PDF文库 - 千万精品文档,你想要的都能搜到,下载即用。

德国nivuflow750多普勒明渠流量计(V-ADCP).pdf

Ponnenult□旧时光12 页 1.408 MB下载文档
德国nivuflow750多普勒明渠流量计(V-ADCP).pdf德国nivuflow750多普勒明渠流量计(V-ADCP).pdf德国nivuflow750多普勒明渠流量计(V-ADCP).pdf德国nivuflow750多普勒明渠流量计(V-ADCP).pdf德国nivuflow750多普勒明渠流量计(V-ADCP).pdf德国nivuflow750多普勒明渠流量计(V-ADCP).pdf
当前文档共12页 2.88
下载后继续阅读

德国nivuflow750多普勒明渠流量计(V-ADCP).pdf

NivuFlow 750 new High accurate flow measurement for slightly polluted and dirty media in part filled and full pipes, channels and more NivuFlow 750 The consequent further development of our proven transmitter family Flow measurement systems by NIVUS stand for innovation, reliability and highest accuracy. NivuFlow 750 is a fixed transmitter for continuous flow measurement, flow control as well as for storage of measurement values recorded in slight to heavily polluted media featuring various consistencies. It is designed for use in open channels, closed and part full pipes with various shapes and dimensions. 2 Flow measurement systems at the highest technical level + Very high measurement accuracy + Suitable even for very difficult + High-resolution graphic daylight applications + Real-time measurement of real flow velocity profiles + Intuitive, modern operating concept for quick and easy initial start-up + Integrated numeric flow models + Measurement in channels, part filled and full pipes as well as flumes + Weatherproof version for outdoor use + Ex approval Zone 1 + MCERTS (in preparation) + Extensive diagnostic functions display for reliable initial start-up and quick maintenance + Compact construction for narrow switching cabinets + Quick wiring thanks to easily accessible connection points + Universal, standardised interfaces for easy integration + Online connection/data transmission and remote maintenance via Internet Typical Applications WWTPs, channel networks, discharge constructions, industrial wastewater networks, measurement places for billing, intakes, drainage lines, return sludge lines, recirculation lines and many more 3 NivuFlow 750 The right sensor for each application The complete flow measurement system consists of the NivuFlow 750 transmitter and the appropriate sensors. For flow velocity measurement starting at flow levels as low as 3 cm up to several meters in pipes, flumes and channels of various shapes and dimensions there is a wide selection of sensors available: flow velocity sensors with and without integrated flow level measurement as well as air-ultrasonic flow level sensors. Your benefits + Absolutely zero point stable and drift-free sensors + Low installation expenses through perfectly matched mounting accessories + Installation under process conditions + Various sensor constructions guarantee the best solution for each application + Digital signal transmission for errorfree connections over long distances + Ex approval Zone 1 Air-ultrasonic sensor for level measurement, installed in flume crown Flow velocity sensors for installation on the channel bottom or channel walls Flow velocity sensors for installation in pipes and in the NIVUS Pipe Profiler 4 Perfect solutions even under diffcult conditions The alternative to EMFs. Installation without removing the EMF. Patented float solution for detection of flow and sedimentation High accurate measurement in part filled pipes You need an individual solution to your measuring problem or you are interested in more application examples? Just talk to us. NivuFlow is available as unit for installation in control cabinet or with a robust field enclosure 5 NivuFlow 750 Nivu Flow 750 - Universal transmitter The intuitive one-hand operation and the bright high-resolution colour display allow quick, easy and cost-efficient commissioning on site. Additional input devices or software are not required. The latest integrated numeric discharge models enable more accurate, more stable and more reliable determination of flow rates even under very difficult measurement conditions. The 3D flow profile is calculated in real time and is reproducibly and verifiably indicated on the transmitter display. Factors influencing the calculation results such as channel shapes, discharge behaviour and wall roughness are considered during flow calculation. In addition to the compact DIN rail version there is a weatherproof field unit available featuring appropriate connection space for outdoor installation Screen display menu Screen display main screen Screen display 3-D flow profile Screen display measuring place 6 Screen display Level sensors www v Technical Information NivuFlow 750 195 Dimensions in mm Power supply Power consumption Enclosure Protection Operating temperature Storage temperature Max. humidity Display Operation Connection Inputs Outputs Controller Data memory Communication 74 88 232,8 Field enclosure 52 135 140 DIN rail enclosure for easy installation in switching cabinet 354,8 ca. 130 85 to 240 V AC, +10 % /-15 %, 47 to 63 Hz or 9-36 V DC typical 14 VA Aluminium, plastic (installation in switching cabinet), plastic (field enclosure) IP 20 (installation in switching cabinet), IP 68 (field enclosure) -20°C to +70°C -30°C to +75°C 80%, non-condensing 240 x 360 pixel, 65536 colours rotary pushbutton, 2 function keys, menus in German, English, French, Swedish and other languages plug with cage clamp terminals up to 7 x 4 - 20 mA, up to 4 x RS 485 for connection of up to 9 flow velocity sensors (via multiplexer) up to 4 x 0/4 – 20 mA, up to 5 x relays (SPDT) 3-step controller, quick close control, adjustable valve position in case of error 1.0 GB internal memory, readout on faceplate via USB stick Modbus, HART You can find the complete specifications in the instruction manual or on www.nivus.com 7 NivuFlow 750 patented How the NivuFlow 750 measures Flow cannot be measured directly. Multiple factors are required to detect the flow Q: average flow velocity and the flow cross section. This leads to the general formula: Q = v(average) • A The flow measurement principle as video under: www.nivus.com 8 The flow cross section A is investigated by continuously measuring the filling level considering the channel shape. The flow velocity is detected via the velocity of the particles. Most media contain a certain load of dirt particles or gas bubbles which move in the same velocity as the liquid itself. Level measurement (h) Flow velocity measurement (v) using cross correlation Accurate flow measurements require The measurement method used for flow velocity determination is based on the principle of ultrasonic reflection. One of the most modern and most efficient measurement methods for flow velocity detection is the cross correlation method by NIVUS. precise and reliable level detection under all hydraulic conditions. The development of a level measurement system with multiple redundancy is a result of our many years of experience. Combining hydrostatic measurement, water-ultrasound and airultrasound provides solutions for all measurement tasks. External 4- 20 mA level sensors such as "i-Series" sensors or NivuBar Plus can be connected additionally. Existing reflectors within the medium (particles, minerals or gas bubbles) are scanned using an ultrasonic impulse with a defined angle. The resulting echoes are saved subsequently as images or echo patterns. Considering the beam angle it is possible to directly compute the particle velocity and hence the medium flow velocity from the temporal shift of the reflectors. This allows to obtain highly accurate readings without the need to perform additional calibration measurements. 1. Scan Windows 4 to 16 Window 3 Window 2 Window 1 A few milliseconds later a second scan follows. The resulting echo patterns are saved as well. 2. Scan Your benefits + Highest measurement accuracy + Stable readings + No calibration required + Determination and indication of flow profiles By correlating/comparing the saved signals, the positions of unambiguously identifiable reflectors can be identified. Since the reflectors have moved with the medium, they can be identified at varying positions in the images. 1. Scan + 2. Scan Overlay of image patterns The NivuFlow 750 uses up to 9 x 16 gates for flow measurement. A flow profile can be directly indicated on the display. 9 NivuFlow 750 On site from anywhere + Integrated data logger for high data security + Saved data can be recalled at any time + Online operation and online setting of parameters (remote control) + Quick and comprehensive remote diagnostics of entire measurement places Latest Technologies Based on the latest hydraulic models, the NIVUS-COSP system from the individual measurement spots computes a dense measurement network covering the entire flow cross section. The NivuFlow 750 provides options for remote maintenance, remote diagnostics and the flexible integration into process conducting systems and telecontrol networks. + Scientifically tested, channelspecific mathematical real-time flow models. + Calculation of flow velocity distributions in proximity to walls and horizontal velocity profiles. + Velocity integration covering the entire cross section. + Ideal to investigate average flow velocities in flumes with hydraulic disturbances. EX Separation Module iXT / Multiplexer MPX The Ex separation module iXT is a Multiplexer used for sensor connection in Ex zone 1. The Multiplexer Type MPX allows the electronic combination of up to 3 flow velocity sensors and 3 level sensors on site. 75 110 Technical Information 70 Dimensions in mm Power supply Protection Ex approval iXT Inputs Outputs 12 V DC, max. power consumption 9 W (typ. 7 W), supplied by transmitter IP20 ATEX and IECEx, ATEX: TÜV14ATEX142076, IECEx: TUN14.0014 1 (optional 2) x analog 4-20 mA loop-powered sensor connection Ex ib Gb IIB, one of them HART compatible 2 (optional 4) x sensor connection Ex ib Gb IIB with RS485 interface RS 485 to transmitter You can find the complete specifications in the instruction manual or on www.nivus.com 10 NIVUS - Instrumentation for Water Industry The suitable solution for each application. Tried and tested measurement systems to perfectly fit your needs. Measurement systems which measure right what they should, reliably and accurately - even under difficult conditions. This is our claim! Wide Range of Measurement Systems We provide the suitable method for each application and each medium v Cross Correlation v Transit Time v v Radar Doppler h Hydraulics Variety of Sensors Suitable for each application - we offer the widest range of sensors in various designs. Measurement Systems and System Control We provide the entire portfolio from easy-to-operate transmitters with integrated numeric models through complete process control systems. Competent Advice Our experts are able to draw on many years of experience of measuring in the water and wastewater area. This allows to develop the best possible solutions for your applications. Your benefits + Accurate and reliable measurement results + Perfectly dimensioned measurement systems + Saves costs thanks to quick and easy installation and commissioning procedures + Low personnel expenses through integrated systems + One competent contact person for all components 11 NIVUS GmbH Im Taele 2 75031 Eppingen, Germany Phone: +49 (0)7262 9191-0 Fax: +49 (0)7262 9191-999 E-Mail: info@nivus.com Internet: www.nivus.com NIVUS AG Hauptstrasse 49 8750 Glarus, Switzerland Phone: +41 (0)55 6452066 Fax: +41 (0)55 6452014 E-Mail: swiss@nivus.com Internet: www.nivus.com NIVUS Austria Mühlbergstraße 33B 3382 Loosdorf, Austria Phone: +43 (0)2754 567 63 21 Fax: +43 (0)2754 567 63 20 E-mail: austria@nivus.com Internet: www.nivus.com NIVUS France 14, rue de la Paix 67770 Sessenheim, France Phone: +33 (0)3 88071696 Fax: +33 (0)3 88071697 E-Mail: france@nivus.com Internet: www.nivus.fr NIVUS Ltd. Wedgewood Rugby Road Weston under Wetherley Royal Leamington Spa CV33 9BW, Warwickshire, UK Phone: +44 (0)1926 632470 E-Mail: info@nivus.com Internet: www.nivus.com NIVUS Middle East (FZE) Building Q 1-1, ap. 055 P.O. Box: 9217 Sharjah Airport International Free Zone Phone: +971 6 55 78 224 Fax: +971 6 55 78 225 E-Mail: middle-east@nivus.com Internet: www.nivus.com NIVUS Korea Co. Ltd. #2502, M Dong, Technopark IT Center 32 Song-do-gwa-hak-ro, Yeon-su-gu, INCHEON, Korea 406-840 Phone: +82 32 209 8588 Fax: +82 32 209 8590 E-Mail: korea@nivus.com Internet: www.nivus.com Specifications subject to change. 30.07.2015 / FA2000 NIVUS Sp. z o.o. ul. Hutnicza 3 / B-18 81-212 Gdynia, Poland Phone: +48 (0)58 7602015 Fax: +48 (0)58 7602014 E-Mail: poland@nivus.com Internet: www.nivus.pl

相关文章