更换后随生活垃圾一同交环卫 部门清运处理。餐厨垃圾采用专用餐厨垃圾收集桶收集,集中收集后交由有资 质的单位进行运输处 置;门诊、病房楼病人产生的生活垃圾及医疗废物按照医 疗废物进行暂存管理和处置,定期交由有资质单位进行清运处置。污水站栅渣、 污泥消毒脱水后,作为危险废物定期交有资质单位处置。废紫外线含汞灯管危 废间暂存后交由有资质危废单位安全处置。 (4)噪声:本项目运营期噪声主要为中央空调风冷热泵机组,污水站水泵、 污水站风机、食堂风机、液氧站空压机等运转产生的噪声,采取隔声、减振、 消声等降噪措施。 11 郸城县人民医院西南院区新建项目环境影响报告书 第一章概述 通过对项目上述污染物进行定性或定量分析,确定本项目对当地环境可能 造成的不良影响的范围和程度,从而提出避免污染、减少污染的对策措施。 1.6结论 本项目符合国家产业政策,与当地规划相符,选址可行;项目所在区域环 境质量现状总体较好,拟采取的各项污染防治措施有效可行,对周围环境的影 响较小;项目在采取相应的风险措施、实施应急预案后,风险可控;公众参与 调查结果表明,参与者普遍对项目的建设表示支持。因此,在该项目建设及运 营过程中有效落实各项环境保护措施、风险防范措施及其它措施的基础上,从 环境保护角度分析,该项目的建设是可行的。 12 郸城县人民医院西南院区新建项目环境影响报告书 第二章总则 第二章总则 2.1编制依据 2.1.1 法律法规 (1)《中华人民共和国环境保护法》(2015 年 1 月 1 日) (2)《中华人民共和国大气污染防治法》(2018 年 10 月 26 日修订) (3)《中华人民共和国水污染防治法》(2017 年 6 月 27 日修正) (4)《中华人民共和国噪声污染防治法》(2022 年 6 月 5 日施行) (5)《中华人民共和国固体废物污染环境防治法》(2020 年 4 月 29 日修订) (6)《中华人民共和国环境影响评价法》(2018 年 12 月 29 日第二次修正) (7)《中华人民共和国土壤污染防治法》(2019 年 1 月 1 日起施行) (8)《建设项目环境保护管理条例》(国务院令第 682 号)(2017 年 10 月 1 日起实施) (9)《国务院关于环境保护若干问题的决定》(国发[1996]31 号) (10)《国家危险废物名录》(2021 年版) (11)《关于切实加强风险防范严格环境影响评价管理的通知》(环发 〔2012〕98 号) (12)《建设项目环境影响评价分类管理名录》(2021 年版) (13)《环境影响评价公众参与办法》(生态环境部令第 4 号),2019 年 1月1日 (14)《产业结构调整指导目录(2019 年本)》 (15)《医疗废物管理条例》(国务院令第 380 号,2003.06) (16)《医疗废物分类目录》(2021 年版) (17)《危险化学品目录》(2015 年版,2022 年 10 月 13 日调整),自 2023 年 1 月 1 日施行) (18)《医疗卫生机构医疗废物管理办法》(卫生部令第 36 号) 13 郸城县人民医院西南院区新建项目环境影响报告书 第二章总则 (19)河南省环境保护局《关于建设项目主要污染物排放总量核定工作的 通知》豫环文[2009]181 号 (20)《河南省水污染防治条例》(河南省人民政府,2019 年 10 月 1 日实 施) (21)《河南省环境保护厅关于贯彻落实建设项目主要污染物排放总量指 标审核及管理暂行办法的通知》豫环文[2015]18 号 (22)《河南省建设项目环境保护条例》(2016 年修正) (23)《河南省人民政府办公厅关于印发河南省乡镇集中式饮用水源保护 区划的通知》(豫政办[2016]23 号) (24)《河南省人民政府办公厅关于划定调整取消部分集中式饮用水源保 护区的通知》(豫政文[2020]99 号) (25)《河南省建设项目环境影响评价文件分级审批目录》(2019 年本) (26)《周口市生态环境保护委员会办公室关于印发<周口市深入打好秋冬 重污染天气消除、夏季臭氧污染防治和柴油货车污染治理攻坚战行动方案>的通 知》(周环委办[2023]10 号) (27)《周口市生态环境保护委员会办公室关于印发<周口市 2023 年蓝天 保卫战实施方案>的通知》(周环委办[2023]13 号) (28)《周口市生态环境保护委员会办公室关于印发<周口市 2023 年碧水 保卫战实施方案>的通知》(周环委办[2023]11 号) (29)《周口生态环境保护委员会办公室关于印发<周口市 2023 年净土保 卫战实施方案>的通知》(周环委办[2023]12 号) (30)《郸城县污染防治攻坚战领导小组办公室关于印发郸城县 2022 年大 气、水、土壤污染防治攻坚战及农业农村污染治理攻坚战实施方案的通知》 (郸环攻坚办〔2022〕7 号)。 2.1.2 技术规范及方法 (1)《环境影响评价技术导则 总纲》(HJ2.1-2016) 14 郸城县人民医院西南院区新建项目环境影响报告书 第二章总则 (2)《环境影响评价技术导则 大气环境》(HJ2.2-2018) (3)《环境影响评价技术导则 地下水环境》(HJ610-2016) (4)《环境影响评价技术导则 地表水环境》(HJ2.3-2018) (5)《环境影响评价技术导则 声环境》(HJ2.4-2021) (6)《环境影响评价技术导则 生态影响》(HJ19-2022) (7)《环境影响评价技术导则 土壤环境(试行)》(HJ964-2018) (8)《建设项目环境风险评价技术导则》(HJ169-2018) (9)《医疗废物专用包装袋、容器和警示标志标准》(HJ421-2008) (10)《危险废物识别标志设置技术规范》(HJ 1276—2022) (11)《环境保护图形标志—固体废物贮存(处置)场》(GB 15562.21995)修改单(2023 年 7 月 1 日起实施) (10)《传染病医院建筑设计规范》 (GB50849-2014)。 2.1.3 项目文件依据 1、委托书; 2、郸城县人民医院西南院区新建项目可行性研究报告; 3、郸城县人民医院西南院区新建项目可行性研究报告批复; 4、建设单位提供的项目相关资料。 2.2评价对象 本次环境影响评价对象为郸城县人民医院西南院区新建项目。其中,医院 内涉及的医用放射性同位素和射线装置部分等辐射评价不在本次评价范围内, 需按照国家有关辐射项目环境影响工作的相关规定和要求, 委托有辐射评价资 质的单位另行评价。 2.3环境影响识别及评价因子筛选 2.3.1 环境影响识别 评价针对工程工艺特点和区域环境特征,对环境影响因子进行识别,以确 定工程运行期对自然环境、社会环境和生态环境等方面的影响情况。 15 郸城县人民医院西南院区新建项目环境影响报告书 第二章总则 本工程环境影响因素识别内容见表 2-1。 表 2-1 环境影响因素识别表 影响因素 施工期 运行期 类别 土建 安装 运输 噪声 工程 工程 排水 排气 固废 噪声 运输 效益 及振动 -1LP 自 地表水 然 地下水 生 大气环 态 境 环 声环境 -1SP 境 地表 -1SP 土壤 -1SP 植被 -1SP 社 工业 -1SP +2LW 会 农业 -1SP +1LW 经 交通 -1SP 济 公众健 环 康 境 生活质 -1SP -1SP -1SP -1LP -1LP -1SP -1LP -1LP -1LP -1SP -1SP -1LP -1LP +2LW -1LP -1LP +1LW 量 +2LW 就业 备注:影响程度:1-轻微;2-一般;3-显著;影响时段:S-短期;L-长期;影响范围:P-局部;W-大 范围;影响性质:+有利;-不利 2.3.2 评价因子筛选 根据环境影响因素识别、项目污染物排放特点及周围环境质量状况,本次 环评工作各专题的评价因子选取见表 2-2。 表 2-2 项目 专题 评价因子识别与确定表 主要污染源 现状监测及评价因子 评价因子 SO2、NO2、PM10、PM2.5、 环境空气 恶臭 CO、O3、H2S、NH3、臭气浓 H2S、NH3 度 地表水 医疗废水 生活污水 COD、BOD5、SS、氨 COD、氨氮、总磷、总氮 氮、动植物油、阴离子 表面活性剂、粪大肠菌 16 郸城县人民医院西南院区新建项目环境影响报告书 第二章总则 群数、肠道致病菌、肠 道病毒、结核杆菌 pH、氨氮、硝酸盐、亚硝酸 盐、挥发性酚、氰化物、 砷、汞、六价铬、总硬度、 氟化物、镉、铁、锰、溶解 医疗废水 地下水 性总固体、耗氧量、硫酸 生活污水 — 盐、氯化物、总大肠菌群、 细菌总数、阴离子表面活性 剂。Na+、K+、Ca2+、Mg2+、 CO32-、HCO3-、Cl-、SO42- 中央空调风冷热泵机组、污 噪声 固体废物 环境风险 水站风机、食堂风机、污水 站水泵、建筑物水泵、液氧 站空压机 医务后勤人员办公及宿舍产 生的普通生活垃圾、餐厨垃 圾、废反渗透膜、医疗废 物、污水站栅渣及污泥、废 紫外线含汞灯管 LAeq LAeq — — 危险源识别、环境风险 供氧站、医疗废物、污水处 液氧、柴油、次氯酸钠、化 分析、风险防范措施、 理站、 柴油罐 学试剂等。 应急预案等 2.4评价工作等级 2.4.1 大气环境评价工作等级及范围 (1)评价等级 根据《环境影响评价技术导则 大气环境》(HJ2.2-2018)的规定, 分别计算项目排放主要污染物的最大地面空气质量浓度占标率 Pi(第 i 个污染 物,简称“最大浓度占标率”),及第 i 个污染物的地面空气质量浓度达到标准 限值 10%时所对应的最远距离 D10%。其中 Pi 定义为: 式中:Pi—第 i 个污染物的最大地面空气质量浓度占标率,%; Ci—采用估算模型计算出的第 i 个污染物的最大 1h 地面空气质量浓度, μg/m3; 17 郸城县人民医院西南院区新建项目环境影响报告书 第二章总则 C0i—第 i 个污染物的环境空气质量浓度标准,μg/m3。 本项目采用以上计算模式进行估算,计算各污染物的最大地面占标率 Pi, 并按照评价工作等级判断依据确定评价工作等级,评价工作等级判据见表 2-3, 评价工作等级确定见表 2-4。 表 2-3 大气环境评价工作等级判据表 评价工作对等级 评价工作分级判据 一级 Pmax≥10% 二级 1%≤Pmax<10% 三级 Pmax<1% 表 2-4 评价工作等级的确定 最大地面浓度 污染源 污染物名称 出现的 最大地面浓 下风向距离 最大占 3 度(μg/m ) 标率% 评价等级 (m) 污水处理站 除臭系统排 气筒 H2S 77 0.01776 0.18% 三级 NH3 77 0.31925 0.16% 三级 根据《环境影响评价技术导则大气环境》(HJ2.2-2018),本项目大气环 境评价设定为三级,根据《环境影响评价技术导则 大 气 环 境 》 ( HJ2.2- 2018)的规定,本项目不进行进一步预测与评价,只对污染物排放量进行核算。 根据《环境影响评价技术导则大气环境》 (HJ2.2-2018) 中的要求, “三级评 价项目不需设置大气环境影响评价范围” 。本项目不设大气评价范围。 2.4.2 水环境评价工作等级及范围 (1)地表水环境评价工作等级及范围 本项目产生的废水主要为运营期产生的生活污水和医疗废水,项目建成后 总排水量为为 609.24m3/d,主要为 COD、BOD5 、SS、NH3-N、粪大肠菌群、 肠道致病菌、肠道病毒、结核杆菌,经院内地下污水处理站处理后排入市政污 水管网,经市政污水管网进入郸城县第三污水处理厂处理后排放,属于间接排 放。根据《环境影响评价技术导则 地表水环境》(HJ2.3-2018),本项 目属于评价等级为三级 B,可不进行水环境影响预测。 18 郸城县人民医院西南院区新建项目环境影响报告书 第二章总则 (2)地下水环境评价工作等级及范围 根据地下水环境影响评价工作分级划分原则,新建医院类报告书项目,三 甲类为Ⅲ类,其余为Ⅳ类项目。根据项目可研项目为三级医院,不属于三甲医 院,故本次环评按三级医院评定,IV 类项目。根据《地下水环境敏感程度分级 表》,IV 类项目可不进行地下水评价。 2.4.3 声环境评价工作等级及范围 (1)评价等级 根据《环境影响评价技术导则声环境》(HJ2.4-2021)建设项目所处的声 环境功能区为 GB3096 规定的 1 类、2 类地区,或建设项目建设前后评价范围内 声环境保护目标噪声级增量达 3dB(A)~5dB(A),或受噪声影响人口数量增加较 多时,按二级评价。本项目不在根据郸城县声环境功能区划图范围内(附图 11),项目位于县城郊区,本项目所在区域属于 1 类区,因此确定本项目声环 境评价等级为二级。 (2)评价范围 根据《环境影响评价技术导则声环境》(HJ2.4-2021),二级评价声环境 影响评价预测范围为厂界及 200m 范围内的环境敏感点。 2.4.4 土壤环境评价工作等级及范围 根据《环境影响评价技术导则土壤环境》(HJ964-2018)附录 A 表 A.1, 本项目属于“其他行业”,土壤环境影响评价项目类别为“Ⅳ类”,不需要进行土 壤环境影响评价。 2.4.5 生态环境评价等级 (1)评价等级 根据《环境影响评价技术导则 生态影响》(HJ19-2022)的要求,依据建 设项目影响区域的生态敏感性和影响程度,评价等级划分为一级、二级和三级。 按以下原则确定评价等级: 19 郸城县人民医院西南院区新建项目环境影响报告书 第二章总则 a)涉及国家公园、自然保护区、世界自然遗产、重要生境时,评价等级为 一级; b)涉及自然公园时,评价等级为二级; c)涉及生态保护红线时,评价等级不低于二级; d)根据 HJ2.3 判断属于水文要素影响型且地表水评价等级不低于二级的建 设项目,生态影响评价等级不低于二级; e)根据 HJ610、HJ964 判断地下水水位或土壤影响范围内分布有天然林、 公益林、湿地等生态保护目标的建设项目,生态影响评价等级不低于二级; f)当工程占地规模大于 20km2 时(包括永久和临时占用陆域和水域),评 价等级不低于二级;改扩建项目占地范围以新增占地(包括陆域和水域)确定; g)除本条 a)、b)、c)、d)、e)、f)以外的情况,评价等级为三级; h)当评价等级判定同时符合上述多种情况时,应采用其中最高的评价等级。 本项目占地不涉及国家公园、自然保护区、生态保护红线,项目不属于水 文要素影响型,不涉及天然林、公益林、湿地等保护目标,项目占地 65550m2 <20km2,可以确定项目的生态环境影响评价确定为三级。 (2)评价范围 根据评价区域与周边环境的生态完整性确定项目生态环境评价范围为项目 用地红线范围内。 2.4.6 环境风险评价等级 根据《建设项目环境风险评价技术导则》(HJ169-2018),本项目 Q<1, 该项目环境风险潜势为Ⅰ,确定本项目的环境风险评价等级为简单分析。本项 目环境风险评价等级划分见表 2-5。 表 2-5 本项目环境风险评价工作等级划分 环境风险潜势 Ⅳ、Ⅳ+ Ⅲ Ⅱ Ⅰ 评价工作等级 一 二 三 简单分析a a是相对于详细评价工作内容而言,在描述危险物质、环境影响途径、环境危害后果、风险防范措施 等方面给出定性的说明。见附录A。 20 郸城县人民医院西南院区新建项目环境影响报告书 第二章总则 根据表 2-5,本项目环境风险只需进行简单分析。 2.5污染控制与环境保护目标 根据对项目周围环境状况的调查及污染因素的分析,确定项目污染控制内 容详见表 2-6,环境保护目标详见表 2-7。 表 2-6 工程污染控制内容一览表 污染物 污染控制内容 控制因子 控制目标 COD、 《医疗机构水污染物排放标准》 BOD5、SS、 (GB18466-2005)表1传染病、结 废水 医疗废水、生活污水 氨氮、粪大肠 核病医疗机构水污染物排放浓 菌群、肠道致 度、最高允许排放负荷标准要求 病菌、肠道病 及郸城县第三污水处理厂设计进 毒、结核杆菌 水水质要求 病区含菌废气采用紫外线杀毒后 经专用排风烟道引至楼顶排放; 手术室、负压病房采用全新风直 含菌废气 细菌 流式空调系统,送风应经过初 效、中效、高效过滤器三级处 理,排风经过高效过滤器过滤处 理后经过专用排风烟道引至楼顶 废气 排放 检验废气 有机废气 油烟、非甲烷 食堂油烟 总烃 汽车尾气 碳氢化物 污水处理站、生活垃圾 H2S、NH3、臭 站产生的恶臭 气浓度 备用柴油发电机废气 设备噪声 河南省地方标准《餐饮业油烟污 染物排放标准》(DB41/16042018)大型 对周边环境影响较小 《恶臭污染物排放标准》 (GB14554-93)表2标准 周围环境影响较小 等效连续A声 噪声 对周边环境影响较小 级 LAeq 《工业企业厂界环境噪声排放标 准》(GB12348-2008)1类、4类 垃圾收集站95m2、垃圾桶、垃圾 固废 医务后勤人员办公及宿 舍产生的普通生活垃圾 箱。生活垃圾分类收集后,日产 —— 日清,每天由环卫部门负责清运 至市政垃圾中转站,最终运至郸 城县生活垃圾焚烧厂发电厂焚烧 21 郸城县人民医院西南院区新建项目环境影响报告书 第二章总则 采用专用餐厨垃圾收集桶收集, —— 餐厨垃圾 集中收集后交由有资质的单位进 行运输处 置 废反渗透膜(纯水制 备) 更换后随生活垃圾一同交环卫部 —— 门清运处理 医疗废物(门诊、病房 楼病人产生的生活垃 医疗废物暂存间50m2暂存后,委 —— 托有资质单位进行集中处理 圾) 污水处理站产生的污 泥、栅渣 消毒脱水(污泥脱水间30m2)后 暂存危废暂存间25m2,作为危险 —— 废物定期交有资质单位处置 废紫外线含汞灯管 危废间25m2暂存交由有资质单位 —— 处置 表 2-7 本项目 500m 范围内大气环境保护目标及保护级别 地理位置坐标 环境 要素 /m 保护 名称 经度 纬度 115.14 33.63 27329 43064 8 5 115.14 33.62 85007 99058 环境 7 8 空气 115.14 33.62 36534 60213 3 4 115.14 33.62 68083 89009 3 2 丁寨 张柿园 何老家 郸城县 气象局 对象 人口分 布 环境功能区 (人) 居民 1554 居民 357 《环境空气质量标 相对厂 址方位 相对 距离 /m 北侧 178 东侧 254 南侧. 350 东南侧 144 准》GB3095-2012) 居民 行政 办公 642 二级 40 项目厂界周边 200m 范围内不存在声环境保护目标。 表 2-8 地表水环境保护目标调查表 环 地理位置 保 境 名 坐标/m 护 人口分布 要 称 经 纬 对 (人) 度 度 象 素 环境功能区 22 相对场 址方位 相对 距离 /m 郸城县人民医院西南院区新建项目环境影响报告书 地 表 水 洺 河 / 河 / 《地表水环境质量标准》 / 流 第二章总则 (GB3838-2002))V类标准 东北侧 3367 2.6评价标准 2.6.1 环境质量标准 根据附图 11 郸城县城区声环境功能区划图,公园西路道路边界外 4a 类声 环境功能区距离为 50m。项目东厂界距离公园西路道路边界 30m,故东厂界执 行 4a 类、南、西、北厂界执行 1 类。 本次评价执行以下环境质量标准。 表 2-9 评价执行的环境质量标准一览表 环境 标准名称及级 要素 (类)别 环境 项 目 标准限值 PM10 年平均 70μg/m3 《环境空气质量标 NO2 年平均 40μg/m3 准》 SO2 年平均 60μg/m3 (GB3095-2012)二 PM2.5 年平均 35μg/m3 级 CO 24小时平均 4mg/m3 O3 日最大8小时平均 160μg/m3 空气 NH3 200μg/m3 H2S 10μg/m3 《地表水环境质量 COD 40mg/L 标准》(GB3838- 氨氮 2.0mg/L 2002)V类 总氮 0.4mg/L 《环境影响评价技 术导则 大气环境》(HJ2.22018)附录D 水环境 《声环境质量 声环境 标准》 1类 (GB3096- 4a 2008) 类 地下水质量标准 地下水 (GB/T148482017)Ⅲ类 等效声级 等效声级 昼间55dB(A) 夜间45dB(A) 昼间70dB(A) 夜间55dB(A) pH 6.5-8.5 氟化物 1.0mg/L 锰 0.10mg/L 硫酸盐 250mg/L 硝酸盐 20.0mg/L 氯化物 250mg/L 耗氧量 (高锰酸盐指数) 23 3.0mg/L 郸城县人民医院西南院区新建项目环境影响报告书 第二章总则 总硬度 450mg/L 氨氮 0.50mg/L 溶解性总固体 1000mg/L 亚硝酸盐 1.00mg/L (N) 挥发酚 0.002mg/L 砷 0.01mg/L 铁 0.3mg/L 六价铬 0.05mg/L 氰化物 0.05mg/L 镉 0.005mg/L 汞 0.001mg/L 细菌总数 100CFU/mL 总大肠菌群 3CFU/100mL 阴离子表面活性剂 0.3mg/L 2.6.2 污染物排放标准 表 2-10 评价执行的污染物排放标准 污染物 标准名称及级(类)别 污染因子 标准限值 粪大肠菌群 100个/L 肠道致病菌 不得检出 肠道病毒 不得检出 结核杆菌 不得检出 pH 6-9 COD 《医疗机构水污染物排放标 BOD5 准》(GB18466-2005)表1传染 病、结核病医疗机构水污染物 SS 排放浓度、最高允许排放负荷 废 标准要求 水 60mg/L,最高允许排放负荷60g/ 床位﹒d 20mg/L,最高允许排放负荷20g/ 床位﹒d 20mg/L,最高允许排放负荷20g/ 床位﹒d 氨氮 15mg/L 动植物油 5mg/L 阴离子表面活 性剂 5mg/L 6.5-10mg/L 总余氯 (接触池出口,消毒接触池 ≧1.5h) 郸城县第三污水处理厂进水水 质要求 24 PH 6~9 COD 500mg/L BOD5 200mg/L 氨氮 35mg/L SS 300mg/L 郸城县人民医院西南院区新建项目环境影响报告书 NH3 《恶臭污染物排放标准》 (GB14554-93)表2标准(20m高 H2 S 排气筒) 废气 臭气浓度 河南省地方标准《餐饮业油烟 油烟 污染物排放标准》 期 噪声 有组织8.7kg/h 无组织1.5mg/m3 有组织0.58kg/h 无组织0.06mg/m3 有组织2000(无量纲) 无组织20(无量纲) 1.0mg/m3 油烟净化设施去除效率95% 非甲烷总烃 10.0mg/m3 等效声级 昼70dB(A),夜55dB(A) 1类 等效声级 昼55B(A),夜45B(A) 4类 等效声级 (DB41/1604-2018)(大型) 施工 第二章总则 《建筑施工场界环境噪声 排放标准》(GB125232011) 《工业企业厂界 运营 环境噪声排放标 期 准》(GB12348- 昼70B(A),夜55B(A) 2008) 《一般工业固体废物贮存和填埋污染控制标准》(GB18599-2020) 固废 《危险废物贮存污染控制标准》(GB18597-2023) 《医疗机构水污染物排放标准》(GB 18466-2005)表4 医疗机构污泥控制标准 2.7工程和环境特点 2.7.1 工程特点 (1)本项目属于鼓励类项目,项目的建设符合国家有关的产业政策。 (2)郸城县人民医院为三级综合医院,本项目西南院区的设施均不依托老 院区,西南院区建成后两个院区分别独立运行。本项目医院按照传染病医院的 要求进行建设。项目设有 1 栋发热门诊、1 栋呼吸道病房楼,发热门诊楼和呼 吸道病房楼内设置空气传播传染病房,其他病床设为非空气传播传染病房。医 院南部病房楼平时作为非空气传播传染病房使用,疫情时作为隔离病房使用。 (3)项目病房楼制冷供暖采用分体空调;宿舍楼采用一拖多多联机,室外 采用风冷换热形式;门诊楼、呼吸道楼、发热门诊、后勤办公综合楼各设 1 套 中央空调风冷热泵机组设于楼顶。热水采用电热水器,消毒蒸汽采用电蒸汽发 生器制备。项目不设置锅炉、不设冷却塔。 (4)项目废水包括病区医疗废水(化验室废水、门诊废水、 住院病房废 水、 医务人员废水、空调冷凝水、蒸汽消毒废水、病区食堂废水)、非病区废 水(后勤办公人员废水、宿舍楼、普通食堂、空调冷凝水);废气包括病区含 25 郸城县人民医院西南院区新建项目环境影响报告书 第二章总则 菌废气、检验废气、食堂油烟、汽车尾气、污水站恶臭、垃圾站恶臭、备用柴 油发电机废气;项目噪声主要是空调风冷热泵、水泵及污水站风机、食堂风机、 液氧站空压机等噪声;项目固废主要是医务后勤人员办公及宿舍产生的普通生 活垃圾、餐厨垃圾、废反渗透膜(纯水制备)、门诊病房楼病人产生的生活垃 圾(属于医疗废物)、医疗废物、污水站栅渣及污泥、废紫外线含汞灯管。该 部分内容的工程分析、环境影响预测与评价、环保措施及其可行性论证为本次 评价的工作重点。 (5)本次评价不包括辐射有关内容的评价,辐射内容需另行评价。 2.7.2 环境特点 (1)本项目选址位于郸城县科技大道北、公园西路西侧地块,周边为农田 和村庄,环境相对安静,且周边区域无污染源,不临近幼儿园、学校等人员密 集的公共设施或场所(距离西侧学校巴集五七高中 870m,距离较远)。厂界距 离北侧最近敏感点 178m,医院医疗建筑物距离东南侧郸城县气象局构筑物 144m,满足《传染病医院建筑设计规范》(GB50849-2014)中 20m 绿化隔离 卫生间距的要求。符合《传染病医院建筑设计规范》(GB50849-2014)中选址 要求“医疗用建筑物与院外周边建筑应设置大于或等于 20m 绿化隔离卫生间 距”。项目不属于人口密集区域,项目建设符合《传染病医院建设标准》(建 标 173-2016)的相关要求。 (2)本项目位于郸城县科技大道北、公园西路西侧地块,东侧紧临公园西 路(已铺设污水管网),医院废水经医院污水处理设施处理后通过市政管网排 入郸城县第三污水处理厂集中处理后,达标排放;地下污水处理站恶臭采取生 物除臭+紫外线消毒装置处理措施;食堂油烟经高效静电式油烟净化器处理后专 用烟道排放。 (3)根据现场调查厂址周围 500m 范围内没有集中饮用水源保护区、自然 保护区风景名胜区和文物保护单位等其它环境敏感目标。 2.8评价总体思路及评价重点 26 郸城县人民医院西南院区新建项目环境影响报告书 第二章总则 对拟建项目评价遵循“清洁生产、达标排放、总量控制”的原则,进行全面、 科学、客观的评价。 (1)医院建设项目在污水和固废处理方面均有成熟可靠的污染治理技术。 针对项目特点,强化污染防治措施可行性的评价工作,最大限度地控制污染, 实现污染物的达标排放或安全处置。 (2)本次评价以以“达标排放、总量控制、资源利用”为原则,充分利用已 有可靠资料,采用类比调查等方法确定废水、废气、噪声、固体废物产排源强。 (3)对环境现状进行实际调查,了解评价区域的环境质量现状及存在的主 要环境问题。 (4)根据本项目污染物排放源强,在区域环境质量现状的基础上,预测本 工程建成投产后,污染物排放对区域环境空气、地表水、声环境等的影响程度 和范围,对地下水环境进行简要分析。 (5)针对工程中存在的污染事故进行环境风险评价。 (6)综合工程建设环境评价结论,从环境保护角度明确工程建设及选址的 环境可行性。 2.9专题设置 本次评价设置以下专题: (1)概述 (2)总则 (3)工程分析 (4)环境现状调查与评价 (5)环境影响预测与评价 (6)环境保护措施及可行性分析 (7)环境经济损益分析 (8)产业政策相符性及厂址可行性分析 (9)环境管理与监测计划 (10)环境影响评价结论 27 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 第三章工程分析 3.1建设项目概况 3.1.1 本项目基本情况 本项目的基本情况见表 3-1。 表 3-1 本项目基本情况一览表 序号 项目 内容 1 项目名称 郸城县人民医院西南院区新建项目 2 建设单位 郸城县人民医院 3 建设性质 新建 4 建设地点 郸城县科技大道北、公园西路西侧地块 5 总用地面积 65550m2 6 总建筑面积 107656m2 7 项目总投资 63480万元 8 建设内容 项 目 共 设 置 床 位 800 张 , 总 占 地 65550m2 , 总 建 筑 面 积 107656m2,其中地上建筑面积 75501m2,地下建筑面积 32155m2,其 中建筑物包括:4 栋 4F 病房楼(建筑面积 26107m2,疫情时作为隔离 病房使用)、1 栋 5F 宿舍楼(建筑面积 4811m2,疫情时作为医护人 员 宿 舍 ) 、 1 栋 4-10F 门 诊 医 技 传 染 病 综 合 楼 ( 建 筑 面 积 24810m2),1 栋 5F 呼吸道病房楼(建筑面积 7447m2),1 栋 4F 后 勤办公综合楼(建筑面积 8840m2 )、1 栋 2F 发热门诊(建筑面积 2178m2 )。设置机动车车位 1140 个。同时配套道路、绿化、变配 电、给排水、污水处理系统等附属设施。 9 容积率 1.152 10 建筑密度 35% 11 车位数 1140个 12 建设规模 800张床位 13 工作制度 年工作日365天,三班工作制,每班8小时 14 劳动定员 1200人 15 门诊量 2400人次/日 3.1.2 本项目组成及建设规模 项目总建筑面积 107656m2,编制床位 800 张,包括主体工程、公用工程、 环保工程等。项目主要建设内容见表 3-2,本评价对象不包括辐射有关内容评价。 28 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 表 3-2 医院总工程主要建设内容 主体 工程 项目名称 项目规模 总建筑面积(m2) 107656 地上总建筑面积(m2) 75501 其中 4栋4F病房楼 26107 5F宿舍楼 4811 4-10F门诊医技传染病综合楼 24810 5F呼吸道病房楼 7447 4F后勤办公综合楼 8840 2F发热门诊 2178 变配电所 710 氧气站 78 配套用房(医疗废物间、危废 间 、生活垃圾站) 520 地下总建筑面积(m2) 32155 机动车位(辆) 1140 处理规模710m3/d(预处理+格栅 医院总污水处理站 +调节池+水解酸化+接触氧化 +MBR膜池+次氯酸钠消毒+脱氯 池) 后勤办公综合楼食堂油水分 离器 废水 环保 工程 非病区普通化粪池 处理能力22m3/d 35m3/d(容积1个30m3、1个 60m3) 病区中和池 容积7m3 病区食堂油水分离器 处理能力180m3/d 病区专用化粪池+臭氧预消 430m3/d(容积1个450m3、1个 毒池 100m3、1个45m3、1个500m3) 车辆洗消废水消毒池 容积10m3 病区含菌废气采用紫外线杀毒后经 专用排风烟道引至楼顶排放;手术 室、负压病房采用全新风直流式空 废气污染防治设 含菌废气 调系统,送风应经过初效、中效、 高效过滤器三级处理,排风经过高 施 效过滤器过滤处理后经过专用排风 烟道引至楼顶排放 检验废气 29 经安全柜配套高效空气过滤器处理 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 后去除致病细菌、生物气溶胶及其 他污染物有害气体后,再引至楼顶 排放,同时医院做好检验室内的消 毒卫生工作,确保检验废气处理后 不会对周围环境造成明显影响 经1套高效静电式油烟净化器处理 后勤办公综合楼食堂油烟 后经烟道引至后勤办公综合楼楼顶 排放 经1套高效静电式油烟净化器处理 门诊医技综合楼食堂油烟 后经烟道引至门诊医技综合楼楼顶 排放 道路两侧加强绿化,地下车库设置 泊车位汽车尾气 抽排风系统,及时疏导进出泊车位 车辆 1套负压抽吸+生物除臭+紫外线消 地下污水处理站恶臭 毒后经管道引至附近病房楼楼顶排 放(20m) 危废间废气 经管道引至污水站恶臭措施处理排 放 仅收集,不处理不压缩。垃圾袋 生活垃圾收集站恶臭 装化,减少垃圾暴露时间,及时 清运,日产日清,使用除臭剂 备用柴油发电机燃烧废气 噪声污染防治设 施 消声、减振、隔声等措施 经自带的净化装罝处理后,通过 专用烟道引至楼顶排放 / 垃圾收集站95m2、垃圾桶、垃圾 医务后勤人员办公及宿舍产生 的普通生活垃圾 箱。生活垃圾分类收集后,日产日 清,每天由环卫部门负责清运至市 政垃圾中转站,最终运至郸城县生 活垃圾焚烧厂发电厂焚烧 固体废物 采用专用餐厨垃圾收集桶收集,集 餐厨垃圾 中收集后交由有资质的单位进行运 输处 置 废反渗透膜(纯水制备) 更换后随生活垃圾一同交环卫部门 清运处理 医疗废物(门诊、病房楼病人 医疗废物暂存间50m2暂存后,委托 产生的生活垃圾) 30 有资质单位进行集中处理 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 消毒脱水(污泥脱水间30m2)后暂 污水处理站产生的污泥、栅渣 存危废暂存间25m2,作为危险废物 定期交有资质单位处置 更换后暂存于危废暂存间25m2内, 废紫外线含汞灯管 定期交由有资质单位处置 给水 生活、医疗用水水源均为市政自来水 排水 雨污分流,污污分流,分别设置雨水、污水管网 病房楼制冷供暖采用分体空调;宿舍楼采用一拖多多联机,室外 公用 工程 采用风冷换热形式;门诊楼、呼吸道楼、发热门诊、后勤办公综 供热 合楼各设1套中央空调风冷热泵机组设于楼顶,采用风冷省去了 水冷冷水机组的冷却水系统。热水供应采用电热水器 供电 郸城县电业局 表 3-3 项目化粪池设置位置及大小 日排放废水量m3/d 化粪池设 置位置 门诊医技 种类 废水量 门诊废水(75%) 57.6 病床病人废水 传染病综 合楼 合计 75.52 (29.5%) 医务人员(53%) 9.54 门诊废水(15%) 11.52 呼吸道病 病床病人废水 房楼 (6.25%) 16 医务人员(10%) 1.8 门诊废水(10%) 7.68 病床病人废水 发热门诊 4.48 (1.75%) 病床病人废水 后勤办公 综合楼 160 (62.5%) 粪池容 粪池大 积m3 小m3 142.66 36h 427.98 450 29.32 36h 87.96 100 13.42 36h 40.26 45 165.4 36h 496.2 500 医务人员(30%) 5.4 后勤管理人员废水 9.6 9.6 36h 28.8 30 宿舍废水 19.2 19.2 36h 57.6 60 宿舍楼 表 3-4 构筑物名称 4栋4-5F病房楼 (500张病床) 1栋5F宿舍楼 停留时间 设置化 1.26 医务人员(7%) 病房楼 m3/d 所需化 层数 建筑面积 4F 26107 5F 4811 主要构筑物设置情况 功能布局 按照方舱医院隔离点标准建设,平时做非呼 吸道传染病房使用,疫情时用作隔离点。 平时作为职工宿舍,疫时作为隔离点医务人 31 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 员宿舍 一层主要是住院办理、急诊、药房、急诊大 厅、住院办理、影像科,二层为全科门诊、 1栋门诊医技综合 楼(236张、84个 4-10F 预防保健、功能检查及消毒供应,三层设手 24810 术部、病理科、检验科、PCR科,四层为 病房) ICU、产房和手术部净化机房、五-十层为传 染病病房 一层设置导医接诊、彩超、心电、诊室、标 1栋呼吸道病房楼 (50张病床,留 观病房单人间, 本采集室、抢救室、治疗室、处置室、挂号 3 7447 收费、检验、药房、单人间留观病房、办公 室、档案室、CT室、DR室等。二-五层设置 或两人间) 办公室、治疗室、值班室、双人间病房、 1栋后勤办公综合 楼 4 设有会议室、职工活动中心、办公室、资料 8840 室等 主要设置发热门诊和肠道门诊。一层设置挂 1栋发热门诊楼 2 (14张留观 号、检验室、抢救室、控制室、标本采集、 2178 诊室、候诊区等。二层出入院登记、更衣 病床,单人间) 区、治疗室、留观病房14个、库房等。 3.1.3 科室设置 门诊医技综合楼主要设置内科、外科、妇科、儿科、病理科、影像科、检 验科、肝炎门诊、艾滋病门诊及手术室等综合科室。综合楼五-十层为传染病病 房。 发热门诊楼主要设置发热门诊和肠道门诊。肠道门诊主要是排除和治疗感 染性腹泻。发热门诊对不明原因的发热患者进行检查、鉴别诊断、治疗等,筛 查后转到相应科室住院。呼吸道病房楼主要用于治疗呼吸道感染类的疾病患者, 一般采用负压病房。 3.1.4 主要设备及原辅料 本项目主要设备见表 3-5。 表 3-5 序号 设备名称 主要设备一览表 单位 数量 备注 病区 1 除颤监护仪 台 9 / 2 多参数监护仪 台 12 / 32 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 3 多功能心肺复苏机 台 12 / 4 呼吸机 套 75 / 5 监护仪 台 102 / 6 监护仪主机 台 12 / 7 可视喉镜 台 12 / 8 空气波压力治疗系统 台 30 / 9 空气消毒机 台 69 / 10 颅脑降温仪 台 18 / 11 微量注射泵 (双) 台 66 / 12 微量注射泵 (单) 台 51 / 13 纤维支气管镜 台 12 / 14 消毒机 台 12 / 15 心电图机 台 15 / 16 血气分析仪 台 12 / 17 营养泵 台 30 / 18 振动排痰机 台 21 / 19 转运呼吸机 台 12 / 套 6 / 20 ECMO (人工心肺) 22 视频探视系统 套 3 16 转信息系统 23 光子治疗仪 台 3 / 血液净化设备 24 血液滤过机 台 6 / 25 持续徐缓式血液净化装置 台 3 / 26 血液透析机 台 69 / 27 空气消毒机 台 12 / 28 持续徐缓式血液净化装置 台 6 / 29 除颤仪 台 3 / 30 血透机检测仪 台 3 / 31 ACT 测试仪 台 3 / 32 红外治疗仪 台 3 / 33 壁挂式紫外线空气消毒机 台 24 / 34 输液泵 台 30 / 介入科 35 微量注射泵 台 6 / 36 平板探测器血管造影系统 套 3 / 37 空气消毒机 台 21 / 38 监护仪 台 6 / 39 微量注射泵 台 3 / 40 麻醉机 台 3 / 手术室 45 麻醉车 台 6 / 46 HP 除颤器 台 3 / 33 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 47 HP 插件式监护仪 台 6 / 48 关节镜 台 3 / 49 电动手术床 台 12 / 50 消毒架 台 3 / 51 超声刀 台 3 / 52 多功能杀菌车 台 9 / 53 手术显微镜 台 3 / 54 无菌车 台 3 / 55 超声波清洗机 台 3 / 56 高频电刀 台 18 57 自动气压止血仪 台 3 美威力 / 58 微量注射泵 台 18 / 59 高温培养箱 台 3 / 60 卡式压力蒸汽灭菌器 台 3 / 61 气压止血仪 台 3 / 62 妇科电刀工作站 套 3 / 63 麻醉机 台 9 / 64 手术对接车 台 18 / 65 脊柱微创手术系统 套 3 / 66 微量注射泵 台 30 北京思路高 67 腹腔镜 台 3 德国史托斯 68 卡式灭菌器 台 3 69 电子腹腔镜系统 套 3 加拿大 / 70 多导联心电分析系统 套 3 71 充气升温装置 套 3 18 导同步心电图 / 72 可视喉镜 套 3 / 73 麻醉塔 台 18 / 74 麻醉工作站 套 9 75 手术无影灯 套 3 德国 Draeger / 76 LED 双母无影灯带显示屏挂臂 台 9 / 77 移动式 G 型臂 X 射线成像系统 套 6 / 78 纤维胆道镜 台 3 / 消毒供应中心 79 脉动真空灭菌器 4 台 使用寿命 15 年/30000 次灭菌循环。 通过过氧化氢低温等离子体进行灭 80 过氧化氢低温等离子体灭菌器 2 台 菌,消毒过程中通过特定方式使医 疗器械和手术器械上的多种微生物 失去活性,从而达到灭菌目的 负压工作系统,具有泄漏自动监测 81 环氧乙烷灭菌器 台 1 82 纯水处理系统 套 1 双极反渗透 83 内镜清洗设备 套 2 设备具备管道自身消毒功能 34 系统,配环境浓度监测报警系统。 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 84 医用干燥柜 台 1 / 85 真空干燥柜 台 1 / 病理科 86 1.8 米直排式双面取材台 个 4 87 专业病理标本存放柜 个 10 88 病理废液回收系统 套 1 89 全自动生物样本真空转移系统 套 1 90 移动空气消毒机 台 4 具有大体摄像、冷热水、紫外消 毒、下排风、上新风功能 常温标本存放柜 8 个,4º冷藏标本柜 2 个。均有排风功能。 / 具有低温冷藏、真空、 自动加固定 液、自动封袋等功能 紫外线消毒 高速冷冻离心机 2 台,高速离心机 2 91 离心机 10 台 台,低速离心机 2 台,普通离心机 4 台 92 纯水制水机 台 1 反渗透净化 93 生物安全柜 个 4 / 94 气体净化系统 套 1 含排风、新风、离子净化功能 医学检验科 95 PCR 实验室 座 1 96 压力蒸汽灭菌器 台 3 / 97 离心机 台 15 / 98 生物安全柜 台 10 / 99 血细胞分析仪 台 4 / 100 尿液分析仪 台 4 / 101 酶标仪 台 4 / 102 凝血功能分析仪 台 4 / 103 发光分析仪 台 3 / 104 生化类分析仪 台 3 / 105 全自动智能染色体核型分析 台 1 / 医学影像中心 106 320 排螺旋 CT 机 台 1 107 16 排螺旋 CT 机 台 3 108 1.5TMRI 台 1 109 3.TMRI 台 1 110 移动 DR 台 2 病房楼 111 数字胃肠机 台 1 病房楼 112 DR 机 台 2 影像中心 113 彩色 B 超 台 1 超声介入科 114 便携式超声诊断系统 台 2 115 彩色超声全身机 台 1 116 彩色超声妇产机 台 1 117 彩色超声心脏机 台 1 非医疗设备 35 医学影像 CT 室 医学影像 MRI 室 超声科 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 118 病房楼分体空调 套 119 宿舍楼一拖多多联机 套 约 400 5 120 中央空调风冷热泵机组 套 4 121 柴油发电机 台 2 122 电热水器 台 28 表 3-6 序号 设置在传染病病房楼、呼吸道病房 楼、门诊楼、发热门诊楼病房 设置在宿舍楼 设置在门诊楼、呼吸道楼、发热门 诊、后勤办公综合楼 位于地上一层柴油发电机房(紧临 配电房),两台均为 1000kVA,配 套 1 个 1t 柴油罐 于门诊及病房楼各层设置开水间, 采用 电热水器供应饮用热水 污水处理站主要设备设施一览表 名称 型号及规格 单位 数量 1 格栅井 机械格栅 HF— 1500 ,δ=10mm 台 1 2 初沉池 排泥泵 20m 3 /h ,2.2kW 台 2 3 调节池 静压式液位计 0-5m 套 1 污水提升泵 50m 3 /h ,5.5kW 台 2 生物填料 Ø150×3500mm 套 1 布水装置 / 套 1 曝气系统 / 套 1 生物填料 Ø150×3500mm 套 2 微孔曝气器 / 套 4 混合液回流泵 100m 3 /h ,7.5kW 台 2 应急提升泵 50m 3 /h ,5.5kW 台 2 排泥泵 20m 3 /h ,2.2kW 台 2 套 1 4 5 水解酸化池 接触氧化池 6 二沉池 总面积 5000m ,膜架 2 MBR 膜组件 7 MBR 膜池 8 接触消毒池 9 脱氯池 SS304 抽吸泵 65m 3 /h ,7.5kW 台 2 污泥泵 30m 3 /h ,3kW 台 2 反洗泵 100m /h ,7.5kW 台 1 鼓风机 17.63m 3 /min ,22kW 台 3 膜清洗装置 / 套 1 管道混合器 Ø40 ,PVC 套 2 出水提升泵 50m 3 /h ,5.5kW 台 2 脱氯加药装置 / 套 1 搅拌装置 框式搅拌 套 1 板框压滤机 2 过滤面积 30m ,P= 1.5kW 套 1 污泥螺杆泵 P=4kW 台 2 污泥调理加药泵 Q=100L/h ,P=0. 15kW 台 2 除磷加药装置 / 套 1 搅拌装置 框式搅拌 套 1 3 10 污泥处理间 11 污泥池 12 加药间 13 消毒设备间 次氯酸钠水射器 3000g/h 台 2 14 在线监测 流量计 / 套 1 36 郸城县人民医院西南院区新建项目环境影响报告书 15 第三章工程分析 风机 2000m 3 /h 台 1 紫外线消毒仪 / 台 1 生物滤池除臭装置 / 套 1 风机间 本项目部分原辅材料消耗情况一览表见下表。 表 3-7 类别 名称 年耗量 备注 一次性空针、输液管 约 50万具 外购成品,存放仓库 一次性中单、小单 约22万张 外购成品,存放仓库 一次性手套 约 55万双 外购成品,存放仓库 一次性尿带、尿管 约 2.5万套 外购成品,存放仓库 其它一次性耗材 75t 外购成品,存放仓库 1250份 外购成品,存放仓库 乙肝表面抗体试剂盒 5000份 外购成品,存放仓库 乙肝抗原试剂盒 5000份 外购成品,存放仓库 5000 份 外购成品,存放仓库 5000份 外购成品,存放仓库 5000 份 外购成品,存放仓库 西药 100万盒 外购成品,存放药房 0.9%氯化钠注射液 15万瓶 外购成品,存放药房 5%葡萄糖注射剂 5万瓶 外购成品,存放药房 碘伏 7.5t 人类免疫缺陷病毒 医疗 器械 HIV 抗体试剂盒 结核杆菌 IgG 抗体检 测 试剂盒 结核杆菌蛋白抗原试 剂盒 肠道病毒 RT-LANP 试 剂盒 戊二醛消毒剂(1.8- 外购成品,塑料瓶装,有 500ml 和 60ml 两种 规格 2.5t 外购成品,塑料瓶装,每瓶 2.5L 双氧水 0.1125t 外购成品,密封瓶装,每瓶 500ml, 甲醇 0.2t 外购成品,密封瓶装,每瓶 500ml 甲醛(福尔马林) 0.5t 外购成品,密封瓶装,每瓶 500ml ,检验科用 84 消毒液 10t 酒精 (95%) 0.5t 外购成品,密封瓶装,每瓶 2000ml 酒精 (75%) 17.5t 外购成品,密封瓶装,每瓶 2000ml 无水乙醇 12.5t 外购成品,密封瓶装,每瓶500ml,用于化验 盐酸(浓度37%) 0.5t 外购成品,密封瓶装,化验室用 2.2%) 其他 工程部分原辅材料消耗情况一览表 外购成品,主要有效成分为次氯酸钠,密封瓶 装,每瓶 500ml ,用于病房地面,台面消毒 37 郸城县人民医院西南院区新建项目环境影响报告书 污水 处理站 能耗 第三章工程分析 氢氧化钠 0.5t 外购成品,密封瓶装,化验室用 硫酸 (98%) 0.75t 外购成品,密封瓶装,化验室用 二甲苯 0. 25t 外购成品,密封瓶装,化验室用 DAB 染色液 0.125t 外购成品,密封瓶装,化验室用 液体石蜡 0.2t 外购成品,密封瓶装,化验室用 液氧 300m3 外购成品,液氧罐储存,每瓶 5m3,存放3瓶 次氯酸钠 8.55t 污水站使用,密封桶装,每桶25公斤,存放8桶 聚丙烯酰胺 1.25t 污水处理站污泥浓缩用,密封袋装,每袋 50kg 硫代硫酸钠 1.25t 污水处理站脱氯用,密封袋装,每袋25公斤, 存放2袋 740万 电 市政供电 W ·h/a 287333m3/a 水 供水管网提供 本项目主要原辅材料理化特性见下表。 表 3-8 项目主要原辅材料理化性质 名称 理化性质 碘伏 碘伏是单质碘与聚乙烯吡咯烷的不定型结合物。医用碘伏呈现浅棕色。 戊二醛消 毒剂 戊二醛是一种 5 碳双缩醛化合物,即 1.5 戊二醛,无色透明液体含量为 1.8%— 2.2% ,具 有广谱、高效、快速、腐蚀性小,水溶液比较稳定的优点, 由于戊二 醛对细菌繁殖体, 芽孢分枝杆菌,真菌和病毒均有杀灭作用。 水溶液为无色透明液体,有微弱的特殊气味。纯过氧化氢是淡蓝色的油状液体。 双氧水 熔点 -0.89℃(无水) ,沸点 152. 1℃(无水) ,相对密度(水=1) :1.46(无水) ,饱和 蒸气压(kPa): 0. 13( 15.3℃) ,能与水、乙醇或乙醚以任何比例混合。不溶于苯、 石油醚。 是无色有酒精气味易挥发的液体,熔点-97℃ ,沸点 64.7 ,闪点 11℃ ,密度为 甲醇 0.7918。 易燃,其蒸汽与空气可形成爆炸性混合物。遇明火、高热能引起燃烧爆 炸。 气体相对密度 1.067 (空气=1) ,液体密度 0.815g/cm3 。熔点-92℃ ,沸点- 甲醛 19.5℃ ,易溶 于水和乙醇。水溶液的浓度最高可达 55% ,通常是 40% ,是有刺 激气味的无色液体。有 强还原作用。能燃烧,蒸汽与空气形成爆炸性混合物,爆 炸极限 7-73% ,着火温度约 300℃。 84 消毒 以次氯酸钠为主要有效成分,含量约为 5.5-6.5% 。该品不燃,具有腐蚀性,可致 液 人体灼 伤。 无色液体,有酒香;与水混溶,可混溶于醚、氯仿、甘油等多数有机溶剂;用于 酒精(乙 制酒工 业、有机合成、消毒 以用作溶剂。易燃,其蒸气与空气可形成爆炸性混 醇) 合物。遇明火、 高热能 引起燃烧爆炸。与氧化剂接触发生化学反应或引起燃 烧。 盐酸 分子式 HCl ,相对分子质量 36.46 。盐酸为不同浓度的氯化氢水溶液,呈透明无 色或黄 色,有刺激性气味和强腐蚀性。易溶于水、乙醇、乙醚和油等。 38 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 也称苛性钠、烧碱、火碱,是一种无机化合物,化学式NaOH,白色结晶性粉 氢氧化钠 末,密度2.13g/cm3,易溶于水、乙醇、甘油,不溶于丙酮、乙醚,氢氧化钠具有 强碱性,腐蚀性极强,可作酸中和剂、配合掩蔽剂、沉淀剂、沉淀掩蔽剂、显色 剂、皂化剂、去皮剂、洗涤剂等,用途非常广泛。 分子式 H2SO4 ,一种最活泼的二元无机强酸,能和许多金属发生反应。高浓度的 硫酸有 强烈吸水性,与水混合时,亦会放出大量热能。其具有强烈的腐蚀性和氧 硫酸 化性。是一种 重要的工业原料,可用于制造肥料、药物、炸药、颜料、洗涤剂、 (98%) 蓄电池等,也广泛应 用于净化石油、金属冶炼以及染料等工业中。常用作化学试 剂,在有机合成中可用作脱 水剂和磺化剂。无色粘稠状液体,有强腐蚀性,有刺激 性气味, 易溶于水,生成稀硫酸。 为无色透明液体,有芳香烃的特殊气味。能与无水乙醇、乙醚和其他许多有机溶 二甲苯 剂混溶, 几乎不溶于水。相对密度约 0.86 ,沸点 137℃ ,闪点小于 28℃ 。易 燃,蒸汽能与空气形 成爆炸性混合物,爆炸极限约为 1-7% 。低毒。 DAB 染色液用于免疫组化染色,应用 Dako 自动染色系统上。产品性能结构及组 成试剂 瓶 A : 过氧化物酶标记物:过氧化物酶葡聚糖聚合物,Tris/HCl ,氯化 DAB 染 色液 钠,牛血清白蛋 白,5-溴-5-硝基- 1,3-二恶烷,4-氨基安替比林,聚乙二醇(PEG 3000),酪蛋白,吐温20, pH7.6。试剂瓶 B:DAB 底物缓冲液:咪唑,N,N'- 乙基 双(2-[2-羟基苯基]甘氨酸)(EDHPA), 乙基苯基聚乙二醇(Nonidet P-40),过氧化 氢,氯化苯二甲烃铵,pH 7.5。试剂瓶 C:DAB 显色剂:3,3 二氨基联苯胺四氯化 碳溶于 80%丙二醇中。 是指以煤油或柴油馏分为原料,经分子筛吸附分离或异丙醇-尿素脱蜡,得到含正 构烷 烃的石蜡;或者是煤/天然气液化过程中合成的液体石蜡。因常温下呈透明 液体石蜡 无色或浅黄 色液体,故称液体石蜡。室温下无嗅无味,加热后略有石油臭,密度 比重 0.86-0.905, 不溶于水、甘油、冷乙醇。用于苯、乙醚、氯仿、二硫化碳、 热乙醇 是氧气在液态状态时的形态。呈浅蓝色,沸点为- 183℃ ,冷却到-218.8℃成为雪 液氧 花状的 淡蓝色固体,液氧的密度(在沸点时)为 1. 14g/cm3 。液氧具有顺磁性。它 的主要物理性质 如下:通常气压(101.325 kPa)下密度 1141kg/m3 ,凝固点222.65 °C。 分子式为(C3H5NO)n ,是一种线状的有机高分子聚合物,同时也是一种高分子水 聚丙烯酰 处理絮 凝剂产品,专门可以吸附水中的悬浮颗粒,在颗粒之间起链接架桥作用, 胺 使细颗粒形成 比较大的絮团,并且加快了沉淀的速度。因其中良好的絮凝效果 PAM 作为水处理的絮 凝剂并且被广泛用于污水处理。 硫代硫酸 分子式为 Na2S3O3 ,无色或白色结晶性粉末,熔点 48℃ ,沸点 100℃ ,密度 钠 1.667g/cm3, 溶于水喝松节油,难溶于乙醇。刺激眼睛、呼吸道和皮肤。 原辅材料规范化贮存措施: 项目运营过程中医疗使用的原辅材料种类繁多, 包括药品、 输液管等医 疗器材贮存在仓库内、化验室化学试剂贮存在专门化学药品贮存室、污水站药 品贮存在污水站贮药间、备用发电机柴油贮存在柴油罐内, 规范化贮存措施如 下: 39 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 (1)药品、医疗器材仓库 1)药品、医疗器材仓库内整洁,门窗严密,地面平整。 仓库有下列设备和设施,并保持完好:温湿度仪、货架(柜),符合安全 要求的照明、通风、消防、监控设施;必要的防尘、防潮、防鼠、防虫等设施。 做好防尘、防潮、防鼠、防虫、防火、防盗、防霉变等“七防”工作。 “三不靠”原则:产品码放不靠顶棚,不靠墙,不靠地 2 合理分区原则: 库房要合理分区,分为待验区,合格区,不合格区。 2)根据医用耗材、药品的类别、性质、用途等属性实行分类存放。对有 特殊储存条件要求的,按要求储存。不同性质的药品不能混放。药品与非药品、 内服药与外用药、易串味药品与一般药品应严格分开存放,包装易混滑的药品 也应分开存放;特殊管理药品应专柜存放;危险品的储存应按国家有关规定存 放于安全的专用场所。 3)医用耗材按温湿度要求陈列或储存于相应的库(区):常温库温度为 10-30℃℃、阴凉库温度不高于 25℃、冷藏库(柜)温度为 210℃,相对湿度应 保持在 45%-75%之间。定期对仓库的使用环境进行巡查维护,记录库内温度 和湿度,根据温湿度情况,采取相应措施,保证产品质量。 4)药品堆应留有一定距离,药品与墙、屋顶(房梁)的间距不小于 30cm, 与库房散热器或供暖管道的间距不小于 30cm,与地面的间距不小于 10cm。 5)库存医用耗材应按批号及效期远近依序存放,不同批号物品不得混放。 储存药品每月进行一次有效期检查,对有效期在 12 月内的药品应记录库存和用 量,有效期在 6 个月内的药品应及时与各部门和临床医生联系,尽早使用。 6)根据医用耗材在库的质量状态实行色标管理:医用耗材库(区)、退 货库(区)为黄色:合格品库(区》、待发品库(区)为绿色;不合格品库 (区)为红色。三色标牌以底色为准,文字以白色或黑色表示。 8)仓库管理员每天上、下午定时对库房进行巡查,发现温湿度异常时, 及时采取措施进行调节,并做好记录。仓库管理员定期对在库(房)医用耗材 40 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 进行检查并做好养护记录。对过期、失效、变质、霉烂、虫、破损等不合格物 品,应立即封存登记。 (2)化验室化学试剂贮存 1)化学试剂、药品的贮存 化学药品贮存室应符合有关安全规定,有防火、防爆等安全措施,室内应 干燥、通风良好,温度一般不超过 28℃,照明应是防爆型。 化学药品贮存室应由专人保管,并有严格的账目和管理制度,使用时先申 请,经同意后填写使用登记情况表。 室内应备有消防器材。 化学药品应按类存放,特别是化学危险品按其特性单独存放。 2)化学试液的管理 装有试液的试剂瓶应放在药品柜内,放在架上的试剂和溶液要避光、避热。 试液瓶附近勿放置发热设备如电炉等。 试液瓶内液面上的内壁凝聚水珠的,使用前要振摇均匀。 每次取用试液后要随手盖好瓶塞,切不可长时间让瓶口敞开。 吸取试液的吸管应预先清洗干净并晾干。同时取用相同容器盛装的几种试 液防止瓶塞盖错造成交叉污染。 已经变质、污染或失效的试液应该随即处理,重新配制。 3)危险品安全保管 实验用化学危险药品必须储存在专用室或柜内,不得和普通试剂混存或随 意乱放。还要按各自的危险特性,分类存放。 化学危险药品室、柜,必须有专人管理。管理人员要有高度的责任感,熟 悉各种化学药品的危险特性,具有一定的防护知识。 化学危险品室要配备相应的消防设施,如灭火器等,专管人员要定期检查。 定期对化学危险品的包装、标签、状态进行认真检查,并核对库存量,务 使帐物一致。 41 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 对实验中有危险药品的遗弃废液、废渣要及时收集,妥善处理,不得在实 验室存留,更不得随意倒在下水道。 危险试剂的管理和使用方面如出现问题,除采取措施迅速排除外,必须及 时向领导如实报告,不得隐瞒。 (3)污水站贮药间 污水站次氯酸钠、聚丙烯酰胺、硫代硫酸钠贮存在污水站贮药间内。 1)储存环境应该干燥、通风、避光、防潮,宜在常温下保存;远离火种、 热源库温不宜超过 30℃。 2)储存场所要与酸、碱、氧化剂等分开存放,避免混放造成事故; 3)药剂桶要保持密封,避免挥发和泄漏。 4)药剂使用区域应该设立标志牌、警示标志等,提醒人们注意药剂危险; 药剂使用过程中应该配备好防护用品,如手套、口罩等;药剂使用过程中应该 做好通风措施,避免药剂气味对人体造成危害; 5)药剂使用过程中应该做好应急预案,一旦发生意外事故应该立即采取 相应措施进行处理。 (4)备用发电机柴油罐贮存 1)所有发电机储油罐应符合国家相关法律法规和标准的要求,并经过合 格检验和认证。 2)发电机储油罐必须定期进行检查和维护,以确保其工作正,常并且没 有任何安全隐惠。 3)储油罐的容量应根据实际需求进行合理确定,且要能够满足长时间供 电的需求。 4)储油罐必须安装在指定的区域内,并保持良好的通风条件,以防止油 气积聚和火灾、爆炸的发生。 5)储油罐的周围必须保持清洁,防止杂物和易燃物贴近或堆积。 6)储油罐应配备液位监测系统,以及泄漏报警装置,能够及时发现油位 异常和泄漏情况。 42 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 7)储油罐应定期清理,清除沉淀物和杂质,保证油品的质量和可靠性。 8)在维修和清理储油罐时,必须采取相应的安全措施,如使用防爆工具 和设备,并遵守相关的操作规程。 9)储油罐必须定期进行标志和标识,以便于识别、巡检和管理。 10)对发电机储油罐进行管理和使用的人员,必须经过专业培训,掌握相 关的安全知识和操作技能。 3.1.5 公用项目及能源消耗 1、给水 (1)水源 本项目用水由郸城县市政供水管网供给,可以满足本项目各类用水需求。 (2)给水 项目用水部门包括门诊病人用水、住院病房用水,医院职工用水、特殊科 室用水、食堂用水、中央空调制冷补水、绿化用水、车辆洗消用水。 医院内部不考虑设置洗衣房,后勤工作人员等未被污染的被服全部外协委 托第三方机构清洗处理,定期自取洁净被服。病区的医务人员和病患被服紫外 线消毒后再外协洗衣。 1)门诊病人用水 项目设计日门诊量按 2400 人次计,根据《传染病医院建筑设计规范》 (GB50849-2014),门(急)诊病人每人每次用水量为 25~50L,本评价按 40L 计算,则门诊用水量为 96m3/d, 排水量按用水量 80%计,则废水量为 76.8m3/d。 该部分废水排入化粪池臭氧预处理后与其他废水一同进入院区地下污水处理站 处理。 2)住院病房用水 住院病房用水主要是住院病人用水和陪护人员用水。 查阅河南省地方标准《工业与城镇生活用水定额》(DB41/T385-2020), 三级医院先进值日用水定额为 560L/床·d(该标准仅给出 560L/床·d 一个用水定 额,未具体细分门诊、住院等具体单元用水定额);查阅《建筑给排水设计标 43 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 准》(GB50015-2019 ),单独卫生间的住院部用水为 110-140L/床·d;查阅 《传染病医院建筑设计规范》(GB50849-2014),贵宾病房用水系数为 400600L/床·d,病房设独立浴室、卫生、盥洗室用水系数为 250~400L/床·d。 考虑到本项目医院为传染病医院,医院病房均设置独立浴室、卫生、盥洗 室,本次评价对住院病房用水系数取《传染病医院建筑设计规范》(GB508492014)中病房设独立浴室、卫生、盥洗室用水系数的最大值 400L/床·d 参与计 算,该系数已涵盖陪护人员用水不再单独核算。 项目医院共设 800 张床位,则住院病房用水量为 320m3/d, 排污系数以 0.8 计, 则废水产生量约为 256m3/d 。 住院病房废水排入化粪池臭氧预处理后与其 他废水一同进入院区地下污水处理站处理。 3)医院职工生活废水 包括病区医务人员生活用水、后勤管理人员用水及职工宿舍楼用水。 病区医务人员生活用水:项目医务人员 900 人, 根据《建筑给排水设计标 准》 (GB50015-2019) 和《传染病医院建筑设计规范》(GB 50849-2014) (150-300L/d·人), 医务人员用水量按 250L/班·人计,医院医务人员共 900 人 , 实 行 每 天 8h 三 班 制 ( 白 班 约 600 人 , 夜 班 约 300 人 ) 。 则 用 水 量 为 22.5m3/d, 排污系数以 0.8 计, 则废水产生量约为 18m3/d 。 医护人员废水排入 化粪池臭氧预处理后与其他废水一同进入院区地下污水处理站处理。 后勤管理人员用水:项目行政后勤和管理人员 300 人 ,根据《建筑给排水 设计标准》 (GB50015-2019) 和《传染病医院建筑设计规范》(GB 508492014)(30-50L/班·人),项目后勤管理人员每天 8h 单班制, 后勤管理人员 用水量按照 40L/d· 人计, 则后勤管理人员用水量为 12m3/d, 排污系数以 0.8 计, 则废水产生量约为 9.6 m3/d 。后勤管理人员生活污水排入化粪池预处理后, 与其他废水一同进入院区地下污水处理站处理。 职工宿舍楼用水:职工宿舍能容纳 400 人住宿。参考河南省地方标准《工 业与城镇生活用水定额》(DB41/T385-2020)带淋浴的宿舍日均用水量按通用 44 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 值 60L/人·d 计则用水量为 24m3/d,排污系数按 0.8 计则废水为 19.2m3/d,废水 经化粪池处理后进入院内地下污水处理站处理。 4)食堂废水 食堂建成后供后勤办公人员 300 人,医护人员 900 人和病床人员 800 人及 陪护人员就餐。非呼吸道传染病房可设陪护,按每人每床 1 个陪护 800 人参与 计算,则食堂就餐人员 2800 人用餐,8400 人次/天。 参考《传染病医院建筑设计规范》(GB 50849-2014)(食堂 25-50L/人次) 按 25L/人次计则总用水量为 210m3/d,排污系数按 0.8 计则总食堂废水 168m3/d。 项目设置 2 个食堂,后勤办公综合楼内设置 1 个食堂供后勤办公人员就餐 (就餐人员 300 人),门诊医技综合楼设置 1 个食堂供医护人员及病患就餐 (就餐人员 2500 人)。食堂提供病房送餐服务。 后勤办公综合楼内食堂废水(18m3/d)不具有传染性,经油水分离器隔油 处理后排入医院地下污水处理站处理。 门诊医技综合楼内的食堂废水(150m3/d)具有传染性,经油水分离器隔油 处理,再经过臭氧预消毒后排入医院地下污水处理站处理。 5)空调冷凝水 项目空调系统采用分体空调、多联机或风冷热泵,不采用水冷不涉及水冷 排水。 根据《传染病医院建筑设计规范》(GB 50849-2014),传染病医院空调的 冷凝水应分区集中收集,并应随各区污水、废水排放集中处理。 根据建筑面积估算冷负荷,病区构筑物冷负荷为 484.336kW,非病区构筑 物冷负荷为 109.208kW。每 1kW 冷负荷每 1h 约产生 0.4kg 左右冷凝水, 全年 按 120 天计,则病区空调冷凝水排放量为 4.65m3/d, 558m3/a,非病区空调冷凝 水排放量为 1.05 m3/d,126m3/a。 病区空调冷凝水随病区医疗废水一起经化粪池臭氧消毒后排入医院地下污 水处理站,非病区空调冷凝水直接排入医院总排口。 6)特殊科室用水 45 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 门诊和病房部分病人就诊期间需要进行化验,会产生特殊科室废水,主要 为手术室、病理科及检验科仪器设备、容器清洗用水。需化验的病人数按照项 目设计日门诊人次和住院病人的 50%计 1600 人次/日。每次化验用水量按 10L/ 人次为 16m3/d,排污系数按 0.8 计为 12.8m3/d。 目前医院化验室大部分采用仪器分析代替传统的化学分析检验方法,在检 测过程中使用的药品、试剂量均较小,特别是含重金属的试剂如含铬、含氰试 剂等已淘汰,因此,化验室产生的废水为不含重金属的医疗废水,医院大多数 检验项目或制作化学清洗剂时,经常会使用氢氧化钠、盐酸等,会产生酸碱废 水,利用玻璃容器储存至一定量后加入氢氧化钠或盐酸等进行中和处理,控制 pH 在 7-8 之间,经中和预处理、臭氧消毒后排入院区地下污水处理站。 7)车辆洗消用水: 根据《建筑给水排水设计标准》(GB50015)(2019 年版),车辆冲洗日 用水定额轿车为 40~60L/辆·次,公共汽车、载重汽车为 80~120L/辆·次,进 出车辆主要为主要救护车、物资运输、医疗清运车等共约 10 辆,本次评价按照 100L/辆·次进行核算,每天洗消 1 次,用水量为 1m3/d,排水量按用水量 90% 计为 0.9m3/d,排入地下无接触消毒池预处理后引至院区污水站处理。 8)电蒸汽发生器用水 本工程蒸汽主要为手术室及中心供应医疗消毒用汽。 选用两台蒸汽压力 1.0MPa 额定蒸发量为 0.6T/h 电蒸汽发生器。 每天运行 24h, 蒸汽发生器给水 由纯水装置提供, 纯水制备采用反渗透法, 设备的纯水得水率为 60%, 蒸汽 使用纯水量约 28.8m3 /d, 则纯水制备系统自来水用量约为 48m3 /d, 产生 19.2m3 /d 的浓水为清排水直接排入医院总排口。 消毒蒸汽用量约 28.8t/d, 排污系数取 0.8, 则蒸汽消毒废水排放量为 23.04m3 /d,降温后进入医院地下污水处理站进行处理。 9)绿化用水 46 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 根据河南省地方标准《工业与城镇生活用水定额》(DB41/T385-2020), 本项目绿化用水标准按 0.6m3/m2·a 计,本工程绿化面积 22942.5m2,全年绿化 天数约 200 天,则绿化用水量为 68.8275m3/d(13765.5m3/a)。绿化用水不外排。 整个医院总工程用水情况如下: 表 3-9 序 号 日损耗 日用水 年用水 量 量 量 (m3/d (m3/d) (m3/a) ) 日排 水量 (m3/d) 年排水量 (m3/a) 用水项目 用水标准 人数 门诊病人 40L/人 2400人 /d 96 35040 19.2 76.8 28032 住院病房用水 400L/床 d 800床 320 116800 64 256 93440 医务人员用水 250L/人 d 900人 22.5 8212.5 4.5 18 6570 按10L/人 1600人 次 次/日 16 5840 3.2 12.8 4672 / / / 4.65 558 1 365 0.1 0.9 328.5 48 17520 42.24(清排 15417.6(清 5.76 水19.2、废水 排水7008, 23.04) 8409.6废水) 187.5 68437.5 37.5 691 252215 134.26 化验室用水 中央空调 冷凝水 病区 项目总工程用水情况 / 次 / 每天洗 车辆洗消用水 100L/辆·次 1次, 10辆 蒸汽消毒用水 — — 门诊医技综合 7500人 25L/人次 楼食堂用水 次/d 小计 后勤行政用水 40L/人 d 300人 12 宿舍用水 60L/人 d 400人 24 后勤办公综合 900人 25L/人次 22.5 楼食堂用水 次/d 中央空调 / / / 冷凝水 非病 22942. 区 3 0.6m /(m 5m2( 绿化 68.8275 2.a) 绿化 200d/a) 小计 — — 127.3275 47 150 54750 561.39(清排 203768.1(清 水19.2) 排水7008) 9.6 3504 19.2 7008 4380 8760 2.4 4.8 8212.5 4.5 18 6570 / / 1.05(清排 水) 126(清排 水) 0 0 13765.5 68.8275 35118 80.5275 47.85(清排 17208(清排 水 1.05) 水 126) 郸城县人民医院西南院区新建项目环境影响报告书 合计 — — 818.3275 第三章工程分析 220976.1(清 214.787 609.24(清排 排水7134、 287333 水20.25、污 5 废水 废水588.99) 213842.1) 根据上表核算,整体工程用水量为 818.3275m3/d,287333m3/a。 项目排水量为 609.24m3/d(220976.1m3/a),其中进入污水站处理的废水量 为 588.99m3/d(213842.1m3/a),20.25m3/d(7134m3/a)为纯水制备浓水和非病 区空调冷凝水清排水直接经总排污口排放。 其 中纯水 制备浓水 19.2m3/d (7008m3/a), 非病 区 空调 冷凝水 1.05m3/d (126m3/a)。 2、排水 (1)废水产生量 根据前述表格核算,工程排水量合计 609.24m3/d,220976.1m3/a(包含清排 水 7134m3/a、废水 213842.1m3/a)。 (2)排水去向 项目总体排水系统采用雨、 污分流。 污水分质分类进行预处理。 ①污水: 非病区废水:后勤办公楼普通食堂废水隔油处理,与普通化粪池处理过的 其他一般生活污水(后勤办公人员废水、宿舍楼、空调冷凝水)一起排入院区 地下污水处理站,达标处理后经市政污水管网进入郸城县第三污水处理厂进一 步处理。 病区废水:病区食堂废水经油水分离器处理、病区化验室废水经酸碱中和 处理后经过臭氧预消毒,然后与化粪池+臭氧预消毒处理过的病区其他医疗废 水(门诊废水、 住院病房废水、 医务人员废水、空调冷凝水、蒸汽消毒废水) 一起排入院内污水站处理,车辆洗消废水排入地下无接触消毒池预处理后引至 院区污水站处理。 蒸汽纯水制备浓水和非病区空调冷凝水作为清排水直接排入医院总排口。 48 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 医院不使用氰化物、 含铬等试剂, 不产生含氰、 含铬废水, 且影印中心 无洗印废水产生。 ②雨水: 初期雨水经院内 DN400~DN800 雨水管收集后, 排入市政雨水管 网。 疫情时,可向雨水排口投药消毒, 保证污染不扩散。 全医院水平衡详见图 3-1。 图 3-2 本项目总工程用水量平衡图(m3/d) 3、供配电系统 根据工艺及用电要求,本项目用电负荷主要分为仪器设备用电、照明用电 等,由郸城县电业局供给。 49 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 本项目在地上一层紧临配电房设置柴油发电机房 1 处,配备两台 1000kVA 柴油发电机组,地上一层柴油发电机房内配套设置 1 个 1t 柴油罐, 停电时作为备用电源;变电所自用电采用 UPS 电源装置作为后备电源;安防 监控中心、 信息网络机房、音控室等场所的重要设备设置 EPS 电源装置作为 后备电源。 4、制冷供暖 根据项目设计,本医院不采用锅炉供热,不设置锅炉。 项目医院病房楼制冷供暖采用分体空调;宿舍楼室内采用一拖多多联机, 室外采用风冷换热形式;门诊楼、呼吸道楼、发热门诊、后勤办公综合楼各设 1 套中央空调风冷热泵机组设于楼顶,采用风冷省去了水冷冷水机组的冷却水 系统。 医院热水供应采用电热水器。医院消毒蒸汽采用电蒸汽发生器制备。医院 内部不考虑设置洗衣房,后勤工作人员等未被污染的被服全部外协委托第三方 机构清洗处理,定期自取洁净被服。病区的医务人员和病患被服紫外线消毒后 再外协洗衣。 5、通风系统 院区设计采用全面通风系统, 即机械送风, 机械排风, 清洁区送风量大 于排风量,半污染区/污染区送风量小于排风量, 使室内空气形成有组织的气流 流动。 气流流向为清洁区—半污染区—污染区。 送风机、 排风机采用变频控制, 平时降频运行, 降低新排风量, 降低运 行能耗; 疫情时, 工频运行, 按规范要求的新排风量运行, 满足卫生标准。 非呼吸道传染病的门诊、医技用房及病房最小换气次数(新风量),应为 3 次/h。污染区房间应保持负压,每房间排风量应大于送风量 150m3/h。 呼吸道传染病的门诊、医技用房及病房、发热门诊最小换气次数(新风量), 应为 6 次/h。建筑气流组织应形成从清洁区至半污染区至污染区有序的压力梯 度。房间气流组织应防止送、排风短路,送风口位置应使清洁空气首先流过房 50 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 间中医务人员可能的工作区域,然后流过传染源进入排风口。 送风口应设置在 房间上部。病房、诊室等污染区的排风口应设置在房间下部,房间排风口底部 距地面不应小于 100mm。清洁区每个房间送风量应大于排风量 150 m 3 /h。污 染区每个房间排风量应大于送风量 150m 3 /h。同一个通风系统,房间到总送、 排风系统主干管之间的支风道上应设置电动密闭阀,并可单独关断,进行房间 消毒。 负压隔离病房宜采用全新风直流式空调系统。最小换气次数应为 12 次/h。 负压隔离病房的送风应经过粗效、中效、亚高效过滤器三级处理。排风应经过 高效过滤器过滤处理后排放。负压隔离病房排风的高效空气过滤器应安装在房 间排风口处。每间负压隔离病房的送、排风管上应设置密闭阀。负压隔离病房 的通风系统在过滤器终阻力时的送排风量,应能保证各区压力梯度要求。有条 件时,可在送、排风系统上设置定风量装置。负压隔离病房送排风系统的过滤 器宜设压差检测、报警装置。负压隔离病房应设置压差传感器。负压隔离病房 与其相邻、相通的缓冲间、走廊压差,应保持不小于 5Pa 的负压差。 公共卫生间通风采用吊顶换气扇,排至管道井后接至屋面排风机排走,卫 生间换气次数为 10~15 次/时。吊顶换气扇接入管井处设止回装置,排风管接入 管井处设防火阀。其余换药室、处置室、污物室等设机械排风系统,排风量按 10~15 次/时换气次数确定。 地下设备用房设置机械送排风系统,排风量为 5~8 次/h,补风量为排风量 的 80%。变配电室设置机械送排风系统,排风量按变压器无功损耗确定,补风 量为排风量 80%。地下车库设置机械排风系统、自然进风,地下车库机械排风 系统兼作机械排烟系统,排风换气次数按 6 次/h。冷冻站等设事故通风系统, 换气次数为 12 次/h,设置相应的检测报警及控制系统,事故通风的手动控制装 置设置在室内外便于操作的地点。其余换药室、处置室、污物室等设机械排风 系统,排风量按 10~15 次/h 换气次数确定。配电室、信息机房、医技间等设气 体灭火,凡气体灭火房间均设防护区通风,其排风口设在防护区下部和上部 51 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 (下排 2/3),气体灭火结束后防护区开启通风机及其阀门,将室内有害气体排 至室外。 本工程全院区考虑平疫结合。根据卫健委、发改委发布的医院“平疫结合” 可转换病区建筑技术导则(试行),门诊医技区,平时最小新风量为 3 次/h。 疫情时最小新风量为 6 次/h。住院区,平时最小新风量为 2 次/h。疫情时,负压 病房最小新风量为 6 次/h 或 60 升/s 床计算,取大值;负压隔离病房最小新风量 为 12 次/h 或 160 升/s 床计算,取大值。 6、氧气站 项目病房、门诊楼需设置氧气、负压吸引等医用气体工程,其中负压病房 每床三气分别设置两个端口。氧气由室外的气源引入,负压吸引由地下室中心 吸引机房引入。 (1)中心供氧系统 中心供氧系统氧气气源集中设置在氧气站,氧气通过减压装置和管道输送 到手术室、抢救室、治疗室和各个病房的终端处,供医疗使用。 中心供氧系统由氧气站、恒压监视装置、安全报警装置、管道和阀门及终 端送氧插头 4 个部分组成。氧气站设置 3 个 5m3 的液氧罐存储氧气。为了监测 各病区氧气使用压力情况,在每个病区单元的护士站安装一个压力监测装置来 监测各病区管道的压力,保证每个病区氧气压力大于 0.2MPa,战时病区氧气压 力大于 0.4MPa,以实现连续稳定地供氧。 (2)负压吸引系统 吸引站拟考虑设置在本项目地下一层附近,吸引系统的负压源是吸引站的 真空泵机组通过真空泵机组的抽吸,使吸引系统管路达到所需负压值,在手术 室、抢救室和各个病房终端处产生吸力供医疗使用。 7、消毒 医院地面采用 84 消毒液冲洗。 医院消毒蒸汽采用电蒸汽发生器制备。 52 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 医院地下污水处理站废水消毒方式采用次氯酸钠消毒,恶臭废气采用紫外 线消毒,污泥消毒投加生石灰。 另外根据 2020 年 2 月 1 日生态环境部发布的《新型冠状病毒污染的医疗污 水应急处理技术方案(试行)》中“三、采用化学药剂的消毒处理应急方案 (一)常用药剂医院污水消毒常采用含氯消毒剂(如次氯酸钠、漂白粉、漂白 精、液氯等)消毒、过氧化物类消毒剂消毒(如过氧乙酸等)、臭氧消毒等措 施”,本项目感染病区污水进行地下污水处理站前预处理采用臭氧消毒,符合 相关技术要求。 医院手术室、ICU 等有洁净要求的特殊场所采用独立设置的洁净空调系统, 控制手术室的菌浓度,使手术室达到一定的生物清洁标准。 医院内部不考虑设置洗衣房,后勤工作人员等未被污染的被服全部外协委 托第三方机构清洗处理,定期自取洁净被服。病区的医务人员和病患被服紫外 线消毒后再外协洗衣。 8、消防 室外消防用水来自城市管网供水,室内消防给水系统由室内消防管网、室 内消火栓组成。室内消防给水系统与生活给水系统分开独立设置。室内消防给 水系统为独立系统,不分区。消火栓的布置按任何一点均有两股水柱到达设计, 每根消防立管每层设置室内消火栓 1 个。另外,根据需要在必要位置设置足够 数量的手提式磷酸铵盐干粉灭火器。 同时在走道、公共活动用房、病房及办公室内除放射科等不可用水灭火的 场所外,均设置闭式自动喷水灭火系统保护。 9、燃气 医院食堂由周边的市政天然气管道供气。 3.2工艺流程及主要产污环节 3.2.1 施工期工艺流程及产污分析 工程施工顺序按照先地下后地上的原则,将工程划分为场平、基础及地下 室工程、主体结构工程、外墙内饰装修和工程验收五个阶段。具体流程如下: 53 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 图 3-3 施工期总体工艺流程示意图 (1)土方工程 土方工程包括土(或石)的挖掘、填筑和运输等主要施工过程,以及排水、 降水、土壁支撑等准备和辅助工程。本工程土方工程包括场地平整、基坑开挖、 地坪填土、路基填筑和基坑回填等。 基坑开挖是典型的土方工程,具体流程如下: 测量放线→土方开挖→边坡支护→验坑→浇捣垫层→绑扎承台钢筋、底板 及基础梁钢筋、预埋柱、混凝土墙钢筋→安装地下底板侧模→浇捣地下底板混 凝土→绑扎混凝土墙、柱钢筋→预埋混凝土墙止水带→安装混凝土墙、柱模板 →浇筑混凝土墙、柱混凝土→安装地下顶板模板→绑扎地下顶板钢筋→浇捣地 下顶板混凝土→拆模板养护→地下验收→进入主体施工。 基坑开挖常见设备包括:推土机、挖土机、铲运机以及运输车辆等。 (2)桩基工程 桩基基础是由若干个沉土中的单桩组成的一种深基础,流程如下: 工艺流程:桩的制作(外协)→运输至施工现场堆放→根据设计图纸桩基 平面确定桩基轴线→设置打桩水准点→垫木、桩帽和送桩准备→设置打桩标尺 54 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 →静力压桩→拔桩→人工凿去桩头→承台浇灌主要施工设备:液压压桩机、吊 装设备、平台车(桩运输设备)等。 (3)钢筋混凝土结构工程 钢筋混凝土结构工程由模板工程、钢筋工程和混凝土工程三部分组成。在 施工中三者密切配合,进行流水施工,其施工工艺如下图所示: 图 3-4 钢筋混凝土结构工程 工艺说明: ①模板工程 为保证工程结构和构件各部分形状、尺寸和相互间位置的准确性,考虑构 筑物不同位置质量的要求,根据模板的材质,选用木模板、钢模板、塑料模板 等。模板一般委托预制构件厂外协加工生产制作,运至现场组装后即可使用。 ②钢筋工程 具体流程为:钢筋进场→调直、冷拉、冷拨、焊接(闪光对焊、电弧焊、 点焊等)、除锈(电动除锈机、钢丝刷、砂盘等除锈)→下料→切断→弯曲→ 熟悉施工图纸,钢筋绑扎和安装→钢筋网、骨架安装。 主要设备:闪光对焊机、电弧焊机、电焊机、冷拉机、冷拨机、电动除锈 机、钢筋切断机、手动切断器、成型工作台、卡盘、扳手、钢筋钩。 ③混凝土工程 本工程现场不设混凝土搅拌站,全部外购商品混凝土。每天所需的混凝土 向商家订货后,由各商家将工地所需的混凝土通过混凝土搅拌运输车运至现场。 混凝土运至现场后,卸入移动式浇注车(低层)、固定式浇注平台(高层)等, 将混凝土浇入模框,由人工钢钎、振动棒等捣实混凝土,由人工外加添加剂、 喷水等防护措施提高混凝土的强度,待混凝土凝固后,拆除模板。 55 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 主要设备包括:混凝土搅拌运输车、移动式浇注车、垂直升降机、移动浇 注机、固定浇注平台等。 (4)结构安装工程 结构安装工程是用各种起重机械将预制的结构构件安装到设计位置的施工 过程。现场施工一般使用吊装机械进行装配。 结构安装工程中的设备一般包括: ①索具设备:钢丝绳、滑轮组、卷扬机、吊具等; ②起重设备:塔式起重机、汽车式起重机。 (5)砌体工程 砌体工程主要以手工操作为主,施工过程包括砂浆制备、材料运输、搭设 脚手架和砌体砌筑等。 (6)防水工程 防水工程工程部位主要为屋面防水、地下防水、外墙面防水和卫生间楼地 面防水等。常用防水材料包括防水卷材、防水涂料、建筑密封材料和防水剂等。 (7)装饰工程 装饰工程包括抹灰、饰面安装施工、涂料工程。 抹灰包括装饰抹灰、一般抹灰等。装饰抹灰的方式包括喷涂、辊涂、刷涂 等工艺。饰面安装施工包括天然石饰面板材、金属饰面板、木质饰面板、玻璃 饰面板等。 (8)项目施工期产污分析见下表: 表 3-10 项目施工期产污分析表 污染类型 废水 产污环节说明 车辆冲洗废水、混凝土养护废水、生活污水 主要污染因子 SS、石油类等 噪声 挖土机、推土机、铲运机等施工机械及施工车 辆噪声 LAeq 废气 施工扬尘、车辆及机械运行尾气、装修废气 扬尘、SO2、NOx等 固废 生活垃圾、建筑垃圾、弃土 、生活垃圾、建筑垃 圾、弃方等 3.2.2 运营期工艺流程及产污分析 56 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 对于项目所有涉及到的放射性部分(DR、CT)均由院方委托相关有资质 单位进行专项评价分析,不在本次评价范围内,因此,本次评价仅就其相关非 放射性部分污染物进行分析。 项目口腔科主要采用环氧树脂代替汞合金,不使用银汞合金,无含汞废水。 项目影像科照片采用数码打印,无洗印废水产生。院区洗衣外协,不设洗 衣房,不产生洗衣废水。 项目门急诊医技住院综合楼、发热门诊的化验中心化验功能包括血细胞分 析、常规生化检验、尿液常规检验、大便常规检验、常规免疫微生物检验、血 库等常规化验,无重金属检验,其化验功能同一般医院类似。目前医院化验室 大部分采用仪器分析代替传统的化学分析检验方法,在检测过程中使用的药品、 试剂量均较小,特别是含重金属的试剂如含铬、含氰试剂等已淘汰,因此,化 验室产生的废水为不含重金属的医疗废水,医院大多数检验项目或制作化学清 洗剂时,经常会使用氢氧化钠、盐酸等,会产生酸碱废水,利用玻璃容器储存 至一定量后加入氢氧化钠或盐酸等进行中和处理后,与其他病区医疗废水经专 用化粪池+臭氧预消毒后排入进入院内污水站处理。 运营期工艺流程及产污环节见图 3-5 和表 3-11。 57 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 图 3-5 医院工艺流程及产污环节示意图 58 郸城县人民医院西南院区新建项目环境影响报告书 项目 第三章工程分析 表 3-11 项目产污环节一览表 污染源 污染物 环保措施 病区含菌废气采用紫外线杀毒后经 专用排风烟道引至楼顶排放;手术 含病原体的气 含菌废气 溶胶 室、负压病房采用全新风直流式空 调系统,送风应经过初效、中效、 高效过滤器三级处理,排风经过高 效过滤器过滤处理后经过专用排风 医疗区、病房 烟道引至楼顶排放 区 经安全柜配套高效空气过滤器处理 后去除致病细菌、生物气溶胶及其 挥发性有机废 他污染物有害气体后,再引至楼顶 检验废气 气 排放,同时医院做好检验室内的消 毒卫生工作,确保检验废气处理后 不会对周围环境造成明显影响 后勤办公综合楼食堂油 烟 经1套高效静电式油烟净化器处理 食堂油烟 后经烟道引至后勤办公综合楼楼顶 排放 废气 门诊医技综合楼食堂油 烟 经1套高效静电式油烟净化器处理 食堂油烟 后经烟道引至门诊医技综合楼楼顶 排放 停车场汽车尾气 CO、NOX、 两侧加强绿化,地下车库设置抽排 THC 风系统,及时疏导进出泊车位车辆 经1套负压抽吸+生物除臭+紫外线 配套服务 地下污水处理站恶臭 臭气浓度、 消毒后经管道引至附近病房楼楼顶 H2S、NH3 排放(20m高,周边最近病房楼设 计高度18.65m)。 臭气浓度、 经管道引至污水站恶臭措施处理排 危废间废气 H2S、NH3 生活垃圾收集站恶臭 备用柴油发电机废气 废水 医疗服务 H2S、NH3 燃烧废气 仅收集,不处理不压缩。垃圾袋装 化,减少垃圾暴露时间,及时清 运,日产日清,使用除臭剂 由自带的净化装置处理后经管道引 至附近构筑物楼顶排放。 检查、化验 SS、COD、 病区食堂废水经油水分离器处理、 门诊治疗 BOD5、NH3- 病区化验室废水经酸碱中和处理后 病房楼 N、粪大肠菌 经过臭氧预消毒,然后与化粪池+ 群、肠道致病 臭氧预消毒处理过的病区其他医疗 空调冷凝水 配套服务 臭气浓度、 放 菌、肠道病 废水(门诊废水、 住院病房废 蒸汽消毒 毒、结核杆菌 水、 医务人员废水、空调冷凝 办公生活 生活污水 水、蒸汽消毒废水)、隔油预处理 59 郸城县人民医院西南院区新建项目环境影响报告书 食堂 第三章工程分析 含油废水 过的非病区普通食堂废水、普通化 粪池处理过的非病区其他生活污水 (后勤办公人员废水、宿舍楼、空 调冷凝水)一起排入医院综合污水 车辆洗消 车辆洗消废水 处理站进一步处理达标后,汇入郸 城县第三污水处理厂,尾水排入洺 河。消毒蒸汽纯水制备浓水和非病 区空调冷凝水作为清排水直接排入 医院总排口。 门诊、病房楼 经袋装收集后,暂存于医疗废物暂 病人产生的生 存间50m2内,并按照医疗废物进行 活垃圾(属于 暂存管理和处置,定期交由有资质 门诊科室及 医疗服务 医疗废物) 病房楼 医疗废物 单位进行清运处置 医疗废物暂存间暂存后, 委托有资质单位处置 医务后勤人员 生活垃圾分类收集后,日产日清, 医务后勤人员办公及宿 办公及宿舍产 每天由环卫部门负责清运至市政垃 舍 固废 生的普通生活 圾中转站,最终运至郸城县生活垃 垃圾 生活 圾焚烧厂发电厂焚烧 采用专用餐厨垃圾收集桶收集,集 食堂 餐厨垃圾 中收集后交由有资质的单位进行运 输处置 地下污水处理站 配套服务 污泥及栅渣 灯管 备) 纯水制备 空调风冷热泵机组、污 配套服务 理 废紫外线含汞 更换后暂存于危废暂存间25m2内, 紫外线消毒 废反渗透膜(纯水制 噪声 消毒压滤暂存后交由有资质单位处 水站水泵及污水站风 机、食堂风机、液氧站 空压机 定期交由有资质单位处置 更换后随生活垃圾一同交环卫部门 清运处理 空调风冷热泵机组设于楼顶、基础 运行噪声 减振、隔声罩隔声。水泵及风机设 置地下、减振、构筑物隔声、消声 措施等 3.3污染物产生及排放情况分析 3.3.1 施工期污染源及其防治措施 3.3.3.1 施工期主要污染工序 本项目在建设阶段由于基础工程、主体工程、装修工程的施工,不可避免 地将对周围环境产生影响。施工期主要污染因子有:施工人员生活污水、生产 废水(车辆冲洗废水、混凝土养护废水)、施工扬尘、施工废气(装修废气、 60 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 机械设备与运输车辆尾气)、施工噪声、固体废物(土石方、生活垃圾、建筑 弃渣)以及水土流失及生态破坏等。 (1)大气环境 项目施工期环境空气污染,主要来自施工期间产生的粉尘(地表开挖扰动 粉尘、设备运行引起粉尘、原辅材料堆场粉尘)、废气(装修废气、机械设备 与运输车辆废气),主要污染物为 TSP、THC、CO、NOx。 ①施工地表扰动扬尘 施工活动,将涉及到地表开挖及回填活动,受扰动地表可能产生粉尘。 ②设备运行引起粉尘 设备引起粉尘主要是由于车辆行驶造成,产生量较大,具有持续性特点。 ③材料运输、转运及堆放粉尘 材料运输、转运及堆放过程,遇大风天气易产生扬尘。 ④机械设备及运输设备废气 施工设备及运输车辆运行过程,燃油汽油或柴油产生少量废气。 ⑤装修废气 项目装修产生的废气来源于施工人员对墙壁的粉刷,修补,装修废气主要 为油漆、涂料等挥发造成的有机废气,主要有甲醛、苯等。 (2)水环境 施工期的废水主要来源于施工人员的生活废水及施工废水。 ①施工废水 项目建设施工期废水主要为车辆冲洗废水和混凝土养护废水。施工废水污 染物以 SS 为主。 ②生活污水施工人员生活污水主要污染物为 COD、NH3-N、SS、BOD5。 (3)声环境 61 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 把施工工程分为两个个阶段:主体工程和装修工程。这两个阶段所占施工 时间较长,采用的施工设备较多,噪声污染比较严重,不同阶段又各具其独立 的噪声特性。 施工阶段的噪声主要来自各种施工机械设备的噪声,其噪声强度与施工设 备的种类和施工管理有关。建筑材料运输过程中产生交通噪声,同时还包括突 发性、冲击性、不连续性的敲打撞击噪声。还包括各类设备施工噪声,具有阶 段性、临时性和不固定性的特点,将对其附近声环境产生一定的影响。 (4)固体废物 本项目施工期固体废物主要来自于施工期间土石方、施工人员的生活垃圾、 建筑施工的废料和包装材料等。 项目施工期间土石方用于场区回填,剩余弃土运至当地政府指定地点,建 筑施工废料(铁质弃料、木材弃料等)分类收集,可利用部分回收利用,不能 利用部分运至指定建筑垃圾填埋场,生活垃圾设置垃圾桶进行收集,由环卫部 门统一清运。 (5)水土流失及生态破坏 项目施工过程涉及地表开挖及回填,将破坏原有地表及地表植被,雨水冲 刷活动将带来水土流失加剧现象。 3.3.3.2 施工期污染源及其防治措施 (2)废气 1)装修废气 装饰工程用油漆、涂料等挥发造成的有机废气,主要有甲醛、苯等,属无 组织排放。为了防止和减少油漆等装饰材料中含有的有害化学物质的挥发而产 生废气污染,建议业主应选用符合国家规定质量要求的环保型油漆、涂料、胶 粘剂及装饰材料,以尽量减轻施工过程中及投入营业后产生的废气对环境的影 响,使室内装修后空气质量达到有关规定的要求。应该选取符合 GB18582-2020 《建筑用墙面涂料中有害物质限量》等的装修材料。 62 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 2)施工活动及材料运输粉尘 施工产生的扬尘主要集中在土建施工阶段,按起尘的原因可分为风力起尘 和动力起尘,其中风力起尘主要是由于露天堆放的建材(如黄沙、水泥等)及裸 露的施工区表层浮尘由于天气干燥及大风,产生风力扬尘;而动力起尘,主要 是在建材的装卸、搅拌过程中,由于外力而产生的尘粒再悬浮而造成,其中施 工及装卸车辆造成的扬尘最为严重。据相关调查统计资料,车辆行驶产生的扬 尘占总扬尘的 60%以上。车辆行驶产生的扬尘,在完全干燥情况下,可按下列 经验公式计算: 式中:Q——汽车行驶的扬尘,kg/km·辆; V——汽车速度,km/hr; W——汽车载重量,吨; P——道路表面粉尘量,kg/m2。 施工期扬尘的另一个主要原因是露天堆场和裸露场地的风力扬尘。由于施 工的需要,一些建材需露天堆放;一些施工点表层土壤需人工开挖、堆放,在 气候干燥又有风的情况下,会产生扬尘,其扬尘量可按堆场起尘的经验公式计 算: 其中:Q——起尘量,kg/吨·年; V50——距地面 50m 处风速,m/s; V0——起尘风速,m/s; W——尘粒的含水率,%。 V0 与粒径和含水率有关,因此,减少露天堆放和保证一定的含水率及减少 裸露地面是减少风力起尘的有效手段。尘粒在空气中的传播扩散情况与风速等 气象条件有关也与尘粒本身的沉降速度有关。以沙尘土为例,不同粒径的尘粒 的沉降速度见下表。 63 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 表 3-12 不同粒径尘粒的沉降速度 粒径(m) 10 20 30 40 50 60 70 沉降速度(m/s) 0.003 0.012 0.027 0.048 0.075 0.108 0.147 粒径(m) 80 90 100 150 200 250 350 沉降速度(m/s) 0.158 0.170 0.182 0.239 0.804 1.005 1.829 粒 径 (m) 450 550 650 750 850 950 1050 沉降速度(m/s) 2.211 2.614 3.016 3.418 3.820 4.222 4.624 由表可知,尘粒的沉降速度随粒径的增大而迅速增大。当粒径为 250 时,沉降速度为 1.005m/s,因此可以认为当尘粒大于 250 m m 时,主要影响范 围在扬尘点下风向近距离范围内,而真正对外环境产生影响的是一些微小尘粒 根据现场的气候情不同,其影响范围也有所不同。施工期间,施工扬尘势必会 对该区域的环境产生一定的影响。因此,本工程施工期应特别注意施工扬尘的 防治问题,须制定必要的防治措施,以减少施工扬尘对周围环境的影响。 由于本项目开挖的土方含水率较高,只要及时运走,在装卸过程中产生的 扬尘量极小。土方堆场只要做好防风措施,扬尘产生量也较小。 为进一步减小施工扬尘对环境的影响,评价要求在施工过程中,应严格按 照《郸城县污染防治攻坚战领导小组办公室关于印发郸城县 2022 年大气、水、 土壤污染防治攻坚战及农业农村污染治理攻坚战实施方案的通知》(郸环攻坚 办〔2022〕7 号)中施工扬尘的相关要求进行,其具体措施如下: 管理措施:建设单位对建筑工程扬尘污染防治管理工作负首要责任,应当 督促施工单位做好扬尘污染防治管理并加强检查;将扬尘防治目标及施工单位 的扬尘防治责任明确写入承发包合同,并督促施工单位严格落实扬尘污染防治 各项措施,施工工地现场设置降尘员岗位,建立降尘员岗位制度。降尘员佩戴 统一标识,实行一岗双责,对工地扬尘治理工作负直接管理责任。 工程措施: 64 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 ①施工围挡:施工现场沿四周连续设置封闭围墙(围挡),围墙(围挡) 必须安全可靠、整洁美观。一般路段高度不低于 2 米,主干道高度不低于 2.5 米等。 ②冲洗设施:施工现场进出口设置冲洗平台、沉淀池、排水沟等车辆冲洗 设施,达到水资源重复循环利用。 ③场地硬化:施工现场应建立洒水清扫保洁制度,设专人负责卫生保洁, 并做好保洁记录。每天对场区道路进行洒水清扫不少于 2 次,当遇到重污染天 气,要相应增加洒水频次,或施工现场配备洒水车辆。 ④覆盖绿化:施工现场建材应码放整齐,废弃建材建渣应及时清运,不能 及时清运的必须进行覆盖,施工现场非作业面裸土必须进行覆盖,超过三个月 以上不使用的堆土应进行绿化。 ⑤渣土运输:施工现场要使用专用渣土运输车辆,防止物料遗撒造成扬尘 污染。车辆驶离工地前,应落实专人进行冲洗管理,将轮胎和车身冲刷干净, 确保出场车辆符合要求,不污染城市道路。同时严禁超载、超速,按交通管理 部门指定的路线及时间运输。 施工期严格落实“八个百分百”,即施工现场 100%标准化围挡、工地砂土 不用时 100%覆盖、工地路面 100%硬化、拆除工程 100%洒水压尘、出工地车 辆 100%冲净车轮车身、施工现场长期裸土 100%覆盖或绿化、施工现场及污染 指数 100%监控、建筑垃圾清运车辆 100%自动化密闭运输。在项目施工期,对 扬尘严格采取上述防治措施后,其浓度可降至 1.0mg/m3,产生的扬尘可得到有 效控制。 3)机械设备运行废气及运输车辆废气 施工期间,使用机动车运送原材料、设备和建筑机械设备的运转,均会排 放一定量的 CO、NO2 以及未完全燃烧的 HC 等,其特点是排放量小,且属间 断性无组织排放,由于其这一特点,加之施工场地较开阔,扩散条件良好,因 此对其不加处理就可达到相应的排放标准。对此,环评要求在施工期内多加注 65 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 意施工设备的维护,使其能够正常的运行,从而可以避免施工机械因故障而使 产生的废气超标的现象发生。 (2)废水 1)生活污水 施工高峰期施工人员及施工管理人员人数可达 150 人左右,工人生活用量 按 0.05m3/人·天计算,生活用水约为 7.5m3/d。生活污水中主要含 COD、BOD5、 NH3-N、SS 等,按照 80%产污系数计算,污水量为 6m3/d。临时项目部及施工 人员生活区均设置隔油池 10m3、化粪池 10m3 处理食堂废水、生活污水,污水 经处理后通过临时管道排入周边市政污水管网。 2)施工废水 施工废水主要为车辆冲洗水及混凝土养护废水等。由于施工过程中未知水 量较多,根据类比分析,本项目施工废水产生量为 15m3/d,施工废水主要污染 因子为 SS,SS 浓度可高达 1000mg/L。施工生产废水经沉淀池 20m3 处理后可作 为生产用水用于运输车辆冲洗及场地洒水降尘,不外排。施工期结束后施工期 间产生的废水影响随之消除。 (3)施工噪声 施工期的机械有电钻、电锯等,设备主要有混凝土振捣器、打桩机、挖掘 机及运输车辆等。这些噪声源强见下表。 表 3-13 施工期主要噪声源及其声级值单位:dB(A) 施工阶段 土石方 声源 数量(个) 测量距离(m) 声源强度 液压挖掘机 2 1 82-90 电动挖掘机 2 1 80-86 轮式装载机 2 1 90-95 推土机 2 1 83-88 重型运输车辆 4 1 82-90 混凝土振捣器 2 1 80-88 打桩机 2 1 70-75 基建 66 郸城县人民医院西南院区新建项目环境影响报告书 装修安装 第三章工程分析 混凝土输送泵 2 1 88-95 钢筋折弯机 2 1 90-95 钢筋切割机 2 1 90-95 商砼车 4 1 85-90 电钻 2 1 85-90 电锯 2 1 85-90 手工钻 2 1 80-85 说明:本项目不设搅拌站,采用外购商品混凝土方式。 按声级相加的通用式 计算,若假设所有施工机械同时使用, 则合成声源源强为 101.5dB。距离衰减以点声源噪声衰减模式预测该项目 施工边界外 1 米处噪声:⊿L=20lg(r1/r2) 式中:⊿L——在距离点声源 r1、r2 处的衰减值; r1、r2——分别为距离点声源的距离。 按噪声合成声源源强(声源 1 米处)声级 101.5dB(A)计算,围墙隔声按 5dB(A)计,则现场施工随距离衰减后的值见下表。 表 3-14 施工期距声源不同距离处的噪声值单位:dB(A) 距离(m) 1 20 30 110 150 200 预测值 96.5 70.0 66.8 55.1 52.6 50.3 根据《建筑施工场界环境噪声排放标准》中有关规定,昼间 20m 处可达标, 夜间 110m 处可达标(项目夜间禁止施工)。 根据现场踏勘,项目厂界周边 110m 范围内无环境敏感点。项目昼间施工 期满足《建筑施工场界环境噪声排放标准》(GB12523-2011)标准要求。 为最大限度的减少施工期噪声对周围环境的影响,评价建议应采取以下环 保措施。 1)选用低噪声设备和工艺,加强检查、维护和保养机械设备,保持润滑, 紧固各部件,减少运行震动噪声。整体设备应安放稳固,并于地面保持良好接 触,有条件的应使用减振机座,降低噪声。 67 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 2)合理布局施工现场,设备运行点应尽量远离已有在用的建筑物,避免在 同一地点安排多台动力机械设备,以避免局部声级过高。 3)合理安排施工时间,严禁夜间施工。施工单位要严格按照《中华人民共 和国环境噪声污染防治办法》中规定的施工时间进行施工,在夜间(22:00~6: 00)、午间(12:00~14:00)禁止从事高噪声(如挖掘、打桩、搅拌)的作 业,中、高考期间严禁施工。因施工工艺需要等原因确需连续施工的,必须提 前 7 日向周围的 单位和居民公告。公告内容应当包括:本次连续施工起止 时间、施工内容、工地负责人及其联系方式、投诉渠道。 4)合理划定运输路线,适当限制大型载重车的车速,尤其进入居民区等敏 感区域时应限速禁鸣;定期对运输车辆维修、养护。 5)加强施工队伍的管理,禁止高声喧哗,避免不必要的噪声发生。 施工期加强施工管理后,施工噪声对周围环境的影响可控制至最低程度, 影响随着施工期的结束而结束。 (4)固体废弃物 本项目施工期固体废物主要来自于施工期间土石方、施工人员的生活垃圾、 建筑施工的废料和包装材料等。 1)开挖土石方 根据项目设计方案,以自然方计算,该项目建设过程将产生土石方地基开 挖面积 32155m2 ,开挖深度 5.36m,总挖方 17.2 万 m3,填方 7.34 万 m3 ,弃方 9.86 万 m3,弃方及时运至当地政府指定地点,评价要求弃土运输车辆采取覆盖、 严禁超速、超载,并按交通管理部门指定路线及时间进行运输。 2)建筑施工的废料和包装材料 根据工程内容及统计数据,工程建设中产生的废料按 500t/10000m2 计,项 目总建筑面积 107656m2,则工程施工将产生建筑垃圾约为 5382.8t。分类收集, 可利用部分回收利用,不能利用部分运至指定建筑垃圾填埋场。 3)生活垃圾 68 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 高峰期施工人员及管理人员以 150 人计,每人每天产生 0.5kg 垃圾,施工 期间日产生活垃圾 75kg/d,经收集后由环卫部门统一清运。 (5)生态环境 项目施工过程涉及地表开挖及回填,将破坏原有地表及地表植被,雨水冲 刷活动将带来水土流失加剧现象,施工过程中加强临时堆放场的管理,制定土 方表面压实、定期喷水、覆盖、设置截排水沟等措施;不需要的泥土,建筑材 料弃渣应及时运走,不宜长时间堆积。 3.3.2 运营期污染源及其防治措施 本项目运营期污染因素主要有废气、废水、噪声和固体废物。 3.3.2.1 废水 3.3.2.1.1 主要废水污染源 项目废水包括病区医疗废水(化验室废水、门诊废水、 住院病房废水、 医务人员废水、空调冷凝水、蒸汽消毒废水、病区食堂废水)、非病区废水 (后勤办公人员废水、宿舍楼废水、普通食堂废水、空调冷凝水)。医院不使 用氰化物、 含铬等试剂, 不产生含氰、 含铬废水, 且影像科采用数码打印不 产生洗印废水,口腔科采用环氧树脂代替汞合金,不使用银汞合金,不产生无 汞废水。院区洗衣外协不设洗衣房,不产生洗衣废水。 本项目建成后总排水量合计为 220976.1m3/a,609.24m3/d。主要污染物为 COD、BOD5 、SS、氨氮、动植物油、粪大肠菌群、肠道致病菌、肠道病毒、 结核杆菌等。病区食堂废水经油水分离器处理、病区化验室废水经酸碱中和处 理后经过臭氧预消毒,然后与化粪池+臭氧预消毒处理过的病区其他医疗废水 (门诊废水、 住院病房废水、 医务人员废水、空调冷凝水、蒸汽消毒废水)、 隔油预处理过的非病区普通食堂废水、普通化粪池处理过的非病区其他生活污 水(后勤办公人员废水、宿舍楼、空调冷凝水)一起排入医院综合污水处理站 69 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 进一步处理达标后,汇入郸城县第三污水处理厂,尾水排入洺河。消毒蒸汽纯 水制备浓水和非病区空调冷凝水作为清排水直接排入医院总排口。 根据废水总量,项目建设处理规模为 710m3/d 的污水处理设施可以满足本 次工程建成后的需求。本项目地下污水处理站采用“预处理+格栅+调节池+水解 酸化+接触氧化+MBR 膜池+次氯酸钠消毒+脱氯池”处理工艺,属于《医院污水 处理工程技术规范》 (HJ2029-2013) 中对传染病医院污水的推荐工艺。 3.3.2.1.2 水质情况 项目排水主要包括医院污水和清排水合计。医院污水需要进入综合污水站 进行处理,清排水主要是消毒蒸汽用的纯水制备浓水、非病区空调冷凝水,可 直接排入医院总排污口。 进入污水站的医院污水排水量为 588.99m3/d(213842.1m3/a)。根据《医院 污水处理工程技术规范》 (HJ 2029-2013) ,一般医院污水平均 COD 浓 度为 150~300mg/L 、BOD5 浓度为 80~ 150mg/L 、 SS 浓度为 40~ 120mg/L 、氨氮浓 度为 10~50mg/L 、粪大肠菌群 1.0×106~3.0×108 个/L 。 郸城县人民医院本院区检测报告仅对污水处理站出口浓度进行检测,无污 水站进口浓度,本次评价污水站进水水质类比同一地区郸城县中心医院东区医 院 2022 年 3 月 9 日-10 日污水处理站进口污染物浓度进行评价,污水站进水水 质具体为 COD322.9mg/L、BOD577.0mg/L、NH3-N22.8mg/L、SS174.3mg/L、 粪大肠杆菌 6.55×103 个/L、动植物油 3.29mg/L、LAS100mg/L。 参照郸城县同类医院污水处理站进水水质,结合《医院污水处理工程技术 规 范 》 ( HJ2029-2013 ) , 确 定 本 项 目 废 水 污 水 站 进 水 水 质 为 pH6-9 、 COD350mg/L、BOD5150mg/L、NH3-N50mg/L、SS200mg/L、动植物油 4.0mg/L、 粪大肠菌群数 3.0×108MPN/L、LAS100mg/L。本项目废水污水站进水水质已经 过隔油、化粪池等预处理,本项目引用废水水质计算过程中不再考虑隔油措施、 化粪池的去除率。 70 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 类比其他传染病医院废水,传染性废水中肠道致病菌产生浓度为 8.5×106 个 /L、肠道病毒 6.6×106 个/L、结核杆菌 3.5×106 个/L。医院传染性废水在进入污 水站之前采用臭氧进行预消毒,臭氧消毒是《医院污水处理工程技术规范》 (HJ2029-2013)中推荐的传染病废水有限考虑的预消毒方法,消毒时间不小于 30min。根据《臭氧对细菌杀灭作用的初步研究》(孙东平等)、《臭氧对病毒 杀灭效果研究》(李玉冰等)、《臭氧在医院污水处理中的应用》(汪宝鉴等) 等,臭氧几乎对所有病菌、病毒、霉菌、真菌及原虫、卵囊都具有明显的灭活 效果,在恒定的臭氧浓度下,随着作用时间的增长(不小于 30min),臭氧对 肠道致病菌、肠道病毒、结核杆菌能达到 100%的致死率。医疗废水中肠道致病 菌、肠道病毒、结核杆菌等细菌病毒经过臭氧 30min 预消毒处理后,进入医院 地下污水处理站的医疗废水已基本不存在。 消 毒蒸 汽 用 的纯 水 制 备 浓 水 、 非 病 区 空 调 冷 凝水 量 分 别为 7008m3/a 、 126m3/a,合计 7134m3/a、20.25m3/d。根据环境保护部环境工程评估中心编制的 《社会区域类环境影响评价》(第三部)中给出软化制备浓水污染物 COD 浓度 为 20-35mg/L 本次评价按 35mg/L 计,全盐类 1000-3500mg/L 取 3500mg/L 计。 空调冷凝水为空气中水分冷凝形成不考虑全盐类,COD 浓度参考软水浓水浓度 取 35mg/L 参与计算。 3.3.2.1.3 废水处理情况 根据设计,本项目地下污水处理站采用“预处理+格栅+调节池+水解酸化+ 接触氧化+MBR 膜池+次氯酸钠消毒+脱氯池”处理工艺,属于《医院污水处理工 程技术规范》 (HJ2029-2013) 中对传染病医院污水的推荐工艺。 根据废水总量,项目建设处理规模为 710m3/d 的污水处理设施可满足本次 工程建成后的需求。本项目废水产排情况见下表 3-15。 71 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 表 3-15 本项目医院废水产排情况一览表 污染物废水类别 污水处理站进水 COD BOD5 (mg/L) (mg/L) SS(mg/L) NH3-N 动植物油 粪大肠菌群 (mg/L) (mg/L) (MPN/L) 350 150 200 50 4.0 污染物产生量(t/a) 74.8447 32.0763 42.7684 10.6921 0.8554 水解酸化去除率 10% 10% 20% 20% 0 0 项目医院地下 接触氧化去除率 40% 35% 20% 10% 0 污水处理站 MBR膜池去除率 70% 80% 85% 60% 总去除率 10% 10% 20% 56.7 17.55 12.1248 出水水质(mg/L) 213842.1m /a 3 浓水7008m /a 非病区空调 N/L) N/L) (mg/L ) / / / / 0 / / / / 0 95% / / / / 0 100.00% 0 / / / / 20% 0 0 0 / / / / 19.2 14.4 4 90 5 不得检出 3.7529 4.1058 3.0793 0.8554 19.2458 1.0692 / / / / 35 / / / / / / / / / 3500 污染物排放量(t/a) 0.2453 / / / / / / / / / 24.5280 出水水质(mg/L) 35 / / / / / / / / / / (t/a) 3 (MP (MP / 污水站出水排放量 72 100 (MPN/L) 全盐类 / (mg/L) 的纯水制备 ) 肠道致病菌 病毒 杆菌 / 污水站出水浓度 消毒蒸汽用 (mg/L 肠道 结核 / (mg/L) 3.0×108 LAS 0.6415 ×108 21.3842 不得 不得 检出 检出 / 郸城县人民医院西南院区新建项目环境影响报告书 冷凝水 126m /a 3 项目总排口 第三章工程分析 污染物排放量(t/a) 0.0044 / / / / / / / / / / 总排口排放量(t/a) 12.3745 3.7529 4.1058 3.0793 0.8554 19.2458 1.0692 / / / 24.528 56.0 17.0 18.6 13.9 3.9 87.1 4.8 不得检出 42.4 12.9 14.1 / / / / / 60 20 20 15 5 100 5 不得检出 60 20 20 / / / / / / / / 进水水质(mg/L) 500 200 300 35 / / / / / / / 浓度(mg/L) 30 / / 1.5 / / / / / / / 全院排放量(t/a) 6.6293 / / 0.3315 / / / / / / / 总排口浓度(mg/L) 220976.1m3/a 排放负荷:[g(/ 床 不得 不得 检出 检出 / / 111.0 / 位·d) ] GB18466-2005 《医疗机构水 排放浓度(mg/L) 不得 不得 检出 检出 / 污染物排放标 准》表1传染 病、结核病医 疗机构水污染 最高允许排放负荷[g (/ 床位·d) ] 物排放标准 郸城县第三污 水处理厂进水 水质要求 郸城县第三污 水处理厂出水 73 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 由前述工程分析可知,本项目废水经“预消毒+预处理+格栅+调节池+水解 酸化+接触氧化+MBR 膜池+次氯酸钠消毒+脱氯池”污水处理站处理后,污染物 排放浓度 COD56.0mg/L、BOD517.0mg/L、SS18.6mg/L、NH3-N13.9mg/L、动 植物油 3.9mg/L、粪大肠菌群数 87.1MPN/L、LAS4.8mg/L、肠道致病菌及肠道 病毒、结核杆菌不得检出,能够满足《医疗机构水污染物排放标准》 (GB18466-2005)表 1 传染病、结核病医疗机构水污染物排放浓度。COD、 BOD5、SS 排放负荷分别为 42.4g(/ 床位·d)、12.9g(/ 床位·d)、14.1g(/ 床 位 ·d ) , 能 够 满 足 GB18466-2005 中 表 1 最 高 允 许 排 放 负 荷 标 准 要 求 要 求 “COD60g(/ 床位·d)、BOD520g(/ 床位·d)、SS20g(/ 床位·d))”,同时 也可以满足郸城县第三污水处理厂进水水质要求。 为降低污水中余氯含量,消毒池后设置脱氯池投加脱氯剂(硫代硫酸钠), 确保出口总余氯限值为 6.5~10mg/L,满足《医疗机构水污染物排放标准》 (GB18466-2005)表 1 接触池出口总余氯浓度要求。 根据周口市生态环境局文件<关于郸城县第三污水处理厂建设工程环境影响 报告表的批复>》、根据《周口市 2019 年水污染防治攻坚战实施方案》及中共 河南省委、河南省人民政府发布的《加强生态环境保护打好污染防治攻坚战责 任书》(2018-2020)中的要求及环评报告,郸城县第三污水厂出水水质执行 《城镇污水处理厂污染物排放标准》(GB18918-2002)一级 A 标准同时满足 《 地 表 水 环 境 质 量 标 准 》 ( GB3838-2002 ) IV 类 要 求 。 按 IV 类 水 体 水 质 COD30mg/L 、 氨 氮 1.5mg/L 计 算 , 项 目 排 入 外 环 境 的 废 水 总 量 指 标 为 COD6.6293t/a,NH3-N0.3315t/a。 3.3.2.2 废气 本项目产生的废气主要为含菌废气、检验废气、泊车位汽车废气、食堂油 烟、地下污水处理站产生的恶臭、垃圾收集站恶臭、备用柴油发电机燃烧废气。 1、含菌废气 74 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 本项目医疗区、病房区通风废气可能含传染性的细菌和病毒,本项目拟通 过紫外灯照射的方式消毒,以减轻对环境的影响。基于病毒致病机理、条件等 差异,对项目产生含菌气体可能对周围环境的影响很难作准确的定量分析,本 评价根据医院室内空气消毒的要求对本项目产生的含细菌废气对周围环境的影 响进行分析。根据《医院消毒卫生标准》(GB15982-2012)中规定,各类环境空 气、物体表面细菌菌落总数卫生标准见下表。 表 3-16 各类环境空气、物体表面、医护人员手细菌菌落总数卫生标准 环境 类别 I类 空气平均菌落数a 范围 cfu/m3 物体表面 cfu/m3 cfu/m3 ≤150 ≤5.0 ≤4.0(15min) — ≤5.0 ≤4.0(5min) — ≤10.0 ≤4.0(5min) — ≤10.0 洁净手术部 符合GB5033要求 其他洁净场所 ≤4.0(30min)b 非洁净手术部(室);导管室;血液病病 II类 区、烧伤病区等保护性隔离病区;重症监 护病区等 消毒供应中心的检查包装火菌区和无菌 III类 物品存放区;血液透析中心(室);其他普 通住院病区等 IV类 普通门(急)诊及其检查、治疗室;感染性 疾病科门诊和病区 a:CFU/m3 为平板暴露法;CFU/m3 为空气采样器法。b:平板暴露法检测时的平板暴露时 间。 I 类环境只能采用层流通风,能使空气中的微生物减到此标准以下;II 类环 境为有人房间,必须采用对人无毒无害,且可连续消毒的方法,可选用循环风 紫外线空气消毒|器或静电吸附式空气消毒器;II 类、IV 类环境包可采用臭氧消 毒、紫外线消毒、熏蒸或喷雾消毒。 本项目病区含菌废气采用紫外线杀毒后经专用排风烟道引至楼顶排放;手 术室、负压病房采用全新风直流式空调系统,送风应经过初效、中效、高效过 滤器三级处理,排风经过高效过滤器过滤处理后经过专用风道引至楼顶排放。 75 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 通过以上措施,可以减轻含菌废气对环境的影响,使各科室内细菌总数符 合《室内空气中细菌总数卫生标准》(GB/T17093-1997)室内空气中细菌总数规 定撞击法≤4000cfu/m3 规定;经消毒后,医院内各类环境空气的细菌总数均低 于室内空气卫生标准,含菌气体经消毒后在室外经扩散和稀释后对最近居民区 基本无影响。 2、检验废气 本项目在检验过程中使用少量有机试剂等 (如酒精、甲醇、二甲苯等) ,这 些物质具有一定的挥发性,日常封闭储存,使用时会产生少量的挥发性有机 废 气等。该部分废气的挥发量很少,检验过程均采用全自动分析设备,只需将药 剂和样品放进设备内,即可自动进行化验得出结果,整个过程均由密闭的设备 进行,检验室内设有安全柜,检验废气经安全柜自带的高效空气过滤器处理后 去除致病细菌、生物气溶胶及其他污染物有害气体后,再引至楼顶排放,排气 中的致病细菌及生物气溶胶可被除去,减轻对环境和周围环境的影响,同时医 院做好检验室内的消毒卫生工作,确保检验废气处理后不会对周围环境造成明 显影响。高效过滤器过滤原理是采用了活性炭的吸附作用,不仅可以去除粉尘、 烟雾和有机、无机污染物,还可以在空气中去除异味和有害气体。参考《医院 消毒卫生标准》(GB15982-2012),高效空气过滤器是可行的含菌废气消毒措施。 3、泊车位汽车尾气 本项目设置 1140 个机动车泊车位,车辆进出泊车位时会产生汽车尾气。汽 车尾气主要是指汽车在怠速及慢速(≤5km/h)状态下排放的尾气,主要污染因 子为 CO、THC、NOX 等。 本项目汽车尾气属于无组织排放,地上车库空旷尾气极易消散影响不大, 地下车库安装抽排风系统,加强地下车库空气流通,产生的汽车尾气对周围环 境影响较小。 4、食堂油烟废气 76 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 项目设置 2 个食堂,后勤办公综合楼内设置 1 个食堂供后勤办公人员就餐 (就餐人员 300 人,设 2 个灶头),门诊医技综合楼设置 1 个食堂供医护人员 及病患就餐(就餐人员 2500 人,设 12 个灶头)。食堂提供病房送餐服务。 项目医院食堂规模为大型食堂,每个灶头风量 2000m3/h 计。食堂在烹饪过 程将会产生废气污染物,主要污染因子为油烟及其中含有的挥发性有机物 (VOCs)。 根据类比调查,食堂一般的食用油耗油系数为 20g/(人·d),则本项目耗 油量 20.44t/a。一般油烟挥发量占总耗油量的 2~4%,本项目按 3%取值,则油 烟产生总量为 0.6132t/a(后勤办公综合楼食堂 0.0657t/a、门诊医技综合楼食堂 0.5475t/a)。 根据《餐饮油烟中挥发性有机物风险评估》(环境科学研究,第 25 卷第 12 期,2012 年 12 月),烹饪油烟 VOCS 排放因子为 5.03g/kg,经气相色谱-质 谱联用仪(GC-MS)实地监测分析得出,厨房油烟 VOCS 主要污染物为乙醇和 丙烷,另包括醛类、烯烃和含氧有机物等,大部分属非甲烷总烃,因此本项目 VOCS 以非甲烷总烃作为控制和预测因子。本项目耗油总量为 20.44t/a(后勤办 公综合楼食堂 2.19t/a、门诊医技综合楼食堂 18.25t/a),则本项目食堂在烹饪过 程中非甲烷总烃产生量为 0.1028t/a(后勤办公综合楼食堂 0.0110t/a、门诊医技 综合楼食堂 0.0918t/a)。 本项目 2 个食堂共设置 14 个天然气基准灶头,每个灶头排气量以 2000m3/h 计,年工作日 365 天,日工作时间约 6h,则废气产生量为 438 万 m3/a,评价建 议该食堂安装“高效静电式油烟净化器”对食堂油烟废气进行处理。高效静电式 油烟净化器对油烟去除效率应大于 95%,本次评价按 95%计,对非甲烷总烃去 除效率约 70%。 本项目后勤办公综合楼食堂油烟经高效静电式油烟净化器处理后,项目建 成后油烟总排放量为 0.00329t/a、0.0015kg/h,排放浓度为 0.375mg/m3,非甲烷 总烃总烃排放量为 0.00330t/a、0.0015kg/h,排放浓度为 0.377mg/m3。满足河南 77 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 省 地 方 标 准 《 餐 饮 业 油 烟 污 染 物 排 放 标 准 》 ( DB41/1604-2018 ) ( 油 烟 1.0mg/m3,非甲烷总烃 10.0mg/m3),由专用排烟通道引至后勤办公综合楼楼 顶排放。 本项目门诊医技综合楼食堂油烟废气经 1 套废气处理设施处理后,项目建 成后油烟总排放量为 0.0274t/a、0.0125kg/h,排放浓度为 0.521mg/m3,非甲烷 总烃总烃排放量为 0.0275t/a、0.0126kg/h ,排放浓度为 0.524mg/m3。满足河南 省 地 方 标 准 《 餐 饮 业 油 烟 污 染 物 排 放 标 准 》 ( DB41/1604-2018 ) ( 油 烟 1.0mg/m3,非甲烷总烃 10.0mg/m3),由专用排烟通道引至门诊医技综合楼楼 顶排放。 5、生活垃圾收集站恶臭 该项目设专门的垃圾收集站房,院区的生活垃圾由密闭式塑料垃圾桶收集 大生活垃圾收集点,每天由环卫部门集中清运处理,生活垃圾收集站不进行垃 圾处理、无压缩工艺。在生活垃圾的收集、转运过程中,部分易腐败的有机垃 圾由于分解会释放出异味,对环境的影响主要表现为恶臭,其主要成分是 H2S、 NH3。 垃圾恶臭气体是多组分、低浓度化学物质形成的混合物,污染物成分复杂, 成分和含量均较难确定,目前尚无垃圾收集点恶臭气体产生量的计算方法,根 据经验,垃圾收集点产生的恶臭很轻微,对环境无明显影响。 评价要求采取的措施:垃圾袋装化,可有效防止生活垃圾收集站)H2S 和 NH3 等恶臭污染物散发,必要时使用除臭剂;尽量减少垃圾暴露时间,及时清 运,日产日清,夏季增加清运次数。 6、地下污水处理站产生的恶臭 本项目地下污水处理站恶臭气体主要为院内污水处理站处理废水过程中由 于微生物、原生动物、菌股团等生物的新陈代谢而产生的恶臭气体,其主要成 分为臭气浓度、H2S、NH3 等。 78 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 本项目建成后医院污水站处理水量为 213842.1t/a,医院污水采用“预消毒+ 格栅+调节池+水解酸化+接触氧化+MBR 膜池+次氯酸钠消毒+脱氯池”的处理工 艺,臭气主要产生于格栅、调节池和沉淀池、污泥脱水间。 收集措施:本项目污水站设为地下,为减少恶臭气体排放对周围环境产生 的影响,污水处理装置各构筑物池顶均加盖封闭,盖板上预留进、出气口,出 气口设置排气管道,产生的恶臭经风机引至恶臭气体处理设施处理;污泥脱水 间封闭,采用引风机将废气引入废气处理设施处理。采取上述措施处理后,恶 臭基本不存在无组织排放。本次评价污水站恶臭收集率按 100%收集,不再考 虑无组织排放。 处理措施及排气筒设置:废气处理设施采用生物(滤池)除臭+紫外线消 毒 经 管 道 引 至 附 近 病 房 楼 楼 顶 排 放 ( 20m 高 , 周 边 最 近 病 房 楼 设 计 高 度 18.65m)。采取上述措施后拟建工程地下污水处理站的恶臭不会对项目区的病 房、门诊区以及周边环境敏感点产生明显影响。 地下污水处理站投入运行后,会产生一定量的恶臭气体,主要成分为臭气 浓度、 H2S 和 NH3 ,根据调查 , 每处理 1g 的 BOD5 可 产生 0.003g 的 NH3 、 0.00012g 的 H2S。全院消减 BOD5 的量 28.3234t/a,则产生 H2S 和 NH3 分别为 0.0034 t/a、0.0878 t/a。 本项目臭气浓度类比郸城县人民医院本院区监测,厂界污水站臭气浓度有 组织产生值为 1373-2443(无量纲)。经类比本项目臭气浓度产生量取值 2500 (无量纲),采用生物除臭处理设施处理效率约为 70%,臭气浓度排放量为 750(无量纲)。本项目废气产生源强见表 3-17。 表 3-17 地下污水处理站废气产生、排放一览表 大气 污染源 污染 物 污水 站恶 风量 产生 m3/h 量t/a 全院 H2S 2000 速率 浓度 kg/h mg/m3 0.003 0.000 4 脱 产生 产生 4 0.194 79 防治 臭 排放 排放速 措施 效 量t/a 率kg/h 率 负压 70 收集+ % 排放 运行 浓度 时间 mg/m3 (h) 0.0010 0.0001 0.05 8 每天 24h 郸城县人民医院西南院区新建项目环境影响报告书 臭排 NH3 气筒 0.087 8 第三章工程分析 生物 0.010 5.012 0.0263 0.0030 1.503 除臭+ 紫外线消毒 臭气 浓度 365 天/ 2500 后经管道引 / , 750 / (无 至附近病房 量纲) 楼楼顶排放 / 年 (无 量纲) (约20m) 由上表可知,本项目地下污水处理站恶臭经“负压抽吸+生物除臭+紫外线消 毒”处理后经管道引至附近病房楼楼顶排放(20m 高,周边最近病房楼设计高度 18.65m),全院臭气浓度、H2S、NH3 排放速率均满足《恶臭污染物排放标准》 (GB14554-93) 表 2 标 准 要 求 ( 臭 气 浓 度 2000 ( 无 量 纲 ) 、 H2S0.58kg/h 、 NH38.7kg/h)。 7、备用柴油发电机燃烧废气 本项目配备有 1 台柴油发电机组,其排放的燃油废气中主要包含 CO、 NOx 等污染物。备用发电机在供电正常时不使用,只有在停电情况下才会使用, 发电时间短,全年使用时间少,废气排放量少,采用轻质柴油作为燃料,污染 物排放量极少,故不再进行定量分析。发电机废气经过自带的净化装罝处理后, 通过专用烟道引至楼顶排放。 3.3.2.3 噪声 本项目营运期间主要噪声源为中央空调风冷热泵机组、污水站风机、食堂 风机、水泵房水泵、液氧站空压机等运转产生的噪声。除中央空调风冷热泵机 组位于楼顶,污水站风机、水泵房均设置在地下。本项目拟对所有有振动的设 备均设减振基础或吊架,接管采用柔性减振接头,对所有送、排风系统作消声 处理、减振等降噪措施。本项目高噪声设备拟采取治理措施及排放源强见表 318。 表 3-18 主要噪声源情况 序号 设备名称 噪声值[dB] 数量(个) 门诊医技综合 1 楼中央空调风 90 治理措施 设置楼顶、隔声罩、消声、 1 减振 冷热泵机组 80 排放源强[dB] 65 郸城县人民医院西南院区新建项目环境影响报告书 呼吸道楼中央 2 空调风冷热泵 90 1 90 1 90 1 设置楼顶、隔声罩、消声、 减振 机组 发热门诊中央 3 空调风冷热泵 设置楼顶、隔声罩、消声、 减振 机组 后勤办公综合 4 楼中央空调风 第三章工程分析 设置楼顶、隔声罩、消声、 减振 冷热泵机组 地下、减振、构筑物隔声、 65 65 65 5 水泵房水泵 85 1 6 污水站风机 85 1 85 1 减振、隔声罩隔声、消声 55 85 1 减振、隔声罩隔声、消声 55 85 1 7 8 9 后勤办公综合 楼食堂风机 门诊医技综合 楼食堂风机 液氧站空压机 消声 地下、减振、构筑物隔声、 消声 设置室内,减振、构筑物隔 声、消声 55 55 55 3.3.2.4 固体废物 医院是人群及患者活动、治疗、检查和生活的集中场所,在正常运营过程 中产生的固体废物包括医务后勤人员办公及宿舍产生的普通生活垃圾、餐厨垃 圾、废反渗透膜(纯水制备)、门诊、病房楼病人产生的生活垃圾(属于医疗 废物)、医疗废物、污水处理站产生的栅渣及污泥、废紫外线含汞灯管。 1、生活垃圾 包括门诊、病房楼病人产生的生活垃圾,医务后勤人员办公及宿舍产生的 普通生活垃圾、餐厨垃圾。 门诊、病房楼病人产生的生活垃圾(医疗废物):本项目为传染病医院, 住院病房全部按照传染病病房标准建设,设病床 800 张,门 诊接诊量 2400 人/d, 按 每 个 床 位 生 活 垃 圾 产 生 量 0.5kg/d 计 算 , 就 诊 病 人 生 活 垃 圾 产 生 量 按 0.2kg/d ·人计,则住院及门诊病人产生的生活 垃圾量为 0.88t/d ,即 321.2t/a 。 根据《医疗废物管理条例》 “第三条 医疗卫生机构收治的传染病病人或者疑 81 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 似传 染病病人产生的生活垃圾,按照医疗废物进行管理和处置” 。门诊、病房 楼病人产生的生活垃圾全部按感染性医疗废物管理。属于《国家危险废物名 录 (2021 年版) 》HW01 卫生 841-001-01 类废物,项目门诊及病房楼产生的生活 垃圾经袋装收集后,暂存于医疗废物暂存间内,并按照医疗废物进行暂存管理 和处置,定期交由有资质单位进行清运处置。 医务后勤人员办公及宿舍产生的普通生活垃圾:本项目劳动定员 1200 人, 宿舍 400 人,按人均生活垃圾产生量 0.5kg/d 计算,则生活垃圾产生量为 0.8t/d ( 292t/a)。生活垃圾分类收集后,日产日清,每天由环卫部门负责清运至市政垃 圾中转站,最终运至郸城县生活垃圾焚烧厂发电厂焚烧。 餐厨垃圾:项目食堂用餐人次为 2800 人/天,餐厨垃圾产生量按 0.5kg/人 次 ·d 计算,则餐厨垃圾产生量为 1.4t/d (511t/a ) 。餐厨垃圾采用专用餐厨垃 圾收集桶收集,集中收集后交由有资质的单位进行运输处 置。 2、反渗透膜 纯水制备系统废反渗透膜的更换周期为五年,每年平均产生量约为 0.1t/a, 更换后随生活垃圾一同交环卫部门清运处理。 3、污水处理站产生的污泥、栅渣 在医院废水处理过程中,大量悬浮在水中的有机、无机污染物和致病菌、 病毒、寄生虫卵等沉淀分离出来形成污泥和栅渣,若不妥善消毒处理,任意排 放或弃置,同样会污染环境,造成疾病传播和流行。 参比《医院污水处理技术指南》,并类比同类工程,每处理 1 万污水产生 10t 污泥(80%),项目进入污水站处理的污水量为 213842.1m3/a,则经核算, 污水站污泥产生量约为 213.8421t/a(含水率 80%)。本项目产生的污泥含有病 菌等物质,根据《医院污水处理工程技术规范》(HJ2029-2013)规定,污泥在 清掏前应进行消毒(消毒剂采用生石灰)并投加聚丙烯酰胺,消毒后满足《医 疗机构水污染物排放标准》(GB18466-2005)“表4医疗机构污泥控制标准”, 再进行板框压滤机(高压隔膜板框压滤机处理后含水率可达到 45-60%,按 82 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 60%统计 106.9211t/a)压滤脱水后后并投加石灰(投加石灰量为 80%水分污泥 量的 10~15%,按 12%计算为 25.66t/a)处理后污泥含水量可控制在 50%左右, 处理后污泥产生量约为 132.5821 t/a(含石灰量)。 本项目污水处理站格栅过滤过程会产生栅渣,栅渣产生量 0.01~0.03m3/103m3 污 水 , 取 值 0.03m3/103m3 污 水 , 本 项 目 污 水 处 理 量 为 213842.1m3/a,则栅渣产生量 6.4153 m3 ,每立方栅渣约 0.6t,故栅渣产生量为 3.8492 t/a。 根据《医疗机构水污染物排放标准》(GB18466-2005)4.3.1 明确规定污水 处理站和栅渣属于危险废物,危废代码为(HW01 医疗废物 841-001-01)。 污泥和栅渣在污泥消毒池中一同进行消毒,消毒池有效容积应不小于处理 系统 24h 产泥量,且不宜小于 1m3,贮泥池内需采取搅拌措施,以利于污泥加 药消毒。污泥和栅渣消毒一般采用化学消毒方式。常用的消毒药剂为石灰粉和 漂白粉。采用石灰消毒,石灰投量约为污泥量的 10~15%,使 PH 为 11~12,搅 拌均匀接触 30~60min,并存放 7 天以上。污水处理站污泥和栅渣由于含有致病 菌、病毒、寄生虫卵等,属于危险废物,必须进行无害化处理。评价建议首先 采用石灰法对污泥进行消毒,石灰投加量为 90g/m3,pH 值达到 12 以上,接触 时间 2h 以上可杀灭 99.99%的大肠菌群。消毒后的污泥和栅渣可以达到蛔虫卵 死亡率大于 95%,且大肠菌群数不大于 100MPN/g,满足《医疗机构水污染物 排放标准》(GB18466-2005)表 4 要求。石灰消毒法运行费用低、效果稳定, 被广泛应用于医院污泥消毒处理,选用该方法对污泥进行消毒处理措施可行。 项目污泥和栅渣经消毒后需进行压滤脱水,本项目设置 25m2 污泥脱水间, 污泥在污泥脱水间经板框压滤机(高压隔膜板框压滤机)压滤脱水后在危废暂 存间暂存,定期外运交由有资质单位处理,压滤废水回到污水处理设施进行处 理后达标排放。 4、废紫外线含汞灯管 83 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 本项目污水处理站恶臭废气采用生物除臭+紫外线消毒工艺处置,医疗废气 等使用紫外线消毒,使用过程中紫外线灯管定期更换,一般 6 个月更换一次, 每次更换约 40 支,每年更换约 80 支,每支灯管重量约 2kg,年产生灯管重量 约 0.16t/a。根据《国家危险废物名录(2021 年版)》,废紫外线灯管为 HW29 含汞废物 900-023-29 类废物。更换后暂存于危废暂存间 25m2 内,定期交由有资 质单位处置。 5、医疗废物 根据国家环保部的统计方法,医疗废物的产生量核算:省会城市、计划单 列市按照每个床位每天 0.6kg 计算;地级市、地区所在城市,按照每个床位每 天 0.48kg 计算;一般城市、县级市按照每个床位每天 0.4kg 计算;全国平均按 照每个床位 0.51kg 计算。本次评价取 0.51kg/(床位·d),项目建成后医疗废物总 产生量为 148.92t/a。 对照《医疗废物分类目录》(2021 年版)、《国家危险废物名录》(2021 年版),项目医疗废物种类、类别及代码如下表: 表 3-19 医疗废物分类及产生位置一览表 序号 类别 危废类别及代码 项目类别 名称 代码 产生来源 1.被患者血液、 体液、 排泄物等污染 的除锐器以外的废物;2.使用后废弃 的一次性使用医疗器械, 如注射器、 感染 1 性废 HW01 物 841-00101 输液器、透析器等;3.病原微生物实 验室废弃的病原体培养基、 标本, 菌 种和毒种保存液及其容器; 其他实验 室及科室废弃的血液、血清、 分泌物 等标本和容器;4.隔离传染病患者或 门诊、 病 房配液室、 化验室、 治疗室、 手术室、 护士站等 者疑似传染病患者产生的废弃物。 1.废弃的金属类锐器, 如针头、 缝合 病理 2 性废 物 HW01 841-00301 针、 针灸针、 探针、穿刺针、 解剖 门诊、 治 刀、 手术刀、 手术锯、 备皮刀、 钢 疗室、 手 钉和导丝等;2.废弃的玻璃类锐器, 术室等 如盖玻片、 载玻片、 玻璃安瓿等;3. 84 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 废弃的其他材质类锐器。 1.手术及其他医学服务过程中产生的 废弃的人体组织、 器 官;2.病理切片 损伤 3 性废 HW01 841-00201 物 后废弃的人体组织、 病理蜡块;3.废 弃的医学实验动物的组织和尸体; 4.16 周胎龄以下或重量不足 500 克的 手术室、注 射室等 胚胎组织等;5.确诊、 疑似传染病或 携带传染病病原体的产妇的胎盘。 药物 4 性废 HW01 物 841005-01 性废 性药物和遗传毒性药物;3.废弃的疫 治疗室等 苗及血液制品。 列入《国家危险废物名录》 中的废弃 化学 5 1.废弃的一般性药物;2.废弃的细胞毒 HW01 物 841- 危险化学品, 如甲醛、 二甲苯等; 消毒室、配 004-01 非特定行业来源的危险废物, 如含汞 液室等 血压计、 含汞体温计等。 类比郸城县人民医院本部院区医疗废物统计情况,项目医疗废物产生情况 见下表: 表 3-20 本项目医院废物产生情况 年产生量t/a 医疗废物类型 合计 感染性废物 134.45 损伤性废物 0.53 病理性废物 12.09 药物性废物 1.79 化学性废物 0.83 合计 149.69 各类医疗废物分类收集后在医疗废物暂存间(50m3)暂存后,委托有资质 单位进行集中处理。 为确保医疗固废的安全处置,国家对医院从固废源头控制、暂存、移交等 方面均有相关的管理措施和要求,结合本医院实际情况具体如下: (1)医疗废物管理的一般规定 本项目应建立、健全医疗废物管理责任制,切实履行职责,同时应制定相 应的事故应急预案,防止因医疗废物导致传染病传播和环境污染事故。对本单 85 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 位从事医疗废物收集、运送、贮存、处置等的工作人员进行培训,并配备相应 的职业卫生防护措施。对本项目产生的医疗废物实行登记制。登记内容编包括 医疗废物的来源、种类、重量、数量、交接时间、处置方法、最终去向及经办 人等项目,登记资料至少要保存三年。 (2)医疗废物的具体管理措施和要求 ①分类收集 分类收集是减少危害和安全处理的前堤。收集废物所使用的容器主要是塑 料袋、锐器容器和废物箱等。本项目医疗固废主要包括各种感染性废物、病理 性废物、损伤性废物、药物性废物和化学性废物,应按照《危险废物识别标志 设置技术规范》(HJ 1276—2022)设置危险废物识别标识。 感染性废物:主要分布在门诊、化验、医技室和病房等。根据要求,各诊 室应分别配备专用的废物塑料袋和专用密闭的容器,将各种易收集的如化验标 本、各种敷料等感染性废物收集于专用的塑料袋中,废物塑料袋应有清晰的颜 色标志和注明用途,并放在相应的污物桶中。需高压灭菌(或其他消毒处理) 的废物袋应采用合适的材料制造,并作颜色标记,可加有标志以显示是否经过 所规定的处理程序(如高压消毒指示袋等),袋子上还应有清晰的文字标志, 如“需消毒废物”或“无危害标志”。高压灭菌(或其他消毒处理)后的废物袋小 容器应放入另一种颜色标记的袋子或容器中,以便进行下一步的处置。 损伤性废物:指用过废弃的或一次性的注射器、针头、玻璃、锯片、解剖 刀、手术刀片及其他可能引起切伤刺伤的器物。这些废物不应与其它废物混放, 用后应稳妥安全地置入密闭的锐器容器中。锐器容器应标以适当的颜色,并用 文字清晰标明专用,并以国际标志符号标志,如“只能用于锐器”、“生物危险 品”。病理性废物:主要分布在手术室、诊室等,主要为如手术室的人体组织等 废物。医院应在此区设置废物收集设施,该类废物应使用双层废物袋,应用密 封与处理的废物桶(如聚乙烯或聚丙烯塑料桶,容量 30~60L),装满之后应 立即封闭。药物性废物和化学性废物:主要为过期的各种药品和各种废气的化 86 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 学消毒剂和含汞血压计、温度计等,可在各诊室和检验科设置专门的密闭容器。 待一定量时和医疗废物一起进行处置。 所有废物都应丢弃或放入标明适当颜色或标识的垃圾袋或污物桶中,在装 满 3/4 时有人负责封袋,废物一旦放入废物箱后就不宜再取出。医院中有传染 性和有害的污物不能混在一起,若混在一起则应按有害废物处理。 ②废物袋的搬运与集中 污物袋要定期收集。废物袋应每日运出病房或科室,也可根据需要决定搬 运时间,无标志的废物袋不应搬出,而且应保证安全并防止泄漏。封好的锐器 容器或圆形废物桶搬出病房或科室之前应有明确标志。废物袋应及时更换,任 何情况下都不能用普通袋代替有害废物袋。病房中应同时有 2 种类型的废物袋。 废物袋的大小应根据需要确定,尽量满足各种需要,应保证外袋颜色相符,袋 内可衬以不同颜色和强度的内袋,工作人员应确保废物离开病房或科室时装入 颜色相符的袋子中。医院内废物应在病区、科室与废物中心存放地之间设计规 定转运路径,以缩短医院内废物通过病区与其它清洁区的路线。使用专用手推 车将废物袋(箱)运至废物中心存放地时,手推车应是专门设计的,外形美观, 装卸方便,有任何泄漏时均应彻底清洁与消毒。 ③暂存 废物袋(箱)在就地处理或异地处理之前,需在医院中心废物存放地集中 暂存,该暂存设施不得漏天存放医疗废物,易腐败的生物废物需贮存于中心存 放地或病室内的冰箱、冰柜内。医疗废物在医院内的暂存时间不得超过 2 天, 同时医院暂存设施应远离医疗区和食品加工区和人员活动区,应和普通垃圾分 开存放, ④移交 本项目产生的各种医疗废物拟委托郸城县医疗固废处置场所集中收集处理, 按照《医疗废物管理条例》相关要求,医院在医疗废物的转移方面应依照《中 87 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 华人民共和国固体废物污染环境防治法》的规定,严格执行危险废物转移管理 制度。即医院在转移危险废物在运营过程中具体应做到: a、医院在转移医疗废物前,须按照国家有关规定报批危险废物转移计划; 经批准后,产生单位应当向移出地环境保护行政主管部门申请领取联单。 b、医院每转移一车(次)同类危险废物,应当填写一份联单。 c、医院应当如实填写联单中产生单位栏目,并加盖公章,经交付危险废物 运输单位核实验收签字后,将联单第一联副联自留存档,将联单第二联交移出 地环境保护行政主管部门,联单第一联正联及其余各联交付运输单位随危险废 物转移运行。 d、联单保存期限为五年,贮存危险废物的,其联单保存期限与危险废物的 贮存期限相同。 ⑤医疗废物暂时贮存库房的要求 a、必须与生活垃圾存放地分开,有防雨淋的装置,地基高度应确保设施内 不受雨洪冲击或浸泡; b、必须与医疗区和人员活动密集区隔开,方便医疗废物的装卸、装卸人员 及运送车辆的出入; c、应有严密的封闭措施,设专人管理,避免非工作人员进出,以及防鼠、 防蚊蝇、防蟑螂、防盗以及预防儿童接触等安全措施; d、地面和 1.0 米高的墙裙须进行防渗处理,地面有良好的排水性能,易于 清洁和消毒,产生的废水应采用管道直接排入医疗卫生机构内的医疗废水消毒、 处理系统,禁止将产生的废水直接排入外环境; e、库房内应张贴“禁止吸烟、饮食”的警示标识; f、应按《环境保护图形标志—固体废物贮存(处置)场》(GB 15562.21995)修改单和卫生、环保部门制定的专用医疗废物警示标识要求,在库房外 的明显处同时设置危险废物和医疗废物的警示标识。 本项目固体废物产排情况见下表。 88 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 表 3-21 固体废物产排情况一览表 t/a 序号 污染物 产生途径 固废性质 全院产生量t/a 处理措施 生活垃圾分类收集后, 医务后勤人员 1 日产日清,每天由环卫 办公及宿舍产 医务后勤人员 生的普通生活 办公及宿舍 一般固废 292 垃圾 部门负责清运至市政垃 圾中转站,最终运至郸 城县生活垃圾焚烧厂发 电厂焚烧 采用专用餐厨垃圾收集 2 餐厨垃圾 食堂 一般固废 511 桶收集,集中收集后交 由有资质的单位进行运 输处 置 3 废反渗透膜 (纯水制备) 纯水制备 一般固废 0.1 更换后随生活垃圾一同 交环卫部门清运处理 经袋装收集后,暂存于 门诊、病房楼 4 医疗废物暂存间内,并 病人产生的生 门诊、病房楼 活垃圾(属于 病人 医疗废物 321.2 医疗废物) 按照医疗废物进行暂存 管理和处置,定期交由 有资质单位进行清运处 置 5 6 7 8 医疗废物 污水处理站产 生的污泥 污水处理站产 生的栅渣 废紫外线含汞 灯管 门诊科室及 病房楼 污水处理站 医疗废物暂存间暂存 危险废物 148.92 后,委托有资质单位进 行集中处理 危险废物 132.5821 消毒脱水后,作为危险 废物定期交有资质单位 污水处理站 危险废物 3.8492 紫外线消毒 危险废物 0.16 处置 危废间暂存后交由有资 质单位处置 3.4非正常工况 根据项目特点和污染源特征,本项目非正常工况主要是废气处理措施异常, 不能达到预期处理效率,此时排放的污染物可能会对环境产生不利影响,非正 常工况的持续时间约为 1h。当废气处理措施发生异常时,按最不利情况考虑, 非正常排放时处理措施净化效率为 0。则非正常工况下污染物排放量见下表。 89 郸城县人民医院西南院区新建项目环境影响报告书 第三章工程分析 表 3-22 本项目非正常工况下气体排放情况一览表 污染源 名称 后勤办 公综合 楼食堂 排气筒 门诊医 技综合 楼食堂 排气筒 地下污 水处理 站恶臭 排气筒 污染物名称 非正 常工 况 非正常工况排放情况 排放速率kg/h 排放时间 排放量kg 排放浓度 mg/m3 油烟 0.03 1h 0.03 7.5 非甲烷总烃 0.0050 1h 0.0050 1.3 油烟 0.25 1h 0.25 10.4 0.0419 1h 0.0419 1.7 NH3 0.0004 1h 0.0004 0.194 H2S 0.010 1h 0.010 5.012 臭气浓度 / 1h / 非甲烷总烃 去除 效率 为0 2500(无 量纲) 当发生非正常工况时,建设单位应立即更换环保设施并加强环保设施日常维修 管理。 90 郸城县人民医院西南院区新建项目环境影响报告书 第四章环境现状调查与评价 第四章环境现状调查与评价 4.1自然环境概况 4.1.1 地理位置 郸城县位于河南省东部的豫皖交界处,为两省(河南省、安徽省)两市 (周口市、阜阳市)交接地带。介于北纬 33°25′~33°49′,东经 115°00′~115°38′ 之间。北依鹿邑县,西连淮阳县,南接沈丘县,东南和东部与安徽省界首县、 太和县和亳州市为邻,东西长 58.9km,南北宽 43.5km。全县总面积 1471km2。 郸城县开发区位于郸城县县城东部,用地范围北至新修郸城至淮阳一级公 路、南至新修 S329 绕城公路、西至东环路、东至杨白河,规划面积为 15.0km2。 其中起步区 5.3km2,发展区 2.0km2,控制区 7.7km2。郸城县高新技术开发区是 豫皖交界处重要的食品加工和生物医药基地、郸城县主要的经济增长极,环境 优美、设施齐全、功能完善的城市新功能区。 本项目位于郸城县科技大道北、公园西路西侧地块,具体位置见附图 1。 4.1.2 地形地貌 郸城县地处黄河冲积扇的南部边缘的一部分,地势由西北向东南微缓倾斜, 海拔在 35.6m 至 43.8m 之间,相对高差最大为 8m,地面坡降平均为 1/7000。境 内南、北部较高,、东部稍低,略呈向东南开口的簸箕形浅平洼地。地貌分为 冲积平原和冲积湖积平原两种类型,冲积平原主要是黄河南徙,由沙颖河和涡 河泛道泥砂堆积而成,南部分布在新蔡河以南和以东地区,北部分布在洺河上 游和革新河、黑河以北广大地带,常见的有高平地、平坡地、坡洼地等地貌单 元;冲积湖积平原主要分布在南、北部冲积平原间的中、东部广阔地带,地形 平坦,平原上坡洼地星罗棋布。大小洼地 60 个,面积达 63.38 万亩,洼地高差 最大 2m,一般在 1m 左右。区域地质构造位于华北断块盆地周口坳陷之中。除 北部几个乡居鹿邑凹陷,东南部属沈丘凹陷外,其主体部位均位于郸城凸起之 上。本项目所在区域地势平坦,适合本项目的建设。 4.1.3 水文 91 郸城县人民医院西南院区新建项目环境影响报告书 第四章环境现状调查与评价 4.1.3.1 地表水资源 郸城县地表水资源比较丰富,境内大小河流有 60 余条,均属淮河水系,主 要河流有黑茨河、洺河等。 黑茨河:黑茨河原是颍河的支流,于阜阳县茨河铺注入颍河。豫、皖省界 张胖店以上称黑河,以下称茨河,故又统称黑茨河。上游分两支,北支为李贯 河,南支为黑河。以李贯河为主源,源出河南太康县王公府附近,流经太康、 淮阳、鹿邑、郸城、界首、太和及阜阳诸县(市)境。河道全长 185km,其中 河南省境 100km,安徽省境 85km。流域面积 2994km2,其中河南境 1738km2, 安徽境 1256km2。 洺河:发源于淮阳县石牛台,于汲冢乡李楼村进入郸城县,向东南流经汲 冢、胡集、城郊、城关、双楼、丁村、秋渠等乡镇,最后在秋渠乡牛桥东流出 县境进入安徽境内,再流经长约 46km 的流程后汇入茨河。洺河在河南省境全 长 45km,流域面积 158.5km2,郸城县境内长 40.4km,流域面积 143.5km2,是 郸城县主要纳污河道之一。杨白河:杨白河为洺河支流,其上游无天然来水, 水体来源主要为沿途工业企业排放的生产废水、自然降水及黑河调水,无水体 功能。 洺河为郸城县高新技术产业开发区污水处理厂的受纳水体,在郸城段地表 水功能规划为 V 类水体,控制断面设在杨楼闸,为省控断面。 据调查,洺河上游无天然来水,水体主要由沿途居民生活废水、沿岸工厂 企业排放的生产废水及自然降水构成,水质较差,为了改善洺河景观及水质状 况,郸城县进行了引黑济洺调水工程。此调水工程自黑河的主要支流李贯河袁 张桥涵洞始,通过智洼沟、老崔家沟、胡集西沟、革新河(崔家沟)、杨白河、 胡庄沟及胡庄涵洞进入洺河,全长 21km,该工程在 2000 年已竣工投用。调水 主要用于冲刷河道,一般的调水时期为冬季和每年的 6-10 月。 本项目废水经项目区污水处理设施处理后排入市政污水管网,进入郸城县 第三污水处理厂进行处理,处理后排水进入洺河。 92 郸城县人民医院西南院区新建项目环境影响报告书 第四章环境现状调查与评价 4.1.3.2 地下水资源 郸城县位于黄河冲积扇南沿,地质成因上部为黄淮冲积,下层为湖泊沉积。 郸城县地下水储量丰富,埋深浅,便于开采,利用量比较大,潜水埋深 6~18m, 含水层为细砂层和粉砂层,地下水走向为西北向东南流动。地下水水力坡度平 缓,一般地下水的径流速度比较缓慢。浅层地下水补给来源主要为大气降水, 其次为地表水体及河渠渗漏和灌溉水回渗补给、地下水的径流补给。排泄主要 是蒸发,其次是人工开采、河流排泄和少量侧向径流排泄。中深层承压含水层 组底板埋深为 250-300m,地层主要为第四系中、下部,由砂质粘土、粉土及中 细砂、粉细砂组成。含水层主要为中细砂、粉细砂,砂层埋深在 80-100m 以下, 上细下粗,砂层总厚 15-40m。 强富水区单井涌水量大于 3000m3/d,含水砂层为细砂、中细砂和粗中砂等; 富水区单井涌水量 1000-3000m3/d,含水砂层为粉细砂、中细砂;中等富水区单 井 涌 水 量 500 ~ 1000m3/d , 含 水 砂 层 为 粉 细 砂 等 。 地 下 水 水 化 学 类 型 为 HCO3·Cl-Ca(或 Na), 矿化度一般 500-1000mg/L。深层承压含水层组底板埋深为 500-550m 左右, 由新近系河湖相沉积物组成。岩性主要是砂质粘土、粉土及中细砂、粉细砂。 含水砂层在西南部厚度大、东北部薄,厚度 30-10m。水头埋深 12m,降深 10.44m,单井出水量为 1533m3/d。地下水化学类型主要为 HCO3-Na 型,矿化 度 500-1200mg/l。中深层上部含水层补给来源除接受侧向径流补给外,其与浅 层地下水水力联系密切,其补给受浅层地下水的影响;中深层地下水的下部及 深层含水层与上层地下水水力联系微弱,主要接受上游地下水的径流补给。地 下水径流方向为由西北向东南,水力坡度 1/3000-1/5000。主要排泄方式为开采, 其次为侧向径流排泄。 根据浅层全新统含水岩组的富水性可分为大水量区,中等水量区和小水量 区三个区域,其中大水量区:全县分布面积为 360.49km2 ,占全县总面积的 24.5%。主要分布在县内皇姑河以南,新蔡河以北,崔家沟以北、黑河以南及练 沟河两岸地区;中等水量区:全县分布面积为 561.21km2,占全县面积的 38.2%。 93 郸城县人民医院西南院区新建项目环境影响报告书 第四章环境现状调查与评价 成片状分布,全县各地均发育。小水量区:全县分布面积 549.3km2,占全县总 面积的 37.3%。主要分布在汲冢南部,新蔡河以南、双楼东南、吴台周围、清 水河以南、南丰周围地区。郸城县集聚区属于中等水量区。 全县浅层地下水资源多年平均总量为 3.07 亿 m3。丰水年浅层地下水总量为 4.39 亿 m3,平水年为 2.83 亿 m3,枯水年为 1.77 亿 m3。据《周口地区水利志》 数据,全县农业、工业和生活利用地下水量分别为 1896.0 万 m3、442.3 万 m3、 2723.0 万 m3,合 5061.3 万 m3,占全年县总用水量的 80%以上。 4.1.3.3 地下水的补给、径流、排泄条件 郸城县地下水埋深浅,便于开采,利用量比较大,潜水埋深 6-18m,含水 层为细砂层和粉砂层,地下水走向为西北向东南流动。地下水水力坡度平缓, 一般地下水的径流速度比较缓慢。地下水主要由降水下渗形成,其次为河、渠 侧渗及灌溉回归水补给。降水入渗补给:该区地形平坦,由于区内包气带岩性 主要为细砂层、粉砂层,结构疏松,渗透性好,有利于降水直接入渗补给地下 水,故大气降水补给是该区地下水的主要补给源。 地表水体补给:项目区域地表水体有洺河、黑茨河、杨白沟等,地表水纵 横分布,各渠道渠底均高于浅层水位,以自由渗漏方式补给浅层水。 4.1.4 气象特征 本工程位于郸城县高新技术产业开发区,气候属于北暖温带大陆性季风气 候,气候特点是:雨热同期,四季分明。 郸城县属暖温带半湿润性季风气候区,其基本特征是:气候温和,四季分 明,日照充足,雨量充沛,霜期不长。气温、降水、风随季节变化显著。其主 要气象特征见表 4-1。 表 4-1 郸城县主要气象特征一览表 序号 项目 数值 1 多年平均气温 14.6℃ 2 极端最高气温 43.2℃ 3 极端最低气温 -16.7℃ 4 年平均无霜期 223天 94 郸城县人民医院西南院区新建项目环境影响报告书 第四章环境现状调查与评价 5 年平均降水量 754.9mm 6 日最大降水量 141.5mm 7 全年日照时数 2258.6h 8 平均风速 1.7m/s 9 最大风速 20m/s 10 年主导风向 NNE 11 最大积雪厚度 140mm 12 最大冻土厚度 130mm 4.1.5 土壤、动植物 (1)土壤 全县总土壤面积 219.21 万亩,分潮土和风沙土两大类,10 个土属,潮土类 含 7 个土属,占总土壤面积的 97%,风沙土含 3 个土属,占总土壤面积的 3%。 郸城县境内土壤类型为 2 个土类、2 个亚类、7 个土属、23 个土种。2 个土类分 别为:砂礓黑土类、潮土类。其中砂礓黑土类是境内面积最大、分布较广的土 类,面积 127.1 万亩,潮土类面积 93.52 万亩。境内土层深厚,适于农作物的生 长。项目所在区域土壤以砂礓黑土类的灰质老土为主,地质情况良好,土质分 布均匀,地震承载力为 110KN/m2。 (2)植被 郸城县植物资源比较丰富,仅粮、棉、油、烟等作物就有 29 属、240 个品 种。粮食作物主要以小麦、玉米及大豆为主,经济作物以芝麻、花生、油菜为 主。烟草也发展迅速,亩产高、且品质优良;水生植物中的吴台莲藕以节长、 粗壮、味甜著称。野生植物和栽培的药用植物也很多,收获量较大的有荆芥、 生地、薄荷、大青根、王不留、地滑皮等,多达 189 种。 (3)动物 郸城县动物资源主要以家禽为主,大型家畜以黄牛为多,一般为南阳黄牛 及其杂交种。羊均为槐山羊,其板皮称为“槐路皮”是国际市场的畅销货,1978 年被河南省定为山羊生产基地县。据调查,野生动物有燕子、黄鼠狼、猫头鹰、 蝙蝠、青蛙等 82 种。 95 郸城县人民医院西南院区新建项目环境影响报告书 第四章环境现状调查与评价 高新技术产业开发区内主要以农作物为主,以小麦、玉米、红薯等居多, 植物主要为泡桐,动物以家养畜禽为主,还有少量的野生动物,如鸽子、麻雀 等。根据现场初步调查,开发区规划选址范围内无珍稀动植物资源。 4.1.6 生态环境 项目所在地主要为县城生态环境,区域内人类活动频繁,评价区域内没有 自然保护区、风景名胜区和受国家保护的野生动植物种类,主要以农田、村庄 等人工生态环境为主,主要植被为人工栽培的树木。 4.2环境质量现状监测与评价 4.2.1 环境空气质量现状监测与评价 (1)区域环境空气质量达标判定 根据大气功能区划分原则,项目所在区域为二类功能区,环境空气质量应 执行《环境空气质量标准》(GB3095-2012)二级标准。本项目所在区域为二 类功能区,环境空气质量应执行《环境空气质量标准》(GB3095-2012)二级 标准,本次评价收集了 2022 年郸城县环境监测站点的监测数据,监测因子为 SO2、NO2、PM10、PM2.5、CO 及 O3,统计结果如下: 表 4-2 郸城县 2022 年度常规空气污染物监测结果统计表 污染物 年评价指标 现状浓度/ (μg/m3) 标准值/ (μg/m3) 占标率 /% 达标情况 SO2 年平均质量浓度 8.82 60 14.70 达标 NO2 年平均质量浓度 13.44 40 33.60 达标 PM10 年平均质量浓度 71 70 101.43 不达标 PM2.5 年平均质量浓度 40.89 35 116.83 不达标 CO 24小时平均质量浓度 第95百分位数 590 4000 14.75 达标 130.11 160 81.32 达标 O3 日最大8小时平均值 第90百分位数 96 郸城县人民医院西南院区新建项目环境影响报告书 第四章环境现状调查与评价 由上表可知,2022 年郸城县环境空气常规因子中 SO2、NO2 年均浓度、 CO24 小时平均质量浓度第 95 百分位数以及 O3 最大 8 小时平均质量浓度第 90 百分位数均满足《环境空气质量标准》(GB3095-2012)二级标准及其修改单 要求,但 PM2.5、PM10 年均浓度均超标。PM10、PM2.5 超标原因可能为区域工业 的快速发展、能源消耗、机动车使用量的快速增长及采暖季废气污染物排放的 影响导致。 针对郸城县大气环境质量状况,郸城县人民政府目前正在实施《周口市生 态环境保护委员会办公室关于印发<周口市深入打好秋冬重污染天气消除、夏季 臭氧污染防治和柴油货车污染治理攻坚战行动方案>的通知》(周环委办 [2023]10 号)、《周口市生态环境保护委员会办公室关于印发<周口市 2023 年 蓝天保卫战实施方案>的通知》(周环委办[2023]13 号)。郸城县将采取: ① 调整优化产业结构,推动绿色低碳转型发展; ②深入调整能源结构,推进能源 低碳高效利用; ③持续调整交通运输结构,打好柴油货车治理攻坚战; ④优化 调整用地结构,强化面源污染治理; ⑤推进工业企业四项工程,深化大气污染 综合治理; ⑥强化挥发性有机物治理,打好臭氧污染防治攻坚战;⑦强化区域 联防联控,打好重污染天气消除攻坚战。 采取上述措施后, 2023 年全县环境 空气细颗粒物(PM2.5)年平均浓度控制在 46 微克/立方米以下,可吸入颗粒物 (PM10)年平均浓度控制在 78 微克/立方米以下,5-9 月臭氧(O3)日最大 8 小时平均浓度超标率控制在 19%以下,环境空气质量优良天数比例不低于 72%, 重污染天数比例控制在 3.5%以下。 随着《郸城县 2022 年大气污染防治攻坚战实施方案》的实施, 通过控制 扬尘污染、削减燃煤总量、 控制机动车污染和严把燃煤质量等方面的行动, 项 目所在区域环境空气质量将会逐步得到改善。 (2)特征污染物环境空气质量现状调查与评价 本次评价对本次工程涉及的其他特征污染物(H2S、NH3、臭气浓度)进行 了现场监测,检测单位为河南申越检测技术有限公司,监测时间为 2023 年 6 月 97 郸城县人民医院西南院区新建项目环境影响报告书 第四章环境现状调查与评价 9 日~6 月 15 日(监测因子 H2S、NH3、臭气浓度),监测点位为项目厂址及下 风向何老家村,监测结果见下表。 表 4-3 环境空气质量监测数据单位:mg/m3 监测 监测 点位 因子 NH3 厂址 H2S 0.08~0 (mg/m3) .15 1小时平均值 未检出 (mg/m3) (0.001) 1小时平均值 浓度 (无量纲) 下风向 H2S 0.05~0 (mg/m3) .10 1小时平均值 未检出 (mg/m3) (0.001) 1小时平均值 浓度 (无量纲) 单因子指数 超率标 (%) 最大超 标倍 数 0.2mg/m3 0.4~0.75 0 0 0.01mg/m3 / 0 0 / / / / 0.2mg/m3 0.25~0.5 0 0 0.01mg/m3 / 0 0 / / / / <10 1小时平均值 臭气 标准限值 值 1小时平均值 臭气 NH3 何老家 监测时段 实范测围 <10 由以上分析可知,该评价区域内各监测点的 NH3、H2S 能够满足《环境影 响评价技术导则——大气环境(HJ2.2-2018)》附录 D 表 D.1 其他污染物空气 质量浓度参考限值。 4.2.2 水环境质量现状调查与评价 4.2.2.1 地表水环境质量现状评价 本项目废水经院内污水处理设施处理后经市政污水管网进入郸城县第三污 水处理厂进一步处理,郸城县第三污水处理厂出水进入洺河。 根据附件 5 周口市生态环境局郸城分局出具的环评标准函,项目地表水洺 河执行《地表水环境质量标准》(GB3838-2002)V 类标准。根据 HJ2.3-2018 地表水导则要求水环境质量现状优先采用国务院生态环境保护主管部门统一发 98 达标 情况 达 标 达 标 达 标 达 标 达 标 达 标 郸城县人民医院西南院区新建项目环境影响报告书 第四章环境现状调查与评价 布的水环境状态信息,本次评价地表水现状采用洺河杨楼闸地表水责任目标断 面 2022 年常规监测结果进行评价,故地表水现状监测数据引用合理。洺河杨楼 闸地表水责任目标断面监测数据统计分析见表 4-4。 表 4-4 洺河杨楼闸地表水责任目标断面 2022 年常规监测结果单位:mg/L 监测断面 时间 洺河杨楼 年均 闸 值 V类标准 / 化学需氧量 氨氮 总磷 监测值 标准指数 监测值 标准指数 监测值 标准指数 31.02 0.7755 1.09 0.545 0.25 0.625 40 / 2.0 / 0.4 / 由上表可知,2022 年洺河杨楼闸断面化学需氧量、氨氮、总磷浓度能够满 足《地表水环境质量标准》(GB3838-2002)V 类标准。 4.2.2.2 地下水环境质量现状评价 根据前述地下水评价等级判断,本项目为 IV 类项目可不进行地下水评价。 为了解项目区域地下水背景情况,本次环评委托河南申越检测技术有限公司于 2023 年 6 月 14 日~15 日进行地下水监测。连续监测 2 天,每天一次。当地地下 水径流方向为由西北向东南。 (1)监测点位 依据调查评价区水文地质条件、位置和《环境影响评价技术导则地下水环 境》(HJ610-2016)有关地下水环境现状监测的要求,设置 3 个水质监测点位、 6 个水位测点位。 表 4-5 项目周围地下水环境现状监测点位表 名称 编号 1# 水质监测 2# 点位 3 个 3# 水位监测 点位 6 个 位置 监测因子 监测时间和频 次 丁寨社区 pH、氨氮、硝酸盐、亚硝酸盐、挥 (上游) 发性酚、氰化物、砷、汞、六价铬、总 张柿园 硬度、氟化物、镉、铁、锰、溶解性总 连续监测 2 (两侧) 固体、耗氧量、硫酸盐、氯化物、总大 天,每天采样 何老家(村庄北侧 水井)(下游) 1# 丁寨社区 2# 张柿园 3# 何老家(村庄北水 肠菌群、细菌总数、阴离子表面活性 1 次。 剂。Na+、K+、Ca2+、Mg2+、CO32-、 HCO3-、Cl-、SO42井深、地下水水位、水量、水温、监测 井用途 99 连续监测 2 天,每天采样 1次 郸城县人民医院西南院区新建项目环境影响报告书 第四章环境现状调查与评价 井) 4# 西孙庄 5# 卞郭庄 何老家(村庄南侧 6# 水井) (2)监测分析方法 采样分析方法参照《环境监测分析方法》进行,详见下表。 表 4-6 监测分析方法一览表 检测项目 K+ Na+ Ca2+ Mg2+ 检测标准 检测方法 GB/T 11904- 《水质 钾和钠的测定 火焰原子吸 1989 收分光光度法》 GB/T 11904- 《水质 钾和钠的测定 火焰原子吸 1989 收分光光度法》 GB/T 11905- 《水质 钙和镁的测定 原子吸收分 1989 光光度法》 GB/T 11905- 《水质 钙和镁的测定 原子吸收分 1989 光光度法》 检测仪器 检出限 原子吸收分光光 度计 TAS- 0.05mg/L 990AFG 原子吸收分光光 度计 TAS- 0.01mg/L 990AFG 原子吸收分光光 度计 TAS- 0.02mg/L 990AFG 原子吸收分光光 度计 TAS- 0.002mg/L 990AFG 《水和废水监 总碱度 (CO32-、 HCO3-) 测分析方法》 (第四版增补 版) 国家环境 《酸碱指示剂滴定法》 滴定管 / 《水质 无机阴离子的测定 离子色 谱法》 离子色谱仪 CICD100 型 0.018mg/L 《水质 无机阴离子的测定 离子色 离子色谱仪 CIC- 谱法》 D100 型 《水质 pH 值的测定 电极法》 酸度计 PHS-3C 保护总局 (2002 年) SO42- HJ84-2016 Cl- HJ 84-2016 pH HJ 1147-2020 100 0.007mg/L / 郸城县人民医院西南院区新建项目环境影响报告书 水温 GB/T 13195- 《水质 水温的测定 温度计或颠倒 1991 温度计测定法 (温度计法)》 第四章环境现状调查与评价 温度计 《水质 氨氮的测定 纳氏试剂分光 紫外可见分光光 光度法》 度计 T6 新世纪 GB/T 5750.5- 《生活饮用水标准检验方法 无机 紫外可见分光光 (氮) 2006 非金属指标》 度计 T6 新世纪 亚硝酸盐 GB 7493- 《水质 亚硝酸盐氮的测定 分光光 紫外可见分光光 (氮) 1987 度法》 度计 T6 新世纪 氨氮 HJ 535-2009 硝酸盐 / 0.025mg/L 0.5 mg/L 0.003mg/L 《生活饮用水标准检验方法 感官 挥发酚 GB/T 5750.4- 性状和物理指标 (9.1 挥发酚类 4- 紫外可见分光光 2006 氨基安替吡啉三氯甲烷萃取分光光 度计 T6 新世纪 0.002mg/L 度法)》 氰化物 砷 汞 六价铬 总硬度 氟化物 镉 铁 GB/T 5750.52006 HJ 694-2014 HJ 694-2014 GB/T 5750.62006 GB/T 5750.42006 《生活饮用水标准检验方法 无机 非金属指标 (4.1 氰化物 异烟酸吡唑酮分光光度法)》 紫外可见分光光 度计 T6 新世纪 《水质 汞、砷、硒、铋和锑的测 原子荧光光度计 定 原子荧光法》 AFS-8520 《水质 汞、砷、硒、铋和锑的测 原子荧光光度计 定 原子荧光法》 AFS-8520 《生活饮用水标准检验方法 金属 指标 (10.1 铬(六价) 二苯碳酰 二肼分光光度法)》 紫外可见分光光 度计 T6 新世纪 0.002mg/L 0.3μg/L 0.04μg/L 0.004mg/L 《生活饮用水标准检验方法 感官 性状和物理指标 (7.1 总硬度 乙二 滴定管 1.0mg/L 酸度计 PHS-3C 0.05mg/L 胺四乙酸二钠滴定法)》 GB/T 7484- 《水质 氟化物的测定 离子选择电 1987 极法》 GB/T 7475- 《水质 铜、锌、铅、镉的测定 原 1987 子吸收分光光度法》 GB/T 119111989 《水质 铁、锰的测定 火焰原子吸 收分光光度法》 101 原子吸收分光光 度计 TAS990AFG 原子吸收分光光 度计 TAS- 1μg/L 0.03mg/L 郸城县人民医院西南院区新建项目环境影响报告书 第四章环境现状调查与评价 990AFG 锰 GB/T 119111989 溶解性总 GB/T 5750.4- 固体 2006 耗氧量 硫酸盐 氯化物 阴离子表 面活性剂 GB/T 5750.72006 GB/T 5750.5- 《水质 铁、锰的测定 火焰原子吸 收分光光度法》 0.01mg/L 电子天平 FA2004 / 滴定管 0.05mg/L 《生活饮用水标准检验方法 感官 性状和物理指标 (8.1 溶解性总固 体 称量法)》 《生活饮用水标准检验方法 有机 物综合指标 (1.1 耗氧量 酸性高锰 酸钾滴定法)》 《生活饮用水标准检验方法 无机 非金属指标 铬酸钡分光光度法 2006 紫外可见分光光 (热法)》 《生活饮用水标准检验方法 无机 2006 非金属指标 硝酸银容量法》 1.0mg/L 滴定管 《水质 阴离子表面活性剂的测定 紫外可见分光光 亚甲蓝分光光度法》 度计 T6 新世纪 总大肠菌 GB/T 《生活饮用水标准检验方法 微生 电热恒温培养箱 群 5750.12-2006 物指标 滤膜法和多管发酵法》 DH-500 细菌总数 GB/T 5750.12-2006 《生活饮用水标准检验方法 微生 物指标 (1.1 细菌总数 平皿计数 法)》 5mg/L 度计 T6 新世纪 GB/T 5750.5- GB 7494-1987 原子吸收分光光 度计 TAS990AFG 0.05mg/L 电热恒温培养箱 DH-500 (3)地下水监测结果 地下水执行 GB/T14848-2017《地下水质量标准》中Ⅲ类标准。根据单因 子指数的计算公式计算,地下水水质现状评价结果见下表。 表 4-7 地下水水质水位评价结果 检测结果 检测项目 Ⅲ类标准限值 2023.06.14 单位 何老家(北) 丁寨社区 张柿园 K+ / mg/L 0.8 0.56 0.56 Na+ / mg/L 146 145 134 Ca2+ / mg/L 3.83 4.36 4.17 Mg2+ / mg/L 6.75 47.9 47.4 CO32- / mmol/L 未检出 未检出 未检出 102 / / 郸城县人民医院西南院区新建项目环境影响报告书 第四章环境现状调查与评价 HCO3- / mmol/L 5.24 9.78 4.91 Cl- / mg/L 54.6 27.6 134 SO42- / mg/L 17 8.75 43.4 pH 6.5-8.5 无量纲 8.3 8 7.8 水温 / ℃ 20.2 20.1 20.1 氨氮 0.5mg/L mg/L 0.255 0.143 0.029 硝酸盐 (氮) 20mg/L mg/L 2.3 1.2 1.6 亚硝酸盐 (氮) 1mg/L mg/L 未检出 (0.003) 未检出 未检出 挥发酚 0.002mg/L mg/L 未检出 (0.002) 未检出 未检出 氰化物 0.05mg/L mg/L 未检出 (0.002) 未检出 未检出 砷 0.01mg/L μg/L 1.5 0.8 未检出 汞 0.001mg/L μg/L 0.89 0.7 0.44 六价铬 0.05mg/L mg/L 未检出 (0.004) 未检出 未检出 总硬度 450mg/L mg/L 40.5 222 218 氟化物 1mg/L mg/L 0.34 0.28 0.66 镉 0.005mg/L μg/L 未检出 (1μg/L) 未检出 未检出 铁 0.3mg/L mg/L 0.05 未检出 未检出 锰 0.1mg/L mg/L 未检出 (0.01) 未检出 0.02 溶解性总 固体 1000mg/L mg/L 391 551 516 耗氧量 3mg/L mg/L 2.29 2.63 1.43 硫酸盐 250mg/L mg/L 38 19 68 氯化物 250mg/L mg/L 76.3 42.8 151 阴离子表 面活性剂 0.3mg/L mg/L 未检出 (0.05) 未检出 未检出 总大肠菌 群 3CFU/100mL CFU/100mL 未检出 未检出 未检出 细菌总数 100CFU/100mL CFU/mL 36 38 32 井深 / m 30 25 18 水位 / m 7 6 6 经度 115.13826750° 115.13479893° 115.14566840° 纬度 33.62182613° 33.63955631° 33.63288087° 样品状态 无色、无味、 无肉眼可见物 无色、无味、 无肉眼可见物 无色、无味、 无肉眼可见物 103 郸城县人民医院西南院区新建项目环境影响报告书 第四章环境现状调查与评价 续表 4-7 地下水水质水位评价结果 检测结果 2023.06.15 Ⅲ类标准 限值 单位 K+ Na+ Ca2+ Mg2+ CO32HCO3ClSO42pH 水温 氨氮 硝酸盐 (氮) 亚硝酸盐 (氮) / / / / / / / / 6.5-8.5 / 0.5mg/L mg/L mg/L mg/L mg/L mmol/L mmol/L mg/L mg/L 无量纲 ℃ mg/L 何老家(北 侧) 0.89 144 4.07 7.49 未检出 5.29 54.9 16.7 8.2 20.0 0.269 20mg/L mg/L 1.5 1mg/L mg/L 挥发酚 0.002mg/L mg/L 氰化物 0.05mg/L mg/L 砷 汞 六价铬 总硬度 氟化物 0.01mg/L 0.001mg/L 0.05mg/L 450mg/L 1mg/L μg/L μg/L mg/L mg/L mg/L 镉 0.005mg/L μg/L 铁 0.3mg/L mg/L 锰 0.1mg/L 溶解性总 固体 耗氧量 硫酸盐 氯化物 阴离子表 面活性剂 总大肠菌 群 细菌总数 检测项目 丁寨社区 张柿园 0.56 147 3.88 47.7 未检出 9.71 27.5 8.34 7.9 20.1 0.457 0.53 140 3.88 48.2 未检出 5.02 135 44.8 7.8 20.0 0.033 1.9 2.6 未检出 未检出 未检出 未检出 未检出 未检出 0.7 0.62 未检出 225 0.31 未检出 0.46 未检出 220 0.62 未检出 未检出 未检出 未检出 mg/L 1.4 0.84 0.05 41.6 0.39 未检出 (1μg/L) 0.05 未检出 (0.01) 未检出 0.02 1000mg/L mg/L 779 825 893 3mg/L 250mg/L 250mg/L mg/L mg/L mg/L 2.56 23 73.9 1.61 71 148 0.3mg/L mg/L 2.41 42 77.6 未检出 (0.05) 未检出 未检出 3CFU/100 mL 100CFU/1 CFU/100 mL CFU/mL 未检出 未检出 未检出 34 39 33 未检出 (0.003) 未检出 (0.002) 未检出 (0.002) 104 郸城县人民医院西南院区新建项目环境影响报告书 00mL / / 井深 水位 m m 30 7 115.13826750° 33.62182613° 无色、无味、 无肉眼可见物 经度 纬度 样品状态 第四章环境现状调查与评价 25 6 115.13479893° 33.63955631° 无色、无味、无 肉眼可见物 18 6 115.14566840° 33.63288087° 无色、无味、无 肉眼可见物 根据上述监测结果,项目设置的地下水井监测点位各水质监测因子均能满 足地下水Ⅲ类标准要求。 (4)其他点位地下水水位监测结果 其他点位地下水位监测结果见下表。 表 4-8 其他地下水水位监测结果 检测结果 检测项目 2023.06.14 单位 西孙庄 卞郭庄 何老家(南侧) 水温 ℃ 20.2/20.3 20.0/20.1 20.1/20.2 井深 m 16 22 28 水位 m 5 6 6 经度 115.12593479° 115.13191325° 115.14444351° 纬度 33.63927724° 33.62068551° 33.62012293° 4.2.3 声环境现状评价 本项目位于郸城县科技大道北、公园西路西侧地块,对项目厂界四周的昼 夜噪声进行现场调查,根据调查结果对本项目的声环境质量现状进行评价。 4.2.3.1 评价因子 评价因子等效连续 A 声级:LeqdB(A) 4.2.3.2 评价标准 根据前述分析,东厂界执行《声环境质量标准》(GB3096-2008)中 4a 类、 南、西、北厂界执行 1 类。具体标准限值见表 4-9。 表 4-9 类别 声环境质量标准 单位:dB(A) 评价标准/《声环境质量标准》(GB3096-2008) 105 昼间 夜间 郸城县人民医院西南院区新建项目环境影响报告书 第四章环境现状调查与评价 南、西、北厂 1类 55 45 界 东厂界 4a 70 55 4.2.3.3 监测结果分析 根据 2023 年 06 月 14 日-06 月 15 日对项目区厂界四周进行的噪声实测,噪 声监测统计结果见表 4-10。 表 4-10 噪声监测统计结果 单位:dB(A) 检测日期 东厂界 南厂界 西厂界 北厂界 06 月 14 日昼间 55 52 51 52 52 51 06 月 14 日夜间 45 43 42 44 43 42 06 月 15 日昼间 54 51 50 52 51 50 06 月 15 日夜间 44 42 41 43 42 41 达标 达标 标准 达标 昼间 70, 象局 丁寨 昼间 55,夜间 45 夜间 55 达标 郸城县气 达标 达标 达标 由上表可知,项目厂界噪声值可以满足《声环境质量标准》(GB30962008)1 类、4a 标准要求。 4.2.4 小结 4.2.4.1 环境空气质量现状 2022 年郸城县环境空气常规因子中 SO2、NO2 年均浓度、CO24 小时平均质 量浓度第 95 百分位数以及 O3 最大 8 小时平均质量浓度第 90 百分位数均满足 《环境空气质量标准》(GB3095-2012)二级标准及其修改单要求,但 PM2.5、 PM10 年均浓度均超标。PM10、PM2.5 超标原因可能为区域工业的快速发展、能 源消耗、机动车使用量的快速增长及采暖季废气污染物排放的影响导致。随着 《周口市生态环境保护委员会办公室关于印发<周口市 2023 年蓝天保卫战实施 方案>的通知》(周环委办[2023]13 号)、《郸城县 2022 年大气污染防治攻坚 战实施方案》的实施, 通过控制扬尘污染、削减燃煤总量、 控制机动车污染和 严把燃煤质量等方面的行动, 项目所在区域环境空气质量将会逐步得到改善。 106 郸城县人民医院西南院区新建项目环境影响报告书 第四章环境现状调查与评价 本项目特征污染物环境空气质量现状调查采用现场监测数据进行评价,监 测数据表明,项目区 H2S、NH3 均满足《环境影响评价技术导则大气环境》 (HJ2.2-2018)附录 D 要求。 4.2.4.2 水环境质量现状 2022 年洺河杨楼闸断面化学需氧量、氨氮、总磷浓度能够满足《地表水环 境质量标准》(GB3838-2002)V 类标准。 项目设置的地下水井监测点位各水质监测因子均能满足地下水Ⅲ类标准要 求。 4.2.4.3 声环境质量现状 根据现场监测,项目南、西、北厂界噪声值可以满足《声环境质量标准》 (GB3096-2008)1 类标准、东厂界能满足 4a 类标准要求。项目区周边声环境 较好。 107 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 第五章环境影响预测与评价 5.1施工期环境影响分析 施工期主要污染因子有:施工人员生活污水、生产废水(车辆冲洗废水、 混凝土养护废水)、施工扬尘、施工废气(装修废气、机械设备与运输车辆尾 气)、施工噪声、固体废物(土石方、生活垃圾、建筑弃渣)以及水土流失及 生态破坏等。 5.1.1 废气 (1)施工扬尘影响分析 施工产生的扬尘主要集中在土建施工阶段,按起尘的原因可分为风力起尘 和动力起尘,其中风力起尘主要是由于露天堆放的建材(如黄沙、水泥等)及裸 露的施工区表层浮尘由于天气干燥及大风,产生风力扬尘;而动力起尘,主要 是在建材的装卸、搅拌过程中,由于外力而产生的尘粒再悬浮而造成,其中施 工及装卸车辆造成的扬尘最为严重。由于本项目开挖的土方含水率较高,只要 及时运走,在装卸过程中产生的扬尘量极小。土方堆场只要做好防风措施,扬 尘产生量也较小。 为进一步减小施工扬尘对环境的影响,评价要求在施工过程中,应严格按 照《郸城县污染防治攻坚战领导小组办公室关于印发郸城县 2022 年大气、水、 土壤污染防治攻坚战及农业农村污染治理攻坚战实施方案的通知》(郸环攻坚 办〔2022〕7 号)中施工扬尘的相关要求进行,其具体措施如下: 管理措施:建设单位对建筑工程扬尘污染防治管理工作负首要责任,应当 督促施工单位做好扬尘污染防治管理并加强检查;将扬尘防治目标及施工单位 的扬尘防治责任明确写入承发包合同,并督促施工单位严格落实扬尘污染防治 各项措施,施工工地现场设置降尘员岗位,建立降尘员岗位制度。降尘员佩戴 统一标识,实行一岗双责,对工地扬尘治理工作负直接管理责任。 工程措施: 108 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 ①施工围挡:施工现场沿四周连续设置封闭围墙(围挡),围墙(围挡) 必须安全可靠、整洁美观。一般路段高度不低于 2 米,主干道高度不低于 2.5 米等。 ②冲洗设施:施工现场进出口设置冲洗平台、沉淀池、排水沟等车辆冲洗 设施,达到水资源重复循环利用。 ③场地硬化:施工现场应建立洒水清扫保洁制度,设专人负责卫生保洁, 并做好保洁记录。每天对场区道路进行洒水清扫不少于 2 次,当遇到重污染天 气,要相应增加洒水频次,或施工现场配备洒水车辆。 ④覆盖绿化:施工现场建材应码放整齐,废弃建材建渣应及时清运,不能 及时清运的必须进行覆盖,施工现场非作业面裸土必须进行覆盖,超过三个月 以上不使用的堆土应进行绿化。 ⑤渣土运输:施工现场要使用专用渣土运输车辆,防止物料遗撒造成扬尘 污染。车辆驶离工地前,应落实专人进行冲洗管理,将轮胎和车身冲刷干净, 确保出场车辆符合要求,不污染城市道路。同时严禁超载、超速,按交通管理 部门指定的路线及时间运输。 施工期严格落实“八个百分百”,即施工现场 100%标准化围挡、工地砂土 不用时 100%覆盖、工地路面 100%硬化、拆除工程 100%洒水压尘、出工地车 辆 100%冲净车轮车身、施工现场长期裸土 100%覆盖或绿化、施工现场及污染 指数 100%监控、建筑垃圾清运车辆 100%自动化密闭运输。在项目施工期,对 扬尘严格采取上述防治措施后,其浓度可降至 1.0mg/m3,产生的扬尘可得到有 效控制。 (2)施工机械废气及运输车辆废气 施工期间,使用机动车运送原材料、设备和建筑机械等设备的运转,均会 排放一定量的 CO、NOx 以及未完全燃烧的 HC 等,其特点是排放量小,属间 断性排放,加之项目施工场地扩散条件良好,这些废气可得到有效的稀释扩散, 能够达标排放,因此其对环境的影响较小。 109 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 (3)油漆废气 由于不同建设项目装修时的油漆耗量和油漆品牌不相同,因此,该部分废 气的排放对周围环境的影响也较难预测,本报告仅对油漆废气作一般性估算。 根据市场调查,每 100m2 的房屋装修时需耗油漆 10 组左右(包括地板漆、 墙面漆等),每组油漆约 10kg。在油漆过程中约有 10%溶剂挥发形成废气。油 漆废气的主要污染因子为二甲苯和甲苯等有机溶剂类(约 20%),此外还有极少 量的汽油、丁醇、丙酮、乙酸乙酯等有机溶剂,评价要求项目选用环保型油漆、 涂料、胶粘剂等可减小施工期装修时油漆废气对环境的影响。 综上所述,项目施工期将会对项目所在地环境空气质量造成一定影响,但 这些影响随着施工期的结束也会结束。因此,项目施工期不会对项目所在地环 境空气质量造成明显不利影响。 5.1.2 施工废水 施工期废水主要为施工人员的生活污水和施工废水。 (1)施工废水 施工废水主要为车辆冲洗水及混凝土养护废水等。由于施工过程中未知水 量较多,根据类比分析,本项目施工废水产生量为 15m3/d,施工废水主要污染 因子为 SS,SS 浓度可高达 1000mg/L。施工生产废水经沉淀池 20m3 处理后可作 为生产用水用于运输车辆冲洗及场地洒水降尘,不外排。施工期结束后施工期 间产生的废水影响随之消除。 (2)生活污水 临时项目部及施工人员生活区均设置 10m3 隔油池、10m3 化粪池处理食堂 废水、生活污水,污水经处理后通过临时管道排入周边市政污水管网,对区域 水环境的影响不大。 本项目采取上述措施后,对地表水不会造成明显的不良影响。 同时评价要求施工单位加强施工期废水、废渣的收集与管理,严禁废水、 废渣进入项目周边地表水体,对其造成影响。 110 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 5.1.3 噪声 项目施工机械噪声按合成声源源强(声源 1 米处)声级 101.5dB(A)计算,围 墙隔声按 5dB(A)计,则现场施工随距离衰减后的值。 表 5-1 施工期距声源不同距离处的噪声值单位:dB(A) 距离(m) 1 20 30 110 150 200 预测值 96.5 70.0 66.8 55.1 52.6 50.3 根据噪声预测结果,其昼间施工达标距离为距施工机械 20m,夜间施工达 标距离为距施工机械 110m,根据现场踏勘,项目厂界周边 110m 范围内无环境 敏感点。项目昼间施工期满足《建筑施工场界环境噪声排放标准》(GB125232011)标准要求。 为减少项目施工噪声对环境的影响,环评要求: 1)选用低噪声设备和工艺,加强检查、维护和保养机械设备,保持润滑, 紧固各部件,减少运行震动噪声。整体设备应安放稳固,并于地面保持良好接 触,有条件的应使用减振机座,降低噪声。 2)合理布局施工现场,设备运行点应尽量远离已有在用的建筑物,避免 在同一地点安排多台动力机械设备,以避免局部声级过高。 3)合理安排施工时间,严禁夜间施工。施工单位要严格按照《中华人民 共和国环境噪声污染防治办法》中规定的施工时间进行施工,在夜间(22: 00~6:00)、午间(12:00~14:00)禁止从事高噪声(如挖掘、打桩、搅 拌)的作业,中、高考期间严禁施工。因施工工艺需要等原因确需连续施工的, 必须提前 7 日向周围的 单位和居民公告。公告内容应当包括:本次连续施 工起止时间、施工内容、工地负责人及其联系方式、投诉渠道。 4)合理划定运输路线,适当限制大型载重车的车速,尤其进入居民区等 敏感区域时应限速禁鸣;定期对运输车辆维修、养护。 5)加强施工队伍的管理,禁止高声喧哗,避免不必要的噪声发生。 由于本项目施工期较短,加强施工管理后,施工噪声对周围环境的影响可 控制至最低程度,影响随着施工期的结束而结束。 111 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 5.1.4 固体废物 本项目施工期固体废物主要来自于施工期间土石方、施工人员的生活垃圾、 建筑施工的废料和包装材料等。 项目施工期间土石方用于场区回填或用于周边市政工程及房地产项目填方 使用,建筑施工废料(铁质弃料、木材弃料等)分类收集,可利用部分回收利 用,不能利用部分运至指定建筑垃圾填埋场,生活垃圾设置垃圾桶进行收集, 由环卫部门统一清运。可见,项目所产生的固废均去向明确,均无外排,项目 所产生的固废对周围环境影响较小。 5.1.5 生态环境影响分析 项目施工过程涉及地表开挖及回填,将破坏原有地表及地表植被,雨水冲 刷活动将带来水土流失加剧现象,施工过程中加强临时堆放场的管理,制定土 方表面压实、定期喷水、覆盖、设置截排水沟等措施;不需要的泥土,建筑材 料弃渣应及时运走,不宜长时间堆积。 5.1.6 施工期环境管理 施工期根据项目周围环境的特点由施工队制定出一套施工环境管理方案并 制定出合理的施工平面布置,加强管理,文明施工,可以有效控制施工期噪声 污染、大气污染和水污染,使施工期对周围环境带来的不便和污染降到最低。 综上所述,项目施工期间,对环境存在一定的影响,但是只要施工方严格 按照施工规范文明施工,采取适当的防尘、降噪和废水治理措施等,可以将影 响减少到最小。施工结束后,以上影响可消除。 5.2营运期环境影响分析 5.2.1 地表水环境影响分析 (1)废水产生量及废水水质状况 本项目建成后项目总排水量为 609.24m3/d,包括 588.99m3/d 医疗废水和 20.25m3/d 清排水。 112 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 进入污水站的医院污水排水量为 588.99m3/d。项目废水水质为 pH6-9、 COD350mg/L、BOD5150mg/L、NH3-N50mg/L、SS200mg/L、动植物油 4.0mg/L、 LAS100mg/L、粪大肠菌群数 3.0×108MPN/L、LAS100mg/L。经臭氧 30min 预消 毒后,进入医院污水处理站的医疗废水已基本不存在肠道致病菌、肠道病毒、 结核杆菌。 清排水包括消毒蒸汽用的纯水制备浓水、非病区空调冷凝水,排水量分别 为 7008m3/a 、 126m3/a , 合 计 20.25m3/d 。 消 毒 蒸 汽 用 的 纯水 制 备 浓 水 污 染 物 COD35mg/L,全盐类 3500mg/L。空调冷凝水为空气中水分冷凝形成不考虑全 盐类,COD 浓度 35mg/L。 本项目排水实行雨污分流、污污分流。雨水直接排入市政雨水管网。病区 食堂废水经油水分离器处理、病区化验室废水经酸碱中和处理后经过臭氧预消 毒,然后与化粪池+臭氧预消毒处理过的病区其他医疗废水(门诊废水、 住院 病房废水、 医务人员废水、空调冷凝水、蒸汽消毒废水)、隔油预处理过的非 病区普通食堂废水、普通化粪池处理过的非病区其他生活污水(后勤办公人员 废水、宿舍楼、空调冷凝水)一起排入医院综合污水处理站进一步处理达标后, 汇入郸城县第三污水处理厂,尾水排入洺河。消毒蒸汽纯水制备浓水和非病区 空调冷凝水作为清排水直接排入医院总排口。 本项目综合废水经污水处理设施处理后通过市政污水管网进入郸城县第三 污水处理厂进一步处理,根据《医院污水处理工程技术规范》(HJ2029-2013), 本次评价确定废水处理工艺采用“预消毒+格栅+调节池+水解酸化+接触氧化 +MBR 膜池+次氯酸钠消毒+脱氯池”处理工艺。经处理后医院总排污口出水浓度 COD56.0mg/L 、 BOD517.0mg/L 、 SS18.6mg/L 、 NH3-N13.9mg/L 、 动 植 物 油 3.9mg/L、粪大肠菌群数 87.1MPN/L、LAS4.8mg/L、肠道致病菌及肠道病毒、 结核杆菌不得检出。项目综合废水经院内地下污水处理站(设计处理能力 710m3/d)处理后,水质达到《医疗机构水污染排放标准》(GB18466-2005)表 113 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 1 传染病、结核病医疗机构水污染物排放浓度、最高允许排放负荷标准要求要 求和郸城县第三污水处理厂进水水质要求。 本项目产生的废水经地下污水处理站处理后,经市政管网引入郸城县第三 污水处理厂进一步处理,达到《城镇污水处理厂污染物排放标准》(GB18918— 2002)中一级标准 A 标准及《周口市 2019 年水污染防治攻坚战实施方案》及中 共河南省委、河南省人民政府发布的《加强生态环境保护打好污染防治攻坚战 责任书》(2018-2020)及《地表水环境质量标准》(GB3838-2002))IV 类标 准后,进入洺河。 (2)污水处理厂接纳项目外排废水的可行性 1)收水范围及周边污水管网调查 郸城县第三污水处理厂占地面积 57440.35 平方米,建设工程总设计规模为 4 万 m³/d,分两期建设。一期工程已于 2022 年 4 月通过自主验收。一期工程 建设规模为 2 万 m³/d,主要对郸城县新城区(北至洺河、南至皇姑河、西至公 园西路、东至府东路)及汲冢镇的生活污水进行收集处理。项目污水处理二级 采用“水解酸化+AAO 生化处理”工艺,深度处理采用“磁混凝沉淀池+深床 滤池+紫外线消毒”工艺,污泥采用“重力浓缩+板框压滤”工艺脱水干化。郸 城县第三污水处理厂处理后水质执行《城镇污水处理厂污染物排放标准》 (GB18918—2002)中一级标准 A 标准,同时满足《周口市 2019 年水污染防治攻 坚战实施方案》及中共河南省委、河南省人民政府发布的《加强生态环境保护 打好污染防治攻坚战责任书》(2018-2020)中的《地表水环境质量标准》 (GB3838-2002))IV 类标准后,进入洺河。 根据前述分析,根据郸城县第三污水处理厂的收水范围为郸城县新城区 (北至洺河、南至皇姑河、西至公园西路、东至府东路)及汲冢镇的生活污水, 本项目医院东侧紧临公园东路,本项目位于郸城县第三污水处理厂收水范围内。 郸城县第三污水处理厂位于周口市郸城县郸淮公路与公园西路交汇处以西, 本项目医院东侧紧临公园东路,项目医院与郸城县第三污水处理厂的位置关系 114 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 及排水路径见附图 17,可见本项目与郸城县第三污水处理厂均位于公园西路西 侧不远(直线距离 3.42 公里),项目位于郸城县第三污水处理厂收水范围内, 项目医院污水处理达标后排入公园西路污水管网,然后沿公园西路向北 3.55 公 路折向西侧污水厂进厂路,汇入郸城县第三污水处理厂处理。 根据现场调查,郸城县第三 污水处理厂一期工程已于 2022 年 4 月自主验 收,污水厂现正常运行,污水厂进厂路和公园西路配套的污水管网均已敷设完 善,正常运行。本项目医疗废水处理达标后可经公园西路已敷设的市政污水管 网排入郸城县第三污水处理厂进一步处理。因此从排水路径上分析,本项目废 水排入郸城县第三污水处理厂进一步处理可行。 2)从水量上分析 郸城县第三污水处理厂工程设计污水日处理 2.0 万吨规模,根据调查,目 前污水处理厂收水量为 6080m3/d,剩余处理能力 13920m3/d。 本项目总排水量为 609.24m3/d,约占郸城县第三污水厂剩余处理能力的 4.38%,完全可以接纳本项目产生的废水。本项目废水可进入郸城县第三污水 处理厂进行处理。从水量分析,项目排入郸城县第三污水处理厂进一步处理可 行。 3)从水质上分析 从水质上来说,本项目排水水质和郸城县第三污水处理厂进水水质对比见 表 5-2。 表 5-2 COD 项目 本项目排水水质和郸城县第三污水处理厂进水水质比较一览表 BOD5 SS 氨氮 (mg/L (mg/L (mg/L (mg/ ) ) ) L) 500 200 300 35 动植物 粪大肠 油 菌群 (mg/L (MPN/ ) L) / / LAS (mg/ L) 肠道致 肠道病 结核杆 病菌 毒 菌 (MPN/ (MPN/ (MPN/ L) L) L) / / / 全盐类 (mg/L ) 郸城县第 三污水处 理厂进水 水质 115 / / 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 GB184662005 《医疗机 构水污染 物排放标 准》表1传 不得检 不得检 不得检 60 20 20 15 5 100 5 56.0 17.0 18.6 13.9 3.9 87.1 4.8 出 染病、结 出 / 出 核病医疗 机构水污 染物排放 标准 本项目总 不得检 不得检 不得检 出 排口水质 出 出 111.0 由表 5-2 可以看出,而本项目外排水质可以满足郸城县第三污水处理厂进 水水质要求,同时满足《医疗机构水污染物排放标准》表 1 处理排放标准,同 时也完全可以满足郸城县第三污水处理厂的进水要求。 综上分析,本项目外排废水进入郸城县第三污水处理厂是可行的。 本项目废水间接排放口情况见表 5-3。 表 5-3 项目废水类别、污染物及污染治理设施信息一览表 污染治理设施 排放口情况 排 废水 污染物 排放 排放规 污染治 污染 污染治 放 类别 种类 去向 理设施 治理 理设施 口 编号 工艺 编 律 设施 号 病区医疗废水(化验 COD、 间断排 室废水、门诊废水、 BOD5、SS、 放,排 住院病房废水、 医 氨氮、动植物 放期间 务人员废水、空调冷 油、阴离子表 市政 流量不 凝水、蒸汽消毒废 面活性剂、粪 污水 稳 水、食堂废水)、非 大肠菌群数、 道 定且无 病区废水(后勤办公 肠道致病菌、 规 人员废水、宿舍楼、 肠道病毒、结 律,但 空调冷凝水) 核杆菌 不属于 116 排放 口设 置是 否符 合要 求 排 放 口 类 型 预处理+格 栅+调节池+ TW00 1 污水 处 理站 水解酸化+ D 接触氧化 W +MBR膜池 0 +次氯酸钠 01 消毒+脱氯 池 企 是 业 总 排 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 冲击性 排放 本项目废水间接排放口情况见表5-4。 表 5-4 项目废水间接排放口情况一览表 排放口地理坐标/o 排放 口编 号 DW00 1 经度 纬度 115.1459 33.62853141 1657 受纳污水厂信息 国家或地方 排放 污染物种 污染物排放 去向 名称 类 浓度限值 (mg/L) 公园西 COD 30 郸城县第三污 路污水 水处理厂 NH3-N 1.5 管网 废水排放 量/(吨/ 年) 220976.1 本项目废水间接排放口情况见下表。 表 5-5 国家或地方污染物排放标准及其他按规定商定的排放协议 排放口编 号 名称 污染物种类 浓度限值(mg/L) COD 60mg/L,最高允许排放负荷60g/床位﹒d BOD5 20mg/L,最高允许排放负荷20g/床位﹒d SS 20mg/L,最高允许排放负荷20g/床位﹒d NH3-N 15mg/L 动植物油 5mg/L 粪大肠菌群 100MPN/N 肠道致病菌 不得检出 肠道病毒 不得检出 结核杆菌 不得检出 COD 500 郸城县第三污水处理 BOD5 200 厂进水水质要求 NH3-N 35 SS 300 GB18466-2005《医疗 机构水污染物排放标 准》表1传染病、结核 病医疗机构水污染物 DW001 项目废水污染物排放执行标准一览表 排放浓度、最高允许 排放负荷标准要求 5.2.2 地下水环境影响分析 根据地下水环境影响评价工作分级划分原则,新建医院类报告书项目,三 甲类为Ⅲ类,其余为Ⅳ类项目。根据项目可研项目为三级医院,本次环评按三 级医院评定,IV 类项目。根据《地下水环境敏感程度分级表》,IV 类项目可不 进行地下水评价。 117 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 5.2.3 环境空气影响分析 本工程产生的废气主要为含菌废气、检验废气、食堂油烟和汽车尾气、生 活垃圾收集站恶臭及地下污水处理站产生的恶臭、备用发电机燃烧废气。 5.2.3.1 含菌废气 本项目医疗区通风废气及病房楼可能含传染性的细菌和病毒,本项目拟通 过紫外灯照射的方式消毒,以减轻对环境的影响。基于病毒致病机理、条件等 差异,对项目产生含菌气体可能对周围环境的影响很难作准确的定量分析,本 评价根据医院室内空气消毒的要求对本项目产生的含细菌废气对周围环境的影 响进行分析。 本项目病区含菌废气采用紫外线杀毒后经专用排风烟道引至楼顶排放;手 术室、负压病房采用全新风直流式空调系统,送风应经过初效、中效、高效过 滤器三级处理,排风经过高效过滤器过滤处理后经过专用排风烟道引至楼顶排 放,可以减轻含菌废气对环境的影响,使各科室内细菌总数符合《室内空气中 细 菌 总 数 卫 生 标 准 》 (GB/T17093-1997) 室 内 空 气 中 细 菌 总 数 规 定 撞 击 法 ≤ 4000cfu/m3 规定;可知经消毒后,医院内各类环境空气的细菌总数均低于室内 空气卫生标准,含菌气体经消毒后在室外经扩散和稀释后对最近居民区基本无 影响。 5.2.3.2 检验废气 本项目在检验过程中使用少量有机试剂等,这 些物质具有一定的挥发性, 日常封闭储存,使用时会产生少量的酸性废气及挥发性有机 废气等。该部分废 气的挥发量很少,检验过程均采用全自动分析设备,只需将药剂和样品放进设备内, 即可自动进行化验得出结果,整个过程均由密闭的设备进行,检验室内设有安全柜, 检验废气经安全柜自带的高效空气过滤器处理后 可去除致病细菌、生物气溶胶及其他 污染物有害气体,再引至楼顶排放,排气中的致病细菌及生物气溶胶可被除去,减轻 对环境和周围环境的影响,同时医院做好检验室内的消毒卫生工作,确保检验废气处 理后不会对周围环境造成明显影响。高效过滤器过滤原理是采用了活性炭的吸附作用, 118 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 不仅可以去除粉尘、烟雾和有机、无机污染物,还可以在空气中去除异味和有害气体。 参考《医院消毒卫生标准》(GB15982-2012),高效空气过滤器是可行的含菌废气消毒 措施。 5.2.3.3 食堂油烟废气 根据工程分析,本项目后勤办公综合楼食堂油烟废气、门诊医技综合楼食 堂油烟废气经高效静电式油烟净化器处理后。 本项目后勤办公综合楼食堂油烟废气经高效静电式油烟净化器处理后,项 目建成后油烟总排放量为 0.00329t/a、0.0015kg/h,排放浓度为 0.375mg/m3,非 甲烷总烃总烃排放量为 0.00330t/a、0.0015kg/h,排放浓度为 0.377mg/m3。满足 河南省地方标准《餐饮业油烟污染物排放标准》(DB41/1604-2018)(油烟 1.0mg/m3,非甲烷总烃 10.0mg/m3),由专用排烟通道引至后勤办公综合楼楼 顶排放。 门诊医技综合楼食堂油烟废气经高效静电式油烟净化器处理后,项目建成 后油烟总排放量为 0.0274t/a、0.0125kg/h,排放浓度为 0.521mg/m3,非甲烷总 烃总烃排放量为 0.0275t/a、0.0126kg/h ,排放浓度为 0.524mg/m3。满足河南省 地方标准《餐饮业油烟污染物排放标准》(DB41/1604-2018)(油烟 1.0mg/m3, 非甲烷总烃 10.0mg/m3),由专用排烟通道引至门诊医技综合楼楼顶排放。 5.2.3.4 汽车尾气 本项目地下车库安装抽排风系统,因此本项目产生的汽车尾气对周围环境 影响较小。 5.2.3.5 生活垃圾收集站恶臭 该项目设专门的垃圾收集站房,院区的生活垃圾由密闭式塑料垃圾桶收集 大生活垃圾收集点,每天由环卫部门集中清运处理,生活垃圾收集站不进行垃 圾处理、无压缩工艺。在生活垃圾的收集、转运过程中,部分易腐败的有机垃 圾由于分解会释放出异味,对环境的影响主要表现为恶臭,其主要成分是 H2S、 NH3。 119 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 垃圾恶臭气体是多组分、低浓度化学物质形成的混合物,污染物成分复杂, 成分和含量均较难确定,目前尚无垃圾收集点恶臭气体产生量的计算方法,根 据经验,垃圾桶产生的恶臭很轻微,对环境无明显影响。 评价要求采取的措施:垃圾袋装化,可有效防止生活垃圾收集站)H2S 和 NH3 等恶臭污染物散发,必要时使用除臭剂;尽量减少垃圾暴露时间,及时清 运,日产日清,夏季增加清运次数。 5.2.3.6 地下污水处理站产生的恶臭 本项目地下污水处理站在运行过程中由于微生物、原生动物、菌股团等生 物的新陈代谢会产生少量的恶臭气体,其主要成分为臭气浓度、H2S、NH3 等。 本项目地下污水处理站采用封闭式设置,各构筑物池顶均加盖封闭,盖板上预 留进、出气口,出气口设置排气管道,产生的恶臭经风机引至恶臭气体处理设 施处理;污泥脱水间封闭,采用引风机将废气引入废气处理设施处理,废气处 理设施采用“负压收集+生物除臭+紫外线消毒+经管道引至附近病房楼楼顶排放 (20m 高)”的处理工艺,处理后满足《恶臭污染物排放标准》(GB14554-93)表 2 标准(臭气浓度 2000、H2S0.58kg/h、NH38.7kg/h)。 为减少地下污水处理站恶臭对院区及周边环境的影响,建设单位拟将处理 后的恶臭气体经管道引至病房楼楼顶排放(约 20m),排放口不对着门诊去和 医疗区、病房区,对医院和周围敏感点影响较小,故项目恶臭措施设置合理。 5.2.3.7 备用发电机燃烧废气 本项目配备有 1 台柴油发电机组,其排放的燃油废气中主要包含 CO、 NOx 等污染物。备用发电机在供电正常时不使用,只有在停电情况下才会使用, 发电时间短,全年使用时间少,废气排放量少,采用轻质柴油作为燃料,污染 物排放量极少,故不再进行定量分析。发电机废气经过自带的净化装罝处理后, 通过专用烟道引至楼顶排放。 5.2.3.8 评价工作等级及评价范围确定 (1)污染源参数确定 120 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 根据工程分析有关内容,本项目废气污染源排放情况见下表。 表 5-6 正常工况有组织废气污染源计算参数一览表 排气筒底部中心坐 标/m 年 排气 筒底 名称 部海 经度° 纬度° 拔/m 排气 直 烟气 烟气 筒高 径 流速 温度 度/m /m /(m/s) /℃ 排 排 小 工 时 况 数/h 污水处理 站恶臭排 气筒 E115.22096 N33.628 5200 392907 42 20 0.2 14.6 25 污染物排放速率 放 放 876 正 0 常 污染物 kg/h g/s H2S 0.0001 0.00003 NH3 0.0030 0.00083 表 5-7 非正常工况点源参数取值一览表 排气筒底部中心坐 标/m 年 排气 筒底 名称 经度° 排气 直 筒高 径 烟气 流速 烟气 温度 排 排 污染物排放速率 放 放 部海 /(m/s 小 工 纬度° 拔/m 度/m /m ) /℃ 时 况 污染物 kg/h 数/h 污水处理 站恶臭排 气筒 E115.14349 N33.628 835 49696 42 20 0.2 14.6 25 876 正 0 常 g/s H2S 0.0004 0.00011 NH3 0.010 0.00278 (2)评价标准 本次对环境质量进行评价时标准值见表 5-8。 表 5-8 评价因子 标准(μg/m3) H2S 10 NH3 200 评价标准 标准名称 《环境影响评价技术导则大气环境》 (HJ2.2-2018)附录D 中H2S的1h平均浓度 《环境影响评价技术导则大气环境》 (HJ2.2-2018)附录D 中NH3的1h平均浓度 (3)预测结果 本项目采用估算模式预测其对周围环境的影响如下: 表 5-9 项目有组织排放恶臭废气估算模式计算结果一览表 121 郸城县人民医院西南院区新建项目环境影响报告书 距源中心下风向 第五章环境影响预测与评价 H2S NH3 下风向预测浓度 浓度占标率 下风向预测浓 浓度占标率 Ci(μg/m3) Pi 度Ci(μg/m3) Pi 50 0.01329 0.13% 0.23866 0.12% 100 0.01635 0.17% 0.29429 0.15% 200 0.01527 0.15% 0.27481 0.14% 300 0.01329 0.13% 0.23866 0.12% 400 0.0105 0.11% 0.18871 0.09% 500 0.00849 0.08% 0.15272 0.08% 600 0.00804 0.08% 0.14440 0.07% 700 0.00771 0.08% 0.13874 0.07% 800 0.00726 0.07% 0.13041 0.07% 900 0.00678 0.07% 0.12209 0.06% 1000 0.00633 0.06% 0.11376 0.06% 1200 0.0057 0.06% 0.10275 0.05% 1400 0.00525 0.05% 0.09442 0.05% 1600 0.00477 0.05% 0.08609 0.05% 1800 0.00432 0.04% 0.07777 0.03% 2000 0.00402 0.04% 0.07213 0.03% 2500 0.00339 0.03% 0.06112 0.03% 3000 0.00294 0.03% 0.05280 0.02% 3500 0.00264 0.03% 0.04714 0.02% 4000 0.00264 0.03% 0.04714 0.02% 4500 0.00246 0.02% 0.04446 0.02% 5000 0.00231 0.02% 0.04165 0.02% 下风向最大浓度 0.01776 0.18% 0.31925 0.16% 77 77 77 77 / / / / 距离D(m) 下风向最大浓度 出现距离 D10%最远距离 表 5-10 非正常工况下全院有组织排放预测结果一览表 H2S 距源中心下风向 距离D(m) NH3 下风向预测浓度 浓度占标率 下风向预测浓 浓度占标率 Ci(μg/m3) Pi 度Ci(μg/m3) Pi 50 0.04873 0.48% 0.79938 0.40% 100 0.05995 0.61% 0.98572 0.49% 200 0.05599 0.56% 0.92043 0.46% 300 0.04873 0.48% 0.79938 0.40% 122 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 400 0.03850 0.39% 0.63207 0.32% 500 0.03113 0.30% 0.51152 0.25% 600 0.02948 0.30% 0.48364 0.25% 700 0.02827 0.29% 0.46468 0.24% 800 0.02662 0.26% 0.43680 0.22% 900 0.02486 0.25% 0.40891 0.20% 1000 0.02321 0.23% 0.38102 0.19% 1200 0.02090 0.21% 0.34413 0.16% 1400 0.01925 0.19% 0.31625 0.16% 1600 0.01749 0.18% 0.28837 0.14% 1800 0.01584 0.15% 0.26047 0.13% 2000 0.01474 0.14% 0.24161 0.12% 2500 0.01243 0.12% 0.20471 0.11% 3000 0.01078 0.11% 0.17682 0.08% 3500 0.00968 0.10% 0.15787 0.07% 4000 0.00968 0.10% 0.15787 0.07% 4500 0.00902 0.08% 0.14894 0.07% 5000 0.00847 0.08% 0.13951 0.07% 下风向最大浓度 0.06512 0.65% 1.06929 0.53% 下风向最大浓度 77 77 77 77 / / / / 出现距离 D10%最远距离 由 ARESCREEN 估算模式浓度预测结果可知: 正常工况下,地下污水处理站恶臭硫化氢的最大落地浓度占标率为 0.18%, 最大落地浓度 0.01776μg/m3,出现的距离为污水处理站恶臭排气筒下风向 77m 处。氨的最大地面浓度占标率为 0.16%,最大落地浓度 0.31925μg/m3,出现的 距离为污水处理站恶臭排气筒下风向 77m 处。厂界恶臭污染物排放浓度能够满 足 《 恶 臭 污 染 物 排 放 标 准 》 (GB14554-93) 表 2 标 准 ( H2S0.06mg/m3 、 NH31.5mg/m3),污水处理站周边恶臭污染物排放浓度可以满足《医疗机构水 污染物排放标准》(GB18466-2005)表 3 污水处理站周边大气污染物最高允许 浓度(NH31.0mg/m3 、H2S0.03mg/m3 )。估算模式已考虑到各种不利气象的组 合情况,分析结果表明,本项目对大气环境的影响较小。 123 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 由上表可知,非正常工况下,NH3 最大占标率为 0.53%、H2S 最大占标率为 0.65%,与正常工况相比,污水处理站恶臭排气筒出口污染物对周围环境影响相 对较大,建议企业应加强日常管理,保证环保措施正常进行,完善事故应急预 案,使其对周边环境的影响降到最低。 (4)恶臭气体对周围环境敏感点的影响预测 表 5-11 项目实施后周边敏感点影响预测结果一览表 污染因 子 预测点 名称 丁寨 张柿园 何老家 郸城县气象局 (178m) (254m) (350m) (144m) 0.27910 0.25529 0.21369 0.28572 0.14% 0.13% 0.11% 0.14% 浓度值 氨气 (ug/m3) 占标率 200 标准(ug/m3) 浓度值 硫化氢 (ug/m3) 占标率 0.01551 0.01420 0.01190 0.01587 0.16% 0.14% 0.12% 0.16% 10 标准(ug/m3) (4)评价工作等级 依据《环境影响评价技术导则 大气环境》(HJ2.2-2018),根据项 目的初步工程分析结果,分别计算项目排放主要污染物的最大地面空气质量浓 度占标率 Pi(第个污染物)及第 i 个污染物的地面空气质量浓度达标准限值 10%时所对应的最远距离 D10%。其中 Pi 定义为: Pi=Ci/C0i×100% (5-1) 式中:Pi—第 i 个污染物最大地面空气质量浓度占标率,%; Ci——采用估算计算出的第 i 个污染物最大 1h 地面空气质量浓度,μg/m3; Coi——第 i 个污染物的环境空气质量标准,μg/m3; 评价工作等级按表 5-12 的分级判据进行划分。最大地面浓度占标率 Pi 按公 式(5-1)计算,如污染物数 i 大于 1,取 P 值中最大者(Pmax)。 表 5-12 评价工作等级 评价工作等级 评价工作等级判据 一级 Pmax≥10% 124 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 二级 1%≤Pmax<10% 三级 Pmax<1% 本次评价各污染物预测结果见表5-13。 表 5-13 大气环境影响评价等级计算结果 最大地面浓度 污染源 污染物名称 出现的 最大地面浓 最大占 下风向距离 度(μg/m3) 标率% 评价等级 (m) 污水处理站 除臭系统排 气筒 H2S 77 0.01776 0.18% 三级 NH3 77 0.31925 0.16% 三级 根据《环境影响评价技术导则大气环境》(HJ2.2-2018),本项目大气环 境评价设定为三级,根据《环境影响评价技术导则 大 气 环 境 》 ( HJ2.2- 2018)的规定,本项目不进行进一步预测与评价,只对污染物排放量进行核算。 (5)大气环境防护距离 根据《环境影响评价技术导则 大气环境》(HJ2.2-2018)要求,对于项目 厂界浓度满足大气污染物厂界浓度限值,但厂界外大气污染物短期贡献浓度超 过环境质量浓度限值的,可以自厂界向外设置一定范围的大气环境防护区域, 以确保大气环境防护区域外的污染物贡献浓度满足环境质量标准。从厂界起所 有超过环境质量短期浓度标准值的网格区域,以自厂界起至超标区域的最远垂 直距离作为大气环境防护距离。 对于本项目,项目厂界浓度满足大气污染物厂界浓度限值,并且厂界外大 气污染物短期贡献浓度均未超过环境质量浓度限值,故本项目不设置大气环境 防护距离。 (6)项目污染物年排放量核算 项目污染物年排放量见下表。 表 5-14 污染源排放核算表 序号 全院 污染物 核算年排放量(t/a) 有组织 无组织 合计 H2S 0.0010 / 0.0010 NH3 0.0263 / 0.0263 125 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 5.2.4 声环境影响分析 5.2.4.1 评价等级及范围 根据《环境影响评价技术导则声环境》(HJ2.4-2021),所处的声环境功 能区为 GB3096 规定的 2 类地区,或建设项目建设前后评价范围内敏感目标噪 声级增高量在 3~5dB(A)以下[含 5dB(A)],或受噪声影响人口数量增加较多时, 按二级评价。本项目所在区域属于 1 类区,因此确定本项目声环境评价等级为 二级,评价范围为四周厂界外 200m。评价范围内声环境保护目标情况见表 2-8。 5.2.4.2 主要噪声源强 根据建设项目工程布局及其建设内容,项目区主要声源发生在中央空调风 冷热泵机组、污水站水泵及风机、液氧站空压机等,源强 85-90dB,具体源强 及采取防治措施后的噪声值详见表 5-15。 表 5-15 本项目室外主要噪声源及防噪措施统计表 坐标/m 工段 声源名称 型号 声源源强 声压级 X Y Z dB (A) 距声源 声源控制措施 距离/m 门诊医技综合楼 中央空调风冷热 设于楼顶、隔 / -75 70 46 90 1 泵机组 呼吸道楼中央空 制冷供 暖 调风冷热泵机组 发热门诊中央空 调风冷热泵机组 食堂 食堂风机 门诊医技综合楼 食堂风机 24h运行 设于楼顶、隔 / 48 0 27 90 1 声罩隔声、消 24h运行 声、减振 设于楼顶、隔 / 0 78 12 90 1 声罩隔声、消 24h运行 声、减振 设于楼顶、隔 / -88 45 18 90 1 泵机组 后勤办公综合楼 声罩隔声、消 声、减振 后勤办公综合楼 中央空调风冷热 运行时段 声罩隔声、消 24h运行 声、减振 / -68 48 6 85 1 / 133 113 20 85 1 126 隔声罩隔声、 消声、减振 隔声罩隔声、 消声、减振 8h运行 8h运行 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 表 5-16 室内噪声源情况一览表 空间相 声源源强 建 /m 声 筑 物 名 源 型 声压 名 号 级 /dB 称 称 对位置 (A ) 距 声 源 室 建筑外噪 内 声 距室 边 降噪措 内边 界 运行 插入损 声 建 施 界距 声 时段 失/dB 压 筑 Z 离/m 级 (A 级 外 /dB /dB 距 (A (A 离 25 50 1m 25 50 1m 25 50 1m X Y 距 离 /m 建筑物 地下、 水 水 泵 泵 房 / 85 1 构筑物 隔声、 0 3 - 0 2 1 75 1 75 1 75 24h 运行 减振 地下、 污 风 水 机 站 减振、 85 1 构筑物 隔声、 消声 液 空 氧 压 站 机 85 1 1 1 5 构筑物 - 隔声、 1 减振、 1 消声 8 6 9 2 1 1 7 24h 运行 24h 运行 5.2.4.3 预测范围 本工程噪声预测范围为厂区四周厂界和周围环境敏感点。 5.2.4.4 预测方法 采用《环境影响评价技术导则 声环境》(HJ2.4-2021)导则中推荐模式进 行预测,模式如下: 1、室内声源等效室外声源声功率级模型 声源位于室内,室内声源可采用等效室外声源声功率级法进行计算。设靠 近开口处(或窗户)室内、室外某倍频带的声压级或 A 声级分别为 Lp1 和 Lp2。 若声源所在室内声场为近似扩散声场,则室外的倍频带声压级可按下式近似求 出: 127 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 Lp2=Lp1-(TL+6) 式中:Lp1——靠近开口处(或窗户)室内某倍频带的声压级或 A 声级, dB; Lp2——靠近开口处(或窗户)室外某倍频带的声压级或 A 声级,dB; TL——隔墙(或窗户)倍频带或 A 声级的隔声量,dB。 2、户外声传播的衰减模型 (1)室外声源在预测点的声压级计算 户外声传播衰减包括几何发散(Adiv)、大气吸收(Aatm)、地面效应 (Agr)、屏障屏蔽(Abar)、其他多方面效应(Amisc)引起的衰减。根据声 源声功率级或靠近声源某一参考位置处的已知声级(如实测得到的)、户外声 传播衰减,计算距离声源较远处的预测点的声级,用下式计算: Lp(r)=Lp(ro)+DC–(Adiv+Abar+Aatm+Agr+Amisc) 式中: Lp(r)—距声源 r 处的 A 声级,dB(A); Lp(ro)—参考位置 ro 处 A 声级,dB(A); DC—指向性校正,它描述点声源的等效连续声压级与产生声功率级 Lw 的 全向点声源在规定方向的声级的偏差程度,dB;指向性矫正等于点声源的指向 性指数 DI 加上计算到小于 4π球面度(sr)立体角内的声传播指数 DΩ,对辐 射到自由空间的全向点声源,DC 取 0dB; Adiv—几何发散衰减量,dB(A); Abar—遮挡物引起的声级衰减量,dB(A); Aatm—空气吸收引起的声级衰减量,dB(A); Agr—地面效应衰减,dB(A); Amisc—其它多方面原因衰减,dB(A)。 (2)衰减量计算 1)空气吸收引起的 A 声级衰减量按下式计算: 128 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 Aatm=a(r-ro)/1000 式中: a 为每 1000m 空气吸收系数,是温度、湿度和声波频率的函数。本项目设 备噪声以中低频为主,空气衰减系数很小,本评价由于计算距离较近,Aatm 计 算值较小,故在计算时忽略此项。 2)遮挡物引起的衰减量 Abar 位于声源和预测点之间的实体障碍物,如围墙、建筑物、土坡、地堑或绿 化林带都能起声屏障作用,从而引起声能量的衰减,具体衰减根据不同声级的 传播途径而定,一般取 0~10dB(A)。 3)点声源的几何发散衰减(Adiv) 无指向性点声源几何发散衰减的基本公式是: Lp(r)=Lp(r0)-20lg(r/r0) 公式中第二项表示了点声源的几何发散衰减: Adiv=20lg(r/r0) 4)面声源的几何发散衰减 根据《环境影响评价技术导则声环境》(HJ2.4-2021)中附录 A,当预测 点和面声源中心距离 r 处于以下条件时,可按下述方法近似计算:rb/π时,距离加倍衰减趋近于 6dB,类 似点声源衰减特性(Adiv≈20lg(r/r0))。其中面声源的 b>a。 (3)预测点 A 声级计算: 1)贡献值计算 预测点处的噪声贡献值采用下式计算: 式中: 129 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 Leqg——建设项目声源在预测点产生的噪声贡献值,dB(A); T——用于计算等效声级的时间,s; N——室外声源个数; ti——在时间内 i 声源工作时间,s; M——等效室外声源个数; tj——在 T 时间内 j 声源工作时间,s。 2)预测值(叠加背景值)计算 式中:Leq——预测点的噪声预测值,dB(A); Leqg——建设项目声源在预测点产生的噪声贡献值,dB(A); Leqb——预测点的背景噪声值,dB(A)。 5.2.4.5 评价方法 将预测点的等效声级与评价标准相对照,对厂界声环境质量预测结果进行 评价。 5.2.4.6 评价标准 本项目东厂界执行《工业企业厂界环境噪声排放标准》(GB12348-2008) 中 4a 类、南、西、北厂界执行 1 类。环境敏感点噪声执行《声环境质量标准》 (GB3096-2008)1 类标准。 5.2.4.7 预测结果及影响分析 根据厂区建设布局情况及工程拟采用的隔声降噪措施,选择主要高噪声源 对厂界的影响进行预测,各厂界噪声和项目 200 米范围环境敏感点影响情况预 测结果见表 5-17。 130 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 经构筑物隔声和距离衰减后,项目运营期厂界噪声预测结果如下: 表 5-17 项目实施后厂界噪声预测结果一览表(dB(A)) 东厂界 南厂界 西厂界 北厂界 丁寨(北厂界 178m) 郸城县气象局 (东南144m) 距离m 52 186 213 55 233 329 贡献值 30.7 19.6 18.4 30.2 17.7 14.7 距离m 138 200 132 43 221 343 贡献值 22.2 19.0 22.6 32.3 18.1 14.3 距离m 70 186 203 112 290 329 贡献值 28.1 19.6 18.9 24.0 15.8 14.7 距离m 195 196 76 46 224 339 贡献值 19.2 19.2 27.4 31.7 18.0 14.4 距离m 188 187 83 53 231 330 贡献值 9.5 9.6 16.6 20.5 7.7 4.6 距离m 47 211 224 27 205 354 贡献值 21.6 8.5 8.0 26.4 8.8 4.0 距离m 140 162 133 87 265 305 贡献值 12.1 10.8 12.5 16.2 6.5 5.3 距离m 255 34 16 210 388 177 贡献值 6.9 24.4 30.9 8.6 3.2 10.0 噪声源 门诊医技综合楼中 央空调风冷热泵机 组 呼吸道楼中央空调 风冷热泵机组 发热门诊中央空调 风冷热泵机组 后勤办公综合楼中 央空调风冷热泵机 组 后勤办公综合楼食 堂风机 门诊医技综合楼食 堂风机 水泵房水泵 污水站风机 131 郸城县人民医院西南院区新建项目环境影响报告书 液氧站空压机 叠加贡献值 背景值 预测值 第五章环境影响预测与评价 距离m 229 84 42 160 338 227 贡献值 7.8 16.5 22.5 10.9 4.4 7.9 昼间 33.5 28.4 33.7 37.1 23.9 21.4 夜间 33.2 28.3 33.6 36.6 23.7 21.2 昼间 / / / / 51 52 夜间 / / / / 42 43 昼间 / / / / 51.0 52.0 夜间 / / / / 42.1 43.0 《工业企业厂界环境噪 声排放标准》 (GB12348-2008)4类 (昼间≤70、夜间55) 评价标准 《声环境质量标准》(GB30962008)1类(昼间≤55、夜间45) 《工业企业厂界环境噪声排放标准》(GB123482008)1类(昼间≤55、夜间45) 表 5-18 项目实施后环境保护目标噪声预测结果一览表(dB(A)) 噪声背景值 噪声现状值 噪声标准 噪声贡献值 噪声预测值 较现状增量 超标和达标情况 昼间 夜间 昼间 夜间 昼间 夜间 昼间 夜间 昼间 夜间 昼间 夜间 昼间 夜间 丁寨(北厂界178m) 51 42 51 42 55 45 25.2 24.4 51.0 42.1 0 +0.1 达标 达标 郸城县气象局(东南144m) 52 43 52 43 55 45 22.8 22.1 52.0 43.0 0 0 达标 达标 噪声源 由上表看出,工程完成后,各厂界均可满足《工业企业厂界环境噪声排放标准》(GB12348-2008)1 类标准、4 类标准要求,周边敏感 点声环境质量能够满足《声环境质量标准》(GB3096-2008)1 类标准。工程噪声对周围环境影响较小,不会造成扰民现象。 132 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 5.2.5 固体废物环境影响分析 (1)固体废物来源和产生量 由工程分析可知,项目运营期固体废物主要为医务后勤人员办公及宿舍产 生的普通生活垃圾、餐厨垃圾、废反渗透膜(纯水制备)、门诊病房楼病人产 生的生活垃圾(属于医疗废物)、医疗废物、污水站栅渣及污泥、废紫外线含 汞灯管。各固体废物产生量及处理处置措施见表 5-19。 表 5-19 全院固体废物产生情况一览表 序号 污染物 产生途径 固废性质 全院产生量 处理措施 生活垃圾分类收集后, 医务后勤人员 1 日产日清,每天由环卫 办公及宿舍产 医务后勤人员 生的普通生活 办公及宿舍 一般固废 292t/a 垃圾 部门负责清运至市政垃 圾中转站,最终运至郸 城县生活垃圾焚烧厂发 电厂焚烧 采用专用餐厨垃圾收集 2 餐厨垃圾 食堂 一般固废 511t/a 桶收集,集中收集后交 由有资质的单位进行运 输处 置 3 废反渗透膜 (纯水制备) 纯水制备 一般固废 0.1t/a 更换后随生活垃圾一同 交环卫部门清运处理 经袋装收集后,暂存于 门诊、病房楼 4 医疗废物暂存间内,并 病人产生的生 门诊、病房楼 活垃圾(属于 病人 医疗废物 321.2 医疗废物) 按照医疗废物进行暂存 管理和处置,定期交由 有资质单位进行清运处 置 5 6 7 8 医疗废物 污水处理站产 生的污泥 污水处理站产 生的栅渣 废紫外线含汞 灯管 门诊科室及 病房楼 污水处理站 医疗废物暂存间暂存 危险废物 148.92 后,委托有资质单位进 行集中处理 危险废物 132.5821 消毒脱水后,作为危险 废物定期交有资质单位 污水处理站 危险废物 3.8492 紫外线消毒 危险废物 0.16 (1)一般固废环境影响分析 133 处置 危废间暂存后交由有资 质危废单位安全处置 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 本项目医务后勤人员办公及宿舍产生的普通生活垃圾产生量为 292t/a。根 据国卫办医发[2017]30 号《关于在医疗机构推进生活垃圾分类管理的通知》、 《生活垃圾分类制度实施方案》等要求,医疗机构内产生的生活垃圾按照属性 分为有害垃圾、易腐垃圾、可回收垃圾和其他垃圾四类,实行分类化收集、分 区存放,生活垃圾收集后由环卫部门分类清运、分开处置。医务后勤人员办公 及宿舍产生的普通生活垃圾生活垃圾存放于生活垃圾收集站,建筑面积为 95m2, 本项目将院区产生的生活垃圾由密闭式塑料垃圾桶收集到生活垃圾收集点,每 天由环卫部门集中清运处理,生活垃圾暂存间不进行垃圾处理,无压缩工艺。 餐厨垃圾产生量为 511t/a,采用专用餐厨垃圾收集桶收集,集中收集后交 由有资质的单位进行运输处 置。 生活垃圾站与最近的病房楼的水平距离 13m,位于医院常年主导风向的下 风向, 且生活垃圾站周围设置为绿化带, 故生活垃圾站对项目内部环境影响不 大, 并且生活垃圾站靠近医院污物出入口,方便生活垃圾清运, 故项目生活垃 圾站位置设置基本合理。 拟于食堂设置餐厨垃圾专用餐厨垃圾桶, 暂存于餐厨垃圾暂存处, 并保持 收集容器密封完好, 集中收集后, 每日交由有经营许可的餐厨垃圾收运单位进 行处理。 (2)危险固体废物环境影响分析 本项目门诊及病房楼产生的生活垃圾、污水处理站产生的污泥、栅渣、医 疗废物为危险废物,属《国家危险废物名录》中 HW01 医疗废物,医疗废物在 收集、贮存、转运过程中,应按照《医疗卫生机构医疗废物管理方法》(中华 人民共和国卫生部令第 36 号)、《医疗废物管理条例》,《医疗废物集中处置 技术规范(试行)》(环发[2003]206 号)、《医疗废物专用包装袋、容器和警 示 标 志 标 准 》 (HJ421-2008) 、 《 医 疗 废 物 转 运 车 技 术 要 求 ( 试 行 ) 》 (GB19217-2003)等相关规范执行。 134 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 本项目污泥总产生量 132.5821 t/a,栅渣总产生量 3.8492 t/a。由于本工程废 水水量较小且处理工艺简单,其污泥产生量较小,依据《医院污水处理技术规 范》要求,评价建议污水处理站污泥和栅渣在污泥消毒池内采用消毒剂消毒, 消毒后通过压滤机进行压滤脱水,危废暂存间暂存后作为危险废物交有资质单 位进行集中处理。本项目医疗废物产生量为 470.12t/a(含门诊及病房楼生活垃 圾 321.2t/a)。门诊及病房楼生活垃圾经袋装收集后,暂存于医疗废物暂存间内, 并按照医疗废物进行暂存管理和处置。环评建议本项目医疗废物收集后在医疗 废物暂存间暂存后,委托郸城县医疗固废处置场所进行集中处理。医疗废物暂 存间应严格按照《危险废物贮存控制污染标准》的要求进行建设,满足“三防” 要求。该临时贮存库房应定期进行消毒和清洁。医疗废物包括各类化学性、病 理性、药物、医疗器具等废物,属于《国家危险废物名录》中 HW01 医疗废物, 危险特性是传染性。 废紫外线含汞灯管产生量为 80 支/年约重 0.16t/a,根据《国家危险废物名 录(2021 年版)》,废紫外线灯管为 HW29 含汞废物 900-023-29 类废物,危废 间暂存后交由有资质危废单位安全处置。 本项目危险废物产生及处置情况见表 5-20。 表 5-20 本项目危险废物产生及处置情况一览表 名称 类别 (含医疗 废物和传 损伤性废 染病楼生 物 形 主要 危险 污染防治 (t/a) 工序 态 成分 特性 措施 In 001-01) 病理性废 医疗废物 药物性废 产生 (841- 物 物 产生量 HW01 感染性废 物 代码 活垃圾) HW01 (841003-01) HW01 固 470.12 日常诊疗 态 固 态 (841- 医疗 In 间暂存交 废物 由有资质 In 002-01) HW01 T/C/I/R (841005-01) 135 医疗废物 单位处置 郸城县人民医院西南院区新建项目环境影响报告书 HW01 化学性废 水处理 站污泥 T (841- 物 栅渣、污 第五章环境影响预测与评价 004-01) 危险 废物 废紫外线 危险 含汞灯管 废物 危废间暂 HW01 (841- 136.4313 001-01) 023-29) 处理站 态 污泥 In 存交由有 资质单位 处置 危废间暂 HW29 (900- 医疗污水 固态或泥 0.16 紫外线消 毒 固态 汞 T 存交由有 资质单位 处置 本项目设置一座占地面积为 50m2 的医疗废物储存间和一座占地面积为 25m2 的危险废物储存间,根据《危险废物贮存污染控制标准》(GB18597-2023) 和《危险废物收集贮存运输技术规范》(HJ2025-2012)的相关要求,危险废物 储存场所采取如下措施:①医疗废物暂存间地面基础应采取防渗,防渗系数能 够达到 10-10cm/s,暂存场所要达到防渗漏、防流失、防扬散、防雨淋的要求; ②医疗废物暂存间地面与裙脚应用坚固、防渗的材料建造,建筑材料必须与危 险废物相容。(2)企业须健全危险废物相关管理制度,并严格落实。①企业须 配备专业技术人员和管理人员专门负责企业危险废物统计、收集、暂存、转运 和管理工作,并对有关危废产生部门员工进行定期教育和培训,强化危险废物 管理;②企业须建立危险废物收集操作规程、危险废物转运操作规程、危险废 物暂存管理规程等相关制度,并认真落实;③企业须对危险废物储运场所张贴 警示标示,危险废物包装物张贴警示标签;④规范危险废物统计、建立危险废 物收集及储运有关档案,认真填写《危险废物项目区内转运记录表》,作好危 险废物情况的记录,记录上须注明危险废物的名称、来源、数量、特性和包装 容器的类别、入库日期、存放库位、废物 出库日期及接收单位名称等,并即时存档以备查阅。 (3)危险废物在危废库房内暂存期间应严格按照《危险废物贮存污染控制 标准》(GB18597-2023)和《危险废物收集贮存运输技术规范》(HJ20252012)的相关要求进行存储和管理。①必须将危险废物装入容器内进行密封装 136 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 运,禁止将不相容(相互反应)的危险废物在同一容器内混装;②盛装危险废 物的容器应当符合标准,材质要满足相应的强度要求且必须完好无损,容器材 质和衬里要与危险废物相容(不相互反应);③危险废物贮存前应进行检验, 确保同预定接收的危险废物一致,并登记注册,不得接收未粘贴符合规定的标 签或标签没按规定填写的危险废物;④必须定期对所贮存的危险废物包装容器 及贮存设施进行检查,发现破损,应及时采取措施清理更换。 本项目危险废物产生情况见表 5-21。 表 5-21 危险废物贮存场所(设施)基本情况一览表 序 号 1 贮存场所 (设 危险废物名 称 施)名称 医疗废物 暂存间 危险废物 医疗废物 栅渣、污水 2 危险废物 处理站污泥 暂存间 废紫外线含 汞灯管 类 占地面 积 别 HW01 50m2 HW01 25m2 HW29 贮存方式 专用容器 专用容器 分类存放 贮存能 贮存周 力 期 2t 2天 3t 10天 在采取上述相应固体废物污染防治措施基础上,项目产生的各类固体废物 对环境影响很小。 5.2.6 土壤环境影响分析 根据《环境影响评价技术导则土壤环境》(HJ964-2018)附录 A 表 A.1, 本项目属于“其他行业”,土壤环境影响评价项目类别为“Ⅳ类”,不需要进行土 壤环境影响评价。 本项目运营期间综合污水处理站、污水管网、医疗废物暂存间、污泥脱水 间、危废暂存间对土壤可能产生一定影响,经采取重点防渗措施后,对土壤影 响较小。 为避免项目运营期对土壤造成不利影响,根据导则评价对项目提出相应的 控制措施,主要措施具体如下: (1)源头控制 137 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 本项目污染源主要为废气、废水、固体废物,企业应加强管理,做好节能 减排和清洁生产工作,一方面减少污染物产生量,另一方面降低污染物排放浓 度和排放量。 (2)过程防控措施 本项目主要是对生产过程中产生的废气、废水、固体废物进行治理,加强 管理,保证环保设施的正常运行;普通生活垃圾按照要求进行硬化、防渗等处 理。 5.3 外环境对本项目的影响 根据现场调查,项目周边为农田和郸城县气象局,无环境敏感企业。郸城 县气象局距离医院厂界 144m,本项目为医院项目运行噪声对其影响不大。外环 境对本项目的影响源主要为周边道路,本项目与公园西路之间均隔有近 30 米绿 化带,对公园西路交通噪声起到了一定的隔声作用,经现场实测本项目东、西 南、北厂界昼夜噪声均满足《声环境质量标准》(GB3096-2008)1 类、4a 标准。 因此,评价认为公园西路对就诊及住院患者的就医影响不大。 为保证本项目建成后患者有一个好的就医环境,本环评建议采取以下治理 措施: 1)在临向公园西路一侧的主要建筑安装双层门窗,以确保噪声达标,提高 项目门窗的隔声性能,采用窗户加橡胶条、窗缝注密封胶,且采取符合国家“三 性”(气密性、水密性、隔声性)标准的玻璃;门窗进行嵌缝后可进一步提高隔 声量。 2)2)建设项目四周设置绿化带,可以起到隔噪音的作用。建议种植乔木、 灌木等四季常青的树种,以高低错落布置保证一定密度,并考虑种植可净化空 气的树种,如大叶黄杨、石榴、紫穗槐等。 5.3生态环境影响评价 5.3.1 概述 138 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 5.3.1.1 评价等级 根据《环境影响评价技术导则—生态影响》 (HJ19-2022)6.1.2 要求,本项目 占地不涉及国家公园、自然保护区、生态保护红线,项目不属于水文要素影响 型,不涉及天然林、公益林、湿地等保护目标,项目占地 65550m2<20km2,可 以确定项目的生态环境影响评价确定为三级。 5.3.1.2 评价范围 根据《环境影响评价技术导则生态影响》(HJ19-2011),确定本次生态影响 评价范围为项目区场址占地范围。 根据项目建设对生态环境的影响情况,结合项目所在区域的生态环境特征, 以及影响识别和评价因子的筛选结果,确定评价工作内容如下: 5.3.1.3 评价内容 (1)生态环境现状调查与评价 主要调查拟建项目区的生态系统、土地利用、动植物种类、文物古迹、景 观及水土流失现状等情况。 (2)生态影响预测与评价 ①施工期对动植物、水土流失影响及对策; ②施工期土地利用方式的变化及土地资源影响;对生物多样性动植物资源、 水土流失、景观影响分析; ③生态环境保护与恢复措施。 5.3.1.4 调查方法 现状调查采用收集资料、遥感调查方法,并结合现场校核的方法。 5.3.2 生态环境现状调查与评价 5.3.2.1 生态系统调查 经现场调查,拟建项目评价范围从结构和功能分析,评价区景观生态体系 主要为城市生态系统。 139 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 拟建项目位于郸城县郸城县科技大道北、公园西路西侧地块,通过 GoogleEarth 历史影像图与人员访谈了解到,该地块内现状为农田,项目建设后 取而代之为医疗用地,历史上无工矿企业存在。 5.3.2.2 土地利用现状调查 项目评价范围内土地利用类型包括农田。该地方目前已调整为医疗卫生用 地。 5.3.2.3 植被现状及野生动植物现状 项目所在地主要为县城生态环境,区域内人类活动频繁,评价区域内没有 自然保护区、风景名胜区和受国家保护的野生动植物种类,项目占地范围内主 要以农田人工生态环境为主,主要植被为人工栽培的树木。 根据现状踏勘及附图 19 项目区域植被类型图,项目占地范围植被类型主要 为农作物,具体种类包括小麦、玉米等。 项目占地范围的野生动物主要为农田生态系统生活的少量动物,地块内野 生动物的种类及数量都很少,以爬行类、小型啮齿类及部分常见鸟类为主。 5.3.2.4 生态保护目标 根据调查,项目地块范围内主要农田,不属于国家公园、自然保护区、自 然公园、世界自然遗产、生态保护红线、重要生境及其他具有重要生态功能、 对保护生物多样性具有重要意义的区域,不存在生态保护目标,本次评价不再 编制生态保护目标分布图。 5.3.3 生态环境影响分析 5.3.3.1 施工期生态环境影响分析 5.3.3.1.1 施工期对土地利用类型的影响分析 项目实施后,地块内耕地不再存在,全部调整为医疗卫生用地。项目占地 范围用地为永久建设用地,其造成区内用地不可逆的损失,使该区域内的农用 地的绝对减少,项目占地比例很小,对引起区域的土地利用格局变化小。 140 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 5.3.3.1.2 施工期对植被的影响分析 施工期的土石方开挖、弃土弃渣、施工材料和设备的堆放等施工活动将使 评价区范围内的植被遭受彻底破坏,原有的生态系统将逐步消失,施工完成后, 项目区进行硬化和绿化,绿化率将达到 35%。可以部分恢复原有植被的水分涵 养功能。在绿化树种的选择上,应优先选择适于本地气候和生态环境的树种, 并注意乔、灌、草结合,既要考虑生态功能,又要考虑美学和观赏价值。 5.3.3.1.3 施工期对动物的影响分析 施工期对陆生动物的直接影响是施工人员集中活动和工程施工过程对动物 的惊扰;间接影响主要是工业企业建设破坏植被和土壤,造成部分陆生动物栖 息地的丧失。但施工区没有发现重要的兽类的活动痕迹,主要动物是小动物, 且数量不多,具有较强的迁移能力,施工期间对两栖动物和爬行动物的活动有 一定的影响,项目区内主要的动物将会迁移到项目区附近的地区,对其生存不 会造成威胁。项目区域的鸟类将被迫离开原来的领域,邻近领域的鸟类由于受 到施工噪声的惊吓,也将远离原来的栖息地。项目区建设期间,野生动植物数 量较少,因此项目区的开发对其的影响较小。 5.3.3.2 营运期生态环境影响分析 项目建设后,项目区建设过程中产生的弃土、弃渣等得到有效处置,项目 区进行硬化和绿化,绿化率 35%。通过采取各种水土保持措施,使原有水土流 失状况得到基本控制,项目区范围及其周围地区的环境生态质量得到明显改善。 因此,项目区建设完成后,其配套采用的水土保持措施也同时发挥作用。运营 期对区域生态环境的影响主要表现在土地利用方式、植被、物种量、生物量、 水土流失、景观的变化等方面。 1、土地利用影响 项目区现土地利用类型为耕地,项目建成后,土地利用现状将全部变为医 疗卫生用地,为建设用地,具体包括建构筑物、绿化用地、道路等。 2、生物影响 141 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 (1)对植物的影响 项目区内植物为该地区常见种类,没有濒危等受保护植物种类,也不会改 变该地区的植物结构类型。项目建成后,人工绿地面积为 22942.5m2,构成区域 植被外貌,担当植被的生态功能。以乔灌草相结合的人工园林绿地系统,其功 能将向观赏型和生态型转变,绿化配置采用乔木-灌木-草本三个层次,绿化覆 盖率可达到 35%。人工绿地的功能主要是维持自然生态平衡,并提供舒适的居 住环境,提高景观质量。项目建成后,评价区绿覆盖率有所提高。 (2)对动物的影响 项目建成营运后,区域内喜鹊、燕子等鸟类动物不属于“领域”动物,它 们可以在人员虽多,但绿化较好的条件下生存繁衍。因此项目建成后及时恢复 区内植被,加强绿化,并对其进行生态优化、绿化率达到 35%的情况下,鸟类 所受的影响较小。 3、水土流失影响 随着工程的建设,不可避免地对项目区内的土壤产生扰动,降低了表层土 壤的抗蚀性,对现有植被造成破坏,产生新增水土流失。由于工程的开挖、取 土、填筑、堆置、碾压等施工,破坏了原地表土壤结构,使土地原有水土保持 功能降低或丧失,加剧项目区水土流失的发生和发展。因此,根据主体工程的 布局及施工特点,合理预测工程建设可能造成的水土流失量,可为水土流失防 治分区和治理奠定工作基础。本方案通过对主体工程设计情况和项目区自然、 社会情况定性分析的基础上,根据水土流失防治分区结果,对项目建设过程中 可能产生的水土流失情况进行定量的预测分析,区分水土流失的易发时段和主 要区域,并结合主体设计中已有的水土保持措施,确定合理的水土流失防治措 施。 4、生态保护与生态恢复补偿 针对拟建项目对生态环境的不利影响,必须制定切实可行的生态恢复和生 态防护措施,以保护当地的生态环境,保证其生态功能不退化。 142 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 (1)生态保护措施 项目开发建设中应注重生态保护,特别加强对场地外围周边植被保护和建 设中的绿化恢复。可通过以下途径进行保护: ①施工阶段 项目施工阶段严格要求、文明施工。可通过制定并执行严格的规章制度避 免对开发场地以外植被的破坏。如有破坏,则追究责任人并由责任人赔偿。由 于植被恢复需要一定时间,项目区采用分期建设,边建设边绿化,避免绿化跟 不上所造成的地面裸露情况 ②营运期阶段 营运期拟建项目物业管理部门应加强对区内绿化植被、景观的养护、保护 工作,杜绝植被、景观出现人为破坏现象,爱护、珍惜自已的“绿色家园”。 (2)生态补偿措施 项目建设施工过程中将造成区域原有自然景观单元面貌的改变,使地表结 构破碎化,景观格局将重新组合和展布。因临时用地及施工便道用地和施工期 其它因素等,使项目区域的土壤植被损失或损坏。 植被和土壤破坏将引发的主要问题是加剧地区土壤侵蚀,为了使破坏的植 被得到补偿,项目建设完毕后,对征地范围内的裸露地均进行植树、种草绿化。 临时用地、施工便道使用后也要翻土平整植树,及时进行绿化恢复。 项目建设完成后,要按照已有的绿化方案进行人工绿化对生态环境进行补 偿,具体生态补偿措施如下: ①注意乔、灌、草的比例 乔、灌、草各有其独特的生态功能,但总体来说,高大乔木在固碳释氧、 调节小气候、净化空气、减轻水土流失等的生态功能比灌木和草坪要大得多, 而灌木又比草坪要大得多,对草坪在吸纳雨水径流、美化等方面也有其独特的 功能。因此在绿化时,注意乔、灌、草的比例,建议其比例为 40:30:60。 ②绿化空间布局要保持一定的层次结构 143 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 有一定层次结构的绿化布局才能充分发挥其生态功能。包括乔、灌、草在 内的生物群落结构功能较完善,抗干扰能力强。绿化时遵循这种生态学原理。 在高大的乔木下至少要种植一层灌木和草本植物。 ③道路两侧和楼间绿地 特别是东西向的楼间绿化带的地面要低于建筑物和构筑物不透水地面,以 起到吸纳雨水,补充地下水的作用。 ④绿化品种宜多选择乡土种,并避免单一品种 绿化品种要在保证美化效果的条件下,尽量多样化,宜将乡土种和观赏树 种、花卉、草种有机结合起来,选择适应于当地气候和土质并具有观赏价值的 品种。在绿化品种上,避免单一,尽量多样化在选择绿化品种时,考虑植物在 不同季节叶、花的颜色,使之起到美化环境、调节视觉、恢复疲劳的作用。 (3)水土保持措施 ①水土流失综合防治措施总体布局 根据该工程建设特点及水土保持目标的要求,在水土流失防治分区的基础 上,统筹部署水土保持措施。做到主体工程设计与水土保持方案新增措施相结 合,工程措施与植物措施相结合,永久措施和临时防治措施相结合,重点治理 与综合防护相结合,形成水土流失综合防治措施体系,治理水土流失和恢复、 提高土地生产力相结合,确保项目建设期不造成新的水土流失,并有效治理项 目区原有水土流失。 防治措施体系将按照系统工程原理,处理好局部与整体、单项与综合的关 系,力争达到投资省、效益好、可操作性强,有效地控制防治责任范围内的水 土流失。同时,便于水土保持方案设计的措施能够有效融入拟建项目下一阶段 主体工程设计中。 ②水土流失综合防治措施体系 根据水土流失预测结果、水土流失重点危害区域和水土流失防治分区,针 对工程建设过程中可能引发水土流失的特点和危害程度,本工程水土流失防治 144 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 采取工程措施和植物措施、永久措施和临时防治措施相结合,建立完整有效的 水土流失防治措施体系。本方案确定的水土流失防治综合措施体系主要有以下 内容。 1)建筑用地区 建筑用地区的临时防护措施包括表土剥离措施、彩钢板隔离措施。 2)道路广场区 道路广场区的工程措施为排水沟工程、植草砖工程;植物措施包括行道树 种植措施、植草砖穴播植草措施;临时防护措施包括泥结石道路、防尘网覆盖 措施、临时沉砂池措施。 3)景观绿化区 景观绿化区的工程措施为雨水积蓄工程、土地整治、下凹式绿地;植物措 施包括铺植草皮、下凹式绿地撒播植草、植乔木、植灌木等;临时防护措施包 括表土剥离措施、临时拦挡措施和临时覆盖措施。 (3)不同防治措施典型设计 ①工程措施 1)铺设植草砖工程 植草砖是目前国内较为流行的一种园林路面铺筑技术,其指导思想是改变 过去路面全部硬化的做法,使地面与地下保持能量交换,包括水、气等。铺筑 材料是一种有孔透水混凝土构件,它一般具有 40%~50%的开孔率,承载能力 也异常优越,较大的开孔率也为植被生长提供了充分的培养土和水分,即使一 般草种在较差的环境(如经常碾压)下也能茂密生长。这种技术在不改变路面 承载能力的前提下,增加了绿化和美化效果。项目区内部分场地建设可以采纳 这种技术,将非机动车用路面、停车场等采用植草砖,提高水土保持水平。 植草砖铺设时,根据设计的要求,首先清理土方,并达到设计标高,按照 要求检查纵坡、横坡及边线是否符合设计要求,找平碾压密实,压实系数达 95%以上,并注意地下埋设的管线。其次,铺设 150~180mm 厚的级配砂石基 145 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 层(最大粒径不得超过 60mm,最小粒径不得超过 0.5mm),并找平碾压密实, 密实度达 95%以上。再次,用 30mm 厚中砂作为找平层,中砂要求具有一定的 级配,即粒径 0.3~5mm 的级配砂找平,该层也是透水层,便于植草砖保水。 最后,铺设面层植草砖,在铺设时,应根据设计图案铺设,应轻轻平放,用橡 胶锤锤打稳定,但不得损伤砖的边角。然后用营养土填充砖孔,再植草,浇水 养护。 从水土保持角度来看,该项技术具有很大的优点:一是相对于不透水构件, 可蓄渗雨水,回补地下水,涵养水源;二是在铺砖区使用该项技术,避免了大 面积的硬化,增加了绿化面积;三是能降低地表温度,湿润、净化空气,减少 粉尘,改善人居环境,提高生活环境质量,值得提倡。停车场可以采纳此项技 术,提高水土保持水平。 2)土地整治工程 建设区在施工完毕后需进行土地整治工程以恢复原利用方向。整地范围内 如需要进行复耕的,则按照规范要求,将表层土内遗留的碎石、施工垃圾及其 他不利于林木生长的杂物清除,然后按表层土清理-施有机肥-深耕方案进行, 整理完毕后,采取相应的绿化措施来美化项目区环境,增加地表植被覆盖率。 ②植物措施 1)苗木整地和栽培典型设计 绿化造林前,对土地进行全面整治,一般采取机械与人工结合的方式,对 表土层进行清理,去除土中遗留的碎石、施工垃圾及其他不利于苗木生长的杂 物,然后根据选用的苗木进行人工穴状整地,一般乔木坑穴的开挖尺寸为 0.8m ×0.8m×0.8m,灌木坑穴的开挖尺寸为 0.5m×0.5m×0.5m。 栽植苗木前,应严格按照苗木规格标准选苗。起苗前 2~3 天应浇水;起苗 时应起壮苗、好苗,防止弱苗、劣苗、病苗的混入;起苗后分级、包装、运输, 整个过程需注意根部保湿,防止受冻和遭风吹日晒,严防失水、损伤。苗木应 随起随植,如因故不能及时种植,对时间较长的,起苗后应采取假植措施;对 146 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 时间较短的,可采用浸过水的草苫覆盖。苗木栽植前应根据树苗品种、特点和 土壤墒情的不同,对苗木进行剪梢、截干、修根、剪枝、摘芽、苗根浸水、蘸 泥浆等处理,也可采用促根剂、蒸腾抑制剂和菌根制剂等处理。苗木栽植深度 一般应略过苗木根颈,穴坑大小和深度应略大于苗木根系,栽植时应使苗干竖 直、根系舒展、深浅适当;填土一半后提苗踩实,再填土踩实,浇水,最后覆 上虚土,填土要求熟土在下、生土在上。 栽植季节应根据苗木的生物学特性、项目区立地条件确定,一般选择早春 土壤解冻后或秋冬土壤结冻前进行,栽植时间一般选择苗木生长期间的阴天或 早、晚进行。根据乔灌品种、立地条件和培育的目的,确定造林密度。对于用 作隔离带的树林,可适当加大造林密度。乔木选择优质苗木,胸径达到 6cm, 灌木选择灌丛高 100cm 以上的苗木。 2)植草整地和栽培典型设计 植草前,对土地进行全面整治,整地深度取 0.4m,一般采取机械与人工结 合的方式,对表土层进行清理,去除土中遗留的碎石、施工垃圾及其他不利于 苗木生长的杂物,然后施有机肥、翻土、整平。 撒播种草时首先将精选的草种浸泡 24 小时,然后将草籽均匀地撒播在苗床 的表面,再用覆土耙覆熟土,最后用镇压器压平,以保证种子与土壤能够充分。 播种植草一般在春末夏初或夏季进行,播种时应避开大风天气。 ③临时措施 1)表土剥离措施 本方案的表土是指土地表层的熟化土壤,是为植物生长提供肥力的主要土 层,植被恢复常因缺乏可耕作的表土或覆土厚度偏薄而导致植物生长不良,因 此表土是一种宝贵的资源。为充分利用表土资源,根据有关规定应在施工前对 工程占地范围内表土进行剥离,并单独存放,用于工程区的绿化覆土。 147 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 在项目建设前,首先需要剥离表土,以便建设完工后用作绿化用土,剥离 厚度为 0.3m,剥离的表土开挖临时堆放于景观绿化用地处,草袋挡护,夯实堆 积边坡,设置排水沟;施工完成后将表土用于景观绿化覆土。 2)临时拦挡措施 为防止临时堆放的土石方发生水蚀和风蚀,本方案拟采取草袋临时挡土埂 方式予以防护。施工开始先将清理的表层土装入草袋,堆放在临时堆土的周边, 形成一道临时挡土埂,断面尺寸为 0.5m×0.5m。 3)临时覆盖措施 在建设期,项目内不可避免的出现临时堆土及临时堆放的砂石料,为防止 表面裸露的堆放物料产生风蚀危害,除了在堆土周边采取临时拦挡措施外,还 应采用临时覆盖防护措施,主要采用防尘网覆盖的形式进行。 5.3.4 景观影响 项目区景观原状是自然景观为主。随着项目区的开发与建设,该类型将由 规则建筑物、基础设施、道路以及人工绿地等人文景观类型取代,建筑物和道 路等拼块 的优势度上升较大。由于项目区规划中注重了景观绿地的规划,各类绿化 占地总面积为 22942.5m2,可以认为项目区规划绿地已基本达本地所要求的面积 和连通程度标准,并构成了生态环境质量的控制性组分,将对改善项目区生态 环境质量、美化项目区景观、调节区域小气候等起到积极作用。 因此建议项目区进一步对生态景观进行专项规划和设计,采用“点”、 “线”、“面”有机结合的绿地系统方案,大力进行科技居住地绿地的建设, 最大限度的利用非建设用地大力培植草地、树木,使项目区绿化率得到进一步 的提升。 5.4环境风险分析与评价 环境风险是指突发性灾难事故造成的重大环境污染的风险,具有危害性大、 影响范围广、处理难度大、发生概率难确定等特点,但一旦发生,其破坏性极 148 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 强、污染极严重,不仅会影响企业的正常生产、生活秩序,还可能造成人员伤 亡、生态环境的大范围破坏、国家财产遭受重大损失。 5.4.1 评价依据 根据《建设项目环境风险评价技术导则》(HJ169-2018)和《关于加强 环境响评价管理防范环境风险的通知》(环发[2005]152 号),结合项目生产工 艺、污染物性质和所在地环境特点,拟通过分析本项目中主要物料的危险性和 毒性,分析运行期间可能发生的突发性事件或事故(一般不包括人为破坏及自 然灾害),引起有毒有害和易燃易爆等物质泄漏,分析和预测建设项目存在的 潜在危险、有害因素,分析风险事故原因及环境影响,从而提出合理可行的防 范、应急与减缓措施,以使建设项目事故率、损失和环境影响达到可接受水平。 5.4.1.1 风险调查 5.4.1.1.1 物质风险调查 本项目风险物质主要是液氧站液氧、柴油发电机储油间柴油罐、污水站储 药间次氯酸钠,及化验室用到少量的盐酸、硫酸、甲醛、甲醇、84 消毒液、二 甲苯等存放在药品仓库。 由于医用液氧氧含量≥99.5% ,水分含量≤0.01g/m3 ,CO≤0.01% ,液氧 品质易燃易爆 等级为 0 ,为助燃物。故作为风险源考虑。 实验室用盐酸 37%存储量为 0.02t。液氧最大储存量为 17.115t(15m3 ,液 氧密度 1.141t/m3)。 表 5-22 序号 物质名称 主要风险物质储存 CAS 号 最大储存量 储存方式 1 液氧 7782-44-7 15m 2 柴油 68334-30-5 3 次氯酸钠(污水站) 7681-52-9 4 盐酸 5 3 储存位置 压力罐装 液氧站 1t 桶装 发电机房储油间 桶装 污水站储药间 7647-01-0 0.2t 0.02t 硫酸 7664-93-9 0.03t 瓶装 6 甲醇 67-56- 1 0.01t 瓶装 7 甲醛 50-00-0 0.01t 瓶装 8 84 消毒液 (次氯酸钠) 7681-52-9 0.4t 瓶装 9 二甲苯 1330-20-7 0.01t 瓶装 149 瓶装 药品仓库 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 本项目涉及的危险物质的理化性质见下表 表 5-23 液氧理化性质及危险特性 标识 中文名: 液氧 危险货物编号: 22002 英文名 :oxygen ,refrigerated liquid UN 编号: 1073 理化性质 分子式: O3 分子量: 32.00 外观与性状 CAS 号 :7782-44-7 常温下为无色、无臭气体,液化后成蓝色。 熔点 (℃) -218.8 沸点 (℃) 183. 1 1. 14 相对密度(水=1) 相对密度(空气=1) 饱和蒸气压 (kPa ) 1 .43 506.62 ( - 164℃) 溶解性 溶于水、乙醇。 侵入途径 吸入。 毒性 LD50 :无资料; LC50 :无资料 常压下,当氧的浓度超过 40%时,有可能发生氧中毒。吸入 40%-60%的 毒性及健康危害 氧 时,出现胸骨后不适感、轻咳,进而胸闷、胸骨后烧灼感和呼吸困 难,咳 嗽加剧;严重时可发生肺水肿,甚至出现呼吸窘迫综合征。吸入 健康危害 氧浓度在 80%以上时,出现面部肌肉抽动、面色苍白、眩晕、心动过 速、虚脱、继 而全身强直性抽搐、昏迷、呼吸衰竭而死亡。长期处于氧 分压为 60- 100kPa (相当于吸入氧浓度 40%左右) 的条件下可发生眼 损害严重者可失明。皮 肤接触液氧时可引起严重冻伤,导致组织损伤。 吸入:迅速脱离现场至空气新鲜处。保持呼吸道通畅,如呼吸停止,立 即 进行人工呼吸,就医。 急救方法 皮肤接触:皮肤与液体接触发生冻伤时,用大量水冲洗,不要脱掉衣 服, 并给予医疗护理。 眼睛接触:先用大量水冲洗数分钟,然后就医。 燃烧爆炸危险性 燃烧性 助燃 燃烧分解物 / 闪点(℃) / 爆炸上限 ( v%) / 引燃温度(℃) / 爆炸下限 ( v%) / 本身不燃烧,但能助燃,是易燃物、可燃物燃烧爆炸的基本元素之一, 与 易燃物 (如氢、乙炔等) 形成有爆炸性的混合物;化学性质活泼,能与 多 种元素化合发出光和热,也即燃烧。当氧与油脂接触则发生反应热, 危险特性 此热 蓄积到一定程度时就会自燃;当空气中氧的浓度增加时,火焰的温 度和火 焰长度增加,可燃物的着火温度下降;液氧易被衣物、木材、纸 张等吸收, 见火即燃;液氧和有机物及其它易燃物质共存时,特别是在 高压下,也具 有爆炸的危险性。 灭火方法 储运 条件 用水保持容器冷却,以防受热爆炸,急剧助长火势。迅速切断气源,用 水 喷淋保护切断气源的人员,然后根据着火原因选择适当灭火剂灭火。 储存于阴凉、通风的仓间内,仓内温度不宜超过 30℃ 。防止阳光直射。应与易燃气体、 金属 粉末分开存放。验收时应注意品名,注意验瓶日期,先进仓先发用。搬运时应轻装 轻卸,防 治包装和容器损坏。 迅速撤离泄漏污染区人员至上风处 , 并进行隔离 ,严格限制出入 。切断火源 。建议 应 泄漏 处理 急处理人员戴自给正压式呼吸器 , 穿一般作业工作服 。避免与可燃物或易燃物接 触 。 尽可能切断泄漏源 。合理通风 ,加速扩散 。漏气容器要妥善处理 ,修复 、检验 后再 用。 150 郸城县人民医院西南院区新建项目环境影响报告书 表 5-22 第五章环境影响预测与评价 柴油理化性质及危险特性 标识 中文名:柴油 危险货物编号:/ 英文名:Diesel oil;Diesel fuel UN 编号:/ 分子式:/ 理化性质 CAS 号:68334-30-5 分子量:230-500 外观与性状 稍有粘性的棕色液体 熔点 (℃) - 18 沸点 (℃) 282~338 0.87~0.9 相对密度(水=1) 相对密度(空气=1) 4 饱和蒸气压 (kPa) 溶解性 不溶于水 燃烧爆炸危险性 燃烧性 可燃 燃烧分解物 一氧化碳、二氧化碳 闪点 (℃) 38 爆炸上限 (v%) 5.0 引燃温度 (℃) 257 爆炸下限 (v%) 0.7 遇明火、高热或与氧化剂接触。有引起燃烧爆炸的危险。若遇高热,容 危险特性 器 内压增大,有开裂和爆炸的危险。对环境有危害,对水体和大气可造 成污 染。本品易燃有刺激性。 建规火险分级 甲 稳定性 禁忌物 稳定 聚合危害 不聚合 氧化剂 消防人员必须佩戴防毒面具、穿全身消防服,在上风向灭火。尽可能将 灭火方法 容 器从火场移至空旷处。喷水保持火场容器冷却,直至灭火结束,处在 火场 中的容器若已变色或从安全泄压装置中产生声音,必须马上撤离。 灭火剂: 雾状水、泡沫、二氧化碳、干粉、砂土。 侵入途径 吸入、食入。 急性毒性 LD50、LC50:无资料 毒性及健康危害 皮肤接触可为主要吸收途径,可致急性肾脏损害,柴油可引起接触性皮 健康危害 炎、 油性痤疮。吸入其雾滴或液体呛入可引起吸入性肺炎。能经胎盘进 入胎儿 血中,柴油废气可引起眼、鼻刺激症状,头晕及头痛。 皮肤接触:立即脱去污染的衣着,用大量清水冲洗。 眼睛接触:立即提起眼睑,用大量流动清水或生理盐水彻底冲洗至少 15 急救方法 分钟。就医。 吸入:迅速脱离现场至空气新鲜处。保持呼吸道通畅。如呼吸困难,给 输 氧。如呼吸停止,立即进行人工呼吸。就医。 食入:饮足量温水,催吐。就医。 工程控制:密闭操作,注意通风。 呼吸系统防护:空气中浓度超标时,建议佩戴自吸过滤式防毒面具 (半面罩) 。紧急事态 防护 抢 救或撤离时,应该佩戴空气呼吸器。 眼睛防护:戴化学安全防护眼镜。 身体防护:穿一般作业防护服。 手防护:戴橡胶耐油手套。 其他:工作现场严禁吸烟,避免长期反复接触。 储运条件 储存于阴凉、通风的库房。远离火种、热源。应与氧化剂、卤素分开存放,切忌混储。 采用 防爆型照明、通风设施。禁止使用易产生火花的机械设备和工具。储区应备有泄露 应急处理 设备。运输前应先检查包装容器是否完整、密封,运输过程中要确保容器不泄 漏、不倒塌、 不坠落、不损坏。运输时运输车辆应配备相应品种和数量的消防器材及泄 151 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 漏应急处理设备。 夏季最好早晚运输。运输时所用的槽 (罐) 车应接地链,槽内可设孔隔 板以减少震荡产生静 电。严禁与氧化剂、卤素、食用化学品等混装混运。运输途中应防 曝晒、雨淋、防高温。中 途停留时应远离火种,热源、高温区。装运该物品的车辆排气 管必须配备阻火装置,禁止使 用易产生火花的机械设备和工具装卸。运输车船必须彻底 清洗、消毒,否则不得装运其他物品。船运时,配装位置应远离卧室、厨房,并与机 舱、电源、火源等部位隔离。公路运输时 要按规定路线行驶。 泄漏处理 迅速撤离泄漏污染区人员至安全区,并进行隔离,严格限制出入。切断火源。建议应急 处理 人员戴自给正压式呼吸器,穿一般作业工作服。尽可能切断泄漏源。防止流入下水 道、排洪 沟等限制性空间。 小量泄漏:用活性炭或其他惰性材料吸附或吸收。 大量泄漏:需构筑围堤或挖坑收容。用泵转移至槽车或专用收集器内,回收或运至废物 处理 场所处置。 表 5-24 盐酸理化性质及危险特性 标识 中文名: 盐酸; 氢氯酸 危险货物编号: 81013 英文名 :Hydrochloric acid;Chlorohydric acid UN 编号: 1789 分子式: HCl 分子量: 36.46 理化性质 外观与性状 CAS 号 :7647-01-0 无色或微黄色发烟液体,有刺鼻的酸味。 熔点 (℃) - 114.8 沸点 (℃) 108.6 1.20 相对密度(水=1) 1 .26 相对密度(空气=1) 饱和蒸气压 (kPa ) 30.66/21℃ 溶解性 与水混溶,溶于碱液。 侵入途径 吸入 、食入 、经皮吸收。 LD50 :900mg/kg(兔经口); 毒性 LC50 :3124ppm ,1 小时(大鼠吸入) 毒性及健康危害 接触其蒸气或烟雾,可引起急性中毒,出现眼结膜炎,鼻及口腔粘膜有 烧 灼感,鼻衄、齿龈出血,气管炎等。误服可引起消化道灼伤、溃疡形 健康危害 成, 有可能引起胃穿孔、腹膜炎等。眼和皮肤接触可致灼伤。慢性影 响:长期 接触,引起慢性鼻炎、慢性支气管炎、牙齿酸蚀症及皮肤损 害。 皮肤接触:立即用水冲洗至少 15 分钟。或用 2%碳酸氢钠溶液冲洗。若 有 灼伤,就医治疗。眼睛接触:立即提起眼睑,用流动清水冲洗 10 分 钟或 用 2%碳酸氢钠溶液冲洗。吸入:迅速脱离现场至空气新鲜处。呼 急救方法 吸困难 时给输氧。给予 2-4%碳酸氢钠溶液雾化吸入。就医。食入:误 服者立即 漱口,给牛奶、蛋清、植物油等口服,不可催吐。立即就医。 燃烧爆炸危险性 燃烧性 不燃 燃烧分解物 氯化氢。 闪点(℃) / 爆炸上限 ( v%) / 引燃温度(℃) / 爆炸下限 ( v%) / 危险特性 建规火险分级 能与一些活性金属粉末发生反应,放出氢气。遇氰化物能产生剧毒的氰 化 氢气体。与碱发生中合反应,并放出大量的热。具有强腐蚀性。 戊 稳定性 稳定 聚合危害 不聚合 禁忌物 碱类、胺类、碱金属、易燃或可燃物。 灭火方法 用碱性物质如碳酸氢钠、碳酸钠、消石灰等中和。也可用大量水扑救。 152 郸城县人民医院西南院区新建项目环境影响报告书 储运 条件 第五章环境影响预测与评价 储存于阴凉、干燥、通风处。应与易燃、可燃物,碱类、金属粉末等分开存放。不可混储 混 运。搬运时要轻装轻卸,防止包装及容器损坏。分装和搬运作业要注意个人防护。运 输按规 定路线行驶。 疏散泄漏污染区人员至安全区,禁止无关人员进入污染区,建议应急处理人员戴好面罩, 穿 化学防护服。不要直接接触泄漏物,禁止向泄漏物直接喷水。更不要让水进入包装容 泄漏 器内。 用沙土、干燥石灰或苏打灰混合,然后收集运至废物处理场所处置。也可以用大 处理 量水冲洗, 经稀释的洗水放入废水系统。如大量泄漏,利用围堤收容,然后收集、转 移、回收或无害处 理后废弃。 表 5-25 标识 硫酸理化性质及危险特性 中文名:硫酸 危险货物编号:81007 英文名:sulfuric acid UN 编号:1830 分子式:H2SO4 CAS 号:7664-93-9 分子量:98.08 外观与性状 纯品为无色透明油状液体,无臭。 理化 熔点 (℃) 10.5 性质 沸点 (℃) 330.0 相对密度(水=1) 1.83 相对密度(空气=1) 饱和蒸气压 (kPa) 溶解性 3.4 0. 13 (145.8℃) 与水混溶。 燃烧性 不燃 燃烧分解物 / 闪点 (℃) / 爆炸上限 (v%) / 引燃温度(℃) / 爆炸下限 (v%) / 遇水大量发热,可发生沸溅。与易燃物 (如苯) 和可燃物 (如糖、纤维素等) 接 危险特性 燃烧 触会发生剧烈反应,甚至引起燃烧。遇电石、高氯酸盐、硝酸盐、苦味酸 盐、金属粉末等猛烈反应,发生爆炸或燃烧。有强烈的腐蚀性和吸水性。 爆炸 建规火险分 危险 级 性 禁忌物 乙 稳定性 稳定 聚合危害 不聚合 碱类、碱金属、水、强还原剂、易燃或可燃物 砂土。禁止用水。消防器具 (包括 SCBA) 不能提供足够有效地防护。若不 小 心接触,立即撤离现场,隔离器具,对人员彻底洗污。蒸气比空气重,易 在 灭火方法 低处聚集。储存容器及其部件可能向四面八方飞射很远。如果该物质或被 污 染的流体进入水路,通知有潜在水体污染的下游用户,通知地方卫生、消 防 官员和污染控制部门。在安全防爆距离以外,使用雾状水冷却暴露的容器。 侵入途径 急性毒性 吸入、食入、经皮吸收。 LD50:2140mg/kg (大鼠经口) LC50:510mg/m3 2 小时 (大鼠吸入) ;510mg/m3 2 小时 (小鼠吸入) 本品对皮肤、粘膜等组织有强烈刺激和腐蚀作用。对眼睛可引起结膜炎、水 毒性 肿、角膜混浊,以致失明;引起呼吸道刺激症状,重者发生呼吸困难和肺水 及健 肿;高浓度可引起喉痉挛或声门水肿而死亡。口服后引起消化道烧伤以致溃 康危 健康危害 疡形成。严重者可能有胃穿孔、腹膜炎、喉痉挛和声门水肿、肾损害、休克 害 等。皮肤灼伤轻者出现红斑、重者形成溃疡,愈后瘢痕收缩影响功能。溅入 眼内可造成灼伤,甚至角膜穿孔、全眼炎以至失明。慢性影响:牙齿酸蚀 症、 慢性支气管炎、肺气肿和肺硬化。 急救方法 皮肤接触:脱去污染的衣着,立即用水冲洗至少 15 分钟。或用 2%碳酸氢钠 溶液冲洗。就医。 153 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 眼睛接触:立即提起眼睑,用流动清水或生理盐水彻底冲洗至少 15 分钟。 就医。吸入:迅速脱离现场至空气新鲜处。呼吸困难时给输氧。给予 2-4% 碳酸氢 钠溶液雾化吸入,就医。 食入:误服者给牛奶、蛋清、植物油等口服,不可催吐。立即就医。 储运 储存于阴凉、干燥、通风的库房。应与易燃、可燃物,碱类、金属粉末等分开存放。不可 条件 混 储混运。搬运时要轻装轻卸,防止包装及容器损坏。分装和搬运作业注意个人防护。 疏散泄漏污染区人员至安全区,禁止无关人员进入污染区,应急处理人员戴好面罩,穿化 学 防护服。不要直接接触泄漏物,勿使泄漏物与可燃物质 (木材、纸、油等) 接触,在确 泄漏 处理 保安 全情况下堵漏。喷水雾减慢挥发,但不要对泄漏物或泄漏点直接喷水。用沙土、干 燥石灰或 苏打灰混合,然后收集运至废物处理场所处置。也可以用大量水冲洗,经稀释 的洗水放入废 水系统。如大量泄漏,利用围堤收容,然后收集、转移、回收或无害处理 后废弃。 表 5-26 甲醇理化性质及危险特性 标识 中文名: 甲醇 危险货物编号:32058 英文名:methyl alcohol;Methnol UN 编号:1230 分子式:CH4O 理化性质 CAS 号:67-56- 1 分子量:32.04 外观与性状 无色澄清液体,有刺激性气味。 熔点 (℃) -97.8 沸点 (℃) 64.8 0.79 相对密度(水=1) 相对密度(空气=1) 饱和蒸气压 (kPa) 溶解性 1. 11 13.33 (21.2℃) 溶于水,可混溶于醇、醚等多数有机溶剂 燃烧性 易燃 燃烧分解物 一氧化碳、二氧化碳 闪点 (℃) 11 爆炸上限 (v%) 44.0 引燃温度(℃) 385 爆炸下限 (v%) 5.5 燃烧爆炸危险性 危险特性 易燃,其蒸气与空气可形成爆炸性混合物。遇明火、高热能引起燃烧爆 炸。 与氧化剂接触发生化学反应或引起燃烧。在火场中,受热的容器有爆 炸危险。 其蒸气比空气重,能在较低处扩散到相当远的地方,遇明火会引 着回燃。 建规火险分级 禁忌物 甲 稳定性 稳定 聚合危害 不聚合 酸类、酸酐、强氧化剂、碱金属 消防人员必须佩戴防毒面具、穿全身消防服,在上风向灭火。尽可能将容 灭火方法 器 从火场移至空旷处。喷水保持火场容器冷却,直至灭火结束,处在火场 中的 容器若已变色或从安全泄压装置中产生声音,必须马上撤离。灭火 剂:抗溶 性泡沫、二氧化碳、干粉、砂土。 毒性及健康危害 侵入途径 吸入、食入、经皮吸收。 急性毒性 LD50:5628mg/kg (大鼠经口) ;15800mg/kg (兔经皮) ; LC50:83776mg/m3, 4 小时 (大鼠吸入) 。 对中枢神经系统有麻醉作用;对视神经和视网膜有特殊选择作用,引起病 变; 可致代谢性酸中毒。 急性中毒:短时大量吸入出现轻度眼及上呼吸道刺激症状 (口服有胃肠道 健康危害 刺 激症状) ;经一段时间潜伏期后出现头痛、头晕、乏力、眩晕、酒醉 感、意 识朦胧、谵妄,甚至昏迷。视神经及视网膜病变,可有视物模糊、 复视等, 重者失明。代谢性酸中毒时出现二氧化碳结合力下降、呼吸加速 154 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 等。 慢性影响:神经衰弱综合征,植物神经功能失调,粘膜刺激,视力减退 等, 皮肤出现脱脂、皮炎等。 皮肤接触:立即脱去污染的衣着,用肥皂水和清水彻底冲洗皮肤。 眼睛接触:提起眼睑,用流动清水或生理彻底冲洗。就医。 急救方法 吸入:迅速脱离现场至空气新鲜处。保持呼吸道通畅。如呼吸困难,给输 氧。 如呼吸停止,立即进行人工呼吸。就医。 食入:饮足量温水,催吐,洗胃。就医。 储存于阴凉、通风的库房。远离火种、热源。防止阳光直射;保持容器密封。应与氧化 剂、 酸类、碱金属等分开存放,切忌混储。储存间内采用防爆型照明、通风设施。禁止 使用易产 生火花的机械设备和工具。储区应备有泄露应急处理设备。运输前应先检查包 储运条件 装容器是否完 整、密封,运输过程中要确保容器不泄漏、不倒塌、不坠落、不损坏。运 输时运输车辆应配 备相应品种和数量的消防器材及泄漏应急处理设备。夏季最好早晚运 (罐) 车应接地链,槽内可设孔隔板以减少震荡产生静电。严禁与 输。运输时所用的槽 氧化剂、酸类、碱金属、 食用化学品等混装混运。运输途中应防曝晒、雨淋、防高温。 中途停留时应远离火种,热源、 高温区。装运该物品的车辆排气管必须配备阻火装置, 禁止使用易产生火花的机械设备和工 具装卸。运输车船必须彻底清洗、消毒,否则不得 装运其他物品。船运时,配装位置应远离 卧室、厨房,并与机舱、电源、火源等部位隔 离。公路运输时要按规定路线行驶。 迅速撤离泄漏污染区人员至安全区,并进行隔离,严格限制出入。切断火源。建议应急 泄漏处理 处理 人员戴自给正压式呼吸器,穿消防防护服。不要直接接触泄漏物。尽可能切断泄漏 源。防止 流入下水道、排洪沟等限制性空间。 小量泄漏:用砂土或其它不燃材料吸附或吸收。也可以用大量水冲洗,洗液稀释后放入 废水 系统。 大量泄漏:需构筑围堤或挖坑收容;用泡沫覆盖,降低蒸气灾害。用防爆泵转移至槽车 或专 用收集器内,回收或运至废物处理场所处置。 表 5-27 甲醛理化性质及危险特性 中文名: 甲醛;福尔马林 危险货物编号:/ 英文名:formaldehyde UN 编号:83012 标识 分子式:CH2O CAS 号:50-00-0 分子量:30.03 外观与性状 无色,具有刺激性和窒息性的气体,商品为其水溶液。 理化 熔点 (℃) -92 性质 沸点 (℃) - 19.4 0.82 相对密度(水=1) 饱和蒸气压 (kPa) 溶解性 1.07 相对密度(空气=1) 13.33 ( -57.3℃) 易溶于水,溶于乙醇等多数有机溶剂。 燃烧性 易燃 燃烧分解物 一氧化碳、二氧化碳、氧化氮 闪点 (℃) 50 爆炸上限 (v%) 73 引燃温度 (℃) 430 爆炸下限 (v%) 7.0 危险特性 甲醛溶液容易气化,放出甲醛气体,在空气中易燃。其蒸汽与空气可形 燃烧 成 爆炸性混合物。遇明火、高热能引起燃烧爆炸。与氧化剂接触猛烈反 爆 应。 炸危 建规火险分级 险 禁忌物 乙 稳定性 稳定 聚合危害 氧化剂、碱性物品、遇湿易燃物品 155 聚合 郸城县人民医院西南院区新建项目环境影响报告书 性 第五章环境影响预测与评价 用水保持火场中容器冷却,喷射逸出液体,使其稀释成不燃性混合物, 灭火方法 并 用雾状水保护消防人员。灭火剂:雾状水、抗溶性泡沫、二氧化碳、 干粉、 砂土。 侵入途径 吸入、食入、经皮吸收。 急性毒性 LD50: 800mg/kg (大鼠经口) ,2700mg/kg (兔经皮) LC50:590mg/m3 (大鼠吸入) 本品对粘膜、上呼吸道、眼睛和皮肤有强烈刺激性。接触其蒸汽,引起 结 膜炎、角膜炎、鼻炎、支气管炎;重者发生喉痉挛、声门水肿和肺炎 健康危害 等。 肺水肿较少见。对皮肤有原发性刺激和致敏作用,可致皮炎;浓溶 毒性 液可引 起皮肤凝固性坏死。 口服灼伤口腔和消化道,可发生胃肠道穿 及 孔,休克, 肾和肝脏损害。慢性影响:长期接触低浓度甲醛可有轻度 健康 眼、鼻、咽喉刺 激症状,皮肤干燥、皲裂、 甲软化等。 危 皮肤接触:脱去污染的衣着,用肥皂水及清水彻底冲洗。或用 2%碳酸 害 氢 溶液冲洗。 眼睛接触:立即提起眼睑,用流动清水或生理盐水彻底冲洗至少 15 分 急救方法 钟。 吸入:迅速脱离现场至空气新鲜处。保持呼吸道通畅。必要时进行人工 呼 吸。就医。如果呼吸困难,给予吸氧,如果患者食入或吸入该物质不 要用 口对口进行人工呼吸,可用单向阀小型呼吸器或其他适当的医疗呼 吸器。 食入:患者清醒时立即簌口,洗胃。就医。 密闭操作,提供充分的局部排风。操作人员必须经过专门培训,严格遵守操作规程。建 操作 议 操作人员佩戴自吸过滤式防毒面具 (全面罩) ,穿橡胶耐酸碱服,戴橡胶手套。远离火 处 种、 热源,工作场所严禁吸烟。使用防爆型的通风系统和设备。防止蒸汽泄漏到工作场 置注 所空气 中。避免与氧化剂、酸类、碱类接触。搬运时要轻装轻卸,防止包装及容器损 意 坏。配备相 应品种和数量的消防器材及泄漏应急处理设备。倒空的容器可能残留有害 事项 物。 储存于阴凉、通风的库房。远离明火、热源。库温不宜超过 30℃ ,.冬季应保持库温不 储运 低于 10℃ 。包装要求密封,不可与空气接触。应与氧化剂、酸类、碱类物品、遇湿易燃 条 件 物品隔 离储运。防止阳光曝晒引起胀桶。保持容器密封。库房内储存温度: 10%分开存 放,切忌 混储。采用防爆型照明、通风设施。禁止使用易产生火花的机械设备和工具。 储区应备有 泄露应急处理设备和合适的收容材料。 迅速撤离泄漏污染区人员至安全区,并进行隔离,严格限制出入。切断火源。建议应急 处 理人员戴自给正压式呼吸器,穿防酸碱工作服。从上风处进入现场。尽可能切断泄漏 源。 防止流入下水道、排洪沟等限制性空间。 泄漏 小量泄漏:用砂土或其它不燃材料吸附或吸收。也可以用大量水冲洗,洗水稀释后放入 处理 废 水系统。 大量泄漏:需构筑围堤或挖坑收容。用泡沫覆盖,降低蒸汽灾害。喷雾状水冷却和稀释 蒸 汽、保护现场人员、把泄漏物稀释成不燃物。用泵转移至槽车或专用收集器内,回收 或运 至废物处理场所处置。 标 识 表 5-28 次氯酸钠理化性质及危险特性 中文名:次氯酸钠 危险货物编号:/ 156 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 英文名:fsodium hypochlorite solution 分子式:CH2O UN 编号:830501 理化性质 CAS 号:7681-52-9 分子量:74.44 外观与性状 微黄色溶液,有似氯气的气味。 熔点 (℃) -6 沸点 (℃) 102.2 1. 10 相对密度(水=1) 相对密度(空气=1) 饱和蒸气压 (kPa) 溶解性 / 溶于水 燃烧爆炸危险性 燃烧性 不燃 燃烧分解物 / 闪点 (℃) / 爆炸上限 (v%) / 引燃温度 (℃) / 爆炸下限 (v%) / 危险特性 / 与有机物、 日光接触发出有毒的氯气。对大多数金属有轻微的腐蚀。与 酸 接触时散出具有强刺激性和腐蚀性气体。 建规火险分级 戊 稳定性 不稳定 聚合危害 不聚合 毒性及健康危害 禁忌物 还原剂、易燃或可燃物、 自燃物、酸类、碱类 灭火方法 使用雾状水、泡沫、二氧化碳、砂土灭火。 侵入途径 吸入、食入、经皮吸收。 急性毒性 LD50:5800mg/kg (小鼠经口) ; LC50:无资料 健康危害 次氯酸钠放出的游离氯可引起中毒,亦可引起皮肤病。已知本品有致敏 作 用。用次氯酸钠漂白液洗手的工人,手掌大量出汗,指甲变薄,毛发 脱落。 皮肤接触:脱去污染的衣着,用大量流动清水冲洗。 眼睛接触:提起眼睑,用流动清水或生理盐水冲洗。 急救方法 吸入:迅速脱离现场至空气新鲜处。保持呼吸道通畅。如果呼吸困难, 给 予吸氧,如呼吸停止,立即进行人工呼吸,就医。 储运条件 食入:饮足量温水,催吐。就医。 储存于阴凉、干燥、通风的库房。远离明火、热源,防止阳光直射。应与还原剂、易燃 或可 燃物、酸类、碱类分开存放。分装和搬运作业应注意个人防护,搬运时应轻装轻 卸,防止包 装和容器损坏。 泄漏处理 迅速撤离泄漏污染区人员至安全区,并进行隔离,严格限制出入。建议应急处理人员戴 自给 正压式呼吸器,穿一般作业工作服。不要直接接触泄漏物。尽可能切断泄漏源。防 止流入下 水道、排洪沟等限制性空间。 小量泄漏:用砂土、蛭石或其它惰性材料吸附或吸收。 大量泄漏:需构筑围堤或挖坑收容。用泡沫覆盖,降低蒸汽灾害。用泵转移至槽车或专 用收 集器内,回收或运至废物处理场所处置。 表 5-29 标识 二甲苯理化性质及危险特性 中文名:二甲苯 危险货物编号:33535 英文名:Xylene UN 编号:1307 分子量:106. 17 分子式:C8H10 外观与性状 CAS 号:95-47-6 无色透明液体,有类似甲苯的气味 理化 熔点 (℃) -25.5 性质 沸点 (℃) 144.4 相对密度(水=1) 0.88 饱和蒸气压 (kPa) 相对密度(空气=1) 1.33 (32℃) 溶解性 不溶于水,可混溶于乙醇、乙醚、氯仿等多数有机溶剂 燃烧性 易燃 燃烧分解物 157 3.66 一氧化碳、二氧化碳 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 闪点 (℃) 25 爆炸上限 (v%) 7.0 引燃温度(℃) 463 爆炸下限 (v%) 1.0 其蒸汽与空气形成爆炸性混合物,遇明火、高热能引起燃烧爆炸。与氧 燃烧 危险特性 化 剂能发生强烈反应。其蒸汽比空气重,能在较低处扩散到相当远的地 爆炸 方, 遇火源引着回燃。若遇高热,容器内压增大,有开裂和爆炸的危 危险 险。流速 过快,容易产生和积聚静电。 性 建规火险分级 甲 稳定性 稳定 聚合危害 不聚合 禁忌物 强氧化剂 灭火方法 喷水冷却容器,可能的话讲容器从火场移至空旷处。灭火剂:泡沫、干 粉、 二氧化碳、砂土。 侵入途径 吸入、食入、经皮吸收。 急性毒性 LD50:1364mg/kg (小鼠静脉) 对眼及上呼吸道有刺激作用,高浓度时对中枢神经系统有麻醉作用。急 性 中毒:短期内吸入较高浓度本品可出现眼及上呼吸道明显的刺激症 毒性 健康危害 状、眼 结膜及咽充血、头晕、头痛、恶心、呕吐、胸闷、四肢无力、意 及健 识模糊、 步态蹒跚。重者可由躁动、抽搐或昏迷,有的有癔病样发作。 康危 慢性影响: 长期接触有神经衰弱综合症,女工有月经异常,工人常发生 害 皮肤干燥、皲 裂、皮炎。 皮肤接触:立即脱去污染的衣着,用肥皂水和清水彻底冲洗皮肤。 眼睛接触:提起眼睑,用流动清水冲洗。就医。 急救方法 吸入:迅速脱离现场至空气新鲜处。保持呼吸道通畅。如呼吸困难,给 输 氧。如呼吸停止,立即进行人工呼吸。就医。 食入:饮足量温水,催吐。就医。 储运 储存于阴凉、通风的库房。远离火种、热源。库温不宜超过 26℃ 。保持容器密封。应 条件 与氧 化剂、还原剂、碱类分开存放,切忌混储。采用防爆型照明、通风设施。禁止使用 易产生 火花的机械设备和工具。储区应备有泄漏应急处理设备和合适的收容材料。 迅速撤离泄漏污染区人员至安全区,并进行隔离,严格限制出入。切断火源。建议应急 泄漏 处 理人员戴自给正压式呼吸器,穿消防防护服。尽可能切断泄漏源。防止流入下水道、 处理 排洪 沟等限制性空间。小量泄漏:用砂土或其它不燃材料吸附或吸收。也可以用大量水 冲洗, 洗水稀释后放入废水系统。大量泄漏:构筑围堰 或挖坑收容。用泡沫覆盖,降 低蒸气灾害。 用防爆泵转移至槽车或专用收集器内,回收或运至废物处理场所处置。 5.4.1.1.2 风险源及风险种类调查 根据工艺分析,结合物质危险性及毒性分析,本项目风险源包括液氧罐过 压爆炸、柴油泄漏遇明火发生的火灾、污水站次氯酸钠泄漏、化验室用化学试 剂泄漏、污水处理设施事故性排放、危险废物在暂存、运输等过程处置不当引 起的泄漏风险。 (1)液氧罐过压爆炸 158 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 液氧站储存 3 个 5m3 液氧罐。液氧在暂存过程中若管理不善可能发生泄漏 事故,泄漏后遇到明火易发生火灾事故。氧气罐遇到碰撞、高温暴晒、靠近明 火时可能发生过压爆炸。 (2)柴油罐泄漏 本项目在发电机房储油间使用柴油罐存储备用柴油,通过油泵供给柴油发 电机。 在存储或使用过程中,一旦柴油罐破损或倾倒,易造成柴油泄漏,如未 及时收集清理,柴 油外流污染土壤,遇明火可引起火灾,污染大气,消防水污 染土壤,进入水体污染地表水。 (4)污水站次氯酸钠泄漏 本项目医院废水采用次氯酸钠进行消毒。次氯酸钠若发生泄漏,会对医院 废水水质造成影响。 (5)化验室用化学试剂泄漏 由于本项目涉及使用化学品,包括 84 消毒液 (含有次氯酸钠) 、甲醇、甲 醛、 二甲苯等化学试剂。若发生泄漏,会对医院废水水质造成影响。 类比相关医院的使用情况,医院使用的化学品一般情况为限量购买, 且均 为小包装,在发生泄漏事故时易于控制,其贮存量远低于《建设项目环境风险 评价 技术导则》 (HJ169-2018) 中所规定的贮存临界量,危险化学品的环境风 险可以被控制 在非常有限的范围以内。危险化学品在医院的使用过程中发生的 泄漏事故,影响范围为 医院内的局部地区,对医院外的环境影响较小。 (6)污水处理设施 本项目设置 1 套废水处理设施,废水处理装置的事故类型主要是机械设备 出现故障,致使处理设施无法运转,废水得不到及时处理而直接排放,发生事 故性排放外排废水的 COD、BOD5 等污染物超标排放,会对郸城县第三污水处 理厂水质产生一定影响。 (7)废气处理设施 159 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 本项目地下污水处理站恶臭负压收集后经生物除臭+紫外线消毒后经管道引 至附近病房楼楼顶排放(约 20m),若废气处理设施发生故障不能正常运行, 恶臭污染物发生事故性排放,会对周围环境空气产生不利的影响。 (8)危险废物 本项目产生的医疗固体废物主要为临床和手术室产生的损伤性、感染性及 病理性等医疗废物,均属于危险固废,若管理不善,在储存或运输途中如果出 现事故,将导致医疗废物遗失或散落,对周围环境及人群健康造成影响。 (9)臭氧发生器风险分析 医院传染性废水采用臭氧进行预消毒,通过臭氧发生器自制。臭氧具有极 强氧化性。臭氧泄露环境空气后,周围人群接触后,强烈刺激人的呼吸道,造 成咽喉肿痛、胸闷咳嗽、引发支气管炎和肺气肿;臭氧会造成人的神经中毒, 头晕头痛、视力下降、记忆力衰退;臭氧会对人体皮肤中的维生素 E 起到破坏 作用,致使人的皮肤起皱、出现黑斑;臭氧还会破坏人体的免疫机能,诱发淋 巴细胞染色体病变,加速衰老,致使孕妇生畸形儿。发生泄漏时,切断气源, 喷洒雾状水稀释,漏气容器不能再用,清除泄漏的气体。 本项目臭氧发生器使用人员严格按照使用说明进行操作,即制备即使用, 存贮量较少,正常工作时消毒剂溶解于水中,极少量无组织挥发;停水时立即 关闭电源,避免消毒气体泄漏,对周围大气环境影响较小。 5.4.1.2 环境风险潜势初判 根据《建设项目环境风险评价技术导则》(HJ169-2018)附录 B 表 B.1 中 突发环境事件风险物质,本项目风险物质主要是液氧站液氧、柴油发电机储油 间柴油罐、污水站储药间次氯酸钠,及化验室用到少量的盐酸、硫酸、甲醛、 甲醇、84 消毒液、二甲苯等化学试剂存放在药品仓库。 参考《危险化学品重大危险源辨识》(GB 18218-2018),液氧临界值为 200t。本项目危险化学品最大储存量与临界量对比情况见表 5-30。 表 5-30 本项目风险物质临界量与实际储存量对比一览表 160 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 危险物质名称 最大储存量(t) 临界量(t) 该种危险物质的Q 液氧 17.115 200 0.0856 柴油 1 5000 0.0002 次氯酸钠(污水站) 0.2 5 0.0400 化验室盐酸(37%) 0.02 7.5 0.0027 硫酸 0.03 10 0.0030 甲醇 0.01 10 0.0010 甲醛 0.01 0.5 0.0200 84 消毒液 (次氯酸钠) 0.4 5 0.0800 二甲苯 0.01 10 0.0010 0.2334 合计 根据《建设项目环境风险评价技术导则》(HJ169-2018),当厂区存在 多种危险物质时,物质总量与临界量的比值按下式计算: Q=q1/Q1+q2/Q2+……+qn/Qn 式中:Q—危险物质数量与临界量比值 q1,q1,…,qn—每种危险物质的最大存在总量,t; Q1,Q1,…,Qn—每种危险物质的临界量,t 当 Q<1 时,该项目环境风险潜势为Ⅰ 经计算可知,本项目 Q=0.2334 <1,则本项目环境风险潜势为Ⅰ。 5.4.1.3 评价工作等级划分 根据《建设项目环境风险评价技术导则》(HJ169-2018),本项目风险 评价工作等级为简单分析,本项目环境风险评价等级划分见表 5-31。 表 5-31 本项目环境风险评价工作等级划分 环境风险潜势 Ⅳ、Ⅳ+ Ⅲ Ⅱ Ⅰ 评价工作等级 一 二 三 简单分析a a是相对于详细评价工作内容而言,在描述危险物质、环境影响途径、环境危害后果、风险防 范措施等方面给出定性的说明。见附录A。 根据表 5-31,本项目环境风险只需进行简单分析。 5.4.2 环境风险识别及分析 161 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 根据分析,项目存在的环境风险主要为液氧罐过压爆炸、危险废物泄漏风 险、污水站次氯酸钠、化验室化学试剂泄漏风险、污水处理设施事故性超标排 放、 本项目污水处理设施非正常排放会对郸城县第三污水处理厂的进水水质造 成一定影响,但因水量较小,不会对污水处理厂的运行造成较大影响,非正常 排放的废水进入郸城县第三污水处理厂处理后达标排放,不会对地表水环境造 成影响;医疗废物专人负责,严格按《医疗废物集中处置技术规范(试行)》 相关要求进行管理;次氯酸钠、化学试剂严格按化学品储存要求存储于加药间, 专人负责,储存量较小,泄漏风险较小。 类比同类医院,医疗固废和化学试剂通过管理措施的落实,在正常管理情 况下可得到有效控制,事故发生概率很小。相对而言,项目最大可信事故为废 水事故排放对地表水造成的影响。 5.4.3 环境风险分析及防范措施 5.4.3.1 液氧罐过压爆炸事故分析及防范措施 (1)液氧罐过压爆炸风险防范措施: 液氧罐远离热源,使用液氧罐时,严格遵守操作规程,开关阀门不要过急、 过快,不免产生摩擦热和静电火花;液氧罐内气体不能用尽、应留有余压,如 感到气体不纯,应考虑形成爆鸣性气体的可能性,对液氧罐内的气体采取正确 的检测方法进行鉴别;在充装、使用液氧罐前,要仔细检查自己的双手、手套、 工具、减压阀等有无沾染油脂,用于液氧罐的汇流排管道及其密封圈,第一次 使用前均须认真脱脂,且不得采用可燃的密封圈,液氧罐的连接管必须采用高 压金属软管;要保证液氧罐强度,购买选用有制造资质的单位生产的合格产品, 并按相关检验规定要求,每 3 年检验 1 次,检验时做气密性实验;液氧罐在充 装、运输、储存、使用过程中,严禁敲击、碰撞;液氧罐在储存、使用等过程 中不得靠近热源,夏季要防止;使用人员遇到开启时;漏气的液氧罐,应停止 162 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 使用,连罐带气送回生产厂更换,由专业检验人员维修,不得自行维修,以免 发生阀芯飞出伤人或火灾等安全事故。 (2)柴油泄漏风险措施: A 储存注意事项:①备用发电机仅停电时使用,柴油罐的最大储存量为 1t , 在柴油发电机房储油间(地上一层配电用房处),设置防火安全设施,并严格 《危险化学品安全管理条例》 (2002 年,国务院第 344 号) 的规定进行运输、 储存和使用,储存间内按有关规范要求配置干粉泡沫化学灭火器。 ②在柴油储存间设置应急桶,并设置围堰。 B 操作注意事项:专人负责柴油罐的安全管理工作,落实安全管理制度, 专职人员要准确、完整地做好进出油的明细账,定期盘点储油量,发现不足及 时补给;严禁在油罐处吸烟和使用明火;油罐周围严禁堆放各种易燃物品;油 罐必须做好保温、降温工作,防止爆炸事故;定期检查油罐,对存在安全隐患 的限期整改。 C 消防灭火方法:消防人员须佩戴防毒面具、穿全身消防服,在上风向灭 火。尽可能将容 器从火场移至空旷处。喷水保持火场容器冷却,直至灭火结束。 处在火场中的容器若已 变色或从安全泄压装置中产生声音,必须马上撤离。灭 火剂:雾状水、泡沫、干粉、二 氧化碳、砂土。 D 应急措施:迅速撤离泄漏污染区人员至安全区,并进行隔离,严格限制 出入。切断火源。建议 应急处理人员戴自给正压式呼吸器,穿一般作业工作服。 尽可能切断泄漏源。防止流入 下水道、排洪沟等限制性空间。小量泄漏:用活 性炭或其它惰性材料吸收。大量泄漏: 构筑围堤或挖坑收容。用泵转移至槽车 或专用收集器内,回收或运至废物处理场所处置。 E 急救措施: 皮肤接触:立即脱去污染衣着,用肥皂水和清水彻底冲洗皮肤。就医。 眼睛接触:提起眼睑,用流动清水或生理盐水冲洗。就医。 163 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 吸入:迅速脱离现场至空气新鲜处。保持呼吸道通畅。如呼吸困难,给输 氧。如呼吸停止,立即进行人工呼吸。就医。 食入:尽快彻底洗胃、就医。 (3)污水站次氯酸钠泄漏风险措施: 次氯酸钠储存注意事项:储存于阴凉、通风的库房。远离火种、热源库温 不宜超过 30℃。应与酸类分开存放,切忌混储。储区应备有泄漏应急处理设备 和合适的收容材料。 次氯酸钠操作注意事项:密闭操作,全面通风。操作人员必须经过专门培 训,严格遵守操作规程。建议操作人员佩戴直接式防毒面具(半面),戴化学 安全防护眼镜,防工作服,戴橡胶手套·防蒸气泄漏到工作场所气中。避免与 酸类接触。搬运时要轻装轻卸,防止包装及容器损坏。配备泄漏应急处理设备。 倒空的容器可能残留有害物。 次氯酸钠不燃,但为氧化剂可助燃.,受高热分解产生有毒的腐蚀性烟气, 具有腐蚀性。发生泄漏时迅速撤离泄漏污染区人员至安全区,并进行隔离,严 格限制出入。建议应急处理人员戴自给正压式呼吸器,穿防酸碱工作服。不要 直接接触泄漏物。尽可能切断泄漏源。小量泄漏:用砂土、石或其它情性材料 吸收。大量泄漏:构筑围提或挖坑收容。用泡沫覆盖,降低蒸气灾害。用泵转 移至槽车或专用收集器内,回收或运至废物处理场所处置。 急救措施: 皮肤接触:脱去污染的衣着,用大量流动清水冲洗。 眼晴接触:提起眼脸,用流动清水或生理盐水冲洗。就医。 吸入:迅速脱离现场至空气新鲜处。保持呼吸道通畅。如呼吸困难,给输 氧。如呼吸停止,立即进行人工呼吸。就医。 食入:饮足量温水,催吐。就医 灭火方法: 采用雾状水、二氧化碳、砂土灭火。 (4)化验室化学试剂 164 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 ①风险分析 各药品库房及各化验室内化学试剂存储量较小,均为小包装瓶装或桶装。 化学试剂 泄漏量较少,可及时收集全部泄漏物,并转移至安全空置的容器内。 少量易挥发性有机 物通过表面扩散到大气环境,但因短时间即可处理完泄漏事 故,而且所使用大部分的化 学试剂毒性较低,产生严重环境污染事故的可能性 很小,只是对试剂间周围近距离范围 的环境空气有一定影响。 ②风险防范措施 A 、严格按照相关设计规范和要求落实防护设施,加强监督管理,消除事 故隐患; B 、药品库控制化学试剂储存量,加强周转流通, 以降低事故发生的强度, 减少事 故排放源强; C 、在搬运化学试剂前,预先做好工作,了解物品的性质,检查装卸运输 工具,如 工具被易燃物,有机物、酸、碱等污染,必须清洗后方可使用; D 、操作人员应该根据不同的物品的危险特性,分别配备相应的防护用具。 包括工 作服、手套、防毒面具、防护眼镜等; E 、装卸操作时,不得饮酒、吸烟,工作完毕后根据工作情况和危险品的 性质,及 时清洗手、脸、漱口或者淋浴。保持现场空气的畅通,如果发现恶心、 头晕等中毒现象, 应及时送医,做好通风隔离措施; F 、药品库必须考虑化学试剂储存的环境风险防范措施,通过消防、安全 验收,配 备专业技术人员负责管理,不同化学品分类存放,禁忌混合存放。易 燃物与毒害物应分 割储存,有不同的消防措施; G 、涉及到化学试剂使用的实验室地面采用防滑、防渗硬化处理。试验区 域设置地 沟、地漏 (每个实验室均设置地漏,具有清洗功能的房间设置地沟和 地漏) ,即使发生 液体泄漏,废水可经收集处理后排入污水处理系统; H 、配备备用的容器,以防液体化学品发生泄漏时,可以及时安全转移; 165 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 I 、化学危险品的养护:化学危险品储存时,应严格检验物品质量、数量、 包装情 况、有无泄漏;定期检查,发现其质量变化、包装破损等情况时,及时 处理。 J 、突发事故时的应急处理措施:迅速撤离泄漏污染区人员至安全区,并 进行隔离, 严格限制出入。建议应急处理人员戴自给正压式呼吸器,穿防酸碱 工作服。不要直接接 触泄漏物。尽可能切断泄漏源。小量泄漏:用砂土、蛭石 或其它惰性材料吸附吸收。也 可以用大量水冲洗,洗水稀释后放入废水系统。 大量泄漏:构筑围堤或挖坑收容。用耐 酸碱泵转移至槽车或专用收集器内,回 收或运至废物处理场所处置。 5.4.3.2 危险废物风险及防范措施 本项目产生的医疗固体废物主要为临床和手术室产生的损伤性、感染性及 病理性等医疗废物及门诊楼、病房楼产生的生活垃圾,均属于危险固废,不得 随意存放及丢弃,应根据《医疗废物集中处置技术规范(试行)》相关要求, 设置专门的医疗废物暂存间,并专人负责。 医疗废物在暂存过程中,医疗废物暂存间每天消毒一次,防止医疗废物腐 败散发恶臭,做到日产日清。如确实不能做到日产日清,且当地最高气温高于 25℃时,应将医疗废物低温暂时储存,储存温度不高于 20℃,时间最长不超过 48 小时。医疗废物在收集和运送至医院现有医疗暂存库房过程中应满足以下要 求:医疗废物分类包装,置于专用暂时贮存箱中;箱应密闭并采取安全措施, 如加锁和固定装置,做到无关人员不可移动,外部应按照《环境保护图形标 志——固体废物贮存(处置)场》(GB 15562.2-1995)修改单和《医疗废物集 中处置技术规范(试行)》附录 A 要求设置警示标识。 为保证医疗废物的妥善贮存,医院拟建 50m3 的危险废物暂存间,并有防雨 淋、防扬散措施,同时符合消防安全要求。收集到的医疗废物通过医院专用手 推车运至医疗废物暂存间存放,由有资质单位定时拉运,进行集中处理。 166 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 医疗废物在运输途中如果出现事故,将导致医疗废物大量溢出、散落,对 周围环境及人群造成较大影响,因此,评价建议医院和医疗废物处置单位联合 成立专门的应急小组,合理优化选择医疗废物运输路线及运输过程中的安全规 范,降低医疗废物运输过程中的风险事故概率。 5.4.3.3 污水处理站事故排放分析及防范措施 本项目废水包括食堂废水、病区化验废水,门诊楼及病房楼产生的医疗废 水及空调冷凝水,后勤办公综合楼、宿舍产生的普通生活污水。病区食堂废水 经油水分离器处理、病区化验室废水经酸碱中和处理后经过臭氧预消毒,然后 与化粪池+臭氧预消毒处理过的病区其他医疗废水(门诊废水、 住院病房废水、 医务人员废水、空调冷凝水、蒸汽消毒废水)、隔油预处理过的非病区普通食 堂废水、普通化粪池处理过的非病区其他生活污水(后勤办公人员废水、宿舍 楼、空调冷凝水)一起排入医院综合污水处理站进一步处理达标后,汇入郸城 县第三污水处理厂。消毒蒸汽纯水制备浓水和非病区空调冷凝水作为清排水直 接排入医院总排口。 在污水站正常运行的情况下,本项目废水经过处理出水水质能够达到《医 疗机构水污染物排放标准》(GB18466-2005)表 1 传染病、结核病医疗机构水 污染物排放浓度、最高允许排放负荷标准要求和郸城县第三污水处理厂进水水 质要求。污水处理站出现故障时, 医疗废水排入应急事故池暂存, 不允许未 经处理直接外排。 本项目废水应急池容量约 600m3。 废水处理过程中的事故因素包括两方面: ①操作不当或处理设施失灵,废水不能达标而直接排放。医院污水可沾染 病人的血、尿、便,或受到粪便、传染性细菌和病毒等病原性微生物污染,具 有传染性,可以诱发疾病或造成伤害;含有酸、碱、COD、BOD5、SS 和动植 物油等有毒、有害物质和多种致病菌、病毒和寄生虫卵,它们在环境中具有一 定的适应力,有的甚至在污水中存活较长,危害性较大:不经有效处理会成为 167 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 一条疫病扩散的重要途径和严重污染环境,危害人体健康并对环境有长远影响, 排放的废水将会导致环境污染事故; ②虽然废水处理设施运行正常,但未能较好的控制加药量,使过多的余氯 排放环境中,给周围人群的健康带来一定的威胁,并影响环境质量。 如果医院污水站出现异常,将导致大量的活体病原微生物进入市政管网, 通过城市污水处理厂,最终将进入地表水体,虽然城市污水厂出水也设置有消 毒设施,但此种情况已构成对周围环境的潜在危害。 1、污水事故排放对郸城县第三污水处理厂的影响 项目废水事故排放会加大污染负荷,特别是大肠杆菌排放量的增加,对郸 城县第三污水处理厂的水质会造成一定的冲击,对污水处理厂的处理效果也有 一定的影响。 2、污水事故排放对洺河水质的影响 项目废水事故排放时,COD、氨氮等污染物经郸城县第三污水处理厂处理 对洺河水质影响不大,但病菌等特征污染物的影响较大。因此为减轻洺河污染 负荷,应避免出现事故排放,为此,评价建议: (1)污水处理站必须制定严格的操作规程和管理制度; (2)应对次氯酸钠水射器和其他处理设施定期进行维护、检修、保养,对 备用设备应及时检修维护,发现问题及时解决,以防止电器及设备故障发生, 确保污水处理处理站稳定运行; (3)加强操作人员的职业道德教育和职业技能培训,使操作人员均持证上 岗,具有高度的责任心和熟练的操作技能,能根据进水的水质、水量变化及时 调整操作工艺,避免操作失误造成工艺系统的紊乱和破坏。 (4)要求污水处理站加强日常的运行管理,加强对操作人员的岗位培训, 确保污水稳定达标排放,杜绝事故性排放,建立健全应急预案体系、环保管理 机制和各项环保规章制度,落实岗位环保责任制,加强环境风险防范工作,防 止事故排放导致环境问题。 168 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 通过上述预防措施,评价认为能够最大限度的减少污水处理站运行期风险 事故的发生,确保污水处理站正常和稳定运行,使处理后废水达标排放。 3、应急池 根据《医院污水处理工程技术规范》 (HJ2029-2013) 的规定,“传染病 医院污水处理 工程应急事故容积不小于日排放量的 100% ,非传染病医院 污水处理工程应急事故池容积不 小于日排放量的 30% ”。本项目医疗废污 水排放量约为 588.99m 3 /d,为传染病医院,污水处理 系统的事故池按日排 放水量的 100%考虑时 ,废水处理系统事故应急池容积不得少于 588.99m 3 。 根据医院设计,本项目紧临污水处理站东侧建设应急事故池 1 处,容积为 600m3 , 应 急 事 故 池 设 置 合 理 , 满 足 《 医 院 污 水 处 理 工 程 技 术 规 范 》 (HJ2029-2013) 的要求。 污水处理站内的设备非正常运行时, 可能会使处理出水水质不合格, 将 采用回流再处理的方法解决, 即自动监测仪表发现废水不合格时,不合格的处 理水自动回流,重新进行处理。 污水处理站内的处理工艺、加药系统和流量控 制系统均安装在线自动化检测仪器, 发生故障时, 可及时报警并停止向外排 放废水,同时可将废水暂存于事故池内(600m3)。杜绝事故废水外排。 5.4.4 风险事故应急预案 制定风险应急预案的目的是为了在发生风险事故时,能够以最快速度发挥 最大的能效,有序的实施救援,尽快控制事态的发展,降低事故造成的危害, 减少事故造成的损失。应急预案应以“预防为主,防救结合”为原则。根据本次 工程可能发生的风险事故提出相应的应急预案。应急预案内容详见表 5-32。 表 5-32 突发事故应急预案主要内容 序号 项目 内容及要求 1 总则 涉及物料性质及可能发生的突发事故 2 危险源概况 3 应急计划区 氧气罐过压爆炸、柴油泄漏、污水站次氯酸钠泄漏、化验室用化学 试剂泄漏、医疗废物泄漏、医疗废水事故排放 液氧站、柴油发电机房储油间、污水站储药间、医疗废物暂存库 房、医疗废物运输路线沿线区域 169 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 医院:指挥机构-由副院长任总指挥,主管的副总经理任副总指 挥,负责救援工作的组织和指挥,应急救援指挥部设在院办公室。 4 应急组织 救援队伍-包括通信联络队、治安队、抢险抢修队、医疗救护队负 责事故控制、救援、善后处理。 地区:地区指挥部-负责医院附近地区指挥、救援、管制、疏散。 专业救援队伍-负责对医院救援队伍的支援。 应急状态分类 5 及应急响应程 规定事故的级别及相应的应急分类响应程序 序 6 7 8 应急设施、设 口罩、隔离服等 备与材料 报警与通讯联 事故发生后及时向郸城县及医疗废物运输沿线的环保、卫生、消防 络 等领导机关报告事故情况 事故后评估 针对事故发生区域环境影响和破坏进行评估 事故现场:控制事故、防止扩大、蔓延及连锁反应,清除现场泄漏 9 应急防护措施 物,降低危害相应的设施器材配置。邻近区域:控制安全区域,控 制和消除污染措施及相应设备。 10 应急状态终止 规定应急状态终止程序。事故现场善后处理,恢复措施。邻近区域 与恢复措施 解除事故警戒及善后恢复措施。 培训—指挥领导小组负责组织,培训部实施培训工作,根据应急预 案实施情况每年制定相应培训计划,采取多种形式对应急人员进行 11 人员培训与演 练 应急知识、技能培训;培训对象主要为员工和专业救援人员;主要 培训内容为紧急应变处理和急救;进行安全、急救、紧急事故等培 训。演练—每年组织一次人员疏散、急救、消防演习,其他应急功 能依实际需求不定期开展演习,并做好记录和评价,对应急演习进 行总结和追踪记录。 12 附件 与应急事故有关的多种附件材料构成。 5.4.5 风险评价结论 本项目涉及的风险源主要为液氧罐过压爆炸事故、柴油泄漏引起的火灾事 故、污水站次氯酸钠泄漏事故、化验用化学试剂泄漏、医院污水事故排放、医 疗废物泄漏,评价认为,在认真落实评价提出的各项风险防范措施及应急预案 的基础上,本项目风险发生概率较低,风险水平可以接受。根据以上分析内容, 本项目环境风险简单分析内容表详见表 5-33。 表 5-33 建设项目环境风险简单分析内容表 建设项目 郸城县人民医院西南院区新建项目 170 郸城县人民医院西南院区新建项目环境影响报告书 第五章环境影响预测与评价 名称 建设地点 地理坐标 郸城县科技大道北、公园西路西侧地块 115.14459642 经度 纬度 33.62930858 主要危险物质 主要危险物质:液氧、柴油、次氯酸钠、化学试剂;分布:液氧站、柴油 及分布 环境影响途径 及危害后果 罐、污水站加药间、化验室及药品仓库 液氧罐过压爆炸引起的火灾事故,柴油泄漏引起的火灾事故,污水站次氯 酸钠泄漏、化学试剂泄漏、医疗废物泄漏对地下水产生污染影响,污水处 理站事故超标排放会对郸城县第三污水处理厂产生影响。 1 、严格管理化学品,对化学品做到定期检查,储存间内按要求设置消防设 施。 2 、液氧站严禁存放其他可燃物品,设置警示标牌,规范管理,落实防 火、防爆设计要求,配备足够的消防器材。 3 、发电机房储油间柴油罐四周设防渗围堰,地面采取重点防渗措施,并配 风险防范 备泄漏防范 应急物质。 措施要求 4 、加强污水处理站管理,污水处理站定期检修,设置应急事故池,防止事 故废 水排放。 5 、做好医疗垃圾暂存和运出处理的管理工作,严格医疗垃圾的“日产日清” 制 度,暂存间每天专人负责清扫、消毒工作。 6 、严格执行环评及相关法律法规要求,定期开展设备维护,保证其有效运 行和 去除效率;制定环境风险应急预案。 填表说明 根据项目环境风险潜势初判结果,本项目环境风险潜势为I,评价工作可进 行简单分析 171 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 第六章环境保护措施及其可行性论证 6.1.施工期污染防治措施 6.1.1.废气污染防治措施 扬尘污染是施工期间重要的污染因素,项目在地下挖掘过程以及建设期间, 不可避免地会产生一些地面扬尘,这些扬尘尽管是短期行为,但会对附近区域 带来不利的影响,所以在施工期间,应采取积极的措施来尽量减少扬尘的产生, 如喷水,保持湿润,及时外运等。施工过程应严格遵守《郸城县污染防治攻坚 战领导小组办公室关于印发郸城县 2022 年大气、水、土壤污染防治攻坚战及农 业农村污染治理攻坚战实施方案的通知》(郸环攻坚办〔2022〕7 号)的相关 规定;在风力大于 4 级的情况下应停止土方作业,同时作业处应覆以防尘网。 施工单位应负责实施下列减缓措施以防止扬尘污染: (1)在建筑物建设中,施工单位必须实行封闭式施工,使用围护材料以防 止扬尘,设置高度 2m 以上的围挡,围挡之间应无缝隙。应在工地建筑结构脚 手架外侧设置有效抑尘的密目防护网或防尘布。 图 6-1 防尘网示意图 (2)运载水泥、建筑材料以及建筑垃圾的车辆要遮雨布遮盖或使用密闭运 输车减少散落,施工场地需设置洗车平台,车辆驶出装、卸场地前用水将车厢 和轮胎冲洗干净;运输车辆驶出施工现场前要将车轮和槽帮冲洗干净,确保车 辆不带泥土驶离工地; 172 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 施工场地内运输通道及时清扫冲洗,以减少汽车行驶扬尘;运输车辆行使 路线应避免穿越城市中心区,尽量避开居民点和环境敏感点。严禁使用敞口运 输车运输施工垃圾。杜绝超高、超载和沿路撒落等违法运输行为。 图 6-2 车斗防尘布示意图 (3)各施工阶段应有专职环境保护管理人员,其职责是指导和管理施工现 场的建筑垃圾、建筑材料的处置、清运、堆放,场地恢复和硬化,清除进出施 工现场道路上的泥土、弃料以及轮胎上的泥土,防止二次扬尘污染。 (4)项目施工材料的临时堆放点应尽可能设置在场地中间,以增大与周边 环境敏感点之间的距离,减小粉尘对周围环境敏感点的影响。 (5)合理安排施工运输工作,对于施工作业中的大型构件和大量物资的运 输,应尽量避开交通高峰期,以缓解交通压力。同时,施工单位应与交通管理 部门协调一致,采取相应的措施,做好施工现场的交通疏导,避免压车和交通 阻塞,最大限度的控制汽车尾气的排放。 (6)施工作业区应配备专人负责,做到科学管理、文明施工。在基础施工 期间,应尽可能采取措施提高工程进度,并将土石方及时外运到当地政府指定 地点,缩短堆放的危害周期。 (7)运砂石、建筑材料时不宜装载过满,同时要采取相应的遮盖、封闭措 施(如用苫布)。对不慎洒落的沙土和建筑材料,应对地面进行清理。 173 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 (8)对作业面和临时土堆应适当地洒水,使其保持一定的湿度,减小起尘 量;项目施工现场应加大洒水量及洒水频次,采取措施减少施工扬尘的产生; 施工便道应进行夯实硬化处理,进出车辆应经过过滤池,减少起尘量。 6.1.2.废水防治措施 施工期废水主要有施工废水和生活污水,施工单位将采取下列减缓措施, 以使施工活动对水环境的影响减少到最小限度。 (1)严禁施工废水乱排、乱流。 (2)施工生产废水经隔油沉淀池 20m3 处理后可作为生产用水用于混凝土 建筑的养护、运输车辆冲洗,场地冲洗以及绿化,不外排。 (3)施工人员产生的生活污水设置临时隔油池、临时化粪池处理,处理后 满足 GB8978-1996《污水综合排放标准》表 4 三级标准后排入周边市政污水管 网。 (4)在施工场地临时排水通道处禁止堆放建筑材料和建筑垃圾,并注意清 理淤泥,防止阻塞排水通道。 (5)对于基坑开挖后汇集的雨水,基坑内应每隔 50m 左右设一集水井, 采用离心泵抽排,也可作为施工期道路浇洒、车辆清洗以及抑尘用水。若基坑 发生渗水现象,建设单位应及时进行封堵,渗水可通过离心泵抽排。 (6)施工单位除加强对施工废水和生活污水的排放管理外,应对员工进行 基本环保知识培训,提高环保意识和责任。 6.1.3.噪声污染防治措施 本项目在工程施工期间建筑施工噪声对周围声环境质量有一定影响,根据 《中华人民共和国环境噪声污染防治法》第 28 条规定“在城市市区内向周围生 活环境排放建筑施工噪声时,应当符合国家规定的建筑施工场界环境噪声排放 标准”,尽管施工期产生噪声干扰无法完全避免,但还是可以使周围环境受到 的噪声影响降低到一定程度。 174 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 建筑施工由于各阶段使用的机械设备组合情况不同,所以噪声辐射影响的 程度也不尽相同。在主体施工阶段,噪声特点是持续时间长,强度高。相比之 下,装饰期间的噪声相对较弱,主要是一些噪声较强的木工机械可搬入已建成 的主体建筑内进行操作。由于建筑施工是在露天作业,流动性和间歇性较强, 对各生产环节中的噪声治理具有一定难度,下面结合施工特点,对一些重点噪 声设备和声源,提出一些治理措施: (1)采用局部吸声、隔声降噪技术 对各施工环节中噪声较为突出且又难以对声源进行降噪可能的设备装置, 应采取临时围障措施,围障最好敷以吸声材料,以此达到降噪效果。 (2)对主要发声设备电锯的噪声治理措施 施工现场的电锯在运转时,空载噪声为 98-100dB(A),负载时噪声为 100105dB(A)。在锯木料时,锯齿受到反作用力而产生声波;另外当锯片压盘垂直 度不良时,磨刃齿形不匀,也会造成锯片动平衡失调及轴承磨损,从而加剧振 动噪声,此外还有锯片高速旋转时产生的动力性噪声。根据上述分析,建议采 取以下治理措施: a、取消滑架上的集屑斗,降低旋转噪声。 b、在工作平台上粘附泡沫塑料,使工作台起到一定的吸声作用。 c、在机腔内四壁和轴承座平面上贴附吸声材料,使机内变成多层阻性消声 器。 d、在锯片工作部分,在距平台高 100mm 处增加吸尘消声器。 e、在操作过程中,应随时注意检查锯片压盘的垂直度和锯齿形状的均匀度, 避免失重,减少振动负荷。 采取以上措施,使电锯空载噪声降至 84dB(A),负载噪声降至 86dB(A), 可减轻对操作人员及外界环境的影响。此外,在施工过程中,噪声源应尽量设 置在远离居民区的地方,减少扰民现象的发生。 除此之外,施工期还应该注意以下几点: 175 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 (1)合理布置噪声源设备:在不影响施工情况下将噪声设备尽量不集中安 排,并将其远离周边敏感点较远处,为保障居民区有一个良好的生活环境。 (2)在施工过程中,采用商品混凝土和成品大型建筑构件,应在施工现场 外预制,然后运到施工现场再行安装。 (3)为避免本项目施工对敏感点产生影响,本评价提出合理安排施工时间, 夜间(22:00~6:00)禁止施工。对于确需夜间施工的施工活动,施工单位必须事 前报经主管部门批准,同时执行建筑施工噪声申报登记制度,在工程开工 15 日 前填写《建筑施工场地噪声管理审批表》,向当地生态环境保护主管部门申报。 并于施工前两天公告附近居民。做好与周边单位、居民的沟通工作,如有发出 高分贝噪声的施工内容或必须进行夜间施工时,施工单位在施工前,应当主动 地将发出高分贝噪声的施工及夜间施工的时间、内容、降噪措施以及应急情况 处置等情况与施工现场周边的企事业单位、学校、商店以及居委会进行沟通, 并取得这些单位和市民的谅解;同时,将上述内容以“告示”形式张贴在施工 现场周围,接受社会的监督。 (4)运输车辆进出施工现场控制或禁止鸣喇叭,减少交通噪声。减少或尽 量避免施工车辆停驻在区域道路。 (5)制定施工噪声控制备用应急方案,重视噪声源头的治理工作。当常规 噪声控制措施不能满足要求,出现噪声扰民情况,应及时对产生噪声的设备和 施工工艺停止施工,并检查噪声防治措施的可靠性。 总之,建设单位必须全面落实上述要求,不得对周围居民产生扰民现象。 施工期加强施工管理后,施工噪声对周围环境的影响可控制至最低程度,影响 随着施工期的结束而结束。 6.1.4.固体废物污染防治措施 施工期固体废物是在主体结构阶段、装修阶段产生的施工垃圾,主要有建 筑材料边角料和施工人员生活垃圾。这些废料及建筑垃圾在堆放和运输过程中 对周围环境有一定影响,因此,施工期建筑垃圾可委托有资质专业的建筑垃圾 176 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 清运单位将固体废物运至指定的垃圾填埋场进行填埋处置。施工期生活垃圾集 中存放委托环卫清运、卫生填埋处理。 针对施工期施工垃圾应从源头上进行控制,体现在施工管理、材料选购、 去向控制等方面,特别应强调以下几点: (1)应有专人负责施工场地和施工便道的洒水工作,洒水频率决定于天气 状况,以防止二次扬尘污染。 (2)建设单位在工程招投标或者直接发包时,应当在招标文件或者承发包 合同中明确施工单位在施工现场对建筑垃圾管理的具体要求和相关措施,并监 督施工单位按照规定文明施工,落实冲洗保洁措施。建设单位或者施工单位应 当在工程开工前向项目所在地的区城市管理行政部门申请核发建筑垃圾处置证。 申请单位应当符合下列条件:①已取得施工许可证或者其他许可文件;②有建 筑垃圾处置方案及相关资料;③具备文明施工的开工条件;④有与取得建筑垃 圾运输服务许可证的运输单位签订的运输处置合同;⑤有消纳处置合同,合同 确定的消纳场所符合有关规定”。 (3)各施工阶段应有专职环境保护管理人员,其职责是指导和管理施工现 场的工程弃土、建筑垃圾、建筑材料的处置、清运、堆放,场地恢复和硬化, 清除进出施工现场道路上的泥土、弃料以及轮胎上的泥土,防止二次扬尘污染。 (4)施工前应向当地环保有关部门(环保监察部门)申报,办理相关的环 保管理手续,根据环保有关部门的要求,在施工过程中应向环保有关部门通报 施工情况。 6.1.5.文明施工 文明施工,是指在工程建设和建筑物及构筑物拆除等活动中,按照规定采 取措施,改善施工现场作业环境,维护施工人员身体健康,减少对周边环境及 市容环境卫生影响的施工活动。建设单位应做好文明施工工作。主要要求为: (1)建设工程文明施工由建设单位负总责。建设单位应当在合同中明确勘 察、施工、监理等单位的文明施工的相关责任,并为前述单位进行文明施工创 177 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 造条件。有多个施工单位的施工现场,建设单位应当有效协调文明施工的管理 工作。 (2)施工单位对文明施工具体负责。建设工程实行施工总承包的,由总承 包单位对文明施工全面负责,分包单位应当服从总承包单位的管理,对总承包 单位负责。施工单位应当编制文明施工方案并组织实施,建立文明施工责任制, 明确责任人。施工单位项目经理是工程项目文明施工的第一责任人,对施工现 场文明施工负直接责任。 (3)建设工程开工前,施工单位应当组织完成施工现场的文明施工设施建 设并将文明施工方案上报建设行政部门,经建设行政部门现场勘验和审查,符 合文明施工标准的,方可开工建设。 (4)施工单位应当按照要求在施工现场醒目处设置消防保卫、安全生产、 环境保护、文明施工、工程概况和施工现场总平面图等标牌,标牌内容应当全 面、详细、准确。 (5)建设工地办公区、作业区、生活区应当合理规划,分开设置。施工现 场应当设置符合消防要求的进出道口,大门要采用封闭门扇。进出道口和工地 内道路、材料堆放场地应当进行硬化处理,并能满足载重车辆通行要求。 (6)建设工程施工现场实行封闭式管理,应当设置固定围挡,并提倡采用 新型环保材料。围挡应当定期检查、清洗和刷新,保证其牢固、整洁、美观。 (7)建筑工程施工至 2 层以上(含 2 层)时,应当采用防护网进行封闭, 封闭应当高于作业面且同步进行。采用提升或者滑模板等工艺施工的,可以按 照相关规范要求进行封闭。防护网应当整洁、牢固、无破损。 (8)鼓励采用节能环保的先进工艺和设备施工,减少对环境的破坏。施工 现场推广使用视频监控系统。 施工现场应当采取下列措施防止环境污染: 178 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 ①施工进出道口应当设置符合要求的车辆冲洗保洁设施。进出工地的车辆 应当经冲洗保洁设施处置干净后,方可驶离工地,禁止车辆带泥及渣土上路。 施工现场应当配置专职保洁员,负责工地和进出道口的保洁。 ②施工产生的建筑垃圾和其他生活垃圾应当及时清运。施工单位应当将建 筑垃圾交由具有相应资质的承运单位,按照核准的数量和运输线路、时间、倾 倒地点进行处置。运输建筑材料和建筑垃圾时,必须采用密封车辆运输,禁止 沿途漏撒。 ③粉灰质建筑材料应当入库存放。现场拌和粉灰质建筑材料,应当采取有 效措施,防止扬尘。中心城区建设工地禁止现场搅拌混凝土和砂浆。 ④施工现场应当定期洒水压尘。裸露泥土在 1 个月以上的,应当采取简易 植物绿化覆盖;不足 1 个月的,可以采取防尘网(布)覆盖。 ⑤建筑物、构筑物内的建筑垃圾应当采用相应容器或者管道清运,禁止凌 空抛洒。 ⑥禁止在施工现场焚烧建筑垃圾、生活垃圾以及其他产生有毒有害气体的 物质。 (9)施工现场应当设置沉淀池、隔油池等对施工污水、生活污水进行处理, 不得随意排放;禁止向饮用水源及河道、湖泊等水域排放污水。 (10)施工单位应当对产生噪声、振动的施工设备和机械采取消声、减振、 降噪等措施。运输车辆进出工地禁止鸣笛,装卸材料应当做到轻拿轻放。除抢 修、抢险外,禁止夜间(22 时至次日 6 时)在居民区、文教区、疗养区和其他 需要安静环境的地区进行有噪声污染的施工作业。由于生产工艺上的连续性或 者其他特殊原因,确需连续施工的,施工单位应当向当地审批部门办理审批手 续,并通告附近居民。 6.2.运营期污染防治措施 6.2.1 废水治理措施评价 179 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 6.2.1.1 医院污水特点 本项目废水包括食堂废水、病区化验废水,门诊楼及病房楼产生的医疗废 水及空调冷凝水,后勤办公综合楼、宿舍产生的普通生活污水。 食堂废水污染物主要是动植物油;门诊楼及病房楼产生的医疗废水主要为 一些传染病人及医务人员产生的废水,需要经过专用化粪池+臭氧预消毒池处理 后进入污水处理站进行处理;化验废水主要为酸碱废水,利用玻璃容器储存至 一定量后加入氢氧化钠或盐酸等进行中和处理,控制pH在7-8之间,经中和处理 后进入污水处理站处理。 病区食堂废水经油水分离器处理、病区化验室废水经酸碱中和处理后经过 臭氧预消毒,然后与化粪池+臭氧预消毒处理过的病区其他医疗废水(门诊废 水、 住院病房废水、 医务人员废水、空调冷凝水、蒸汽消毒废水)、隔油预 处理过的非病区普通食堂废水、普通化粪池处理过的非病区其他生活污水(后 勤办公人员废水、宿舍楼、空调冷凝水)一起排入医院综合污水处理站进一步 处理达标后,汇入郸城县第三污水处理厂。消毒蒸汽纯水制备浓水和非病区空 调冷凝水作为清排水直接排入医院总排口。 6.2.1.2 医院污水工艺可行性分析 根据《医院污水处理工程技术规范》(HJ2029-2013)医院性质分类,传染 病医院污水一般采用预消毒+二级处理+(深度处理)+消毒工艺。根据《医院 污水处理工程技术规范》(HJ2029-2013),医院污水生物处理工艺主要有活性 污泥法、生物接触氧化法、膜生物反应器、曝气生物滤池和简易生化处理等。 不同工艺的特点、适用范围与投资水平见表 6-1。 表 6-1 工艺类型 活性 生化处 污泥 理 法 不同生物处理工艺的综合比较 优点 缺点 适用范围 基建 投资 运行稳定性差,易发 对不同性质的污水适应 生污泥膨胀和污泥流 水量较大的医院污水 性强。 失,分离效果不够理 处理工程 较低 想 生物 抗冲击负荷能力高,运 部分脱落生物膜造成 中小规模医院污水处 180 中 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 接触 行稳定;容积负荷高, 出水中的悬浮固体浓 理工程。适用于场地 氧化 占地面积小;污泥产量 池 度稍高。 小、水量小、水质波 较低;无需污泥回流, 动较大和微生物不易 运行管理简单。 培养等情况。 作为对于边远山区、 简易 生化 造价低,动力消耗低, 处理 管理简单。 出水COD、BOD等理 化指标不能保证 达标。 工艺 经济欠发达地区医院 污水处理的过渡措 施,逐步实现二级处 低 理或加强处理效果的 一级处理。 抗冲击负荷能力强,出 膜-生 水水质优质稳定,有效 气水比高,膜需进行 小规模医院污水处理 物反 去除SS和病原体;占地 反洗,能耗及运行费 工程;医院面积小, 应器 面积小;剩余污泥产量 用高。 高 水质要求高等情况。 低甚至无。 深度处 出水水质好;运行可靠 理 曝气 生物 滤池 性高,抗冲击负荷能力 强;无污泥膨胀问题; 容积负荷高且省去二沉 池和污泥回流,占地面 需反冲洗,运行方式 比较复杂;反冲水 下小规模医院污水处 量较大。 理工程。 较高 积小。 根据综合考虑,本项目废水拟采用“预消毒+格栅+调节池+水解酸化+接触 氧化+MBR 膜池+次氯酸钠消毒+脱氯池”二级处理+深度处理工艺可行。 (2)消毒工艺 医院污水消毒是医院污水处理的重要工艺过程, 其目的是杀灭污水中的致 病菌。目前医院污水消毒常用的工艺有 液氯、次氯酸钠、 二氧化氯、臭氧及紫 外线消毒。下表对常用的消毒法的优缺点进行了归纳和比较。 表 6-2 常用消毒方法介绍 序号 消毒方法 方法简介 液氯是一种强氧化剂和广谱杀菌剂, 既能杀菌又能降解有机物, 且价格低廉, 1 Cl2 但液氯法对水质、 水温、 菌种及接触时间均有影响, 必须定比投加, 投量不足 不能保证消毒效果, 过多又会造成二次污染, 且在安全方面, 液氯存在较大危 险性, 储存、 运输极不方便, 故液氯法在医院污水处理中已较少采用。 2 NaClO 次氯酸钠消毒是利用商品次氯酸钠溶液或现场制备的次氯酸钠溶液作为消毒 181 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 剂, 利用其溶解后产生的次氯酸对水中的病原菌具有良好的杀灭效果, 对污水 进行消毒。次氯酸钠是很小的中性分子, 它能扩散到带负电荷的细菌表面, 并 穿透至细菌内部, 从而氧化和破坏细菌的酶系统。 次氯酸钠法消毒效果可满足 医院污水的排放要求, 处理过程无臭无味, 且国产次氯酸钠发生器性能目前较 为稳定可靠。缺点是电耗、 盐耗较大, 设备体积大, 安装复杂, 劳动强度较 大。 但如果有条件能就近购得现成的次氯酸钠溶液, 则可降低投资和运行成 本。 二氧化氯具有高效氧化剂、 消毒剂以及漂白剂的功能。 作为强化氧化剂, 它所 氧化的产物中无有机氯化物; 作为消毒剂, 它具有广谱性的消毒效果。 二氧化 氯杀菌力极强, 一般为自由氯的 215 倍, 是次氯酸钠的 3~5 倍, 是国际上公 3 ClO2 认的含氯消毒中唯一的高效消毒剂, 且能降低水中的色、 浊度, 去臭杀藻, 而 不产生氯代有机物, 甚至能降解水中微量致癌有机物, 现正逐步取代液氯法、 次氯酸钠法。 但二氧化氯不能储存, 须现用现制, 且要严格控制余氯, 使之不 超过 0.5mg/L。 每公斤二氧化氯混合气体一般可处理医院污水 20~30t。 臭氧(O3)是仅次于氟的强氧化剂, 在水中极不稳定, 很快分解, 反应式: O3→O2+ [O] + 268kJ 分解产物单原子[O]有很强的氧化性, 能分解氧化细菌的酶 系统,可以与细菌、 病毒直接作用, 导致其丧失生长繁殖能力。 臭氧杀灭细菌 速度比氯快 600~3000 倍, 不产生有毒的副产品, 并能有效地清除水的色、 臭 4 O3 味、Fe、 Mn 及有机物污染, 还能氧化杀虫剂。 臭氧法在欧美等发达国家日益 受到青睐。 但臭氧法产生的尾气及管道的臭氧泄漏均会对空气造成二次污染, 虽然臭氧尾气经尾气塔内的霍加拉特吸附剂吸附, 但实践证明其吸附效果并不 理想。 另外, 臭氧在水中易挥发, 无持续消毒能力。 臭氧法的基建、 运行费 用均是次氯酸钠法的数倍, 且国产的臭氧发生器成套设备质量目前不太过关, 维修量大。 消毒使用的紫外线是 C 波紫外线, 其波长范围是 200~275nm, 杀菌作用最强 的波段是 250~270nm。 紫外线消毒技术是利用特殊设计的高功率、 高强度和长 寿命的 C 波段紫外光发生装置产生的强紫外光照射流水, 使水中的各种细菌、 病毒、 寄生虫、 水藻以及其他病原体受到一定剂量的紫外 C 光辐射后,其细胞 5 紫外线 组织中的 DNA 结构受到破坏而失去活性, 从而杀灭水中的细菌、 病毒以及其 它致病体, 达到消毒杀菌和净化的目的。 紫外线杀菌速度快, 效果好,不产生 任何二次污染, 属于国际上新一代的消毒技术。 但要求水中悬浮物浓度较低, 以保证良好的透光性, 出水悬浮物浓度小于 10mg/L 的污水处理系统可采用紫外 消毒方式。 182 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 表 6-3 常用消毒方法比较 消毒方 法 优点 缺点 具有持续消毒左右; 产生具致癌、 致畸作用的 工艺简 Cl2 NaClO 单, 技术成熟; 操 处理水有氯或氯酚味;氯气 作简单, 投量准 腐蚀性强, 运行管理有一 确。 定的危险性。 无毒, 运行、 管理 无危险。 具有强烈的氧化作 用, 不产生有机氯 ClO2 化物(THMs) ; 投 放简单方便; 不受 pH 影响。 有强氧化能力, 接 O3 有机氯化物(THMs) ; 产生具致癌、 致畸作用的 有机氯化物(THMs) ; 使水的 pH 值升高。 消毒效果 适用条件 能有效杀菌, 远离人口聚居区的规 但 模较大(>1000床) 杀灭病毒效果 且管理水平较高的医 较差 与 Cl2 杀菌效 果相同 ClO2 运行、 管理有一定危 险性; 职能就地生产就地 与 Cl2 杀菌效 使用; 制取设备复杂;操 果相同 作管理要求高。 院污水处理系统。 规模<300床的经济欠 发达地区医院污水处 理消毒系统 适用于各种规模医院 污水的消毒处理,但 要求管理水平较高。 传染病医院污水应优 臭氧运行、 管理有一定的 触时间短,不产生有 危险性; 操作复杂; 制取 杀菌和杀灭病 机氯化物; 不受 pH 臭氧的产率低; 电能消耗 毒的效果均很 影响; 能增加水中 大; 基建投资较大; 运行 好 溶解氧 成本高。 先采用臭氧消毒;处 理出水再生回用或排 入水体对水体和环境 造成不良影响时应首 选臭氧消毒 当二级处理出水 无有害的残余物质; 无臭味;操作简单, 紫外线 易实现自动化; 运 行管理和维修费用 低。 电耗大; 紫外灯管和石英 套管需定期更换; 对处理 水的水质要求较高; 无后 续杀菌作用 254nm紫外线透射率 效果好, 但对 60%、悬浮物浓度 悬浮物浓度有 <20mg/L时,或特殊 要求 要求情况(如排入有 特殊要求的水域)可 采用紫外消毒方式 从杀菌和杀灭病毒的效果来看,液氯、次氯酸钠、二氧化氯、臭氧和紫外 线消毒的效果均较好,但液氯运营管理有危险性,二氧化氯操作管理要求高, 臭氧消毒的运行成本高,紫外线消毒的电耗大,并且消毒效果受处理水的水质 制约。 183 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 根据评价调研,目前医院污水消毒多数采用次氯酸钠消毒。综合考虑消毒 效果和运行管理等因素,医院消毒采用次氯酸钠消毒工艺,在消毒池出口处设 置在线监测装置,对余氯进行在线监测。 次氯酸钠用于医院污水处理设施废水的消毒及灭菌,具有无毒,运行、管 理无危险性的优点,其对污水消毒具广谱的杀菌能力,不受浊度及 pH 值的影 响,对细菌胞壁穿透能力强,能在短时间内彻底杀灭细菌,有持续的杀菌作用, 保持一定的余氯量,杀菌效果可达 99.99%以上。根据《医疗机构水污染物排 放标准》(GB18466-2005)表 1 传染病、结核病医疗机构水污染物排放要求, 废水在消毒接触池接触时间≥1.5h。经消毒处理后可去处绝大部分致病菌、病 毒,并有一定量余氯。为降低污水中余氯含量,消毒池后设置脱氯池投加脱氯 剂(硫代硫酸钠),确保出口总余氯限值为 6.5~10mg/L。 项目不在现场制备次氯酸钠,直接外购次氯酸钠,按比例用稀释剂溶解稀 释后产生次氯酸钠消毒液,通过水射器将消毒液与待处理水体充分混合,达到 消毒处理的目的。故本项目综合废水可采用次氯酸钠进行消毒。 6.2.1.3 污水处理工艺介绍及工艺流程 本项目在医院内设置地下封闭式污水处理站,采用“预消毒+格栅+调节池 +水解酸化+接触氧化+MBR 膜池+次氯酸钠消毒+脱氯池”处理工艺,具体工艺 流程见图 6-1。 184 郸城县人民医院西南院区新建项目环境影响报告书 图6-3 第六章环境保护措施及其可行性论证 拟建污水处理站废水处理流程 工艺说明: (1)病区食堂废水经油水分离器处理、病区化验室废水经酸碱中和处理 后经过臭氧预消毒,然后与化粪池+臭氧预消毒处理过的病区其他医疗废水 (门诊废水、 住院病房废水、 医务人员废水、空调冷凝水、蒸汽消毒废水)、 隔油预处理过的非病区普通食堂废水、普通化粪池处理过的非病区其他生活污 185 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 水(后勤办公人员废水、宿舍楼、空调冷凝水)一起排入医院综合污水处理站 进一步处理达标后,汇入郸城县第三污水处理厂。消毒蒸汽纯水制备浓水和非 病区空调冷凝水作为清排水直接排入医院总排口。 (2)综合废水经格栅池去除大颗粒的悬浮物、毛发、食物残渣等,然后 进入调节池。 (3)隔栅出水自流进入调节池,进行均质、均量,尽量减少废水冲击负 荷的影响,以达到理想的处理效果。 (4)调节池出水进入水解酸化池进行处理, 水解阶段是大分子有机物降 解的必经过程, 大分子有机物想要被微生物所利用, 必须先水解为小分子有 机物, 这样才能进入细菌细胞内进一步降解。 酸化阶段是有机物降解的提速 过程, 因为它将水解后的小分子有机物进一步转化为简单的化合物并分泌到细 胞外。 有机物经过水解酸化后更有利于废水的可生化性, 为后续生化处理提 供良好的水质环境。 (5)水解酸化池出水进入生物生物接触氧化池进行生化处理,去除大部 分的有机物污染物。在接触氧化池存在好氧微生物及消化菌, 其中好氧微生物 将有机物分解成 CO2 和 H2O, 在充足供氧条件下, 硝化菌的硝化作用将 NH3N 氧化为 NO3-。 (6)经生物接触氧化池处理后的废水进入 MBR 膜池,通过膜分离技术去 除微生物体和悬浮颗粒物,使出水水质更加稳定和优良。膜池出水进入消毒池, 通过次氯酸钠进行消毒。为降低污水中余氯含量,消毒池后设置脱氯池投加脱 氯剂(硫代硫酸钠),确保出口总余氯限值为 2~8mg/L,满足《医疗机构水污 染物排放标准》(GB18466-2005)表 1 接触池出口总余氯浓度要求。消毒后的 废水经污水管网排入郸城县第三污水处理厂。 (7)沉淀池和污水处理其它过程产生的污泥进入污泥处理系统,经消毒、 浓缩脱水处理后,进行密闭封装,由具有危险废物处理资质的单位进行集中处 置。 186 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 本项目废水经地下污水处理站处理后,出水水质能够达到《医疗机构水污 染物排放标准》(GB18466-2005)表 1 传染病、结核病医疗机构水污染物排放 浓度、最高允许排放负荷标准要求和郸城县第三污水处理厂进水水质要求。因 此,项目处理方法在技术上是可行的。 6.2.1.4 拟建污水处理站规模及效果 根据《医院污水处理工程技术规范》(HJ2029-2013)应在实测或测算的基 础上留有设计裕量,设计裕量宜取实测值或测算值的 10%-20%。考虑到医院日 常有加床现象,本评价污水站设计时取排水量的 1.2 倍系数。经计算,全院地 下污水处理站设计规模为 710m3/d 可以满足本工程的需求。 由前述工程分析可知,本项目废水经“预消毒+预处理+格栅+调节池+水解 酸化+接触氧化+MBR 膜池+次氯酸钠消毒+脱氯池”污水处理站处理后,污染物 排放浓度 COD56.0mg/L、BOD517.0mg/L、SS18.6mg/L、NH3-N13.9mg/L、动 植物油 3.9mg/L、粪大肠菌群数 87.1MPN/L、LAS4.8mg/L、肠道致病菌及肠道 病毒、结核杆菌不得检出,能够满足《医疗机构水污染物排放标准》 (GB18466-2005)表 1 传染病、结核病医疗机构水污染物排放浓度。COD、 BOD5、SS 排放负荷分别为 42.4g(/ 床位·d)、12.9 g(/ 床位·d)、14.1g(/ 床 位 ·d ) , 能 够 满 足 GB18466-2005 中 表 1 最 高 允 许 排 放 负 荷 标 准 要 求 要 求 “COD60g(/ 床位·d)、BOD520g(/ 床位·d)、SS20g(/ 床位·d))”,同时 也可以满足郸城县第三污水处理厂进水水质要求。 为降低污水中余氯含量,消毒池后设置脱氯池投加脱氯剂(硫代硫酸钠), 确保出口总余氯限值为 6.5~10mg/L,满足《医疗机构水污染物排放标准》 (GB18466-2005)表 1 接触池出口总余氯浓度要求。 综上,医院污水处理站采用的处理工艺可行。 6.2.1.5 郸城县第三污水处理厂接纳能力分析 (1)收水范围及周边污水管网调查 187 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 郸城县第三污水处理厂占地面积 57440.35 平方米,建设工程总设计规模为 4 万 m³/d,分两期建设。一期工程已于 2022 年 4 月通过自主验收。一期工程 建设规模为 2 万 m³/d,主要对郸城县新城区(北至洺河、南至皇姑河、西至公 园西路、东至府东路)及汲冢镇的生活污水进行收集处理。项目污水处理二级 采用“水解酸化+AAO 生化处理”工艺,深度处理采用“磁混凝沉淀池+深床 滤池+紫外线消毒”工艺,污泥采用“重力浓缩+板框压滤”工艺脱水干化。郸 城县第三污水处理厂处理后水质执行《城镇污水处理厂污染物排放标准》 (GB18918—2002)中一级标准 A 标准,同时满足《周口市 2019 年水污染防治攻 坚战实施方案》及中共河南省委、河南省人民政府发布的《加强生态环境保护 打好污染防治攻坚战责任书》(2018-2020)中的《地表水环境质量标准》 (GB3838-2002))IV 类标准后,进入洺河。 根据前述分析,根据郸城县第三污水处理厂的收水范围为郸城县新城区 (北至洺河、南至皇姑河、西至公园西路、东至府东路)及汲冢镇的生活污水, 本项目医院东侧紧临公园东路,本项目位于郸城县第三污水处理厂收水范围内。 郸城县第三污水处理厂位于周口市郸城县郸淮公路与公园西路交汇处以西, 本项目医院东侧紧临公园东路,项目医院与郸城县第三污水处理厂的位置关系 及排水路径见附图 17,可见本项目与郸城县第三污水处理厂均位于公园西路西 侧不远(直线距离 3.42 公里),项目位于郸城县第三污水处理厂收水范围内, 项目医院污水处理达标后排入公园西路污水管网,然后沿公园西路向北 3.55 公 路折向西侧污水厂进厂路,汇入郸城县第三污水处理厂处理。 根据现场调查,郸城县第三 污水处理厂一期工程已于 2022 年 4 月自主验 收,污水厂现正常运行,污水厂进厂路和公园西路配套的污水管网均已敷设完 善,正常运行。本项目医疗废水处理达标后可经公园西路已敷设的市政污水管 网排入郸城县第三污水处理厂进一步处理。因此从排水路径上分析,本项目废 水排入郸城县第三污水处理厂进一步处理可行。 (2)从水量上分析 188 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 郸城县第三污水处理厂工程设计污水日处理 2.0 万吨规模,根据调查,目 前污水处理厂收水量为 6080m3/d,剩余处理能力 13920m3/d。 本项目总排水量为 609.24m3/d,约占郸城县第三污水厂剩余处理能力的 4.38%,完全可以接纳本项目产生的废水。本项目废水可进入郸城县第三污水 处理厂进行处理。从水量分析,项目排入郸城县第三污水处理厂进一步处理可 行。 (3)从水质上分析 从水质上来说,本项目排水水质和郸城县第三污水处理厂进水水质对比见 表 6-4。 表 6-4 COD 项目 本项目排水水质和郸城县第三污水处理厂进水水质比较一览表 BOD5 SS 氨氮 (mg/L (mg/L (mg/L (mg/ ) ) ) L) 500 200 300 60 20 56.0 17.0 动植物 粪大肠 油 菌群 (mg/L (MPN/ LAS (mg/ L) ) L) 35 / / / 20 15 5 100 5 18.6 13.9 3.9 87.1 4.8 肠道致 肠道病 结核杆 病菌 毒 菌 (MPN/ (MPN/ (MPN/ L) L) L) / / / 全盐类 (mg/L ) 郸城县第 三污水处 理厂进水 / 水质 GB184662005 《医疗机 构水污染 物排放标 准》表1传 染病、结 不得检 不得检 不得检 出 出 出 / 核病医疗 机构水污 染物排放 标准 本项目总 排口水质 189 不得检 不得检 不得检 出 出 出 111.0 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 由表 6-4 可以看出,而本项目外排水质可以满足郸城县第三污水处理厂进 水水质要求,同时满足《医疗机构水污染物排放标准》表 1 处理排放标准,同 时也完全可以满足郸城县第三污水处理厂的进水要求。 综上分析,本项目外排废水进入郸城县第三污水处理厂是可行的。 6.2.1.6 污水处理设施投资费用估算 根据建设单位提供资料,具体污水处理工程投资费用情况及废水处理成本 核算详见表 6-5 和表 6-6。 表 6-5 污水处理工程投资费用一览表 序号 内容 项目建成费用(万元) 1 构(建)筑物投资 120 2 主要设备投资 60 180 合计 表 6-6 项目 废水处理成本一览表 单位费用(元//t水) 备注 项目建成后合计 电费 1.45 1.0元/度 药剂费 0.5 絮凝剂、消毒剂 人工费 0.12 3人,工资3000元/月 污水处理站吨 2.31 — 49.4万元 不包括设备折旧费 水处理费用 年总运行成本 由表 6-6 可以看出,厂内污水处理站吨水处理费用为 2.31 元/t 水,年运行 成本为 49.4 万元。据建设单位介绍,本项目运行正常后,年均净利润 6155.26 万元,污水处理运行费用占净利润 0.80%,占比较小。 综上,本项目废水处理措施技术经济可行。 6.2.2 废气治理措施评价 根据工程分析,本工程产生的废气主要为含菌废气、检验废气、食堂油烟 和汽车尾气、生活垃圾收集站恶臭及污水处理站产生的恶臭、备用发电机燃烧 废气。 190 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 6.2.2.1 含菌废气 本项目医疗区通风废气及其他科室可能含传染性的细菌和病毒,本项目拟 通过紫外灯照射的方式消毒,以减轻对环境的影响。基于病毒致病机理、条件 等差异,对项目产生含菌气体可能对周围环境的影响很难作准确的定量分析, 本评价根据医院室内空气消毒的要求对本项目产生的含细菌废气对周围环境的 影响进行分析。本项目病区含菌废气采用紫外线杀毒后经专用排风烟道引至楼 顶排放;手术室、负压病房采用全新风直流式空调系统,送风应经过初效、中 效、高效过滤器三级处理,排风经过高效过滤器过滤处理后经过专用排风烟道 引至楼顶排放,可以减轻含菌废气对环境的影响,使各科室内细菌总数符合 《室内空气中细菌总数卫生标准》(GB/T17093-1997)室内空气中细菌总数规定 撞击法≤4000cfu/m3 规定;经消毒后,医院内各类环境空气的细菌总数均低于 室内空气卫生标准,含菌气体经消毒后在室外经扩散和稀释后对最近居民区基 本无影响。 6.2.2.2 检验废气 本项目在检验过程中使用少量有机试剂等 (如酒精、甲醇、二甲苯等) ,这 些物质具有一定的挥发性,日常封闭储存,使用时会产生少量的挥发性有机 废 气等。该部分废气的挥发量很少,检验过程均采用全自动分析设备,只需将药 剂和样品放进设备内,即可自动进行化验得出结果,整个过程均由密闭的设备 进行,检验室内设有安全柜,检验废气经安全柜自带的高效空气过滤器处理后 去除致病细菌、生物气溶胶及其他污染物有害气体后,再引至楼顶排放,排气 中的致病细菌及生物气溶胶可被除去,减轻对环境和周围环境的影响,同时医 院做好检验室内的消毒卫生工作,确保检验废气处理后不会对周围环境造成明 显影响。 高效过滤器过滤原理是采用了活性炭的吸附作用,不仅可以去除粉尘、烟 雾和有机、无机污染物,还可以在空气中去除异味和有害气体。参考《医院消 毒卫生标准》(GB15982-2012),高效空气过滤器是可行的含菌废气消毒措施。 191 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 6.2.2.3 食堂油烟废气 项目设置 2 个食堂,后勤办公综合楼内设置 1 个食堂供后勤办公人员就餐 (就餐人员 300 人,设 2 个灶头),门诊医技综合楼设置 1 个食堂供医护人员 及病患就餐(就餐人员 2500 人,设 12 个灶头)。食堂油烟安装高效静电式油 烟净化器对食堂油烟废气进行处理后经各自楼顶排放。 高效静电式油烟净化器的工作原理:油烟由风机吸入高效静电油烟净化器, 其中部分较大的油雾滴、油污颗粒在均流板上由于机械碰撞、阻滞而被捕集。 当气流进入高压静电场时,在高压电场的作用下,油烟气体电离,油雾荷电大 部分得以降解炭化,少部分微小油粒在吸附电场的电场力及气流作用下向电场 的正负极板运动被收集在极板上,并在自身重力的作用下流到集油盘,经排油 通道排出,余下的微米级油雾被电场降解成二氧化碳和水,最终排出洁净空气, 对油烟去除效率在 95%以上,本次评价按 95%计。对非甲烷总烃的去除效率按 70%计。 本项目后勤办公综合楼食堂油烟废气经高效静电式油烟净化器处理后,项 目建成后油烟总排放量为 0.00329t/a、0.0015kg/h,排放浓度为 0.375mg/m3,非 甲烷总烃总烃排放量为 0.00330t/a、0.0015kg/h,排放浓度为 0.377mg/m3。满足 河南省地方标准《餐饮业油烟污染物排放标准》(DB41/1604-2018)(油烟 1.0mg/m3,非甲烷总烃 10.0mg/m3),由专用排烟通道引至后勤办公综合楼楼 顶排放。 门诊医技综合楼食堂油烟废气经高效静电式油烟净化器处理后,项目建成 后油烟总排放量为 0.0274t/a、0.0125kg/h,排放浓度为 0.521mg/m3,非甲烷总 烃总烃排放量为 0.0275t/a、0.0126kg/h ,排放浓度为 0.524mg/m3。满足河南省 地方标准《餐饮业油烟污染物排放标准》(DB41/1604-2018)(油烟 1.0mg/m3, 非甲烷总烃 10.0mg/m3),由专用排烟通道引至门诊医技综合楼楼顶排放。 因此,本项目食堂油烟废气采取的处置措施可行。 192 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 6.2.2.4 汽车尾气 汽车尾气主要是指汽车进出停车场及在停车场内行驶时,汽车怠速及慢速 (≤5km/h)状态下排放的尾气,主要污染因子为 CO、THC、NOX 等。本评价 建议停车场工作人员在上下班高峰期要及时疏导进出停车场车辆,减少汽车怠 速、慢速行驶的时间,在泊车位和道路两侧加强绿化,可有效减小汽车尾气排 放速率,减小对周围大气环境的影响。 6.2.2.5 生活垃圾收集站恶臭 该项目设专门的垃圾收集站房,院区的生活垃圾由密闭式塑料垃圾桶收集 大生活垃圾收集点,每天由环卫部门集中清运处理,生活垃圾收集站不进行垃 圾处理、无压缩工艺。在生活垃圾的收集、转运过程中,部分易腐败的有机垃 圾由于分解会释放出异味,对环境的影响主要表现为恶臭,其主要成分是 H2S、 NH3。 垃圾恶臭气体是多组分、低浓度化学物质形成的混合物,污染物成分复杂, 成分和含量均较难确定,目前尚无垃圾收集点恶臭气体产生量的计算方法,根 据经验,垃圾桶产生的恶臭很轻微,对环境无明显影响。 评价要求采取的措施:垃圾袋装化,可有效防止生活垃圾收集站)H2S 和 NH3 等恶臭污染物散发,必要时使用除臭剂;尽量减少垃圾暴露时间,及时清 运,日产日清,夏季增加清运次数。 6.2.2.6 地下污水处理站产生的恶臭 本次工程地下污水处理站恶臭气体主要为污水处理站处理废水过程中产生 的恶臭气体,其主要污染物为臭气浓度、H2S、NH3 等,主要来自格栅和污泥处 理区,这些恶臭气体对周围大气环境会产生一定的影响。硫化氢气体具有臭鸡 蛋味,有一定的刺激性。 根据国家环境保护总局文件《关于发布<医院污水处理技术指南>的通知》 (环发【2003】1997 号)文件要求: 193 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 1、为防病毒从医院水处理构筑物表面挥发到大气中而造成病毒的二次传播 污染,将水处理池加盖板密闭起来,盖板上预留进、出气口,把处于自由扩散 状态的气体组织起来。 2、组织气体进入管道定向流动到能阻截、过滤吸附、辐照或杀死病毒、细 菌的设备中,经过有效处理后再排入大气。 3、废气处理可采用臭氧、过氧乙酸、含氯消毒剂、紫外线、高压电场、过 滤吸附和光催化消毒处理对空气传播类病毒进行有效的灭活。 本项目地下污水处理站采用封闭式,污泥脱水间封闭,污水处理站及污泥 脱水间产生的恶臭拟采用“负压抽吸+生物除臭+紫外线消毒后经管道引至附近病 房楼楼顶排放”的方法进行处理。 生物除臭是采用生物法通过专门培养在生物滤池内生物填料上的微生物膜 对废臭气分子进行除臭的生物废气处理技术。当含有有毒、有害、有恶臭的废 气经收集管道导入本系统后通过培养生长在生物填料上的高效微生物菌株形成 的生物膜来净化和降解废气中的污染物。此生物膜一方面以废气中的污染物为 养料,进行生长繁殖;另一方面将废气中的有毒、有害恶臭物质分解,降解成 无毒无害的 CO2,H2O,H2SO4,HNO3 等简单无机物,从而达到除臭的目的。 紫外线灯管产生的紫外线对废气中的病菌进行杀灭,符合《关于发布<医院污水 处理技术指南>的通知》(环发【2003】1997 号)文件中废气处理可采用臭氧、 过氧乙酸、含氯消毒剂、紫外线、高压电场、过滤吸附和光催化消毒处理对空 气传播类病毒进行有效的灭活的要求。 根据工程分析,污水处理站、污泥脱水间排放的臭气浓度、H2S 和 NH3 经 “负压抽吸+生物除臭+紫外线消毒”处理后,经管道引至附近病房楼楼顶排放 (20m 高),恶臭污染物(硫化氢、氨、臭气浓度)排放速率均满足《恶臭污 染物排放标准》(GB14554-93)表 2 标准,因此,本项目地下污水处理站恶臭不 会对周围居民区造成明显的不利影响;根据《排污许可证申请与核发技术规范 194 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 医疗机构》(HJ1105-2020)中表 A.1 可知,生物除臭处理设施属于可行性技术, 综合分析,本项目采取的治理措施可行。 6.2.2.7 备用柴油发电机废气 本项目用电采用双回路供电,柴油发电机为备用电源,使用频次极低, 产生的污染物 CO、HC、NO2 等极少。评价要求,发电机废气经自带的净化 装置处理后,通过专用烟道引至附近病房楼楼顶排放。排放口不朝向病房楼、 医诊楼,废气不会对造成影响。 6.2.3 固体废物处理措施评价 医院是人群及患者活动、治疗、检查和生活的集中场所,在正常运营过程 中产生的固体废物包括生活垃圾、医疗废物等。各固体废物产生量及处理处置 措施见表 6-7。 表 6-7 序号 污染物 全院固体废物产生情况一览表 产生途径 固废性质 全院产生量 处理措施 生活垃圾分类收集后, 医务后勤人员 1 日产日清,每天由环卫 办公及宿舍产 医务后勤人员 生的普通生活 办公及宿舍 一般固废 292t/a 垃圾 部门负责清运至市政垃 圾中转站,最终运至郸 城县生活垃圾焚烧厂发 电厂焚烧 采用专用餐厨垃圾收集 2 餐厨垃圾 食堂 一般固废 511t/a 桶收集,集中收集后交 由有资质的单位进行运 输处 置 3 废反渗透膜 (纯水制备) 纯水制备 一般固废 0.1t/a 更换后随生活垃圾一同 交环卫部门清运处理 经袋装收集后,暂存于 门诊、病房楼 4 医疗废物暂存间内,并 病人产生的生 门诊、病房楼 活垃圾(属于 病人 医疗废物 321.2 医疗废物) 按照医疗废物进行暂存 管理和处置,定期交由 有资质单位进行清运处 置 5 6 医疗废物 污水处理站产 门诊科室及 病房楼 污水处理站 医疗废物暂存间暂存 危险废物 148.92 后,委托有资质单位进 行集中处理 危险废物 195 132.5821 消毒脱水后,作为危险 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 生的污泥 污水处理站产 7 生的栅渣 废紫外线含汞 8 灯管 废物定期交有资质单位 污水处理站 危险废物 3.8492 紫外线消毒 危险废物 0.16 处置 危废间暂存后交由有资 质危废单位安全处置 6.2.3.1 一般固废 项目一般固废包括医务后勤人员办公及宿舍产生的普通生活垃圾、餐厨垃 圾。 医务后勤人员办公及宿舍产生的普通生活垃圾:本项目劳动定员 1200 人, 宿舍 400 人,按人均生活垃圾产生量 0.5kg/d 计算,则生活垃圾产生量为 0.8t/d ( 292t/a)。生活垃圾分类收集后,日产日清,每天由环卫部门负责清运至市政垃 圾中转站,最终运至郸城县生活垃圾焚烧厂发电厂焚烧。 餐厨垃圾:项目食堂用餐人次为 2800 人/天,餐厨垃圾产生量按 0.5kg/人 次 ·d 计算,则餐厨垃圾产生量为 1.4t/d (511t/a ) 。餐厨垃圾采用专用餐厨垃 圾收集桶收集,集中收集后交由有资质的单位进行运输处 置。 一般固废暂存间参照《一般工业固体废物贮存和填埋污染控制标准》 (GB18599-2020)的要求: ①贮存、处置场应采取防水、防晒、防渗漏的措施。 ②一般工业固体废物贮存、处置场,禁止危险废物和生活垃圾混入。 ③为保障设施、设备正常运营,必要时应采取措施防止地基下沉。 ④为加强监督管理,贮存、处置场应按《环境保护图形标志》 (GB15562.2)设置环境保护图形标志。 垃圾站内部采用有上盖式垃圾箱密闭存放方式,医院产生的普通生活垃圾 每天收集到生活垃圾站,最后由环卫部门清运至垃圾场进行统一处理,垃圾日 产日清;生活垃圾站定期清扫和消毒;生活垃圾站平时由专人负责管理,定时 收集和转运垃圾,可有效降低垃圾恶臭对周围环境的影响。生活垃圾站与最近 的病房楼的水平距离大于 20m,位于医院常年主导风向的下风向,且生活垃圾 196 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 站周围设置为绿化带,故生活垃圾站对项目内部环境影响不大,医院设有专门 的医院污物出入口,方便生活垃圾清运,故项目生活垃圾站位置设置基本合理。 食堂拟设置餐厨垃圾专用餐厨垃圾桶,暂存于餐厨垃圾暂存处,并保持收 集容器密封完好,集中收集后,每日交由有经营许可的餐厨垃圾收运单位进行 处理。 6.2.3.2 污水处理站产生的污泥、栅渣 本项目污泥总产生量 132.5821 t/a,栅渣总产生量 3.8492 t/a。根据《医疗机 构水污染物排放标准》(GB18466-2005)4.3.1 明确规定污水处理站和栅渣属于 危险废物,查阅《国家危险废物名录(2021 年版)》为危废代码为(HW01 医 疗废物 841-001-01)。 评价建议污水处理站污泥和栅渣在污泥消毒池内采用消毒剂(石灰)消毒, 消毒后通过压滤机进行压滤脱水,危废暂存间暂存后作为危险废物交有资质单 位进行集中处理。 6.2.3.3 废紫外线含汞灯管 废紫外线含汞灯管产生量为 80 支/年约重 0.16t/a,根据《国家危险废物名 录(2021 年版)》,废紫外线灯管为 HW29 含汞废物 900-023-29 类废物。更换 后暂存于危废暂存间 25m2 内,定期交由有资质单位处置。 6.2.3.4 医疗废物 医疗废物主要是医疗过程中产生的各种感染性废物、损伤性废物、病理性 废物、药物性废物和化学性废物。 根据《医疗废物管理条例》第三条规定,医疗卫生机构收治的传染病病人 或者疑似传染病病人产生的生活垃圾,按照医疗废物进行管理和处置。故,感 染病楼一般生活垃圾、餐厨垃圾均属于医疗废物类别为感染性医疗废物,收集 暂存于医疗废物暂存间内,并按照医疗废物进行暂存管理和处置。 根据前述分析,项目医疗废物产生量为 470.12t/a(含门诊楼、病房楼产生 的生活垃圾 321.2t/a),属《国家危险废物名录》(2021 年版)中 HW01 医疗 197 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 废物,项目产生的医疗废物暂存于院内医疗废物暂存间,然后每天交由有危废 处理资质的公司运走处理。 为确保医疗固废的安全处置,国家对医院从固废源头控制、暂存、移交等 方面均有相关的管理措施和要求,结合本医院实际情况具体如下: 1、医疗废物管理的一般规定 本项目应建立、健全医疗废物管理责任制,切实履行职责,同时应制定相 应的事故应急预案,防止因医疗废物导致传染病传播和环境污染事故。对本单 位从事医疗废物收集、运送、贮存、处置等的工作人员进行培训,并配备相应 的职业卫生防护措施。对本项目产生的医疗废物实行登记制。登记内容编包括 医疗废物的来源、种类、重量、数量、交接时间、处置方法、最终去向及经办 人等项目,登记资料至少要保存三年。 2、医疗废物的具体管理措施和要求 (1)分类收集 分类收集是减少危害和安全处理的前堤。收集废物所使用的容器主要是塑 料袋、锐器容器和废物箱等。本项目医疗固废主要包括各种感染性废物、损伤 性废物、病理性废物、药物性废物和化学性废物。 感染性废物:主要分布在门诊、化验、医技室、病房等。根据要求,各诊 室应分别配备专用的废物塑料袋和专用密闭的容器,将各种易收集的如化验标 本、各种敷料等感染性废物收集于专用的塑料袋中,废物塑料袋应有清晰的颜 色标志和注明用途,并放在相应的污物桶中。需高压灭菌(或其他消毒处理) 的废物袋应采用合适的材料制造,并作颜色标记,可加有标志以显示是否经过 所规定的处理程序(如高压消毒指示袋等),袋子上还应有清晰的文字标志, 如“需消毒废物”或“无危害标志”。高压灭菌(或其他消毒处理)后的废物袋小 容器应放入另一种颜色标记的袋子或容器中,以便进行下一步的处置。 损伤性废物:指用过废弃的或一次性的注射器、针头、玻璃、锯片、解剖 刀、手术刀片及其他可能引起切伤刺伤的器物。这些废物不应与其它废物混放, 198 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 用后应稳妥安全地置入密闭的锐器容器中。锐器容器应标以适当的颜色,并用 文字清晰标明专用,并以国际标志符号标志,如“只能用于锐器”、“生物危险 品”。 病理性废物:主要分布在手术室、诊室等,主要为如手术室的人体组织等 废物。医院应在此区设置废物收集设施,该类废物应使用双层废物袋,应用密 封与处理的废物桶(如聚乙烯或聚丙烯塑料桶,容量 30~60L),装满之后应 立即封闭。 药物性废物和化学性废物:主要为过期的各种药品和各种废气的化学消毒 剂和含汞血压计、温度计等,可在各诊室和化验室设置专门的密闭容器。待一 定量时和医疗废物一起进行处置。 所有废物都应丢弃或放入标明适当颜色或标识的垃圾袋或污物桶中,在装 满 3/4 时有人负责封袋,废物一旦放入废物箱后就不宜再取出。医院中有传染 性和有害的污物不能混在一起,若混在一起则应按有害废物处理。 污物袋要定期收集。废物袋应每日运出病房或科室,也可根据需要决定搬 运时间,无标志的废物袋不应搬出,而且应保证安全并防止泄漏。封好的锐器 容器或圆形废物桶搬出病房或科室之前应有明确标志。废物袋应及时更换,任 何情况下都不能用普通袋代替有害废物袋。病房中应同时有 2 种类型的废物袋。 废物袋的大小应根据需要确定,尽量满足各种需要,应保证外袋颜色相符,袋 内可衬以不同颜色和强度的内袋,工作人员应确保废物离开病房或科室时装入 颜色相符的袋子中。医院内废物应在病区、科室与废物中心存放地之间设计规 定转运路径,以缩短医院内废物通过病区与其它清洁区的路线。使用专用手推 车将废物袋(箱)运至废物中心存放地时,手推车应是专门设计的,外形美观, 装卸方便,有任何泄漏时均应彻底清洁与消毒。 (2)暂存 废物袋(箱)在就地处理或异地处理之前,需在医院中心废物存放地集中 暂存,该暂存设施不得漏天存放医疗废物,易腐败的生物废物需贮存于中心存 199 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 放地或病室内的冰箱、冰柜内。医疗废物在医院内的暂存时间不得超过 2 天, 同时医院暂存设施应远离医疗区和食品加工区和人员活动区,应和普通垃圾分 开存放。 (3)移交 本项目产生的各种医疗废物拟委托有资质单位集中收集处理,按照《医疗 废物管理条例》相关要求,医院在医疗废物的转移方面应依照《中华人民共和 国固体废物污染环境防治法》的规定,严格执行危险废物转移联单管理制度。 即医院在转移危险废物在运营过程中具体应做到: ①医院在转移医疗废物前,须按照国家有关规定报批危险废物转移计划; 经批准后,产生单位应当向移出地环境保护行政主管部门申请领取联单。 ②医院每转移一车(次)同类危险废物,应当填写一份联单。 ③医院应当如实填写联单中产生单位栏目,并加盖公章,经交付危险废物 运输单位核实验收签字后,将联单第一联副联自留存档,将联单第二联交移出 地环境保护行政主管部门,联单第一联正联及其余各联交付运输单位随危险废 物转移运行。 ④联单保存期限为五年,贮存危险废物的,其联单保存期限与危险废物的 贮存期限相同。 (4)医疗废物暂时贮存库房的要求 a、必须与生活垃圾存放地分开,有防雨淋的装置,地基高度应确保设施内 不受雨洪冲击或浸泡; b、必须与医疗区和人员活动密集区隔开,方便医疗废物的装卸、装卸人员 及运送车辆的出入; c、应有严密的封闭措施,设专人管理,避免非工作人员进出,以及防鼠、 防蚊蝇、防蟑螂、防盗以及预防儿童接触等安全措施; 200 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 d、地面和 1.0 米高的墙裙须进行防渗处理,地面有良好的排水性能,易于 清洁和消毒,产生的废水应采用管道直接排入医疗卫生机构内的医疗废水消毒、 处理系统,禁止将产生的废水直接排入外环境; e、库房内应张贴“禁止吸烟、饮食”的警示标识; f、应按《环境保护图形标志—固体废物贮存(处置)场》(GB 15562.21995)修改单和卫生、环保部门制定的专用医疗废物警示标识要求,在库房外 的明显处同时设置危险废物和医疗废物的警示标识。 本项目危险废物产生及处置情况见表 6-8。 表 6-8 名称 类别 危险 损伤性废 (含医疗 废物和传 染病楼生 药物性废 活垃圾) 物 危险 污染防治 (t/a) 工序 态 成分 特性 措施 In In (841003-01) 固 HW01 (841- 470.12 日常诊疗 002-01) 态 固 医疗废物 医疗 废物 In 态 HW01 间暂存交 由有资质 单位处置 T/C/I/R (841005-01) HW01 化学性废 T (841- 物 站污泥 主要 HW01 废物 水处理 形 001-01) 病理性废 栅渣、污 产生 (841- 物 物 产生量 HW01 感染性废 物 代码 本项目危险废物产生及处置情况一览表 004-01) 危险 废物 废紫外线 危险 含汞灯管 废物 HW01 (841- 医疗污水 136.4313 处理 001-01) 站 023-29) 固态或泥 态 污泥 In 存交由有 资质单位 处置 危废间暂 HW29 (900- 危废间暂 0.16 紫外线消 毒 固态 汞 T 存交由有 资质单位 处置 201 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 6.2.3.5 危险废物管理要求 根据《建设项目危险废物环境影响评价指南》,危险固废的环境影响应从 危废的产生、收集、运输等全过程考虑,分析项目产生的危险废物可能造成的 环境影响。同时根据《危险废物贮存污染控制标准》(GB18597-2023),该贮 存间应符合如下要求: 1)危险废物的收集 本项目危险废物的收集须严格按照《危险废物收集贮存运输技术规范》 (HJ2025-2012)的要求:①根据危险废物产生的工艺特征、排放周期、特性、 管理计划等因素制定详细的收集计划。收集计划包括收集任务概述、收集目标 及原则、危险废物特性评估、危险废物收集量估算、收集作业范围和方法、收 集设备与包装容器、安全生产与个人防护、工程防护与事故应急、进度安排与 组织管理等。②制定危险废物收集操作规程,内容包括适用范围、操作程序和 方法、专用设备和工具、转移和交接、安全保障和应急防护等。③危险废物收 集和转运作业人员根据工作需要配备必要的个人防护装备,如手套、防护镜、 防护服、防毒面具或口罩等。④危险废物收集时应根据危险废物的种类、数量、 危险特性、物理形态、运输要求等因素选择合适的包装形式。 2)危险废物规范化贮存措施 (1)本项目设置一座 50m2 的医疗废物储存间、25m2 危险废物暂存间, 危废暂存间应按照《危险废物贮存污染控制标准》(GB18597—2023)的相 关规定建设,建设要求如下: ①贮存设施应根据危险废物的形态、物理化学性质、包装形式和污染物迁 移途径,采取必要的防风、防晒、防雨、防漏、防渗、防腐以及其他环境污染 防治措施,不应露天堆放危险废物; ②贮存设施应根据危险废物的类别、数量、形态、物理化学性质和污染防 治等要求设置必要的贮存分区,避免不相容的危险废物接触、混合; ③贮存设施或贮存分区内地面、墙面裙脚、堵截泄漏的围堰、接触危险废 物的隔板和墙体等应采用坚固的材料建造,表面无裂缝; 202 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 ④贮存设施地面与裙脚应采取表面防渗措施;表面防渗材料应与所接触的 物料或污染物相容,可采用抗渗混凝土、高密度聚乙烯膜、钠基膨润土防水毯 或其他防渗性能等效的材料。贮存的危险废物直接接触地面的,还应进行基础 防渗,防渗层为至少 1m 厚黏土层(渗透系数不大于 10-7cm/s),或至少 2mm 厚高密度聚乙烯膜等人工防渗材料(渗透系数不大于 10-10cm/s),或其他防 渗性能等效的材料。同一贮存设施宜采用相同的防渗、防腐工艺(包括防渗、 防腐结构或材料); ⑤贮存设施应采取技术和管理措施防止无关人员进入; ⑥在常温常压下不易水解、不易挥发的固态危险废物可分类堆放贮存,其 他固态危险废物应装入容器或包装物内贮存;液态危险废物应装入容器内贮存, 或直接采用贮存池、贮存罐区贮存。半固态危险废物应装入容器或包装袋内贮 存,或直接采用贮存池贮存。具有热塑性的危险废物应装入容器或包装袋内进 行贮存。易产生粉尘、VOCs、酸雾、有毒有害大气污染物和刺激性气味气体 的危险废物应装入闭口容器或包装物内贮存; ⑦ 各危险废物按照《危险废物识别标志设置技术规范》(HJ 1276—2022) 设置标识。危险废物存入贮存设施前应对危险废物类别和特性与危险废物标签 等危险废物识别标志的一致性进行核验,不一致的或类别、特性不明的不应存 入。作业设备及车辆等结束作业离开贮存设施时,应对其残留的危险废物进行 清理。贮存设施运行期间,应按国家有关标准和规定建立危险废物管理台账并 保存。贮存设施所有者或运营者应建立贮存设施环境管理制度、管理人员岗位 职责制度、设施运行操作制度、人员岗位培训制度等。企业应结合贮存设施特 点建立土壤和地下水污染隐患排查制度,并定期开展隐患排查;发现隐患应及 时采取措施消除隐患,并建立档案。 (2)企业须健全危险废物相关管理制度,并严格落实。①企业须配备专 业技术人员和管理人员专门负责企业危险废物统计、收集、暂存、转运和管理 工作,并对有关危废产生部门员工进行定期教育和培训,强化危险废物管理; 203 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 ②企业须建立危险废物收集操作规程、危险废物转运操作规程、危险废物暂存 管理规程等相关制度,并认真落实;③企业须对危险废物储运场所张贴警示标 示,危险废物包装物张贴警示标签;④规范危险废物统计、建立危险废物收集 及储运有关档案,认真填写《危险废物项目区内转运记录表》,作好危险废物 情况的记录,记录上须注明危险废物的名称、来源、数量、特性和包装容器的 类别、入库日期、存放库位、废物出库日期及接收单位名称等,并即时存档以 备查阅。 (3)危险废物在危废库房内暂存期间应严格按照《危险废物贮存污染控 制标准》(GB18597-2023)和《危险废物收集贮存运输技术规范》(HJ20252012)的相关要求进行存储和管理。①必须将危险废物装入容器内进行密封装 运,禁止将不相容(相互反应)的危险废物在同一容器内混装;②盛装危险废 物的容器应当符合标准,材质要满足相应的强度要求且必须完好无损,容器材 质和衬里要与危险废物相容(不相互反应);③危险废物贮存前应进行检验, 确保同预定接收的危险废物一致,并登记注册,不得接收未粘贴符合规定的标 签或标签没按规定填写的危险废物;④必须定期对所贮存的危险废物包装容器 及贮存设施进行检查,发现破损,应及时采取措施清理更换。 3)、危险废物的转运要求 项目危险废物转运过程中采取篷布遮盖、防滴漏等措施,减少危险废物运 输过程给环境带来污染。危险废物的转运应按照《危险废物收集贮存运输技术 规范》(HJ2025-2012)的要求进行:①危险废物的运输由持有危险废物经营许 可证的单位组织实施,并按照相关危险货物运输管理规定执行;②项目危险废 物运输采用公路运输方式,应按照《道路危险货物运输管理规定》(交通运输 部令 2013 年第 2 号)执行。运输单位承运危险废物时,应在危险废物包装上按 照 GB18597 附录 A 设置标志,运输车辆应按 GB13392 设立车辆标志。危废运 输车辆应配备符合有关国家标准以及与所载运的危险货物相适应的应急处理器 材和安全防护设备。③危险废物运输时的装卸应遵照如下技术要求:装卸区的 204 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 工作人员应熟悉危险废物的危险特性,并配备适当的个人防护装备,如橡胶手 套、防护服和口罩。装卸区域应配备必要的消防设备和设施,并设置明显的指 示标志。装卸区域应设置隔离设施。④危险废物转移过程严格落实《危险废物 转移管理办法》的相关规定,规范危险废物转移;做好每次外运处置废物的运 输登记,认真填写危险废物转移联单(每种废物填写一份联单),并加盖公司 公章,经运输单位核实验收签字后,将联单第一联副联自留存档,将联单第二 联交移出地环境保护行政主管部门,第三联及其余各联交付运输单位,随危险 废物转移运行,第四联交接受单位,第五联交接受地环保局。⑤废物处置单位 的运输人员必须掌握危险废物运输的安全知识,了解所运载的危险废物的性质、 危害特性、包装容器的使用特性和发生意外时的应急措施。运输车辆必须具有 车辆危险货物运输许可证。综上所述,本项目固体废物的收集、贮运和转运环 节应 严格按照《一般工业固 体废物贮存和 填埋污 染控制 标准》 (GBl85992020)、《危险废物贮存污染控制标准》(GB18597-2023)标准以及《危险废 物收集贮存运输技术规范》(HJ2025-2012)等相关规范进行。在加强管理并落 实好各项污染防治措施和固体废物安全处置措施的前提下,本项目产生的固体 废物不会产生二次污染,对周围环境的影响较。 本项目危险废物产生情况见表 6-9。 表 6-9 危险废物贮存场所(设施)基本情况一览表 序 号 1 贮存场所 危险废物 危险废物 (设 名 类 施)名称 称 别 医疗废物 HW01 医疗废物 暂存间 占地面 积 50m2 贮存方式 专用容器 分类收集 贮存能 贮存周 力 期 1t 2天 3t 10天 栅渣、污 2 危险废物 暂存间 水处 HW01 25m2 理站污泥 废紫外线 含汞灯管 HW29 6.2.4 环境噪声污染防治措施分析 205 专用容器 分类收集 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 针对项目的实际特点,建设单位针对不同噪声源采取了一系列的控制措施。 (1)尽可能选择低噪声设备:如空调、通风设备等尽可能选用高效、低转 速、低噪声设备。 (2)针对不同的高噪声设备,采取加强减振基础、装消声器等措施。如中 央空调风冷热泵机组则采用加装消声设备和基础减振等措施; (3)加强各设备的保养、检修、润滑,保证设备良好运转,减轻运行噪声 强度。 (4)中央空调风冷热泵机组设于楼顶、设置隔声罩,设置减振措施等、风机 进出风口安装消声器、减振等降噪措施,污水站风机、水泵房水泵均设置在地 下,液氧站空压机设置在室内。 通过采取以上噪声污染防治措施,完全可以将厂界噪声控制在《工业企业 厂界环境噪声排放标准》(GB12348-2008)中相应标准要求的范围内。 6.2.5 地下水、土壤污染防范措施 根据《环境影响评价技术导则土壤环境》(HJ964-2018)附录 A 表 A.1, 本项目属于“其他行业”,土壤环境影响评价项目类别为“Ⅳ类”,不需要进行土 壤环境影响评价。 根据《环境影响评价技术导则地下水环境》(HJ610-2016),本项目医院 为 IV 类项目,可不进行地下水评价。 本项目地下水、土壤污染防范措施如下: (1) 源头控制 ①严格按照国家相关规范要求,对新建的污水处理站构筑物 、柴油储油间 等采取相应措施,以防止和降低污染物的跑、冒、滴、 漏,将污染物泄漏的环 境风险事故降到最低程度。 ②对污水管道内外均采用防腐处理,定期对管道进行检漏。 (2) 分区防治 206 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 根据《环境影响评价技术导则 地下水环境》 (HJ610-2016) ,结合地下水环 境影响评 价结果,为防止废水下渗污染地下水,给出不同分区的具体防渗技术 要求。项目分三个防 渗区域,分别为重点防渗区、一般防渗区、简单防渗区。 本项目院区分区防渗情况见表 6-10。 表 6-10 项目分区防渗情况一览表 序号 防渗区域 防渗分区等级 化粪池、地下污水管道、医疗废物暂存间、危废暂存间、污泥脱水 1 间、加氯间、臭氧预消毒池、门诊楼、病房楼、柴油发电机房(包括 重点 储油间) 2 后勤行政办公楼、宿舍楼、其他用房 一般 3 院区道路、公共设施区 简单 针对不同的防渗分区,应有针对性的采取不同的防腐、防渗工程措施,评 价建议采取以下防渗防漏措施: (1)重点防渗区 ①化粪池、污水处理站:由有资质的设计施工企业进行规范建设。各水池 应为钢筋混凝土结构并做相应的耐酸、碱表面处理。水池地面以下应铺设 2mm 厚高度聚乙烯膜(渗透系数≤10-10cm/s)。 ②医疗废物暂存间:地面铺设 2mm 厚高密度聚乙烯或至少 2mm 厚的其他 人工材料(渗透系数≤10-10cm/s)。 ③柴油发电机房(包括储油间)、危废暂存间、污泥脱水间、加氯间、臭 氧预消毒池、门诊楼、病房楼、地下污水管道进行重点防渗:防渗宜采用抗渗 钢筋混凝土管沟或 HDPE 膜防渗层。混凝土管沟应符合下列要求: a、抗渗钢筋混凝土管沟的强度等级不宜小于 C30; b、混凝土中应掺加水泥基渗透结晶型防水剂,掺加量宜为 0.8%~1.5%; c、抗渗钢筋混凝土管沟的渗透系数不应大于 1.0×10-10cm/s; d、混凝土垫层的强度等级不宜小于 C15; e、地下抗渗钢筋混凝土管沟顶板强度等级不宜小于 C30,渗透系数不应大 于 1.0×10-10cm/s。 207 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 柴油发电机房储油间除采取重点防渗措施外,还应设置设置防火安全设 施,并严格《危险化学品安全管理条例》(2002 年,国务院第 344 号)的规定 进行运输、储存和使用,储存间内按有关规范要求配置干粉泡沫化学灭火器。 在柴油储存间设置应急桶,并设置围堰。 (2)一般防渗区 后勤行政办公楼、宿舍楼、其他用房:全部地面进行以下处理,以达到和 超过一般土地防渗的要求,满足《环境影响评价技术导地下水环境》(HJ6102016)表 7 地下水污染防渗区参照表中一般防渗区的防渗要求:等效粘土防渗 层 Mb≥1.5m,k≤1.0×10-7cm/s。 (3)简单防渗区 院区道路、公共设施区,简单污染防治区进行地面硬化或绿化,不要求防 渗系数。 按照不同分区要求采取不同等级的防渗措施,并确保其可靠性和有效性。 其中一般防 渗区的防渗设计参照《一般工业固体废物贮存和填埋污染控制标准》 (GB18599-2020) 要 求,重点防渗区的防渗设计满足《危险废物贮存污染控制标 准》 (GB18597-2001) 及修改 单要求。 根据本项目情况,提出以下防渗措施: ①设备、地下管道、建构筑物防渗的设计使用年限不应低于其主体的设计 使用年限。 ②当污染物有腐蚀性时,防渗材料应具有耐腐蚀性能或采取防腐措施。 ③地面防渗:地面硬化,地面防渗可采用高密度聚乙烯膜、钠基膨润土防 水毯或其他 防渗性能等效的材料,防渗性能不应低于 1.5m 厚渗透系数为 1.0× 10-7cm/s 的黏土层的防渗 性能。 ④导排沟:混凝土水池、污水沟的耐久性应符合现行国家标准《混凝土结 构设计规范》 GB50010 的有关规定,混凝土强度等级不宜低于 C30 。排水沟设 为混凝土防渗,其中铺设 管道设计壁厚的腐蚀余量不应小于 2mm 或采用管道 208 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 内防腐;管道的外防腐等级应采用特 加强级;宜采用高密度聚乙烯膜防渗层, 也可采用抗渗钢筋混凝土管沟或套管;地下管道 的高密度聚乙烯膜防渗层的膜 厚度不宜小于 1.5mm 。膜两侧应设置保护层,保护层宜采用 长丝无纺土工布。 (3) 跟踪监测 根据《环境影响评价技术导则 地下水环境》 (HJ/T610-2016) ,本项目为 IV 类项目可不进行地下水评价,本项目严格做好分区防渗措施后对地下水影响较 小,本次评价不再设置跟踪监测井。 (4) 地下水、土壤污染治理措施 工程场地含水层岩性主要为砂卵砾石,其富水性及导水性能均良好,但水 力梯度较平缓;当发生污染事故时,污染物的运移速度较慢,污染范围较小, 因此建议采取如下污染 治理措施。 ①一旦发生地下水污染事故,应立即启动应急预案。 ②查明并切断污染源。 ③一旦发生污染,可对项目下游村庄地下水井进行化验检测分析,一旦发 现监控井地下水受到污染,立即启动抽水设施。 ④探明地下水污染深度、范围和污染程度。 ⑤依据探明的地下水污染情况和污染场地的含水层埋藏分布特征,结合拟 采用的地下 水污染治理技术方法,制定地下水污染治理实施方案。 ⑥依据实施方案进行施工,抽取被污染的地下水体,并依据各井孔出水情 况进行调整。 ⑦将抽取的地下水进行集中收集处理,并送实验室进行化验分析。 ⑧当地下水中的特征污染物浓度满足地下水功能区划的标准后,逐步停止 井点抽水, 并进行土壤修复治理工作。 综上所述,本项目各建构筑物均采取了相应的防渗措施,可有效防止风险 物质及废水 对地下水、土壤的污染 ,对地下水、土壤环境影 响较小。本项目 采取的地下水、土壤污染防治措施合理可行。 209 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 6.3环保措施汇总 建设单位对项目运行产生的“三废”、噪声等采取的污染防治措施针对性较 强,尤其是对主要的污染因素废气、废水、固废采取了有效的防治措施,具有 较强的针对性和可操作性,技术上可行,经济上合理。 本项目污染防治措施汇总见表 6-11。 表 6-11 本项目污染防治措施及效果汇总表 阶段 污染因素 治理措施 处理效果 《污水综合排放标准》 生活污水 废水 处理后排入周边市政污水管网 准及郸城县第三污水处理厂进 水水质要求 施工废水 施工扬尘 机械设备运行 废气及运输车 废气 临时隔油池10m3、化粪池10m3 (GB8978-1996)表4中三级标 辆废气 临时沉淀池20m3处理后回用到 车辆冲洗、施工场地洒水降尘 零排放 落实“八个百分百” 加强设备及车辆维护,施工场 地较开阔,扩散条件良好 减少对周边环境的影响 选用符合国家规定质量要求的 装修废气 环保型油漆、涂料、胶粘剂及 装饰材料 施工 设置围挡,选用低噪声设备及 期 施工工艺,合理布局,合理安 噪声 施工噪声 排施工时间,严禁夜间施工, 满足GB12523-2011《建筑施工 进入敏感区域限速禁鸣,定期 场界环境噪声排放标准》 对设备及车辆维护、养护,加 强施工队伍管理禁止高声喧哗 生活垃圾 固废 垃圾桶进行收集,由环卫部门 统一清运 分类收集,可利用部分回收利 建筑垃圾 用,不能利用部分运至指定建 妥善安置,零排放 筑垃圾填埋场 弃方 运至当地政府指定地点 加强临时堆放场的管理,制定 生态 水土流失 土方表面压实、定期喷水、覆 盖、设置截排水沟等措施;不 210 减少水土流失 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 需要的泥土,建筑材料弃渣应 及时运走,不宜长时间堆积 病区食堂废水经油水分离器处 理、病区化验室废水经酸碱中 和处理后经过臭氧预消毒,然 后与化粪池+臭氧预消毒处理 过的病区其他医疗废水(门诊 废水、 住院病房废水、 医务 人员废水、空调冷凝水、蒸汽 消毒废水)、隔油预处理过的 废水 综合废水 非病区普通食堂废水、普通化 粪池处理过的非病区其他生活 污水(后勤办公人员废水、宿 舍楼、空调冷凝水)一起排入 医院综合污水处理站进一步处 经处理后达到《医疗机构水污 染物排放标准》(GB184662005)表1传染病、结核病医 疗机构水污染物排放浓度、最 高允许排放负荷标准要求和郸 城县第三污水处理厂进水水质 要求 理达标后,汇入郸城县第三污 水处理厂,尾水排入洺河。消 毒蒸汽纯水制备浓水和非病区 空调冷凝水作为清排水直接排 运营 入医院总排口。 期 病区含菌废气采用紫外线杀毒 后经专用排风烟道引至楼顶排 放;手术室、负压病房采用全 含菌废气 新风直流式空调系统,送风应 经过初效、中效、高效过滤器 三级处理,排风经过高效过滤 含菌气体经消毒后在室外经扩 散和稀释后对最近居民区基本 无影响 器过滤处理后经过专用排风烟 道引至楼顶排放 经安全柜配套高效空气过滤器 废气 处理后去除致病细菌、生物气 溶胶及其他污染物有害气体 检验废气 后,再引至楼顶排放,同时医 / 院做好检验室内的消毒卫生工 作,确保检验废气处理后不会 对周围环境造成明显影响 后勤办公综合 楼食堂油烟 经1套高效静电式油烟净化器 废气排放情况可以满足河南省 处理后经烟道引至后勤办公综 地方标准《餐饮业油烟污染物 合楼楼顶排放 211 排放标准》(DB41/1604- 郸城县人民医院西南院区新建项目环境影响报告书 门诊医技综合 楼食堂油烟 第六章环境保护措施及其可行性论证 经1套高效静电式油烟净化器 处理后经烟道引至门诊医技综 合楼楼顶排放 机动车泊车位 在地下车库设置抽排风系统, 汽车尾气 污水处理站恶 臭气体 2018)大型 及时疏导进出泊车位车辆 负压抽吸+生物除臭+紫外线消 毒后经管道引至附近病房楼楼 顶排放 周围环境影响较小 满足《恶臭污染物排放标准》 (GB14554-93)表2标准的要求 仅收集,不处理不压缩。垃圾 生活垃圾收集 袋装化,减少垃圾暴露时间, 满足《恶臭污染物排放标准》 站恶臭 及时清运,日产日清,使用除 (GB14554-93)表2标准的要求 臭剂 备用柴油发电 由自带的净化装置处理后经管 机 废气 医务后勤人员 办公及宿舍产 生的普通生活 垃圾 道引至附近构筑物楼顶排放 / 生活垃圾分类收集后,日产日 清,每天由环卫部门负责清运 至市政垃圾中转站,最终运至 郸城县生活垃圾焚烧厂发电厂 焚烧 采用专用餐厨垃圾收集桶收 餐厨垃圾 集,集中收集后交由有资质的 单位进行运输处 置 固 废 废反渗透膜 更换后随生活垃圾一同交环卫 (纯水制备) 部门清运处理 门诊、病房楼 经袋装收集后,暂存于医疗废 得到合理处置 病人产生的生 物暂存间内,并按照医疗废物 活垃圾(属于 进行暂存管理和处置,定期交 医疗废物) 医疗废物 由有资质单位进行清运处置 医疗废物暂存间暂存后,委托 有资质单位进行集中处理 污水站及栅 消毒压滤后暂存于危废暂存间 渣、污泥 交有资质单位处理 废紫外线含汞 危废间暂存交由有资质单位处 灯管 置 满足《工业企业厂界环境噪声 噪 声 设备噪声 采取基础减振、消音降噪、隔 声等措施 排放标准》(GB123482008)、《声环境质量标准》 (GB3096-2008)相关标准要 求 地下 分区防渗,可能造成地下水、土壤污染的单元 减少对区域地下水、土壤环境 212 郸城县人民医院西南院区新建项目环境影响报告书 水、 第六章环境保护措施及其可行性论证 加大防渗力度、完善防渗措施 影响。 土壤 6.4环保设施验收清单 本项目总投资 63480 万元,项目建成后环保投资 532 万元,环保投资占总 投资比例 0.84%,环保设施验收清单见表 6-12。 表 6-12 项目环保设施验收一览表 投资 阶 污染因素 段 治理措施 验收内容 处理效果 (万 元) 《污水综合排 放标准》 临时隔油池10m3、化粪 生活污水 池10m3处理后排入周边 市政污水管网 废水 (GB8978临时隔油池10m3、化粪 1996)表4中三 池10m3 级标准及郸城 县第三污水处 5 理厂进水水质 要求 临时沉淀池20m3处理后 施工废水 回用到车辆冲洗、施工 临时沉淀池20m3 零排放 场地洒水降尘 施工扬尘 落实“八个百分百” 八个百分百 施 机械设备运行 加强设备及车辆维护, 工 废气及运输车 施工场地较开阔,扩散 加强设备及车辆维护 期 废气 辆废气 条件良好 选用符合国家规定质量 装修废气 要求的环保型油漆、涂 料、胶粘剂及装饰材料 减少对周边环 境的影响 50 使用环保型油漆、涂 料、胶粘剂及装饰材料 设置围挡,选用低噪声 设备及施工工艺,合理 布局,合理安排施工时 噪声 施工噪声 间,严禁夜间施工,车 辆进入敏感区域限速禁 鸣,定期对设备及车辆 围挡、低噪声设备及工 艺,合计布局,车辆进 入敏感区域限速禁鸣等 满足GB125232011《建筑施 工场界环境噪 20 声排放标准》 维护、养护,加强施工 队伍管理禁止高声喧哗 固废 生活垃圾 垃圾桶进行收集,由环 垃圾桶进行收集,由环 妥善安置,零 213 40 郸城县人民医院西南院区新建项目环境影响报告书 卫部门统一清运 第六章环境保护措施及其可行性论证 卫部门统一清运 排放 分类收集,可利用部分 分类收集,可利用部分 建筑垃圾 回收利用,不能利用部 回收利用,不能利用部 分运至指定建筑垃圾填 分运至指定建筑垃圾填 埋场 弃方 埋场 运至当地政府指定地点 运至当地政府指定地点 加强临时堆放场的管 理,制定土方表面压 实、定期喷水、覆盖、 生态 水土流失 设置截排水沟等措施; 不需要的泥土,建筑材 临时堆场压实、覆盖、 截排水沟,及时清运 减少水土流失 50 料弃渣应及时运走,不 宜长时间堆积 病区食堂废水经油水分 离器处理、病区化验室 医院地下总污水处理站 废水经酸碱中和处理后 710m3/d(地下)、病区 经过臭氧预消毒,然后 食堂油水分离器处理能 与化粪池+臭氧预消毒 力180m3/d、病区中和池 处理过的病区其他医疗 容积7m3、病区专用化 废水(门诊废水、 住 粪池+臭氧预消毒池 院病房废水、 医务人 430m3/d(容积1个 经处理后达到 员废水、空调冷凝水、 450m3、1个100m3、1个 《医疗机构水 蒸汽消毒废水)、隔油 45m3、1个500m3)、非 污染物排放标 运 营 废水 期 预处理过的非病区普通 病区食堂油水分离器处 综合废水 准》(GB 食堂废水、普通化粪池 理能力22m3/d、 18466-2005)表 处理过的非病区其他生 非病区普通化粪池 1标准和郸城县 活污水(后勤办公人员 35m3/d(容积1个30m3、 第三污水处理 废水、宿舍楼、空调冷 1个60m3)、车辆洗消 厂进水水质要 凝水)一起排入医院综 废水消毒池容积10m3, 求 合污水处理站进一步处 污水处理站处理工艺: 理达标后,汇入郸城县 “预消毒+格栅+调节池+ 第三污水处理厂,尾水 水解酸化+接触氧化 排入洺河。消毒蒸汽纯 +MBR膜池+次氯酸钠消 水制备浓水和非病区空 毒+脱氯池”,自动监测 调冷凝水作为清排水直 接排入医院总排口。 214 设施 180 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 病区含菌废气采用紫外 线杀毒后经专用排风烟 道引至楼顶排放;手术 室、负压病房采用全新 含菌废气 风直流式空调系统,送 风应经过初效、中效、 高效过滤器三级处理, 含菌气体经消 含菌废气紫外线杀毒、 毒后在室外经 全新风直流式空调系统 扩散和稀释后 三级过滤系统 50 对周边环境基 本无影响 排风经过高效过滤器过 滤处理后经过专用排风 烟道引至楼顶排放 经安全柜配套高效空气 过滤器处理后去除致病 细菌、生物气溶胶及其 他污染物有害气体后, 安全柜排风系统、高效 检验废气 再引至楼顶排放,同时 空气过滤器,经排气通 医院做好检验室内的消 道引至楼顶排放 对周边环境影 响较小 5 毒卫生工作,确保检验 废气处理后不会对周围 运 环境造成明显影响 营 废气 期 经1套高效静电式油烟 经1套高效静电式油烟净 后勤办公综合 净化器处理后经烟道引 化器处理后经烟道引至 满足河南省地 楼食堂油烟 至后勤办公综合楼楼顶 后勤办公综合楼楼顶排 方标准《餐饮 排放 放 经1套高效静电式油烟 经1套高效静电式油烟净 业油烟污染物 排放标准》 10 门诊医技综合 净化器处理后经烟道引 化器处理后经烟道引至 (DB41/1604楼食堂油烟 至门诊医技综合楼楼顶 门诊医技综合楼楼顶排 排放 机动车泊 车位汽车 尾气 污水处理站恶 臭气体 危废间废气 2018)大型 放 道路两侧加强绿化,地 道路两侧加强绿化,地 下车库设置抽排风系 下车库设置抽排风系 统,及时疏导进出泊车 统,及时疏导进出泊车 位车辆 周围环境影响 较小 20 位车辆 负压抽吸+生物除臭+紫 满足《恶臭污 外线消毒后经管道引至 1套负压抽吸+生物除臭 染物排放标 附近病房楼楼顶排放 +紫外线消毒后经管道引 准》(GB14554经管道引至污水站恶臭 措施处理排放 生活垃圾收集 仅收集,不处理不压 站恶臭 缩。垃圾袋装化,减少 215 至附近病房楼楼顶排放 8 93)表2 标准的要求 不处理不压缩,垃圾袋 满足《恶臭污 5 郸城县人民医院西南院区新建项目环境影响报告书 第六章环境保护措施及其可行性论证 垃圾暴露时间,及时清 装化,日产日清,使用 运,日产日清,使用除 除臭剂 臭剂 染物排放标 准》(GB1455493)表2 标准的要求 备用柴油发电 机废气 医务后勤人员 办公及宿舍产 生的普通生活 垃圾、废反渗 透膜 由自带的净化装置处理 后经管道引至附近构筑 物楼顶排放。 由自带的净化装置处理 周围环境影响 后经管道 较小 2 生活垃圾分类收集后, 日产日清,每天由环卫 部门负责清运至市政垃 垃圾箱若干,生活垃圾 圾中转站,最终运至郸 5 收集站95m2 城县生活垃圾焚烧厂发 电厂焚烧 采用专用餐厨垃圾收集 餐厨垃圾 固 废 桶收集,集中收集后交 专用餐厨垃圾收集桶若 由有资质的单位进行运 输处 置 医疗废物(门 诊、病房楼病 人产生的生活 垃圾) 得到合理处置 医疗废物暂存间50m2暂 存后,委托有资质单位 处置 污水站栅渣、 消毒压滤暂存后交由有 污泥 资质单位处理 废紫外线含汞 危废间暂存交由有资质 灯管 10 干 单位处置 医疗废物暂存间 20 (50m2) 危险废物暂存间 12 (25m2),污泥脱水间 (30m2) 满足《工业企 业厂界环境 噪声排放标 准》 噪 声 设备噪声 采取基础减振、消音降 基础减振、消音降噪、 噪、隔声等措施 隔声 (GB123482008)、《声 40 环境质量标 准》 (GB30962008)相关标 准要求 合计 216 532 郸城县人民医院西南院区新建项目环境影响报告书 第七章环境经济损益分析 第七章环境经济损益分析 7.1 环境经济损益的目的 环境经济损益分析是指通过对项目建设的经济效益、社会效益和环境效益 (包括项目环保措施费用效益)的分析论证,评价整个项目实施后对环境的总 题影响及环保措施方案的经济合理性,为工程建设的完善、合理提供依据。 本项目属于社会公益性设施,目的是为疾病患者提供专业的一站式人性化 的治疗康复服务。项目符合国家产业政策和相关规划的要求,对改善当地医疗 条件,更好地为人民群众健康服务,提高生活水平,适应现代化医疗科技进步, 促进社会和谐发展具有重要意义。由此可见,项目的建设和实施蕴含着巨大的 经济、社会和环境效益,在充分肯定这些正面效应的同时,项目积极开展污染 防治,加强环境保护,对施工期和营运期产生的环境影响因素采取了一系列治 理措施,由此可以实现环境、经济和社会效益的协调发展。 7.2经济效益分析 项目总投资 63480 万元,项目建成后共设置床位数 800 张。项目建成后将 会吸引附近居民病人来院就诊,为患者提供高水平的医疗服务,同时还为医院 创造一定的经济效益。本项目环保投资总计为 532 万元,占工程总投资 63480 万元的 0.84%,所占比例较小,不会增加建设方经济负担。根据项目可研,项 目正常运行后年均净利润 6155.26 万元,具备一定的盈利能力,这说明从财务 上来讲,项目的经济效益显著,是合理可行的。 7.3社会效益分析 医院是对公众或特定的人群进行治病防病的场所,是以诊治疾病、照护病 人为主要目的,以医疗服务为工作中心的医疗机构,因此它是城市重要的公共 服务设施,也是实现城市现代化的重要条件。本项目采取高起点规划建设,极 大改善本地区人民群众的就医环境,坚持平民化医疗收费,缓解“看病难、看病 贵”的社会难题。 217 郸城县人民医院西南院区新建项目环境影响报告书 第七章环境经济损益分析 项目为社会共提供了 1200 个就业岗位,对于缓解城市就业压力做出了一定 贡献。因此,本项目具有良好的社会效益。 7.4环境效益分析 根据工程分析和污染防治措施可知,本项目运营过程将产生一定的废水、 废气、固废,经采取评价单位提出的污染防治措施后,降低了各污染物的排放 量,实现了达标排放的要求。本项目污染防治措施实施后体现的环境效益分析 见表 7-1。 表 7-1 污染因素 本项目污染防治措施实施后带来的环境效益 治理措施 处理效果 环境效益 病区食堂废水经油水分离器 处理、病区化验室废水经酸 碱中和处理后经过臭氧预消 毒,然后与化粪池+臭氧预 消毒处理过的病区其他医疗 废水(门诊废水、 住院病房 经污水处理站处理后能达 废水、 医务人员废水、空调 到《医疗机构水污染物排 废 综合废 水 水 冷凝水、蒸汽消毒废水)、 放标准》(GB 减少医疗废水 隔油预处理过的非病区普通 18466-2005)表1传染 直接排放对地 食堂废水、普通化粪池处理 病、结核病医疗机构水污 表水和地下水 过的非病区其他生活污水 染物排放浓度、最高允许 造成的不利影 (后勤办公人员废水、宿舍 排放负荷标准要求和郸城 响 楼、空调冷凝水)一起排入 县第三污水处理厂进水水 医院综合污水处理站进一步 质要求 处理达标后,汇入郸城县第 三污水处理厂,尾水排入洺 河。消毒蒸汽纯水制备浓水 和非病区空调冷凝水作为清 排水直接排入医院总排口。 病区含菌废气采用紫外线杀 毒后经专用排风烟道引至楼 废 气 含菌废气 顶排放;手术室、负压病房 采用全新风直流式空调系 统,送风应经过初效、中 效、高效过滤器三级处理, 218 含菌气体经消毒后在室外 经扩散和稀释后对周边环 境基本无影响 减少对周边大 气环境影响 郸城县人民医院西南院区新建项目环境影响报告书 第七章环境经济损益分析 排风经过高效过滤器过滤处 理后经过专用排风烟道引至 楼顶排放 经安全柜配套高效空气过滤 器处理后去除致病细菌、生 物气溶胶及其他污染物有害 检验废气 气体后,再引至楼顶排放, 同时医院做好检验室内的消 对周边环境影响较小 减少对周边大 气环境影响 毒卫生工作,确保检验废气 处理后不会对周围环境造成 明显影响 后勤办公综合楼 食堂油烟 门诊医技综合楼 食堂油烟 机动车泊车位汽 车尾气 地下污水处理站 恶臭气体 危废间废气 器处理后经烟道引至后勤办 满足河南省地方标准《餐 公综合楼楼顶排放 经1套高效静电式油烟净化 器处理后经烟道引至门诊医 饮业油烟污染物排放标 准》 (DB41/1604-2018)大型 技综合楼楼顶排放 库设置抽排风系统,及时疏 量,改善了食 堂操作间工 作环境,同时 也减少了对外 环境的不利 影响 道路两侧加强绿化,地下车 周围环境影响较小 导进出泊车位车辆 减少对周边大 气环境影响 负压抽吸+生物除臭+紫外线 消毒后经管道引至附近病房 满足《恶臭污染物排放标 楼楼顶排放 准》(GB14554-93)表2 经管道引至污水站恶臭措施 标准的要求 减少对周边大 气环境影响 处理排放 仅收集,不处理不压缩。垃 生活垃圾收集站 圾袋装化,减少垃圾暴露时 恶臭 减少油烟排放 经1套高效静电式油烟净化 间,及时清运,日产日清, 满足《恶臭污染物排放标 准》(GB14554-93)表2 标准的要求 使用除臭剂 减少对周边大 气环境影响 废气排放情况可以满足河 备用柴油发电机 废气 由自带的净化装置处理后经 南省地方标准《餐饮业油 管道引至附近构筑物楼顶排 烟污染物排放标准》 放。 (DB41/1604-2018)排 放要求 219 减少对周边大 气环境影响 郸城县人民医院西南院区新建项目环境影响报告书 第七章环境经济损益分析 分类收集后,日产日清,每 医务后勤人员办 天由环卫部门负责清运至市 公及宿舍产生的 政垃圾中转站,最终运至郸 普通生活垃圾 城县生活垃圾焚烧厂发电厂 焚烧 废反渗透膜(纯 更换后随生活垃圾一同交环 水制备) 固 废 卫部门清运处理 合理处置 采用专用餐厨垃圾收集桶收 餐厨垃圾 减少医疗废物转运过程中携带的病原菌 集,集中收集后交由有资质 对环境影响的风险,避免对环境造成二 的单位进行运输处 置 次污染 门诊、病房楼病 安装医疗废物要求进行暂存 人产生的生活垃 管理和处置,定期交由有资 圾及医疗废物 质单位进行清运处置 污水站栅渣、污 消毒脱水后,作为危险废物 泥 定期交有资质单位处置 废紫外线含汞灯 危废间暂存交由有资质单位 管 处置 满足《工业企业厂界环境 噪 设备噪 采取基础减振、消音降噪、 噪声排放标准》 声 声 隔声等措施 (GB12348-2008)1类、 4a 减轻对医院和 周围环境产生 的影响 由表 7-1 看出,本项目采取的污染防治措施使工程存在的环境问题得以解 决,减小了医院排污对外环境的不利影响。 本项目总投资为 63480 万元,其中环保投资 532 万元,环保投资占总投资 的比例为 0.84%,通过环保投资建设,控制了项目的产污和排污,也达到了环 保设施与主体工程同时设计、同时施工、同时投产的要求,投资比例适宜。 7.5环境经济损益分析 7.5.1 环保工程投资概算 根据污染防治措施评价分析结果,本项目必须落实的环保设施及各项设施 资金见表 7-2。 表 7-2 环保设施及各项设施资金一览表 序号 项目 工程投资(万元) 1 污水治理设施 185 220 郸城县人民医院西南院区新建项目环境影响报告书 第七章环境经济损益分析 2 废气治理设施 150 3 固体废物 87 4 噪声治理 60 5 生态 50 532 合计 由表 7-2 可知,本项目完成后环保总投资为 532 万元,占项目总投资 63480 万元的 0.84%。 7.5.2 运营期环保支出 本项目运营期环保设施运营支出包括环保设施运行费、折旧费、管理费等。 (1)环保设施运行费(C1) 工程污染防治措施主要的运行费用主要包括电费,其中废水治理运行费用 49.4 万元,废气处理年运行费用约 25 万元,则本项目环保设施年运行费用为 74.4 万元。 (2)环保设施折旧费(C2) C2=a*C0/n=17.1(万元) 式中,a——固定资产形成率,取 95%; n——折旧年限,取 10 年; C0——环保投资。 (3)环保管理费(C3) 环保管理费包括管理部门的办公费、监测费和技术咨询费等,按环保设施 运行费与折旧费的 5%计算。 C3=(C1+C2)×5%=4.575(万元) (4)环保运行管理费(C) C=C1+C2+C3=96.075(万元) 本项目环保设施运营支出费用为 96.075 万元。 7.5.3 项目环境经济损益分析 (1)环保投资费用占建设投资比例 环保投资/总投资 532/63480=0.84% 221 郸城县人民医院西南院区新建项目环境影响报告书 第七章环境经济损益分析 (2)环保设施运营支出费占净利润比例 环保设施运营支出费/净利润=96.075/6155.26=1.56% (3)环境经济总体效益 环境经济总体效益=工程总经济效益-环境代价-环保运行管理费用 =6155.26-96.075=6059.185(万元) 由以上计算结果可以看出,本项目每年环境经济总体效益为 6059.185 万元, 从经济分析结果可以看出,本项目的环境经济效益良好。 7.6结论 综上所述,从经济效益、社会效益和环境效益三方面进行综合分析,项目 建成后,能带动当地医疗卫生事业发展,使郸城县域医院基础设施建设和基本 医疗的组成部分更加完善,提高区域基础医疗水平,为周围群众提供更好的就 医条件,从而提高全地区的整体健康水平;将会在人口就业、医疗服务及本地 经济发展等方面产生正效益,而项目的建设及运营期间导致的环境方面的负面 影响,在保障科学的管理、保证资金的合理利用的前提下,通过各项环保措施 的有效实施,使项目各类污染源及污染物排放符合环保部门的管理要求,从环 措施的经济损益效果来看,项目是可行的。 222 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 第八章产业政策相符性及厂址可行性分析 8.1与产业政策和相关规划符性分析 8.1.1 与产业政策相符性分析 根据《产业结构调整指导目录(2019 年)》,本项目属于其中的鼓励类第 三十七条“卫生健康”中 6、“传染病、儿童、精神卫生专科医院和康复医院 (中心)、护理院(中心、站)、安宁疗护中心、全科医疗设施建设与服务” 项目;本项目属于《国民经济行业分类》(GB/T4754-2017)中“Q8415 专科医 院”,根据《郸城县发展和改革委员会关于郸城县人民医院西南院区新建项目可 行性研究报告的批复》(郸发改社会[2022]202 号)(见附件 2),郸城县发 展和改革委员会已同意郸城县人民医院西南院区新建项目的建设。因此,本项 目的建设符合国家产业政策。 8.1.2 与行业政策符合性分析 8.1.2.1 与《周口市加快补齐医疗机构污水处理设施短板提高污染治理能力工作方案》 (周环文[2021]105 号)相符性分析 本项目位于郸城县科技大道北、公园西路西侧地块,目前现状为空地,尚 未开工建设,因此,目前不在《周口市加快补齐医疗机构污水处理设施短板提 高污染治理能力工作方案》(周环文[2021]105 号)的工作对象范围内,但本项 目建设将参照(周环文[2021]105 号)文件相关要求进行规范化建设。本项目与 《周口市加快补齐医疗机构污水处理设施短板提高污染治理能力工作方案》 (周环文[2021]105 号)相符性分析见表 8-1。 表 8-1 类别 本项目与(周环文[2021]105 号)相符性分析一览表 周环文[2021]105号文相关要求 本项目 相符性 尚未配置污水处理设施及现有 工作 目标 处理设施能力不足的医疗机 本项目建设处理规模710m3/d污水 构,要结合医院发展规划,合 处理设施能够满足本项目污水处 理确定新建、改扩建污水处理 相符 理需求 设施。 全面开展排查 医疗机构是医疗污水处理的责 项目建成后共800张。属于文件 任主体,应依据有关法律规范 中划分的三级医疗机构,本项目 223 相符 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 以及排污许可证要求,开展医 将严格按周环文[2021]105号文件 疗污水处理设施建设运维情况 相关要求进行建设。①污水处理 自查。重点对污水处理能力、 能力710m3/d污水处理设施污水处 污水处理工艺、污水管网建 理能力满足要求;②污水处理工 设、污水处理设施运维管理及 艺、污水管网建设:处理工艺为 达标排放、污泥与恶臭处置等 “预消毒+格栅+调节池+水解酸化 情况,进行系统排查,切实掌 +接触氧化+MBR膜池+次氯酸钠 握存在问题,认真填报医疗机 消毒+脱氯池”,本项目排水实行 构污水处理登记表、污水处理 雨污分流、污污分流。雨水直接 设施建设运维情况自查表、污 排入市政雨水管网,病区食堂废 水处理问题清单。2022年1月20 水经油水分离器处理、病区化验 日前,传染病医疗机构(含定 室废水经酸碱中和处理后经过臭 点医院)、二级及以上医疗机 氧预消毒,然后与化粪池+臭氧 构完成自查;2023年3月20日 预消毒处理过的病区其他医疗废 前,其他医疗机构完成自查。 水(门诊废水、 住院病房废水、 医务人员废水、空调冷凝水、蒸 汽消毒废水)、隔油预处理过的 非病区普通食堂废水、普通化粪 池处理过的非病区其他生活污水 (后勤办公人员废水、宿舍楼、 空调冷凝水)一起排入医院综合 污水处理站进一步处理达标后, 汇入郸城县第三污水处理厂,尾 水排入洺河。消毒蒸汽纯水制备 浓水和非病区空调冷凝水作为清 排水直接排入医院总排口。因 此,污水处理工艺及管网满足要 求;③污水处理设施运维管理及 达标排放:建立污水处理运行台 账、总余氯等指标安装使用自动 监测设备,满足达标排放要求; ④污泥:清掏前进行监测,经消 毒、脱水后委托具有危险废物处 理处置资质的单位进行集中处 置,满足要求;⑤恶臭气体污水 处理站为地下式,污水处理站上 方为封闭式房间,且各个污水处 理单元加盖封闭,设导气管将污 224 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 水处理装置溢出臭气进行收集, 然后采用1套“生物除臭+紫外线 消毒”处理后经管道引至附近病 房楼楼顶排放(20m高),满足 要求;⑥紧临污水处理站东 侧 设置1座应急事故池600m3,满 足要求。 各县(市、区)要按照有关规 定,对医疗机构实行排污许可 重点管理和纳入重点排污单位 名录,督促其对总余氯等指标 安装使用自动监测设备,并与 当地生态环境部门联网。医疗 机构可以委托第三方开展设施 运行维护和监测医疗机构要切 实履行污染治理主体责任,健 全污水处理管理责任制,将污 水处理设施运行维护纳入医疗 机构日常管理工作,组建既熟 强化日常管理 悉政策要求又具备较强业务能 力的专业队伍,依法建立健全 医疗机构污水处理设施运行台 账制度,落实岗位职责,规范 记录进出水水量、水质、消毒 药剂类型和使用量等信息。位 于室内的污水处理工程必须设 有强制通风设备,并为工作人 员配备工作服、手套、面罩、 项目建成后共800张,排污许可 管理类别属于重点管理,本项目 建成运营后将进行排污许可申 请。拟对流量、总余氯等指标安 装使用自动监测设备,并与当地 生态环境部门联网将污水处理设 施运行维护纳入医疗机构日常管 理工作,建立医疗机构污水处理 相符 设施运行台账制度,落实岗位职 责,规范记录进出水水量、水 质、消毒药剂类型和使用量等信 息。位于室内的污水处理工程必 须设有强制通风设备,并为工作 人员配备工作服、手套、面罩、 护目镜、防毒面具以及急救用品 护目镜防毒面具以及急救用 品。鼓励有条件的医疗机构提 高污水处理设施自动化运行水 平,减少工作直接或间接接触 污水的风险。 综上所述,本项目建设符合《周口市加快补齐医疗机构污水处理设施短板 提高污染治理能力工作方案》(周环文[2021]105 号)的相关要求。 225 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 8.1.2.2 与《传染病医院建筑设计规范》(GB50849-2014)相符性分析 《传染病医院建筑设计规范》(GB50849-2014)适用于新建、改建和扩建 的传染病医院的建筑设计。项目建设分析符合《传染病医院建筑设计规范》 (GB50849-2014)中强制性条文,具体的相符性分析如下: 表 8-2 项目与《传染病医院建筑设计规范》(GB50849-2014)相符性 规范要求 本项目 相符 性 项目选址符合郸城县城市规划,已 4.1.1 新建传染病医院选址应符合当地城镇 规划、区域卫生规划和环保评估的要求。 取得郸城县自然资源局的用地预审 与选址意见书,符合郸城县区域卫 相符 生规划,根据环评预测项目各项污 染的排放符合国家及行业的要求 4.13 新建传染病医院选址,以及现有传染 病医院改建和扩建及传染病区建设时,医 疗用建筑物与院外周边建筑应设置大于或 等于 20m 绿化隔离卫生间距 5.2.4 门诊部应按肠道、肝炎、呼吸道门诊 等不同传染病种分设不同门诊区域,并应 分科设置候诊室、诊室 5.3.2 急诊部入口处应设置筛查区(间), 并应在急诊部入口毗邻处设置隔离观察病 区或隔离病区 5.5.2 平面布置应划分污染区、半污染区与 清洁区,并应划分洁污人流,物流通道 本项目为传染病医院,院区周边为 农田、村庄,厂界距离北侧最近村 庄 178m,医院医疗建筑物距离东 侧郸城县气象局构筑物 144m,满 足 20m 绿化隔离卫生间距的要求 项目门诊部后期建设中应按肠道、 肝炎、呼吸道门诊等不同传染病种 分设不同门诊区域,并设分科设置 本项目急诊部入口处在设计时急诊 部入口处设置筛查区(间),并在 急诊部入口毗邻处设置隔离观察病 本项目在设计时平面布置划分污染 区、半污染区与清洁区,并划分洁 分别安排在传染病楼的不同病区 设双门密闭式传递窗 5.7.1 应按衣服、被单的洗涤、消毒、烘 干、折叠加工流程布置,污染的衣服、被 单接受清洁的衣服、被单发送口应分开设 置 相符 污人流,物流通道 病区 手动式或自动感应式洗手池,过道墙上应 相符 区或隔离病区 本项目在设计时不同类传染病病人 与病房之间应设置缓冲前室,并应设置非 相符 候诊室、诊室。 5.5.6 不同类传染病病人应分别安排在不同 5.5.9 呼吸道传染病病区,在医护人员走廊 相符 相符 本项目在设计呼吸道传染病病区, 在医护员走廊与病房之间设置缓冲 前室,并设置非手动式或自动感应 相符 式洗手池,过道墙上设双门密闭式 传递窗 本项目衣服、被单委托第三机构进 行洗涤,污染的衣服、被单接受清 洁的衣服、被单发送口应分开设置 226 相符 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 本项目在设计时按照相关要求对太 5.8.4 太平间、病理解剖室、医疗垃圾暂存 平间、病理解剖室、医疗垃圾暂存 处的地面与墙面,均应采用耐洗涤消毒材 处的地面与墙面,均采用耐洗涤消 料,地面与墙裙均应采取防昆虫、防鼠雀 毒材料,地面与墙裙均采取防昆 以及其他动物侵入的措施 虫、防鼠雀以及其他动物侵入的措 相符 施 7.1.3 传染病医院或传染病区应设置机械通 本项目在设计时对病房区设置机械 风系统 通风系统 7.1.4 医院内清洁区、半污染区、污染区的 机械送、排风系统应按区域独立设置 相符 本项目在设计时对医院内清洁区、 半污染区、污染区的机械送、排风 相符 系统按区域独立设置 8.1.2.3 与《传染病医院建设标准》(建标 173-2016)相符性分析 根据分析,本项目建设符合《传染病医院建设标准》(建标 173-2016)的 相关要求,具体分析如下: 表 8-3 项目与《传染病医院建设标准》(建标 173-2016)相符性 本项目 相 符 性 本项目已由郸城县发展和改革委员会批 复,批复文号为郸发改社会[2022] 202 号。根据当地规划、区域卫生规划 等确定设置 800 个床位 符 合 规范要求 第八条新建传染病医院的建设规模应根据 当地城乡总体规划、区域卫生规划、医疗 机构设置规划、经济发展水平、卫生资 源、传染病发病率和服务需求状况进行综 合平衡后确定 第十二条建设规模 250~399 床的,建筑面 2 积指标为 80m /床 第十八条新建传染病医院应配套建设机动 车和非机动车停车设施 第二十条 一、不宜设置在人口密集区域。 二、患者就医方便、交通便利地段。 三、地形比较规整,工程水文地质条件较 好。四、有比较完善的市政公用系统。 五、不应临近易燃、易爆及有害气体生 产、贮存场所,不应临近水源地。 六、不应临近食品和饲料生产、加工、贮 存,家禽、家畜饲养、产品加工等企业。 七、不应临近幼儿园、学校等人员密集的 公共设施或场所。 第二十五条新建传染病医院绿地率不宜低 本项目设置 800 床,床均建筑面积指标 2 为 134.57m /床 本项目配套建设机动车和非机动车停车 设施,共设机动车停车位 1140 个 项目东侧紧邻公园西路,交通方便,项 目周边主要为农田和村庄,环境相对安 静,且周边区域无污染源,不属于人口 密集区域;本项目的用地规整,项目位 于郸城县县城的西侧,郸城县地形西高 东低,项目所处区域地势较高,地质条 件稳定,不会收到洪水威胁;项目所在 地周边无密集人群;项目选址有比较完 善的市政供水、排水、电力等公用系 统;周边无易燃易爆产品生产、储存区 域及存在卫生污染风险的生产加工区; 不临近幼儿园、学校等人员密集的公共 设施或场所(距离西侧学校巴集五七高 中 870m,距离较远) 本项目绿地率 35% 227 符 合 符 合 符 合 符 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 于 35% 第四十四条 传染病医院应建设医院污水、固体污物的 处理设施,医院污水的排放和医疗废物与 生活垃圾的分类、收集、存放与处置应按 现行国家标准《医疗机构水污染物排放标 准》GB18466、《医疗废物管理条例》等 国家有关法律、法规和标准执行 合 本项目建设污水、固体污物的处理设施 (1 座污水处理站 710m3/d、1 处 50m2 医疗废物暂存间、1 处 25m2 危废暂存 间),医院污水的排放和医疗废物与生 活垃圾的分类、收集、存放与处置应按 现行《医疗机构水污染物排放标准》 GB18466、《医疗废物管理条例》等国 家有关法律、法规和标准执行 符 合 8.1.2.4 与《医院污水处理工程技术规范》(HJ2029-2013)相符性分析 本项目建设符合《医院污水处理工程技术规范》(HJ2029-2013)中对传染 病医院水处理技术的要求,具体分析如下: 表 8-4 与《医院污水处理工程技术规范》(HJ2029-2013)相符性 相 技术规范要求 本项目 符 性 4.1.2 新(改、扩)建医院,在设计医院 污水处理系统时应考虑将医院病区、非病 本项目医院废水病区、非病区、传染病 相 房、非传染病房污水分类收集。 符 区、传染病房、非传染病房污水分别收集 4.1.3 特殊性质污水应单独收集,经预处 检验科废水单独收集,经中和预处理后 理后与医院污水合并处理,不得将特殊性 与医院其他污水合并进医院污水处理站 质污水随意排入下水道。 处理 4.2.4 医院污水处理工程设计水量应在实 相 符 本项目污水处理站按测算值的 2 倍裕量 相 设计 符 5.1.5 医院污水处理工程排水宜采用重力 本项目污水处理站采用重力流排放,必 相 流排放,必要时可设排水泵站。 要时设置排水泵站 符 5.1.6 医院污水处理构筑物应采取防腐 本项目污水处理站构筑物采取防腐蚀、 蚀、防渗漏、防冻等技术措施,各种构筑 防渗漏、防冻等技术措施,设于地下, 物宜加盖密闭,,并设通气装置。 各种构筑物加盖密闭,并设通气装置 6.1.2 传染病医院污水应在预消毒后采取 项目污水处理站处理工艺设计为“预消 二级处理+消毒工艺或二级处理+深度处理+ 毒+格栅+调节池+水解酸化+接触氧化 消毒工艺 +MBR 膜池+次氯酸钠消毒+脱氯池”工艺 测或测算的基础上留有设计裕量,宜取实 测值或测算值的 10-20% 6.3.1.2 预消毒池:传染病医院污水预消 毒宜采用臭氧消毒。消毒时间应不小于 消毒,处理出水再生回用或排入地表水体 符 相 符 项目预消毒采用臭氧消毒。消毒时间不 相 小于 30min 符 本项目污水处理站污水预消毒采用臭氧 相 消毒 符 30min。 6.3.4.2 传染病医院污水应优先采用臭氧 相 时应首选臭氧消毒 6.3.5.1 污泥消毒一般采用化学消毒方 本项目污泥消毒采用生石灰 式。常用的消毒药剂为石灰和漂白粉 228 相 符 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 本项目针对污水处理站废气采取的措施 为:污水处理站地下式+各个污水处理 单元(格栅池、调节池、水解酸化池、 6.3.6.1 医院污水处理工程废气应进行适 当的处理(如臭氧活性炭吸附等方法)后 排放不宜直接排放 生物接触氧化池、二沉池、污泥槽等) 相 进行密封加盖(盖板预留进、出气口) 符 +设导气管集气+生物除臭+紫外消毒+经 管道引至附近病房楼楼顶排放(20m 高) 8.1.2.5 与《医疗废物处理处置污染控制标准》(GB39707-2020)相符性分析 本项目建设符合《医疗废物处理处置污染控制标准》(GB39707-2020)中 对医疗废物贮存的要求,具体分析如下: 表 8-5 项目医疗废物贮存与(GB39707-2020)要求相符性 技术规范要求 本项目 5.4.1 医疗废物处理处置单位应设置感染性、 损伤性、病理性废物的贮存设施;若收集化学 性、药物性废物还应设置专用贮存设施。贮存 设施内应设置不同类别医疗废物的贮存区。 5.4.2 贮存设施地面防渗应满足国家和地方有 关重点污染源防渗要求。墙面应做防渗处理, 感染性、损伤性、病理性废物贮存设施的地 面、墙面材料应易于清洗和消毒 5.4.4 感染性、损伤性、病理性废物贮存设施 应设置微负压及通风装置、制冷系统和设备, 排风口应设置废气净化装置 项目医废暂存间内医疗废物设置 专用贮存设施,贮存设施内设置 不同类别医疗废物的贮存区进行 分类贮存 医疗废物暂存库采用重点防渗处 理,地面、墙面与裙脚要用坚 固、防渗的材料建造,易于清洗 和消毒 项目医疗废物暂存间内设置微负 压和通风装置,制冷系统和设 备,同时设置废气净化装置 项目医疗废物应按照文件要求在 不能及时处理处置时,应置于贮 存设施内贮存。感染性、损伤 性、病理性废物应盛装于医疗废 物周转箱/桶内一并置于贮存设 施内暂时贮存 化学性,药物性废物按照《危险 废物贮存污染控制标准》 (GB18597—2023),要求进行处置 和贮存 5.4.5 医疗废物不能及时处理处置时,应置于 贮存设施内贮存。感染性、损伤性、病理性废 物应盛装于医疗废物周转箱/桶内一并置于贮 存设施内暂时贮存 5.4.7 化学性、药物性废物贮存应符合 GB18597 的要求 8.1.3 与相关规划符合性分析 229 相 符 性 符 合 符 合 符 合 符 合 符 合 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 8.1.3.1《郸城县城市总体规划修编(2017-2030)》 《郸城县城市总体规划修编(2017-2030)》由浙江省城乡规划设计研究院 于 2018 年完成编制,是郸城县目前实施的城市总体规划。其主要内容如下: ①城市性质:豫皖交界的特色商贸物流中心和工业基地;县域经济文化政 治中心;生态宜居的健康城市。 ②城市发展方向:东延西进、南拓北控,近期生活向西、远期向南发展, 工业向东发展。 ③布局结构:中心城区总体形成“一带一环双轴、双核四心五片区”的结构。 一带指洺河历史文化旅游发展带;一环指围绕世纪大道、财鑫大道、方远 北路形成的公共服务集聚环;双轴指世纪大道和科技大道城市发展轴; 双核:指城市主中心及老城副中心两个城市核心;四心:三个城市片区级 中心及一个特色专业中心,分别指城北片区中心、产业集聚区中心、城南片区 中心及专业市场中心。五片区:指城市老城片区、城西片区、城南片区、城北 片区及产业集聚区五大城市片区。 ④居住用地布局:产业配套居住片区,规划居住用地 140.1hm2,人口规模 3.9 万人。 ⑤基础设施规划: 1)给水规划 保留现状第一水厂,位于文化路北段西侧,规模为 1 万 m3/d,占地 11 亩。 保留现状第二水厂,总规模 6 万 m3/d,位于西三环路与交通路交叉口东南 角,占地 40 亩。 在东部产业园新建第三水厂,位于片区西北角,郸淮公路以南、东环路以 东,规模 10 万 m3/d,供水范围为城区东部和北部。 规划在污水处理厂设深度处理装置,主要供应东部产业集聚区的工业用水, 规划再生水生产规模 4.0 万 m3/d。 2)排水规划 230 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 规划保留现有污水一厂、二厂。一厂规模 3 万 m3/d,二厂 6 万 m3/d。再配 套 4.0 万 m3/d 的中水处理规模。 污水处理一厂,位于郸城县东工业园区南端、洺河北岸,污水规模为 3.0 万 m3/d,占地 54 亩,主要处理生活污水和部分工业污水,处理标准为一级 A 标准。污水厂升级改造后,进行了再生水回用工程建设,2.65 万 m3/d 再生水主 要用于造纸、热电、化工企业的冷却用水。 污水处理二厂于位于郸城县产业集聚区东南部、东外环路西侧,洺河南岸。 处理标准为一级 A 标准,尾水排入洛河。另配套建设 4 万 m3/d 再生水厂。 洺河以北,该片区内有杨白沟等水系,区内雨水就近排入河流水渠。 洺河以南,区内雨水就近排入柿园沟、府东河、劳武河。 3)燃气规划 郸城县已建郸城门站(含 CNG 加气站)1 座,供气规模为 3.0 亿 m3/a。站 址位于 329 国道与郸淮路交口处,占地面积为 13036m2 ;该门站接自上游西气 东输淮阳-郸城-鹿邑段输送的天然气。 规划郸城城区采用次高压管道给加气站和用气量较大的工业用户直接供气, 采用中压一级输配系统供气方案给居民、商业及一般工业供气,对用户采用区 域调压站、调压柜(楼栋调压箱)、专用调压站相结合的方式供气。 4)供热规划 根据郸城实际,规划确定东、西 2 处作为集中供热的公用热源。 根据现场调查,金丹乳酸热电分厂有作为公用热源的条件,热电厂留有扩 建的用地,目前锅炉装机规模为 75t/h2 台,40t/h1 台,热电厂可根据热负荷增 加扩建规模,供应规划区东部区域以及工业区。 另外,本规划建议在城区西南侧新建 1 座区域锅炉房,作为郸城第二热源, 近期规模可选 2×70MW 高温热水锅炉,远期扩建规模,增加 3 台 168MW 高温 热水锅炉,最终规模供热能力达 650MW,供应规划区西南部区域。区域锅炉房 占地约 3.5 万 m2。 231 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 在无法实施集中供热的区域,积极采用太阳能、地热、电能、天然气等多 种环保型供热方式。 5)环保规划 水环境保护目标:确保县城污水处理厂和污水管网建成后稳定运行。饮用 水水质全面达标,城市污水实行集中处理。加强水资源保护,河流水质达到 《地表水环境质量标准》(GB3838-2002)Ⅲ类和 V 类水类标准,县城主要河 流断面水质监测达标率保持 100%。 大气环境保护目标:组织实施好大气污染防治行动计划工作,县城城市环 境空气中 SO2、NO2、可吸入颗粒物的日均值严格控制在《环境空气质量标准》 (GB3095-2012)表 1 中的二级标准浓度限值。 声环境保护目标:居住区、行政办公、科研、医疗卫生及公园、旅游开发 区噪声控制在 50 分贝以下。商业居住和工业混合区、体育中心、商业中心及高 新技术工业区等不超过 60 分贝,对外及过境交通干道及设施、二、三类工业区 内不超过 70 分贝。 固体废弃物治理目标:县城城市生活垃圾无害化处理率达到 80%以上。依 法加强对固体废弃物的管理,特别是对危险废弃物的管理,确保危险废弃物得 到妥善安全处置,实现医疗垃圾无害化处理,加强对工业固体废弃物的利用研 究,提高综合利用率。加强现有固体废物处理(处置)场二次污染的防治。 生态环境目标:生态环境恶化趋势得到基本遏制;生态县建设工作得到大 力推进;生态环境状况指标符合上级规定要求。 ★本项目符合性分析: 项目地块位于郸城县科技大道北、公园西路西侧地块。根据 2022 年 6 月 5 日郸城县县政府常务会议纪要[2022]40 号,会议同意划拨郸城县科技大道北、 公园西路西侧地块用于实施郸城县人民医院西南院区新建项目。 郸城县自然资源局已于 2022 年 6 月 16 日核发本项目的建设项目用地预审 与选址意见书,编号为用字第 411625202200024。 232 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 根据附图 13 项目地块控制性详细规划,项目用地已调整为医疗卫生用地。 项目建设符合郸城县用地规划和城市总体规划。 8.1.3.2《郸城县污染防治攻坚战领导小组办公室关于印发郸城县 2022 年大气、水、土 壤污染防治攻坚战及农业农村污染治理攻坚战实施方案的通知》(郸环攻坚办〔2022〕 7 号) 本项目建设符合《郸城县污染防治攻坚战领导小组办公室关于印发郸城县 2022 年大气、水、土壤污染防治攻坚战及农业农村污染治理攻坚战实施方案的 通知》(郸环攻坚办〔2022〕7 号),具体分析如下: 表 8-6 与郸环攻坚办〔2022〕7 号相符性 序号 郸城 县 2022 年 大气 污染 防治 攻坚 战实 施方 案 相关要求 本项目情况 相 符 性 推进绿色低碳产业发展。落实国家产业规划、产业政 策、“三线一单”、规划环评,以及产能置换、煤炭消 费减量替代、区域污染物削减等相关要求,积极支持 节能环保、新能源等战略性新兴产业发展,坚决遏制 高耗能、高排放项目盲目建设。落实“两高”项目会商 联审机制,强化项目环评及“三同时”管理,重点行业 企业新建、扩建项目达到 A 级绩效水平,改建项目达 到 B 级以上绩效水平。严禁新增钢铁、焦化、铸造、 烧结砖瓦、铁合金等行业产能。禁止耐火材料、铅锌 冶炼(含再生铅)行业单纯新增产能。水泥行业产能 置换项目应实现矿石皮带廊密闭运输,大宗物料产品 清洁运输 项目符合产业政 策、“三线一单” 相 要求。项目强化 符 环评及“三同时” 管理。 实施清洁能源替代。大力推进清洁能源应用,鼓励支 持现有使用高污染燃料的工业炉窑改用工业余热、电 能、天然气等,对 2024 年 10 月底前完成拆改任务的 工业炉窑,优先给予大气污染防治专项资金支持。 新、改、扩建加热炉、热处理炉、干燥炉、熔化炉等 工业窑炉,应采用清洁能源。全县禁止新建企业自备 燃煤锅炉,全面淘汰 35 蒸吨/小时及以下的燃煤锅 炉。淘汰方式主要包括拆除、实施集中供热替代、煤 改气、煤改电等,以拆除方式淘汰的,必须拆除炉体 或物理切断管道,使其不具备复产条件。 本项目不设锅 符 炉、工业炉窑, 合 主要使用电能 提升扬尘污染防治水平。实施扬尘治理智慧化提升工 程,持续推进扬尘治理监控平台建设,加强国、省道 道路扬尘监控能力建设,逐步纳入省级监控平台。深 入开展扬尘治理专项行动,严格落实《城市房屋建筑 项目施工期扬尘 治理按照最新环 符 保要求执行。餐 合 厅油烟安装油烟 233 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 和市政基础设施工程及道路扬尘污染差异化评价标 准》《河南省房屋建筑和市政基础设施工程扬尘治理 监控平台数据接入标准》要求,对扬尘重点污染源实 行清单化动态管理,强化开复工验收、“三员”管理、 “两个禁止”等扬尘治理制度机制,实施渣土车密闭运 输、清洁运输,完善降尘监测和考评体系。持续做好 城市公共道路清扫保洁,加大专业道路清扫机械的配 备和使用,有效提升国省道、县乡道路、城乡结合部 和背街小巷等各类道路清扫保洁效果,对城市公共区 域、长期未开发建设裸地,以及废旧厂区、物流园、 大型货车停车场等进行排查建档并采取防尘措施。大 型物料堆场全面完成抑尘设施建设和物料输送系统封 闭改造。加强餐饮油烟污染治理,强化日常监督管 理,规范治理设施运行管理,现场监管月抽查率不低 于 20%。 全面提升固体废物监管能力。鼓励各乡(镇)开展 郸城县 “无废城镇”建设,全面加强固体废物治理体系和能力 2022 年 建设。持续开展危险废物专项整治,全面提升危险废 土壤污 物环境监管、利用处置和环境风险防范“三个能力”, 染防治 推动危险废物监管和利用处置能力改革工作。加快推 攻坚战 进医疗废物和危险废物集中处置项目建设。动态更新 实施方 危险废物产生、自行利用、经营、监管“四个清单”, 案 有序推进固废监管信息化建设。探索铅酸蓄电池收集 试点工作。 净化装置进行处 理 项目后期应加强 固体废物管理, 全面提升医疗废 物环境监管、利 符 用处置和环境风 合 险防范“三个能 力”,做好医疗废 物监管和利用处 置工作 8.1.3.3“三线一单”符合性分析 (1)生态保护红线 本项目位于郸城县科技大道北、公园西路西侧地块,周边无自然保护区、 饮用水源保护区等生态保护目标,符合生态保护红线要求。 (2)资源利用上线:本项目使用自来水,不设置自备水井,当地自来水厂 能够满足本项目用水需求;食堂天然气由市政天然气管道统一供应,用电由市 政供电,本项目不触及资源利用上线。 (3)环境质量底线:2022 年郸城县 PM2.5、PM10 年均浓度超标,其他因子 达标,随着大气攻坚战的实施,大气质量将有所改善。项目属于医院项目,营 运期所产生的噪声、废水、废气(主要是污水站恶臭和食堂油烟)等环境污染, 234 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 采取应的环保措施后,对周围环境的影响较小,因此项目建设符合环境质量底 线要求。 (4)生态环境准入清单:本项目位于郸城县科技大道北、公园西路西侧地 块。根据《河南省生态环境准入清单》以及周口市生态环境局《关于发布<周口 市“三线一单”生态环境准入清单(试行)>的函》(周环函【2022】03 号),项目 所在地管控单位编号为 ZH41162530001,属于郸城县一般管控单元。项目符合 “三线一单”及本项目所在管控单元生态环境准入清单要求。 表 8-7 环境 环境 管控 管控 单元 单元 编号 名称 与郸城县环境管控单元生态环境准入清单相符分析 管控 相 单元 管控要求 本项目情况 分类 符 性 1. 严禁在优先保护类耕地集中区域 新建有色金属冶炼、石油化工、化 本项目为医院项 空间 工、焦化、电镀、制革等行业企业 目,不属于空间 布局 以及可能造成耕地土壤污染的建设 布局约束管控要 约束 项目。 求的禁止类项 2.静脉产业园周边应设置防护距 目。 符 合 离,保护农田等周边环境质量。 1.禁止含重金属废水进入城市生活 污水处理厂。 郸城 2.禁止向耕地及农田沟渠中排放有 ZH41 一般 县一 毒有害工业、生活废水和未经处理 16253 管控 般管 的养殖小区畜禽粪便;禁止占用耕 0001 单元 控单 地倾倒、堆放城乡生活垃圾、建筑 元 污染 垃圾、医疗垃圾、工业废料及废渣 物排 等废弃物。 放管 3.禁止填埋场渗滤液直排或超标排 控 放。 4.静脉产业园、垃圾填埋场、垃圾 焚烧发电厂等从严从新执行环保排 放标准,高水平建设废水、废气、 废渣处理设施,确保垃圾焚烧烟道 气、粉尘、垃圾渗滤液等污染物稳 定达标排放。 235 项目医院不产生 含铬废水、含汞 废水、含氰废物 等重金属废水。 医院废水处理达 标后排入郸城县 第三污水处理厂 进一步处理,医 院生活垃圾、医 疗废物、栅渣污 泥、废紫外线含 汞灯管等均得到 合理处置。 符 合 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 1. 对涉重行业企业加强管理,建立 土壤和地下水污染隐患排查治理制 环境 风险 防控 度、风险防控体系和长效监管机 本项目不属于涉 制。2.高关注地块划分污染风险等 重企业,医院建 级,纳入优先管控名录。 设完成后应按该 3.危险化学品生产、储存、使用等 要求建立健全环 企业在拆除生产设施设备、污染治 境风险防控体 符 理设施时,要事先制定残留污染物 系,制定环境风 合 清理和安全处置方案。 险应急预案,成立 4.静脉产业园、垃圾填埋场、垃圾 应急组织机构, 焚烧厂等园区及相关企业建立健全 具备事故应急能 环境风险防控体系,制定环境风险 力。 应急预案,成立应急组织机构,具备 事故应急能力。 资源 利用 / 效率 / / 要求 综上,项目符合“三线一单”及本项目所在管控单元生态环境准入清单要求。 8.1.3.4《周口市生态环境保护委员会办公室关于印发<周口市深入打好秋冬重污染天气 消除、夏季臭氧污染防治和柴油货车污染治理攻坚战行动方案>的通知》(周环委办 [2023]10 号)符合性分析 项目建设符合《周口市生态环境保护委员会办公室关于印发<周口市深入打 好秋冬重污染天气消除、夏季臭氧污染防治和柴油货车污染治理攻坚战行动方 案>的通知》(周环委办[2023]10 号)相关要求,具体分析如下。 表 8-8 本项目与周环委办[2023]10 号相符性分析 相 相关要求 本项目情况 符 性 统筹大气污染防治与“双碳”目标要求,推动产业结构 和布局优化调整,坚决遏制“两高”项目盲目发展,依 突出工 程减 排。 法依规淘汰落后、低效产能,实施落后产能“动态清 零”;持续压减钢铁、水泥、砖瓦等行业过剩产能,推 动水泥熟料、烧结砖瓦行业常态化错峰生产;推行钢 铁、焦化、烧结一体化布局,推动长流程炼钢转型为 电炉短流程炼钢;推进煤电“以大代小”、“以新换旧” 容量替代建设,有序关停整合 30 万千瓦以上热电联 236 本项目不属于两高 项目。医院不设锅 炉 相 符 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 产机组供热合理半径范围内落后燃煤小热电机组(含 自备电厂)和燃煤锅炉;加快铁路干线建设,大力推 进煤炭、矿石、焦炭、建材(含砂石骨料)等大宗货 物铁路或水路运输,大力发展新能源车船,从源头上 减少大气污染物和碳排放。强化 VOCs、NOX 等多污 染物协同减排,实施工业炉窑清洁能源替代,推进产 业集群节能降碳增效行动和重点行业超低排放改造, 加快实施工业污染排放深度治理,实施低效治理设施 全面提升改造;提升燃油清洁化水平,推进重点行业 企业清洁运输。统筹做好大气污染防治过程中安全防 范工作。 遏制“两高”项目盲目发展。严格落实国家产业规划、 产业政策、“三线一单”、规划环评,以及产能置换、 煤炭消费减量替代、区域污染物削减等要求,严把高 耗能、高排放、低水平项目准入关口。全市大气污染 防治重点区域禁止新增钢铁、电解铝、氧化铝、水泥 熟料、平板玻璃(光伏压延玻璃除外)、煤化工、焦 化、铝用炭素、含烧结工序的耐火材料和砖瓦制品等 行业产能,合理控制煤制油气产能规模,严控新增炼 油产能。强化项目环评及“三同时”管理,国家、省绩 效分级重点行业以及涉及锅炉炉窑的其他行业,新 秋冬季 建、扩建项目污染物排放限值、污染治理措施、无组 重污染 织排放控制水平、运输方式等达到 A 级绩效水平,改 天气消 除攻坚 战行动 方案 建项目污染物排放限值、污染治理措施、无组织排放 控制水平、运输方式等达到 B 级以上绩效水平。新 本项目不属于两高 项目。项目建设符 合国家产业规划、 产业政策、三线一 相 单等要求。项目不 符 属于重点行业,后 期强化项目环评及 “三同时”管理 建、改建、扩建项目大宗货物年货运量 150 万吨及以 上的,原则上要接入铁路专用线或管道;具有铁路专 用线的,大宗货物铁路运输比例应达到 80%以上。 实施工业污染排放深度治理。推进玻璃、煤化工、无 机化工、化肥、有色、铸造、石灰、砖瓦、耐火材 料、炭素、生物质锅炉、生活垃圾焚烧等行业锅炉炉 窑深度治理,全面提升治污设施处理能力和运行管理 水平,加强物料运输、装卸储存及生产过程中的无组 医院不设锅炉 织排放控制,确保稳定达标排放。推进氨排放治理, 相 符 加强电力、钢铁、水泥、焦化等重点行业烟气脱硫脱 硝氨逃逸防控,减少大气氨排放。建立并动态更新重 点行业企业全口径清单,实施精细化管理 柴油货 车污染 治理攻 坚战行 动方案 大力推广新能源汽车。各地城市建成区每年新增或更 新的公交车、环卫车、巡游出租车和接入平台的网约 2025 年底,项目 车辆使用新能源 出租车全部使用新能源汽车。市级党政机关每年新 化,优先采用燃料 相 增、更新公务用车采购新能源汽车比例不低于 50%。 电池汽车。2023 符 2025 年底前,除应急车辆外,全市公交车、巡游出 租车和城市建成区的载货汽车(含渣土运输车、水泥 237 年 7 月 1 日,项 目运输车辆采用国 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 罐车、物流车)、邮政用车、市政环卫车、网约出租 车基本实现新能源化。鼓励物流车、市政环卫车、渣 6b 排放标准的车 辆。2025 年底 土运输车等优先采购使用燃料电池汽车,有序推进中 前,全面淘汰国三 重型货车等纯电动、氢燃料电池示范和商业化运营。 及以下排放标准的 推进传统汽车清洁化。2023 年 7 月 1 日,实施轻型 柴油和燃气货车 车和重型车国 6b 排放标准。严格执行机动车强制报 废标准规定,符合强制报废情形的交报废机动车回收 (含场内作业车 辆) 企业按规定回收拆解。2025 年底前,全面淘汰国三 及以下排放标准的柴油和燃气货车(含场内作业车 辆) 推进非道路移动机械清洁发展。严格实施非道路移动 柴油机械第四阶段排放标准。因地制宜加快推进铁路 货场、物流园区、港口、机场,以及火电、钢铁、煤 炭、焦化、建材、矿山等工矿企业新增或更新的作业 车辆和机械新能源化;鼓励新增或更新的 3 吨以下叉 车基本实现新能源化。鼓励各县依据排放标准制定老 旧非道路移动机械更新淘汰计划,推动淘汰国一及以 下排放标准的工程机械(含按非道路排放标准生产的 非道路用车),具备条件的可更换国四排放标准的发 动机;推进铁路内燃机车排放监管,基本消除铁路内 燃机车冒黑烟现象。各县组织开展国有大宗物料运输 医院配套非道路移 动柴油机械满足第 四阶段排放标准, 3 吨以下叉车优先 采用新能源车,运 相 符 输车辆使用国六或 新能源车辆 企业车机结构调整专项行动,积极推进国有企业内部 运输车辆全部使用国六或新能源车辆,鼓励积极更换 第四阶段排放标准或新能源非道路移动机械 8.1.3.5《周口市生态环境保护委员会办公室关于印发<周口市 2023 年蓝天保卫战实施 方案>的通知》(周环委办[2023]13 号)符合性分析 本项目建设符合《周口市生态环境保护委员会办公室关于印发<周口市 2023 年蓝天保卫战实施方案>的通知》(周环委办[2023]13 号)相关要求,具 体分析如下。 表 8-9 本项目与周环委办[2023]13 号相符性分析 相 相关要求 本项目情况 符 性 加快新能源汽车推广应用。各地城市建成区新 持续加 强交通 运输结 构调整 增或更新的公交车、环卫车辆、巡游出租车和 接入平台的网约出租车全部使用新能源汽车。 加快推进城市建成区的载货汽车(含渣土运输 车、水泥罐车、物流车)、邮政用车、环卫用 车、网约出租车使用新能源汽车替代,鼓励优 先采购使用燃料电池汽车,推进重型载货车 238 医院配套车辆使用国六 排放标准的柴油货车或 相 新能源车,优先使用燃 符 料电池汽车 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 辆、工程车辆等纯电动、氢燃料电池示范和商 业化运营 加强扬尘防治精细化管理。开展扬尘治理提升 行动,严格落实扬尘治理“两个标准”要求, 做好建筑工地、线性工程、城乡结合部等关键 部位和重点环节综合治理,加大扬尘污染防治 执法监管力度,逐月开展降尘量监测,实施公 开排名通报,各县市平均降尘量不得高于 7 吨/ 月·平方公里。持续开展城市清洁行动,强化 道路扬尘综合整治,重点提升省道、县乡道 本项目施工扬尘按照最 相 路、城乡结合部和背街小巷等各类道路清扫保 新环保要求执行。 符 项目不属于重点行业, 相 医院不设锅炉 符 洁效果,2023 年底前实现建成区道路清扫覆盖 率达到 90%以上,道路机械化清扫率达到 80% 以上,道路清扫保洁能力显著增强。加强餐饮 油烟日常监督,强化市、县监控平台联网运 行,实现对大型餐饮服务单位油烟排放情况实 时监控;餐饮油烟净化设施月抽查率不低于 20% 推进重点行业超低排放改造。高质量推进钢 铁、水泥行业超低排放改造,2023 年底前全市 推进工 钢铁、水泥企业大气污染物有组织排放、无组 业企业 织排放达到超低排放要求。制定焦化行业超低 综合治 排放改造实施方案,有序推进焦化行业大气污 理 染物有组织排放、无组织排放、运输过程全工 序全流程超低排放改造。强化帮扶指导,协调 解决企业改造过程中的困难和问题,提升企业 改造积极性和运行管理水平。 开展锅炉综合治理“回头看”。2023 年底前, 全面淘汰 35 蒸吨/小时及以下的燃煤锅炉(含 茶水炉、经营性炉灶、储粮烘干设备等燃煤设 施);鼓励淘汰 4 蒸吨/小时以下生物质锅炉, 保留及现有生物质锅炉应采用专用炉具,禁止 掺烧煤炭、垃圾、工业固体废物等其他物料; 推进燃气锅炉低氮燃烧改造,取消烟气再循环 系统开关阀,确有必要保留的,通过设置电动 阀、气动阀或铅封等方式加强监管。加强燃煤 锅炉、生物质锅炉除尘、脱硫、脱硝设施运行 管理,强化全过程排放控制和监管力度,对于 污染物无法稳定达标排放的,依法依规实施整 治。将新建燃煤锅炉、10 蒸吨/小时及以上燃气 锅炉、4 蒸吨/小时及以上生物质锅炉实施自动 监控载入排污许可证;持续推动已建成燃煤锅 239 医院不设锅炉 相 符 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 炉、10 蒸吨/小时及以上燃气锅炉、4 蒸吨/小 时及以上生物质锅炉实施自动监控,督促排污 单位安装自动监控设施、与生态环境部门联 网,并载入排污许可证 8.1.3.6《周口市生态环境保护委员会办公室关于印发<周口市 2023 年碧水保卫战实施 方案>的通知》(周环委办[2023]11 号)符合性分析 本项目建设符合《周口市生态环境保护委员会办公室关于印发<周口市 2023 年碧水保卫战实施方案>的通知》(周环委办[2023]11 号)相关要求,具 体分析如下。 表 8-10 本项目与周环委办[2023]11 号相符性分析 周环委办[2023]11 号相关要求 本项目情况 相符性 24.推动企业绿色转型发展。严格落实环境准 入,落实“三线一单”生态环境分区管控体系,构 (七) 建以“三线一单”为空间管控基础、环境影响评价 统筹做 为环境准入把关、排污许可为企业运行守法依 好其他 据的生态环境管理框架。在造纸、焦化、氮 水生态 肥、农副食品加工、皮革、印染、有色、原料 环境保 药制造、电镀等重点水污染物排放行业,深入 护工作 推进清洁生产审核,推动清洁生产改造,减少 项目符合三线一 单要求,后期应 相符 申报排污许可。 单位产品耗水量和单位产品排污量,促进企业 废水厂内回用 8.1.3.7《周口生态环境保护委员会办公室关于印发<周口市 2023 年净土保卫战实施方 案>的通知》(周环委办[2023]12 号)符合性分析 项目建设符合《周口生态环境保护委员会办公室关于印发<周口市 2023 年 净土保卫战实施方案>的通知》(周环委办[2023]12 号)相关要求,具体分析如 下。 表 8-11 本项目与周环委办[2023]12 号相符性分析 相 周环委办[2023]12 号相关要求 本项目情况 符 性 (一) 4.全面加强固体废物监管。持续开展危险废 物排查整治,全面提升危险废物环境监 医院设置25m2危险废物暂存 管、利用处置和环境风险防范“三个能力”, 间,30m2污泥脱水间、50m2医 壤污染 推动危险废物监管和利用处置能力改革工 疗废物暂存间,危险废物和医 风险管 作。加快健全医疗废物收集转运体系,支 疗废物定期交有资质单位安全 控 持现有医疗废物集中处置设施提标改造。 处置 加强土 动态更新涉危险废物企业“四个清单”,有序 240 相 符 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 推进固废监管信息化建设,强化危险废物 源头管控和收集转运等过程监管。持续开 展小微企业危险废物收集和废铅酸蓄电池 收集转运试点工作。 7.加强废弃危险化学品等危险废物环境管 理,完善危险废物申报登记制度,落实涉 废弃危险化学品企业主体责任,强化废弃 医院加强危险废物环境管理, 危险化学品等危险废物全过程管理。推动 完善危险废物申报登记制度, 涉重金属企业绿色发展,动态更新全口径 强化危险废物全过程管理 相 符 涉重金属重点行业企业清单,推动实施一 批重金属减排工程。 8.1.3.8 郸城县饮用水源保护区规划符合性分析 (1)县级集中式饮用水水源保护 根据《河南省人民政府办公厅关于印发河南省县级集中式饮用水水源保护 区划的通知》豫政办〔2013〕107 号及《郸城县县级集中式饮用水水源保护范 围调整技术报告》,郸城县县城集中式饮用水源地及保护范围如下: ①郸城县一水厂地下水井群(共 13 眼井) 一级保护区:9 号取水井外围 30 米至水厂厂区;1~3 号、10~11 号、13 号取水井外围 30 米的区域;4 号取水井外围 30 米东至文化路西侧红线、南至洺 河南路北侧红线、北至洺河南岸的矩形区域;5 号取水井外围 30 米南至洺河南 路北侧红线、北至洺河南岸的矩形区域;6 号取水井外围 30 米东至迎宾大道西 侧红线的矩形区域;7 号取水井外围 30 米南至交通路北侧红线、西至府东路东 侧红线的矩形区域;8 号取水井外围 30 米西至府东路东侧红线的矩形区域;12 号取水井外围 30 米西至财鑫大道东侧红线的矩形区域。 ②郸城县二水厂地下水井群(共 6 眼井) 一级保护区:1 号取水井外围 30 米至水厂厂区,2~4 号取水井外围 30 米 西至迎宾大道东侧红线的矩形区域;5 号取水井外围 30 米南至科技大道北侧红 线的矩形区域;6 号取水井外围 30 米的区域。 241 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 ★本项目符合性分析:本项目厂址距离郸城县一水厂保护区边界约 1.64km, 距离二水厂保护区边界约 1.396km,均不在郸城县县城集中式饮用水源保护区 范围内。位置关系见附图 15。 (2)乡镇集中式饮用水水源保护区 根据河南省人民政府《关于印发河南省乡镇集中式饮用水水源保护区划的 通知》(豫政办[2016]23 号)、河南省人民政府《关于划定调整取消部分集中 式饮用水水源保护区的通知》(豫政文〔2020〕99 号)和《郸城县乡镇集中式 饮用水水源保护区调整技术报告》,距离本工程最近的郸城县乡镇集中式饮用 水水源保护区为郸城县巴集乡地下水井群(共 6 眼井),一级保护区范围为水厂 厂区及外围东 25 米、北 14 米的区域(1 号取水井),2~6 号取水井外围 30 米 的范围。 根据调查,本工程厂址距离巴集乡饮用水水源保护区边界约 5.132km,不在 巴集乡饮用水水源保护区范围。位置关系见附图 16。 8.2厂址可行性分析 本项目选址位于郸城县科技大道北、公园西路西侧地块。 8.2.1 用地规划符合性分析 根据 2022 年 6 月 5 日郸城县县政府常务会议纪要[2022]40 号,会议同意 划拨郸城县科技大道北、公园西路西侧地块用于实施郸城县人民医院西南院区 新建项目。郸城县自然资源局已于 2022 年 6 月 16 日核发本项目的建设项目用 地预审与选址意见书,编号为用字第 411625202200024。根据附图 13 项目地块 控制性详细规划,项目用地已调整为医疗卫生用地。项目建设符合郸城县用地 规划和城市总体规划。 8.2.3 满足传染病医院设计规范要求 根据前述分析,项目东侧紧邻公园西路,交通方便,项目周边主要为农田 和村庄,环境相对安静,且周边区域无污染源,不属于人口密集区域;本项目 的用地规整,地质构造稳定,地势较高不受洪水威胁;项目所在地周边无密集 242 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 人群;项目选址有比较完善的市政供水、排水、电力等公用系统;周边无易燃 易爆产品生产、储存区域及存在卫生污染风险的生产加工区;不临近幼儿园、 学校等人员密集的公共设施或场所(距离西侧学校巴集五七高中 870m,距离 较远);厂界距离北侧最近村庄 178m,医院医疗建筑物距离东侧郸城县气象 局构筑物 144m,满足 20m 绿化隔离卫生间距的要求。 项目位于郸城县县城的西侧,郸城县地形西高东低,项目所处区域地势较 高,地质条件稳定,不会收到洪水威胁。 项目选址能够满足《传染病医院建筑设计规范》(GB50849-2014)、《传 染病医院建设标准》(建标 173-2016)的相关要求。 8.2.2 外环境对本项目的影响 根据现场调查,本项目周边主要为道路和村庄,项目所在地大气环境质量 较好,就诊环境好;医院附近没有较大的工业废气和噪声污染源,环境相对比 较安静,适合患者治疗和休养;无环境敏感企业。外环境对本项目的影响源主 要为项目东侧公园西路,本项目与公园西路之间均隔有近 30 米绿化带,对公园 西路交通噪声起到了一定的隔声作用,经现场实测本项目东厂界噪声值可以满 足《声环境质量标准》(GB3096-2008)4a 类标准,南、西、北厂界能满足 1 类标准要求评价认为公园西路对就诊及住院患者的就医影响不大。 8.2.3 环境功能区符合性分析 本项目所在区域的环境空气功能为《环境空气质量标准》(GB3095-2012) 标准中的二级标准,经预测,项目建成后产生的硫化氢、氨最大落地浓度满足 《环境影响评价技术导则大气环境》(HJ2.2-2018)附录 D 限值要求对周围环 境敏感点影响较小,运营期不会改变所在区域环境空气功能级别。 本项目所在区域水环境功能为《地表水环境质量标准》(GB3838-2002) 中的 V 类标准,项目建成后经院内污水处理站处理后通过污水管网进入郸城县 第三污水处理厂进一步处理,运营期对周围地表水环境影响很小,不会改变所 在区域水环境功能级别。 243 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 本项目所在区域声环境功能为《声环境质量标准》(GB3096-2008)中 1 类区,经预测,项目运行后四周厂界噪声贡献值均满足《工业企业厂界环境噪 声排放标准》(GB12348-2008)1 类标准(昼间 55dB(A)、夜间 45dB(A)),敏 感点贡献值满足《声环境质量标准》(GB3096-2008)1 类标准,运营期不会改 变所在区域声环境功能。 8.2.4 选址可行性分析结论 综上,项目用地已调整为医疗卫生用地。项目建设符合郸城县用地规划和 城市总体规划。项目建设符合郸城县发展配套医疗服务需要。项目选址能够满 足《传染病医院建筑设计规范》(GB50849-2014)、《传染病医院建设标准》 (建标 173-2016)的相关要求。医院选址交通便利,人们就医便利。工程完成 后,在认真落实评价所提污染防治措施基础上可以实现污染物的达标排放。经 环境影响预测与分析可知,工程建设对周围环境影响很小,不会改变区域环境 功能级别。项目建设具有良好的社会效益和经济效益,从环保角度分析,工程 选址合理。 8.3医院平面布置合理性分析 8.3.1 平面布置原则 医院平面布置应根据厂址现有的地势、地形及生产工艺流程等进行分区设 计,并重点考虑以下因素: ①符合国家防火、卫生、安全规定及有关设计规范; ②充分工艺流程顺畅,物流简洁合理,运输短捷; ③充分利用厂区土地,力求布置紧凑,节约用地; ④考虑主导风向,合理布置生产装置,减少车间直接的相互影响; ⑤满足有关环保要求。 8.3.2 项目平面布置方案 本项目总投资 63480 万元,项目设置床位 800 张,总占地 65550m2 ,总建 筑面积 107656m2 ,主要建设 4 栋 4F 病房楼(建筑面积 26107m2 ,疫情时作为 244 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 隔离病房使用)、1 栋 5F 宿舍楼(建筑面积 4811m2 ,疫情时作为医护人员宿 舍)、1 栋 4-10F 门诊医技传染病综合楼(建筑面积 24810m2),1 栋 5F 呼吸道 病房楼(建筑面积 7447m2),1 栋 4F 后勤办公综合楼(建筑面积 8840m2)、1 栋 2F 发热门诊(建筑面积 2178m2)。设置机动车车位 1140 个。同时配套道路、 绿化、变配电、给排水、污水处理系统等附属设施。 项目门诊医技综合楼位于医院的东北角,方便患者入院就医和治疗;发热 门诊位于门诊楼的南侧,设置单独大门方便发热门诊患者就医,避免交叉感染。 全院地下污水处理站位于医院的西南角。医院设置 1 栋病房楼和宿舍楼,与院 区其他构筑物相互独立,方便疫情发生时作为隔离点使用。项目各个建筑布局 紧凑,既独立又互相临近,功能分区模式符合地区行业管理习惯。 本项目污水处理站设置于医院西南角地下封闭设置,以便医院废水收集和 处理后排放。项目区常年主导风向为东北风向,污水处理站位于常年主导风向 的下风向,不会对上风向的门诊楼、病房楼产生恶臭影响。本项目污水处理站 位于地下一层,各构筑物封闭,污水处理站恶臭经负压收集除臭系统处理后经 管道收集排放,污水处理站上部地面进行充分绿化。为减少污水处理站恶臭对 周围环境的影响,设计单位拟将处理后的恶臭气体经管道引至附近病房楼楼顶 排放(20m 高),对周边环境影响较小,因此本项目污水处理站设置位置可行。 综上分析,评价认为项目在总平面布置上功能分区明确合理,满足必要的 卫生、环保、安全间隔,医院内部的工作流程简短,从而降低能耗,节省能源。 本工程只要严格执行评价提出的污染物防治措施,工程建设对环境的影响在可 接受的范围内。评价认为项目的总平面布置是合理的。 8.3.3 项目公用工程布置合理性分析 本项目污水处理设备采用地下封闭式设置,拟建于项目西南角位于常年主 导风向的下风向,产生的少量恶臭气体采用“负压抽吸+生物除臭+紫外线消毒后 经管 道 引 至附 近 病 房楼 楼顶 排 放” 处理 后 ,满足 《 恶 臭污 染物 排 放 标 准》 (GB14554-93)表 2 标准要求,不会上风向的门诊楼、病房楼产生影响;危废暂 245 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 存间、医疗废物间位于污水处理站东北角,方便收集暂存院内危险废物、医疗 废物,远离生活垃圾,避免雨淋,且方便医疗废物运输车出入,与医疗区、人 员活动密集区分开。综上所述,本项目公用工程位置布置可行。 8.4总量控制分析 8.4.1 总量控制目的 根据国务院发布的《建设项目环境管理条例》第三条的规定:“建设产生污 染的建设项目,必须遵守污染物排放的国家标准和地方标准;在实施重点污染 物排放总量控制的区域内,还必须符合重点污染物排放总量控制的要求”。总量 控制是原国家环保总局确定的“十二五”期间环境保护的重点,目前已对各省、 自治区下达了污染物指令性总量控制指标。总量控制是一种手段,只有实行总 量控制,才能保证建设项目的实施始终与污染物达标排放及环境质量达标的要 求紧密结合起来,便于环境管理,是社会、经济和环境协调发展,社会的可持 续发展提供基础条件的重要保障措施。 8.4.2 总量控制因子 根据十四五期间国家总量控制指标污染物种类包括 COD、氨氮、NOX、 VOCs。根据项目污染物产排特点及当地环保要求,本项目评价总量控制因子确 定为 COD、氨氮。项目不涉及废气总量控制指标。 8.4.3 本项目总量控制指标 1、废水 本项目建成后项目总排水量为 609.24m3/d,包括 588.99m3/d 医疗废水和 20.25m3/d 清 排 水 。 经 院 内 地 下 污 水 处 理 站 处 理 后 , 污 水 总 排 口 出 水 浓 度 COD57.6mg/L 、 BOD516.6mg/L 、 SS18.9mg/L 、 NH3-N13.8mg/L 、 动 植 物 油 0.4mg/L、粪大肠菌群数 96.8MPN/L、LAS4.8mg/L、肠道致病菌及肠道病毒、 结核杆菌不得检出,满足《医疗机构水污染物排放标准》(GB18466-2005)表 1 传染病、结核病医疗机构水污染物排放浓度、最高允许排放负荷标准要求和 246 周口国家农高区医院(郸城县中心医院新区)建设项目环境影响报告书第八章产业政策相符性及厂址可行性分析 郸城县第三污水处理厂进水水质要求,通过市政污水管网外排至郸城县第三污 水处理厂进一步处理。 郸城县第三污水处理厂出水水质执行《城镇污水处理厂污染物排放标准》 (GB18918—2002)中一级标准 A 标准,同时满足《周口市 2019 年水污染防治攻 坚战实施方案》及中共河南省委、河南省人民政府发布的《加强生态环境保护 打好污染防治攻坚战责任书》(2018-2020)中的《地表水环境质量标准》 (GB3838-2002))IV 类标准,进入洺河。 根据污染物排放量估算,本项目废水总量控制建议指标见表 8-12。 表 8-12 本项目总量控制建议指标单位:t/a 项目类 污染 厂区总排口纳管排放量 排入环境量 别 物 (总排放口浓度计算) (污水处理厂出水水质计算) 废水 COD 12.3745 6.6293 NH3-N 3.0793 0.3315 综上所述,则本项目废水总量指标为:COD6.6293t/a,NH3-N0.3315t/a。 2、废气 运营期产生的废气主要为含菌废气、检验废气、泊车位汽车废气、食堂油 烟、地下污水处理站产生的恶臭、垃圾收集站恶臭、备用柴油发电机燃烧废气。 项目不设锅炉,不排放二氧化硫、氮氧化物。项目不涉及废气总量控制指标。 综 上 所 述 , 本 项 目 污 染 因 子 总 量 控 制 指 标 为 : COD6.6293t/a , NH3N0.3315t/a,NOx0t/a。 根据《建设项目主要污染物排放总量指标审核及管理暂行办法》(环发 〔2014〕197 号)的要求,COD、氨氮、SO2、NOx 排放需总量替代。 本项目需替代总量指标为:COD6.6293t/a,NH3-N0.3315t/a,NOx0t/a。 该项目水污染物 COD、NH3-N 总量来源于郸城县益民污水处理有限责任公 司郸城县污水处理厂升级改造工程项目削减的总量指标。 247 郸城县人民医院西南院区新建项目环境影响报告书 第九章环境管理与监测计划 第九章环境管理与监测计划 9.1环境管理 9.1.1 环境管理的必要性 环境管理是以科学理论为基础,运用经济、法律、技术、行政等手段对经 济、社会发展过程中施加给环境的污染和破坏影响进行调节控制,实现经济、 社会、环境效益的和谐统一。建立科学而合理的环境管理机构,是建设项目顺 利完成环境目标的基本保障,也是项目完成环境保护工作并实现可持续发展的 关键。 9.1.2 环境管理机构的设置 根据国家和河南省的有关环保法规及《建设项目环境保护设计规定》,新 建、扩建项目应设置环境管理机构,来负责、落实、监督企业的环保工作。评 价建议该医院单独设立环保科,设置管理人员 1 人,运行人员 2 人,主要负责 企业废水、废气的日常运行管理工作和整个生产的环境管理工作以及整个厂区 的绿化工作。 9.1.3 环境管理机构的职责 本项目环境管理机构职责见表9-1。 表 9-1 项目 本项目环境管理机构职责一览表 管理职责 监督建设期环保措施的落实; 施工期管理 全面检查施工现场的环境恢复情况,并组织人员及时清理 根据《建设项目环境保护竣工验收暂行办法》要求对配套建设的环境保 竣工验收 护设施进行验收,编制验收报告,公开相关信息,接受社会监督; 管理 需要对建设项目配套建设的环境保护设施进行调试的,建设单位应当确 保调试期间污染物排放符合国家和地方有关污染物排放标准和排污许可 248 郸城县人民医院西南院区新建项目环境影响报告书 第九章环境管理与监测计划 等相关管理规定; 建设项目配套建设的环境保护设施经验收合格后,其主体工程方可投入 生产或者使用;未经验收或者验收不合格的,不得投入生产或者使用 认真贯彻执行国家、省、市制定的环保法规和各项规章制度及具体要 求; 制定切实可行的环境保护管理制度并监督执行,编制环保规划,并按计 划实施、落实环保要求; 制定并负责实施环保设备的运行管理计划、操作规程; 对环保设施的运行情况进行监控,负责环保设施及设备的常规维护,确 运营期管理 保其正常、高效运行,严格控制“三废”的排放; 负责委托有资质单位对本厂污染物排放的日常监测工作,负责环境监测 资料管理; 负责环保排污管理、审定工作,处理全厂的环境污染事故,随时做好应 急准备,对已发生的事故应及时处理并上报有关部门; 促进企业按照 ISO14000 标准建立环境管理体系 9.1.4 环境管理建议 9.1.4.1 项目前期工作阶段环境管理 (1)可行性研究阶段 在此阶段,该医院应做的环境管理工作是负责提供项目的环境影响评价报 告书,并报请环保主管部门审批。 (2)设计阶段 设计部门应将环境影响报告书提出的环保措施列入设计和投资概算中,该 医院应对环保措施的设计方案进行审查,并及时提出修改意见。 (3)招标阶段 该医院应在招标阶段对承包商提出施工期的环境保护实施计划,并向建设 部门环保管理者签定环境管理的承包合同。’ 249 郸城县人民医院西南院区新建项目环境影响报告书 第九章环境管理与监测计划 9.1.4.2 试运营期的环境管理 (1)试运营前的准备 ①人员培训:加强员工的环保知识法规教育及操作规程的培训,使各项环 保设施的操作规范化,保证环保设施的正常运转。 ②制定健全医院环保治理设施的操作规程,使各环保设施在生产过程中处 于良好的运行状态。 ③必要时委托有资质单位对污染物的排放进行监测,并做好监测记录及各 班组交接工作等事项。 (2)试运行过程的环保工作 认真贯彻执行环保局对试生产审批的意见,并作好如下工作: ①做好各项环保设施的调试工作。 ②委托有资质单位进行监视性监测:经过调试后,各环保设施必须按规程 操作,同时进行监视性监测,监视环保处理设施运行情况。 ③建立环保工作制度 a、拟定由院长亲自抓全院的环保工作,各部门设有环境管理领导小组,具 体负责医院环境保护管理工作,各班组中设置环境保护管理小组。 b、组织制定本医院的环保管理制度和环保责任制,主要有以下几个方面: 环境影响评价“三同时”制度、污染源限期治理制度、污染处理设施运行管理制 度、污染事故报告与紧急排险制度、大修期间“三废”排放规定。并拟定医院环 保委员会、环保办、环保领导小组和总工程师办公室以及各科室的环保职责。 保证全院环保工作正常运行,并把每位职工工作实绩列入全公司职工考核内容, 作为奖惩项目。 c、环保设施竣工验收:建设单位应根据《建设项目竣工环境保护验收暂行 办法》(国环规环评【2017】4 号)文件要求自主开展项目竣工环境保护验收 工作,经竣工验收合格后方可正式投入生产。 250 郸城县人民医院西南院区新建项目环境影响报告书 第九章环境管理与监测计划 9.1.4.3 运营期的环境管理 (1)贯彻执行运行期建立的环保工作机构和工作制度以及监视性监测制度, 并不断总结经验提高管理水平。 (2)制定各环保设施操作规程,定期维修制度,使各项环保设施在生产过 程中处于良好的运行状态,如环保设施出现故障,应立即停厂检修,严禁非正 常排放。 (3)对技术工作进行上岗前的环保知识法规教育及操作规程的培训,使各 项环保设施的操作规范化,保证环保设施的正常运转。 (4)加强环境监测工作,委托有资质单位做好本项目的自行监测工作,重 点是各污染源的监测,并注意做好记录,不弄虚作假。监测中如发现异常情况 应及时向有关部门通报,及时采取应急措施,防止事故排放。 (5)建立本医院的环境保护档案。档案包括:a、污染物排放情况;b、污 染物治理设施运行、操作和管理情况;c、自行监测方案执行情况;d、自行监 测记录;e、限期治理执行情况;f、事故情况及有关记录;g、与污染有关的生 产工艺、原材料使用方面的资料;h、其他与污染防治有关的情况和资料等。 (6)建立污染事故报告制度。当污染事故发生时,必须在事故发生二十四 小时内,向环保部门作出事故发生的时间、地点、类型和排放污染物的数量、 经济损失等情况的初步报告,事故查清后,向环保部门局面报告事故的原因, 采取的措施,处理结果,并附有关证明。若发生污染事故,则有责任排除危害, 同时对直接受到损害的单位或个人赔偿损失。 9.2环境监测 9.2.1 环境监测的目的 环境监测计划是环境管理的重要组成部分。其目的是为了准确、及时、全 面地 掌握建设项目污染动态,了解项目建设对所在的环境质量变化程度、影响 范围及运营期的环境质量动态,及时向主管部门反馈信息,为项目的环境管理 提供科学依据。 251 郸城县人民医院西南院区新建项目环境影响报告书 第九章环境管理与监测计划 9.2.2 环境监测机构的设置 本项目运营期污染物排放监测委托有资质单位进行,本项目运营期自行监 测按照《排污单位自行监测技术指南 证申请与核发技术规范 总则》(HJ819-2017)、《排污许可 医疗机构》(HJ1105-2020)有关规定进行。本项目 完成后,厂内设置环境监测机构,设置人员 1 名,归属环保科领导,负责根据 《排污单位自行监测技术指南 总则》(HJ819-2017)制定自行监测方案, 并与有资质单位联系,严格落实自行监测,对工程中的主要污染源进行定期监 测,并将监测数据记录在案,发现问题及时上报有关部门。 9.2.3 环境监测机构的职责 根据国家颁布的环境质量标准和污染物排放标准及环境保护监测工作规 定,制定本企业的监测计划和工作方案。 (1)定期对各类污染防治设施进行监测评价,随时掌握其正常及非正常运 行状况。监测结果异常时查明原因,及时上报。 (2)分析污染物排放规律,整理监测数据,并建立企业环保档案。 (3)参加污染事故调查工作,并协助有关方面进行处理。 (4)参加医院环境质量评价,接受地方环保部门的指导和监督。 9.2.4 环境监测计划 根据《排污许可证申请与核发技术规范 医疗机构》(HJ1105—2020)、 《排污许可自行监测技术指南总则》(HJ819-2017)中规定,本项目运营期对 生产过程中生的废气、废水、噪声进行监测,监测内容、监测因子和监测频率 见表 9-2。监测分析方法按照国家有关技术标准和规范执行。 表 9-2 类别 废气 环境监测计划一览表 监测因子 监测点位 废气量,臭气浓度、 污水处理站产生 H2S、NH3 排放速 排气筒出口 的恶臭气体排气筒 率、排放浓度 臭气浓度、H2S、 NH3、甲烷(污水站 污水处理站 污水处理站周界 内最高体积百分 周界 数)、氯气 252 监测频率 依据文件 1 次/季度 HJ1105 —2020 郸城县人民医院西南院区新建项目环境影响报告书 食堂油烟排气筒 废水 噪声 固废 第九章环境管理与监测计划 高效静电式 废气量,油烟、非甲 油烟净化器 烷总烃排放浓度、油 处理系统进 烟处理效率 口、出口 1 次/年 HJ 8192017 HJ11052020、地 自动在线监 流量、pH、COD、氨氮 方环保要 测 求及企业 实际情况 HJ1105— 粪大肠菌群 1 次/月 污水处理站 2020 总排口 HJ1105— SS 1 次/周 2020 结核杆菌、BOD5、阴离子表面活性剂、动 HJ1105— 1 次/季度 植物油、石油类、挥发酚、总氰化物 2020 肠道致病菌(沙门氏菌)、色度、总余氯 1 次/季度 HJ1105肠道致病菌(志贺氏菌)、肠道病毒 1 次/半年 2020、地 方环保要 接触池出 总余氯 1 次/12 小时 求及企业 口 实际情况 每季一次, 四周厂界外 每次两天, HJ 819LAeq 1m 处 昼夜 2017 各一次 粪大肠菌群数、 肠道致病菌、 肠道 GB18466污泥消毒池 每次清掏前 病毒、 结核杆菌、 蛔虫死亡率 2005 9.3排污口标志和管理 9.3.1 排污口标志 (1)污水排放口、废气排放口、噪声排放源图形标志。 污水排放口、废气排放口和噪声排放源图形符号分为提示图形符号和警告 图形符号两种,图形符号设置按(GB15562.1-1995)执行,见下表。 (2)固体废物贮存(处置)场图形标志 固体废物贮存(处置)场图形符号分为提示图形符号和警告图形符号两种, 图形符号设置按(GB 15562.2-1995)修改单执行,见表 9-3。 表 9-3 序号 提示图形符号 背景颜色:绿色 图形颜色:白色 排放口规范化标志 警告图形符号 背景颜色:黄色图形颜 色:黑色 253 名称 功能 郸城县人民医院西南院区新建项目环境影响报告书 第九章环境管理与监测计划 1 废水排放口 表示废水向环 境排放 2 废气排放口 表示废气向大 气排放 3 噪声源 表示噪声向外 环境排放 一般固体废物 表示一般固体 储 废物存储场所 存 4 5 / 危险废物储存 表示危险废物 暂存场所 (3)排污口立标 污染物排放口的环保图形标志牌应设置在靠近采样点,且醒目处,标志牌 设置高度为其上边缘距离地面 2m,可根据情况设置立式或平面固定式标志牌。 9.3.2 排污管理 9.3.2.1 管理原则 排污口是企业污染物进入环境,污染环境的通道,强化排污口的管理是实 施污染物总量控制的基础工作之一,也是区域环境管理逐步实现污染物排放科 学化、定量化的重要手段。具体管理原则如下: 254 郸城县人民医院西南院区新建项目环境影响报告书 第九章环境管理与监测计划 (1)向环境排放污染物的排放口必须规范化; (2)列入总量控制的污染物(COD、氨氮)排放源列为管理的重点; (3)如实向环保管理部门申报排污口数量、位置及所排放的主要污染物种 类、数量、浓度、排放去向等情况; (4)废气排气装置应设置便于采样、监测的采样孔和采样平台,设置应符 合《污染源监测技术规范》; (5)工程固废堆存时,应设置专用堆放场地,并采取防扬散、防流失、对 有毒有害固废采取防渗漏的措施。 9.3.2.2 排放源建档 (1)本项目应使用国家环保总局统一印制的《中华人民共和国规范化排污 口标志登记证》,并按要求填写有关内容; (2)根据排污口管理内容要求,项目建成投产后,应将主要污染物种类、 数量、浓度、排放去向、立标情况及设施运行情况记录于档案。 9.4 污染物排放清单 本项目污染物排放清单见下表。 按照《企业环境信息依法披露管理办法》 (2021 年 11 月 11 日生态环境部令第 24 号)等规定:企业应建立健全本单位环 境信息公开制度,及时、如实的公开其环境信息;公开的信息应包括: (1)单位名称、组织机构代码、法定代表人、地址、联系方式以及生产经 营和管理服务的主要内容、规模等基础信息; (2)主要污染物名称、排放方式、排放口数量和分布情况、排放浓度、总 量、超标情况等排污信息。 该项目应当通过其网站、建设单位环境信息公开平台或者当地报刊等便于 公众知晓的方式公开环境信息,同时可以采取以下一种或者几种方式予以公开: (1)公告或者公开发行的信息专刊; (2)广播、电视等新闻媒体; (3)信息公开服务、监督热线电话; (4)本单位的资料索取点、信息公开栏、信息亭、电子屏幕、电子触摸屏 等场所或者设施。 255 郸城县人民医院西南院区新建项目环境影响报告书 第九章环境管理与监测计划 表 9-4 污染源 废 水 废 气 医疗废水(化验室废 水、门诊废水、住院病 房废水、医务人员废 水、空调冷凝水、蒸汽 消毒废水、病区食堂废 水)、非病区废水(后 勤办公人员废水、宿舍 楼、普通食堂、空调冷 凝水) 环境保护措施及主要效 率 预处理(油水分离设施、 中和池、化粪池、臭氧 预消毒)+自建污水处理站 (格栅+调节池+水解酸化 +接触氧化+MBR膜池+ 次氯酸钠消毒+脱氯池) 后勤办公综合楼食堂油 烟 经 1 套高效静电式油烟净 化器处理后楼顶排放 门诊医技综合楼食堂油 烟 经 1 套高效静电式油烟净 化器处理后楼顶排放 地下污水处理站产生的 恶臭 各构筑物为地下式,池 顶加盖,恶臭气体经风 机抽风后送入生物(滤 池)除臭+紫外线消毒经 本项目污染物排放总量汇总单 污染物 排放浓度 名称 pH COD(mg/L) BOD5(mg/L) SS(mg/L) NH3-N(mg/L) 动植物油(mg/L) 粪大肠菌群(MPN/L) LAS(mg/L) 肠道致病菌(MPN/L) 肠道病毒(MPN/L) 结核杆菌(MPN/L) 全盐类(mg/L) 油烟(mg/L) 非甲烷总烃总烃 (mg/L) 油烟(mg/L) 非甲烷总烃总烃 (mg/L) H2S(mg/m3) NH3(mg/m3) 臭气浓度(无 量纲) 256 6~9 56 17 18.6 13.9 3.9 87.1 4.8 不得检出 不得检出 不得检出 排放量/处 置量t/a 111 0.375 / 12.3745 3.7529 4.1058 3.0793 0.8554 19.2458 1.0692 / / / 24.528 0.00329 0.377 0.00330 0.521 0.0274 0.524 0.0275 0.058 1.503 0.0010 0.0263 750 / 排放时段 排污 口信 息 年排放365天, 每天24小时连 续排放 污水 处理 站 出口 年排放 365 天, 每天间歇排放 经专 用烟 道 楼顶 排放 河南省地方标准 《餐饮业油烟污 染物排放标准》 表 1 大型 年排放365天, 每 天24小时连续 排放 20m 高排 气筒 恶臭污染物排放 标准》表2、 《医疗机构水污 染物排放标准》 执行排放标准 《医疗机构水污 染物排放标准》 (GB18466-2005) 表1标准 郸城县人民医院西南院区新建项目环境影响报告书 生活垃圾收集桶,环卫 清运 专用餐厨垃圾桶收集收 集,交由有资质单位进 行处置 更换后随生活垃圾一同 交环卫部门清运处理 固 体 废 物 医疗废物暂存间暂存, 每日交由有资质单位进 行处置 污水站污泥险废物进行 管理消毒脱水后装入密 封袋内,直接交由有资 质单位进行处置,原则 上不进行贮存,暂时无 法清运的装袋后暂存于 危废暂存间,定期交有 资质单位处置 危废暂存间暂存,定期 交有资质单位处置 第九章环境管理与监测计划 管道引至附近病房楼楼 顶排放(20m高,周边最 近病房楼设计高度 18.65m),臭气污染物 去除效率70% 医务后勤人员办公及宿 舍产生的普通生活垃圾 / / 292 餐厨垃圾 / / 511 / / 0.1 废反渗透膜(纯水制 备) 门诊、病房楼病人产生 的生活垃圾(属于医疗 废物) 医疗废物 污水处理站产生的污泥 (GB184662005)污水处理 站周边大气污染 物最高允许浓度 / / 321.2 / / / / 148.92 132.5821 污水处理站产生的栅渣 / / 3.8492 废紫外线含汞灯管 / / 0.16 257 合理处置,不外 排 年排放365天, 每天间歇排放 在污 染治 理 设施 处设 置标 识牌 《危险废物贮存 污染控制标准》 (GB185972023); 污泥执行《医疗 机构水污染物排 放标准》 (GB184662005)表4 医疗机构污泥控 制标准,按照危 险废物进行管理 郸城县人民医院西南院区新建项目环境影响报告书 9.5 第九章环境管理与监测计划 “三同时”竣工验收内容 按照国家的有关要求,项目建成后须对其环保设施进行“三同时”验收。根 据本项目的情况,“三同时”验收内容见表 9-5。 表 9-5 施工期“三同时”验收内容一览表 类别 污染源 验收内容 执行标准 《污水综合排放标准》 临时隔油池10m3、化粪池10m3处理后排 (GB8978-1996)表4中 生活污水 入周边市政污水管网 废水 水处理厂进水水质要求 临时沉淀池20m3处理后回用到车辆冲 施工废水 落实“八个百分百” 机械设备运行 废气及运输车 加强设备及车辆维护,施工场地较开 阔,扩散条件良好 辆废气 装修废气 零排放 洗、施工场地洒水降尘 施工扬尘 废气 三级标准及郸城县第三污 减少对周边环境的影响 选用符合国家规定质量要求的环保型油 漆、涂料、胶粘剂及装饰材料 设置围挡,选用低噪声设备及施工工 艺,合理布局,合理安排施工时间,严 满足GB12523-2011《建 噪声 施工噪声 禁夜间施工,车辆进入敏感区域限速禁 筑施工场界环境噪声排放 鸣,定期对设备及车辆维护、养护,加 标准》 强施工队伍管理禁止高声喧哗 生活垃圾 固废 建筑垃圾 垃圾桶进行收集,由环卫部门统一清运 分类收集,可利用部分回收利用,不能 利用部分运至指定建筑垃圾填埋场 弃方 妥善安置,零排放 运至当地政府指定地点 加强临时堆放场的管理,制定土方表面 生态 水土流失 压实、定期喷水、覆盖、设置截排水沟 等措施;不需要的泥土,建筑材料弃渣 减少水土流失 应及时运走,不宜长时间堆积 表 9-6 类别 废水 污染源 运营期环保“三同时”验收内容一览表 验收内容 执行标准 医院地下总污水处理站710m3/d 《医疗机构水污染物排放标准》 医院综合废 (地下)、病区食堂油水分离 (GB18466-2005)表 1 传染病、结 水 器处理能力180m3/d、病区中和 核病医疗机构水污染物排放浓度、 池容积7m3、病区专用化粪池+ 最高允许排放负荷标准要求及郸城 258 郸城县人民医院西南院区新建项目环境影响报告书 第九章环境管理与监测计划 臭氧预消毒池430m3/d(容积1个 县第三污水处理厂进水 450m3、1个100m3、1个45m3、1 水质要求 个500m3)、非病区食堂油水分 离器处理能力22m3/d、 非病区普通化粪池 35m3/d(容 积 1 个 30m3、1 个 60m3)、车 辆洗消废水消毒池容积 10m3, 污水处理站处理工艺:“预消毒 +格栅+调节池+水解酸化+接触 氧化+MBR 膜池+次氯酸钠消毒 +脱氯池”,自动监测设施 病区含菌废气采用紫外线杀毒 后经专用排风烟道引至楼顶排 放;手术室、负压病房采用全 含菌废气 新风直流式空调系统,送风应 含菌气体经消毒后在室外经扩散和 经过初效、中效、高效过滤器 稀释后对最近居民区基本无影响 三级处理,排风经过高效过滤 器过滤处理后经过专用排风烟 道引至楼顶排放 经安全柜配套高效空气过滤器 处理后去除致病细菌、生物气 溶胶及其他污染物有害气体 检验废气 后,再引至楼顶排放,同时医 周围环境影响较小 院做好检验室内的消毒卫生工 作,确保检验废气处理后不会 废气 对周围环境造成明显影响 后勤办公综 经1套高效静电式油烟净化器处 合楼食堂油 理后经烟道引至后勤办公综合 烟 楼楼顶排放 门诊医技综 经1套高效静电式油烟净化器处 合楼食堂油 理后经烟道引至门诊医技综合 烟 楼楼顶排放 机动车泊 道路两侧加强绿化,地下车库 车位汽车 设置抽排风系统,及时疏导进 尾气 出泊车位车辆 污水处理站 恶臭气体 河南省地方标准《餐饮业油烟污染 物排放标准》(DB41/1604-2018) 表 1“大型”标准 周围环境影响较小 1 套负压抽吸+生物除臭+紫外线 消毒后经管道引至附近病房楼 《恶臭污染物排放标准》 楼顶排放 (GB14554-93)表 2 标准 危废间废气 经管道引至污水站恶臭措施处 259 郸城县人民医院西南院区新建项目环境影响报告书 第九章环境管理与监测计划 理排放 仅收集,不处理不压缩。垃圾 生活垃圾收 袋装化,减少垃圾暴露时间, 集站恶臭 及时清运,日产日清,使用除 臭剂 备用柴油发 电机燃烧废 气 经自带的净化装罝处理后,通 过专用烟道引至楼顶排放 周围环境影响较小 《工业企业厂界环境噪声排放标 噪声 高噪声设备 隔声、减振、消声等降噪措施 准》(GB12348-2008)、《声环境 质量标准》(GB3096-2008)1 类 医务后勤人 员办公及宿 舍产生的普 垃圾桶、垃圾箱若干,95m2 垃 通生活垃 圾收集站 圾、废反渗 《一般工业固体废物贮存和填埋污 染控制标准》(GB18599-2020) 透膜 固体 废物 餐厨垃圾 专用餐厨垃圾收集桶若干 门诊、病房 楼病人产生 的生活垃圾 50m2 医疗废物暂存间 及医疗废物 《危险废物贮存污染控制标准》 污水站栅渣 (GB18597—2023) 污泥、废紫 污泥脱水间(30m2)、危险废 外线含汞灯 物暂存间(25m2) 管 260 郸城县人民医院西南院区新建项目环境影响报告书 第十章环境影响评价结论 第十章 环境影响评价结论 10.1评价结论 10.1.1 项目建设符合国家相关产业政策的要求 经查阅产业政策,该项目属于《产业结构调整指导目录(2019 年本)》本 项目属于鼓励类中第三十七条“卫生、健康”中第 6 条“传染病、儿童、精神 卫生专科医院和康复,因此,本项目建设符合国家产业政策。本项目属于《国 民经济行业分类》(GB/T4754-2017)中“Q8415 专科医院”,符合国家产业政策。 根据《郸城县发展和改革委员会关于郸城县人民医院西南院区新建项目可行性 研究报告的批复》(郸发改社会[2022]202 号),郸城县发展和改革委员会 已同意郸城县人民医院西南院区新建项目的建设。 2022 年 6 月 5 日郸城县县政府常务会议纪要[2022]40 号,会议同意划拨 郸城县科技大道北、公园西路西侧 97 亩土地用于实施郸城县人民医院西南院区 新建项目。郸城县自然资源局已于 2022 年 6 月 16 日核发本项目的建设项目用 地预审与选址意见书,编号为用字第 411625202200024。根据附图 13 项目地块 控制性详细规划,项目用地已调整为医疗卫生用地。项目建设符合郸城县用地 规划和城市总体规划。 10.1.2 区域环境质量 10.1.2.1环境空气 评价区域内环境空气 PM10、PM2.5 年均值超标,超标倍数分别为 0.01 倍和 0.17 倍;特征污染物 H2S、NH3 均满足《环境影响评价技术导则大气环境》 (HJ2.2-2018)附录 D 中要求,本项目所在区域属于不达标区。 10.1.2.2地表水 2022 年洺河杨楼闸断面化学需氧量、氨氮、总磷、总氮浓度均存在超标现 象,最大超标倍数分别为 0.24、1.27、0.33、7.11。超标原因主要是由于洺河为 郸城县纳污河流常年接收郸城县生活污水和生产废水所致。 261 郸城县人民医院西南院区新建项目环境影响报告书 第十章环境影响评价结论 10.1.2.3声环境 根据现场监测,本项目厂界及敏感点噪声值均满足《声环境质量标准》 (GB3096-2008)1 类、4a 标准要求,项目区周边声环境较好。 10.1.3 污染物达标排放及环保措施可行 10.1.3.1废气 本项目产生的废气主要为含菌废气、检验废气、泊车位汽车废气、食堂油 烟、地下污水处理站产生的恶臭、垃圾收集站恶臭、备用柴油发电机燃烧废气。 本项目病区含菌废气采用紫外线杀毒后经专用排风烟道引至楼顶排放;手 术室、负压病房采用全新风直流式空调系统,送风应经过初效、中效、高效过 滤器三级处理,排风经过高效过滤器过滤处理后经过专用排风烟道引至楼顶排 放。含菌气体经消毒后在室外经扩散和稀释后对最近居民区基本无影响。 本项目在检验过程中使用少量有机试剂等(如酒精、甲醇、二甲苯等),这 些物质具有一定的挥发性,日常封闭储存,使用时会产生少量的挥发性有机 废 气等。该部分废气的挥发量很少,检验过程均采用全自动分析设备,只需将药 剂和样品放进设备内,即可自动进行化验得出结果,整个过程均由密闭的设备 进行,检验室内设有安全柜,检验废气经安全柜自带的高效空气过滤器处理后 去除致病细菌、生物气溶胶及其他污染物有害气体后,再引至楼顶排放,排气 中的致病细菌及生物气溶胶可被除去,减轻对环境和周围环境的影响,同时医 院做好检验室内的消毒卫生工作,确保检验废气处理后不会对周围环境造成明 显影响。 地下车位周围空旷,汽车尾气易于扩散。地下车库安装抽排风系统,加强 地下车库空气流通,产生的汽车尾气对周围环境影响较小。 项目设置 2 个食堂,后勤办公综合楼内设置 1 个食堂供后勤办公人员就餐, 门诊医技综合楼设置 1 个食堂供医护人员及病患就餐。食堂提供病房送餐服务。 后勤办公综合楼食堂油烟废气、门诊医技综合楼食堂油烟废气经高效静电式油 烟净化器处理后,均能满足河南省地方标准《餐饮业油烟污染物排放标准》 262 郸城县人民医院西南院区新建项目环境影响报告书 第十章环境影响评价结论 (DB41/1604-2018)(油烟 1.0mg/m3 ,非甲烷总烃 10.0mg/m3 ),由专用排烟 通道引至各自楼顶排放。 本项目地下污水处理站恶臭经负压收集+生物除臭+紫外线消毒装置处理后 经管道引至附近病房楼楼顶排放(20m 高),臭气浓度、H2S 和 NH3 排放速率 均满足《恶臭污染物排放标准》(GB14554-93)表 2 要求。经预测,项目建成 后污水站产生的硫化氢、氨最大落地浓度满足《环境影响评价技术导则大气环 境》(HJ2.2-2018)附录 D 限值要求对周围环境影响较小,运营期不会改变所 在区域环境空气功能级别。 生活垃圾收集站不进行垃圾处理、无压缩工艺,垃圾收集点产生的恶臭很 轻微,对环境无明显影响。评价要求采取的措施:垃圾袋装化,可有效防止生 活垃圾收集站)H2S 和 NH3 等恶臭污染物散发,必要时使用除臭剂;尽量减少 垃圾暴露时间,及时清运,日产日清,夏季增加清运次数。 本项目配备有 2 台柴油发电机组,其排放的燃油废气中主要包含 CO、 NOx 等污染物。备用发电机在供电正常时不使用,只有在停电情况下才会使用, 发电时间短,全年使用时间少,废气排放量少,采用轻质柴油作为燃料,污染 物排放量极少,故不再进行定量分析。发电机废气经过自带的净化装罝处理后, 通过专用烟道引至楼顶排放。 10.1.3.2废水 本项目产生的医疗废水采用“预消毒+格栅+调节池+水解酸化+接触氧化 +MBR 膜池+次氯酸钠消毒+脱氯池”工艺进行处理后,总排水口水质浓度为: COD56.0mg/L 、 BOD517.0mg/L 、 SS18.6mg/L 、 NH3-N13.9mg/L 、 动 植 物 油 3.9mg/L、粪大肠菌群数 87.1MPN/L、LAS4.8mg/L、肠道致病菌及肠道病毒、 结核杆菌不得检出,外排废水水质可以满足《医疗机构水污染物排放标准》 (GB18466-2005)表 2 预处理标准,同时满足郸城县第三污水处理厂设计进水 水质要求。 263 郸城县人民医院西南院区新建项目环境影响报告书 第十章环境影响评价结论 从排水路线、水量及水质等方面分析,本项目废水进入郸城县第三污水处 理厂做进一步处理是可行的。本项目废水经院内污水处理站处理后排入郸城县 第三污水处理厂进一步处理,废水处理后达标排放,因此项目废水对项目所在 区域地表水环境影响较小。 10.1.3.3噪声 本项目的高噪声源主要有中央空调风冷热泵机组、污水站水泵、水泵房水 泵及污水站风机、食堂风机、液氧站空压机等运转产生的噪声,经过隔声、减 振、消声等降噪措施处理后,噪声声源值均有较大程度降低,对周围外环境影 响较小。 根据噪声预测结果可知,本项目完成后,在严格落实评价提出的噪声污染 防治措施的前提下,各厂界的噪声贡献值均满足《工业企业厂界环境噪声排放 标准》(GB12348-2008)1 类、4 类标准要求,周围敏感点噪声满足《声环境 质量标准》(GB3096-2008)1 类标准,对周围声环境影响较小。评价建议院方 加强管理,做好厂区噪声的防治工作,加强厂界四周绿化,多种灌木和乔木树 种,进一步减轻噪声对外环境的影响。 10.1.3.3 固体废物 项目运营期固体废物主要为医务后勤人员办公及宿舍产生的普通生活垃圾、 餐厨垃圾、废反渗透膜(纯水制备)、门诊病房楼病人产生的生活垃圾(属于 医疗废物)、医疗废物、污水站栅渣及污泥、废紫外线含汞灯管。 医务后勤人员办公及宿舍产生的普通生活垃圾分类收集后,日产日清,每 天由环卫部门负责清运至市政垃圾中转站,最终运至郸城县生活垃圾焚烧厂发 电厂焚烧。废反渗透膜更换后随生活垃圾一同交环卫部门清运处理。 餐厨垃圾采用专用餐厨垃圾收集桶收集,集中收集后交由有资质的单位进 行运输处 置。 门诊、病房楼病人产生的生活垃圾及医疗废物按照医疗废物进行暂存管理 和处置,定期交由有资质单位进行清运处置。 264 郸城县人民医院西南院区新建项目环境影响报告书 第十章环境影响评价结论 污水站栅渣、污泥消毒脱水后,作为危险废物定期交有资质单位处置。废 紫外线含汞灯管危废间暂存交由有资质单位处置。 10.1.4 环境风险分析 项目涉及的危险物质为液氧、柴油、盐酸、次氯酸钠及化验室用化学试剂, 环境风险潜势为Ⅰ,评价工作等级为简单分析。 评价建议严格落实本评价提出 的风险事故防范措施,并在建成投产同时验收落实有关安全管理措施, 将项目 风险事故发生概率及影响危害程度降到最低。 评价认为, 在认真落实评价提出 的各项风险防范措施及应急预案的基础上, 项目风险发生概率较低, 风险水平 可以接受。 10.1.5 项目建设厂址从环保角度来讲是可行的 本项目选址位于郸城县科技大道北、公园西路西侧地块,用地符合要求, 废水排放路线可行,经现场调查,评价范围内没有自然保护区、风景名胜区、 文物古迹和饮用水源保护区,也没有需要保护的珍惜动植物及野生动物。 本项目完成后,在认真落实评价所提污染防治措施基础上可以实现污染物 的达标排放。经环境影响预测与分析可知,工程建设对周围环境影响很小,不 会改变区域环境功能级别。项目建设具有良好的社会效益和经济效益,评价认 为从环保角度分析,工程所选地址可行。 10.1.6 公众参与 建设单位按照《环境影响评价公众参与办法》的要求,于 2023 年 6 月 8 日 在周口市生态环境局网站进行了一次环境影响评价信息公开,于 2023 年 7 月 24 号至日在周口市生态环境局网站进行了二次征求意见稿公开,同时在报纸大 河健康报上进行两次公示、公告栏公示,程序符合环境影响评价公众参与的要 求,在公众参与期间没有收到公众的反馈信息,公众对本项目的建设没有反对 意见。 10.1.7 总量控制 COD6.6293t/a,NH3-N0.3315t/a,NOx0t/a。 265 郸城县人民医院西南院区新建项目环境影响报告书 第十章环境影响评价结论 10.2对策和建议 (1)在项目的总图布置中,按《医院污水处理技术指南》的要求,设计医 院废水处理设施,在通过论证后,投入施工,建成竣工验收后,方能投入使用。 (2)建议医院建立相应的环保管理监测机构,设专人负责环保管理。对 “三废”污染物的排放情况进行定期、定时监测和管理,及时调整运行状态,保 证“三废”治理设施保持最佳状态。 (3)评价建议,项目周边不得建设污染较重或具有较大环境风险的建设项 目。本项目周边拟建的企业必须充分考虑医院这一敏感目标。 综上所述,项目建设符合国家产业政策,厂址选择可行,总平面布置合理。 项目在认真落实评价提出的各项污染防治措施后,各项污染物均能满足达标排 放的要求;项目对区域环境的影响较小。同时,项目建设能够产生较好的经济 效益和社会效益。因此,从环保角度分析,本项目建设是可行的。 266